Residual Current Protective Devices / Arc Fault Detection Devices

Similar documents
Miniature Circuit Breakers for Railway Applications

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

5SL Miniature Circuit Breakers

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Combined RCD/MCB Devices FRBmM, 1+N-pole

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

1492-SP Supplementary Protectors

Residual Current Devices drcm Digital

Overvoltage Protection Devices

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Miniature circuit breakers for all applications

Contact protection relay

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Add-on Residual Current Protection PBSM MW

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

STEP-PS/1AC/24DC/1.75

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Overvoltage Protection Devices

Product and functional description

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

SIMOCODE 3UF Motor Management and Control Devices

Section 4 Ground-Fault Protection Devices

Power supply CP-E 48/1.25 Primary switch mode power supply

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Power supply CP-E 24/10.0 Primary switch mode power supply

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

UL 489 DIN Rail Miniature Circuit Breakers

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Monitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview

Protection Equipment

Power supply CP-E 24/0.75 Primary switch mode power supply

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Overvoltage Protection Devices

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

UL 489 DIN Rail Miniature Circuit Breakers

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Allen-Bradley 1492-RCDA4A40

Product and functional description

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

QUINT-PS/ 1AC/24DC/ 5

Overvoltage Protection Devices

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Jtec 10kA Miniature Circuit Breaker

Controls Solid-State Switching Devices

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

PHOENIX CONTACT - 07/2006

Power supply CP-D 12/2.1 Primary switch mode power supply

Bulletin 1489 Circuit Breakers. Selection Guide

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

Overvoltage Protection Devices

DINALOG A 144 x 36 A1400 Light-Strip Indicator

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI-PS AC/10-15DC/8

Voltage Current Front-mounting bracket

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Power supply CP-C 24/5.0

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

CC COMPACT DIP SWITCH

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

QUINT-PS/ 1AC/24DC/20/CO

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

PHOENIX CONTACT - 01/2007

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

SITOP in the SIMATIC Design

Product and functional description

Table of Contents Protective Devices / Components

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

Miniature Circuit-Breaker IEC Series 8562

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Signal Doublers. VariTrans A 20300

Lightning and Surge Arresters

DSE201, DSE201 M Compact design with enhanced protection

Electronic timer CT-AHD.22

QUINT-BUFFER/24DC/24DC/40

Electronic timer CT-ERD.12

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PRODUCT SPECIFICATION. PC Board Relays. Series.

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Ultra Slim Relays 24

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

Bulletin 817 Thermistor Protection Relay

Transcription:

Residual Current Protective Devices / Arc Fault Detection Devices SENTRON Configuration Manual Edition 10/015 siemens.com/lowvoltage

Introduction 5SV / 5SM3 RCCBs 13 SIQUENCE 5SM3/5SU1 universal current sensitive RCCBs, type B and type B+ 19 Additional components 3 5SM RC units 5SU1 RCBOs 3 5SM AFD units 37 5SM AFD units for PV applications 39 5ST busbars for modular installation devices 5SM1 and 5SZ9 RCCB socket outlets 3 Configuration For further technical product information: Siemens Industry Online Support: www.siemens.com/lowvoltage/productsupport. Entry type: Application example Certificate Characteristic Download FAQ Manual Product note Software archive Technical data Siemens 10/015

Introduction Overview Devices Page Application Standards Used in 5SV RCCBs Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for use in harsh environments. Super resistant and selective versions IEC/EN 1008 ÖVE EN 1008 ÖVE/ÖNORM E 801 IEC/EN 3 Non-residential buildings Residential buildings Industry 5SM3 RCCBs Personnel, material and fire protection, as well as protection against direct contact IEC/EN 1008 ÖVE EN 1008 ÖVE/ÖNORM E 801 IEC/EN 3 SIQUENCE 5SM3/5SU1 Universal current sensitive RCCBs, type B and type B+ 13 SIQUENCE, the technology of universal current-sensitive residual current protective devices VDE 0-100 VDE 0-00 VDE V 0-110 -- Additional components 19 Remote controlled mechanisms, auxiliary switches for all residual current operated circuit breakers. Leakage current measurement device for fault locating and the optimum selection of RCCBs IEC/EN 019 -- RC units, 5SM 3 The freely selectable combination of RC IEC/EN 1009 units with miniature circuit breakers permits -- the flexible configuration of RCBO combinations 5SU1 RCBOs The ideal protection combination for all electrical circuits due to the compact device versions of RCCBs and miniature circuit breakers in a single device IEC/EN 1009 5SM AFD units 3 Enhanced fire protection through the detection and isolation of arcing faults IEC/EN 0 -- 5ST busbars for modular installation devices 5SM1 and 5SZ9 RCCB Socket outlets 39 Busbars in 10 mm and 1 mm save space in the distribution board and time during mounting. -- For retrofitting in existing installations VDE 0 10 ma 30 ma Configuration 3 This section tells you all you need to know about RCCBs in combination with miniature circuit breakers, with information about tripping characteristics, selectivity and breaking capacity -- 3 Siemens 10/015

SIGRES SIGRES RCCBs were developed for use in harsh ambient conditions, such as swimming baths as protection against chlorine and ozone, in the agricultural sector (ammonia), on building sites and in the chemical industry (nitrogen oxide, sulfur dioxide, solvents), in the food processing industry (hydrogen sulfide) and in unheated rooms (dampness). The patented active condensation protection requires a continuous power supply and bottom infeed if the RCCB is switched off. When used in ambient conditions as defined in product standard EN 1008-1, the operation interval for pressing the test button can be extended to once a year. Super resistant æ Super resistant (short-time delayed) RCCBs meet the maximum permissible break times for instantaneous devices. However, by implementing a short-time delay they prevent unnecessary tripping operations, and thus plant faults, when pulse-shaped leakage currents occur as is the case when capacitors are switched on. Selective î Can be used as upstream group switch for selective tripping contrary to downstream, instantaneous or short-time delayed RCCBs. Note: For more information on the subject of residual current protective devices, see the technology primer "Residual Current Protective Devices", Article No.: E10003-E38-B-G0090-700. AC RCCB K A S F Design RCBO Type B B+ RC unit SIGRES 500 V 50-00 Hz 1+N 3 3+N Additional protection I n 30 ma Version Number of poles Rated residual current I n protection objective Residual current protection I n > 30mA Trip conditions limited I n Rated current I n Fire protection I n 300 ma Introduction Selection criterion Equipment, circuit, load current, residual current System, equipment, ambient conditions Equipment Installation regulation VDE 0100-10 -530-7xx -8 VDS 3501 Equipment Only with RCBOs with MCB characteristic B C D Trip conditions acc. to VDE 0100-10 Equipment Selection aid for finding the appropriate residual current protective device I01_15509b Siemens 10/015 3

5SV / 5SM3 RCCBs Overview RCCBs are used in all systems up to 0/15 V AC. Devices of type AC trip in the event of sinusoidal AC residual currents, type A also trips in the event of pulsating DC residual currents. In addition, RCCBs type F also detect residual currents with mixed frequencies up to 1 khz. RCCBs with a rated residual current of maximum 30 ma are used for personnel, material and fire protection, as well as for protection against direct contact. RCCBs with a rated residual current of 10 ma are primarily used in areas that represent an increased risk for personnel. Since the introduction of DIN VDE 0100-10, all socket outlet current circuits up to 0 A must also be fitted with residual current protective devices with a rated residual current of max. 30 ma. This also applies to outdoor electrical circuits up to 3 A for the connection of portable equipment. Devices with a rated residual current of maximum 300 ma are used as preventive fire protection in case of insulation faults. RCCBs with a rated residual current of 100 ma are primarily used outside Europe. Benefits Instantaneous RCCBs with the N connection on the left-hand side enable simple bus mounting with standard pin busbars with miniature circuit breakers installed on the right-hand side Instantaneous RCCBs with the N connection on the right-hand side can be bus-mounted with miniature circuit breakers using a special pin busbar Instantaneous type A devices have a surge current withstand capability with current waveform 8/0 μs of more than 1 ka, super resistant of more than 3 ka and selective of more than 5 ka. This ensures safe operation SIGRES has an extremely long service life due to a patented active condensation protection and identical dimensions enable the quick and easy replacement of existing instantaneous RCCBs Super resistant devices increase system availability, as unnecessary tripping is prevented in power supply systems with short-time glitches Selective RCCBs increase system availability as a staggered tripping time enables the selective tripping of RCCBs connected in series in the event of a fault Auxiliary switches or remote controlled mechanisms are also available as additional components The operating handle and the test button can be locked by means of a handle locking device All additional components that match the 5SY and 5SL miniature circuit breakers can also be fitted on the 5SV Siemens 10/015

5SV / 5SM3 RCCBs Technical specifications 5SV3 Instantaneous SIGRES Super resistant Selective Standards IEC/EN 1008-1 (VDE 0-10); IEC/EN 1008--1 (VDE 0-11); IEC/EN 153 (VDE 0-30); IEC/EN 3 (VDE 0-0) Surge current withstand capability Type A with current waveform 8/0 µs Type F with current waveform 8/0 µs Acc. to EN 000- (VDE 03-) Acc. to EN 000- (VDE 03-) ka > 1 > 3 > 5 ka -- -- > 3 -- Minimum operational voltage for test function operation 30 ma devices V AC 195 Non-30 ma devices V AC 100 V devices V AC 0 Test cycles 1/ year 1 year 1/ year Insulation coordination Overvoltage category III Pollution degree Terminal conductor cross-sections 1-wire -Solid( 10 mm ) / stranded ( 1 mm ) mm 0.75... 35 - Finely stranded with non-insulated end sleeve mm 0.75... 5 - Finely stranded with insulated end sleeve mm 0.75... 5 - Finely stranded without end sleeve mm 1... 35 -wire, same cross-section, same conductor type -Solid( 10 mm ) / stranded ( 1 mm ) mm 0.75... 10 - Finely stranded with non-insulated end sleeve mm 0.75... - Finely stranded with insulated end sleeve mm 0.75... - Finely stranded without end sleeve mm 1... 1-wire + busbar (pin thickness 1.5 mm) -Solid( 10 mm ) / stranded ( 1 mm ) mm 10... 5 - Finely stranded with non-insulated end sleeve mm... 5 - Finely stranded with insulated end sleeve mm... 1 Terminal tightening torque Up to I n = 80 A Nm.5 At I n = 100 A, 15 A Nm 3.0... 3.5 Mains connection Top or bottom Bottom Top or bottom Rated frequency Hz 50/0 1) Mounting position (on a standard mounting rail) Any Degree of protection Acc. to EN 059 IP0, if the distribution board is installed, with connected conductors (VDE 070-1) Touch protection Acc. to EN 507 Finger and back-of-hand safe (VDE 00-51) Service life Average number of switching cycles > 10000 Test cycle acc. to IEC/EN 1008 Storage temperature C -0... +75 Ambient temperature C -5... +5, marked with -5 Resistance to climate Acc. to IEC 008--30 8 cycles (55 C; 95 % rel. air humidity) CFC and silicone-free Yes 1) 5SV residual current operated circuit breakers have been developed for 50 Hz systems and can detect and shut down ground fault currents of this frequency, but in the case of residual currents that deviate markedly from this frequency, or that have a higher proportion of harmonics, the trip values increase slightly. Siemens 10/015 5

5SV / 5SM3 RCCBs Power losses per conducting path under rated current load 1) Note: For SIGRES versions, the power ratings below must be added for each device for heating of the holding magnet release: MW: 0.33 W MW: 0. W MLFB Power losses per conducting path P v [W] MLFB 5SV3111-0.7 5SV31-0. 5SV3111-KL 0.7 5SV31-KK01 0.5 5SV3311-0. 5SV31-KL 0. 5SV3311-KK1 0.5 1) 5SV31-8 0.5 5SV3311-KK13 0. 5SV31-3 1.0 5SV3311-KL 0. 5SV31-1. 5SV331-3 0.8 5SV31-KK01 1.0 5SV331-1.0 5SV31-KL 1. 5SV331-KK01 0.8 5SV31-7 1.0 5SV331-KK1 0.8 1) 5SV31-8 1.0 5SV331-KK13 1.0 5SV31-8KL 1.0 5SV331-KL 1.0 5SV31-3.7 5SV331-3 1.5 5SV31-.7 5SV331-. 5SV31-KK01.7 5SV331-KK01 1.5 5SV31-KL.7 5SV331-KK1 1.5 1) 5SV31-8.7 5SV331-KK13. 5SV31-8KL.7 5SV331-KL. 5SV317-3 3.9 5SV331-LA 1.5 5SV317-3.9 5SV331-LA01 1.5 5SV317-KK01 3.9 5SV331-3 5.3 5SV317-KL 3.9 5SV331-5.3 5SV317-7 3.9 5SV331-KK01 5.3 5SV317-8 3.9 5SV331-KK1 5.3 1) 5SV3-3 0.8 5SV331-KK13 5.3 5SV3-0.7 5SV331-KL 5.3 5SV3-KK01 0.8 5SV3317-3 5. 5SV3-KK1 0.8 1) 5SV3317-5. 5SV3-KL 0.7 5SV3317-KK01 5. 5SV3-8 0.8 5SV3317-KL 5. 5SV3-3 1.8 5SV33-3 0.8 5SV3-.0 5SV33-1.3 5SV3-KK01 1.8 5SV33-KK01 0.8 5SV3-KK1 1.8 1) 5SV33-KK03 1.3 5SV3-KL.0 5SV33-KK1 0.8 1) 5SV3-7 1.8 5SV33-KL 1.3 5SV3-8 1.8 5SV33-3 1.8 5SV3-8LA 1.8 5SV33-3.9 5SV3-3 3.9 5SV33-KK01 1.8 5SV3-3.9 5SV33-KK03 3.9 5SV3-KK01 3.9 5SV33-KK1 1.8 1) 5SV3-KK1 3.9 1) 5SV33-KL 3.9 5SV3-KL 3.9 5SV33-LA 1.8 5SV3-8 3.9 5SV33-LA01 1.8 5SV3-8KK1 3.9 1) 5SV33-3 3.9 5SV3-8KL 3.9 5SV33-3.9 5SV3-8LA 3.9 5SV33-KK01 3.9 5SV37-3.1 5SV33-KK1 3.9 1) 5SV37-.1 5SV33-KL 3.9 5SV37-KK01.1 5SV33-LA 3.9 5SV37-KK1.1 1) 5SV33-LA01 3.9 5SV37-KL.1 5SV337-3.1 5SV37-7.1 5SV337-.1 5SV37-8.1 5SV337-KK01.1 5SV35-0.8 5SV337-KK1.1 1) 5SV35-1.8 5SV337-KL.1 5SV35-3.9 5SV335-0.8 5SV357-.1 5SV335-1.8 5SV37-0.8 5SV335-3.9 5SV37-1.8 5SV3357-.1 5SV37-3.9 5SV31-0. 5SV37-KL 3.9 5SV31-KL 0. 5SV377-.1 5SV31-1. 5SV38-8 3.9 5SV31-KL 1. 5SV331-BA 1.0 Power losses per conducting path P v [W] Siemens 10/015

5SV / 5SM3 RCCBs Power losses per conducting path under rated current load 1) Note: For SIGRES versions, the power ratings below must be added for each device for heating of the holding magnet release: MW: 0.33 W MW: 0. W MLFB Power losses per conducting path P v [W] MLFB 5SV31-.7 5SV331-BA. 5SV31-KL.7 5SV331-BA 5.3 5SV31-8 5.3 5SV33-BA 1.3 5SV317-3.9 5SV33-BA 3.9 5SV317-KL 3.9 5SV33-BA 3.9 5SV3-0.7 5SV31-BA 0. 5SV3-.0 5SV31-BA 1. 5SV3-LA 1.8 5SV31-BA.7 5SV3-LA01 1.8 5SV3-BA 0.7 5SV3-8 1.8 5SV3-BA.0 5SV3-8LA 1.8 5SV3-BA 3.9 5SV3-3.9 5SV5311-KL 0. 5SV3-LA 3.9 5SV531-KL 1.0 5SV3-LA01 3.9 5SV531-KL. 5SV3-8 3.9 5SV53-KL 1.3 5SV3-8LA 3.9 5SV53-KL 3.9 5SV37-.1 5SV53-KL 3.9 5SV31-3 0.5 5SV5-KL 3.9 Power losses per conducting path P v [W] Siemens 10/015 7

5SV / 5SM3 RCCBs 5SM3 Instantaneous Selective Standards IEC/EN 1008-1 (VDE 0-10); IEC/EN 1008--1 (VDE 0-11); IEC/EN 153 (VDE 0-30); IEC/EN 3 (VDE 0-0) Surge current withstand capability Type A with current waveform 8/0 µs Acc. to EN 000- (VDE 03-) ka > 1 > 5 Minimum operational voltage for test function operation V AC 195 Test cycles 1/ year Insulation coordination Overvoltage category III Pollution degree Terminal conductor cross-sections MW I n = 100 A, 15 A mm 1.5... 50 MW I n = 100 A, 15 A mm.5... 50 Terminal tightening torque I n = 100 A, 15 A Nm 3.0... 3.5 Mains connection Top or bottom Mounting position (on a standard mounting rail) Any Degree of protection Acc. to EN 059 IP0, if the distribution board is installed, with connected conductors (VDE 070-1) Touch protection Acc. to EN 507 Finger and back-of-hand safe (VDE 00-51) Service life Average number of switching cycles > 10000 Storage temperature C -0... +75 Ambient temperature C -5... +5, marked with -5 Resistance to climate Acc. to IEC 008--30 8 cycles (55 C; 95 % rel. air humidity) CFC and silicone-free Yes Power losses per conducting path under rated current load Note: 0. W per unit must be added for SIGRES versions. Number of poles Rated current Rated residual current I Δn [ma] 1 10.5 30 0.8 5 30 100/300 1 0 30.3 100/300.5 3 30. 100/300 3.5 80 30. 100/300 3.5 5 30 1. 300/500 0.7 0 30 3 100/300/500 1. 3 30.9 100/300/500/1000 3 80 30 5.8 300.8 15 30 8.9 100/300/500 8.9 Power losses per conducting path P v [W] 8 Siemens 10/015

5SV / 5SM3 RCCBs Suitable RCCB type Circuits Load current Residual current B F A AC i F1 i F1 B+ i F1 i F1 i F1 i F1 i L L1 N PE i F1 i F M i L t i F1 i F t i F1 i F1 i F1 11 i L L1 L N PE i F1 i F M i L t i F1 i F t i F1 1 13 i L L1 L L3 N PE i F1 i F M i L t i F1 i F t i01_105 Table: Possible residual current forms and suitable residual current devices Siemens 10/015 9

5SV / 5SM3 RCCBs Configuration When using residual current protective devices type F, please note the following: They are not suitable for equipment that can generate smooth DC residual currents (see Table, page 9, circuits 8 to 13). They are not suitable for installation in networks with frequencies that deviate from the rated frequency (50 Hz) (not at the outgoing terminal of a frequency converter). When configuring and setting up electrical systems with type F, the same applies as for residual current protective devices type A, i.e. electrical loads that can generate smooth DC residual currents in the event of a fault are assigned their own circuit with a universal current-sensitive residual current protective device (type B or type B+). Wh Wh Type AC/A/F Type AC/A/F I n 300 ma S I n 300 ma S Type AC/A/F I n 100 ma Type B/B+ khz I 30 ma n Type AC/A/F I n 100 ma Type B/B+ khz I n 30 ma i01_1813 i01_181 It is not permitted to branch off electrical circuits with these types of electrical loads downstream of pulse-current-sensitive residual current protective devices (type A or type F). 10 Siemens 10/015

Dimensional drawings 5SV3 dimensional drawings 5SV / 5SM3 RCCBs 35,8 71 3,9 0 71,8 71 3,9 0 5,15 5,15 89,8, I01_1855 89,8, I01_185 RCCBs, type A and type AC 1P+N, MW RCCBs, type A and type AC 3P+N, MW 5SM3 dimensional drawings RCCBs up to 80 A 1 N 1 N 1 3 5 N 5 90 N 1P+N MW N 3 5 7 1P+N.5 MW RCCBs 100 and 15 A N 3P+N MW 7 I01_0780c 1 N 1/L1 3/L 5/L3 7/N 5 88 5 87 N 3 7 I01_185a 5 70 /L1 /L /L3 8/N 7 7 I01_07830a 5 8 1P+N, MW 3P+N, MW Siemens 10/015 11

5SV / 5SM3 RCCBs Circuit diagrams Graphic symbols 1 N 1 3 5 N N I01_133 N I01_1337 1P+N 3P+N N connection, right N 1 N 1 3 5 N N connection, left I0_5058 N connection, left N Note: The infeed for SIGRES devices must be from below at terminals,, and N. I01_1338 1 Siemens 10/015

Overview Frequency converters, medical devices and UPS systems are seeing increasing use in industry. Smooth DC residual currents or currents with low residual ripple may occur in the event of faults on these devices. Type A residual current protective devices are unable to detect these smooth DC residual currents. Furthermore, such smooth DC residual currents make type A devices increasingly insensitive to AC residual currents and pulsating DC residual currents. If a fault occurs, there is therefore no tripping and the desired protective function is no longer assured. UC-sensitive residual current protective devices of types B and B+ have an additional transformer which is supplied with a control signal. This enables an evaluation of the change of the transformer's operating range caused by smooth DC residual currents, thus ensuring the desired protective function. The residual current protective devices of type B are suitable for use in three-phase current systems before input circuits with rectifiers. They are not intended for use in DC systems and in networks with operating frequencies other than 50 Hz or 0 Hz. The devices in this series are designed as residual current operated circuit breakers (RCCBs) up to 80 A and as residual current circuit breakers with integral overcurrent protection (RCBOs) for 100 A or 15 A in Characteristics C or D. All universal current-sensitive RCCBs, type B or B+ are now also available in a SIGRES version, meaning they are also ideal for use in harsh ambient conditions. When used in ambient conditions as defined in product standard EN 1008-1, the operation interval for pressing the test button can be extended to once a year. SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ Benefits Universal current-sensitive residual current protective devices detect not only AC residual currents and pulsating DC residual currents, but also smooth DC residual currents, thus ensuring the desired protective function with all types of residual current With type B, the tripping characteristic is adapted to suit the increase of leakage currents at higher frequencies in systems with capacitive impedances, thus ensuring greater operating safety Type B+ versions offer enhanced preventative fire protection and correspond to the prestandards DIN V VDE V 0-110 and/or DIN V VDE V 0-10 and VdS Directive 3501 The RCBO is a compact device for up to 15 A. It provides not only personnel, material and fire protection but also overload and short-circuit protection for cables. This reduces wiring and mounting outlay The RCBOs offer external remote tripping over terminals Y1/Y This supports implementation of central OFF circuits. Siemens 10/015 13

SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ Technical specifications Standards IEC/EN 3 (VDE 0-0); IEC/EN 153 (VDE 0-30); additionally applicable for type B+; DIN VDE 0-00 SIQUENCE, 5SM3 RCCBs, type B and type B+ SIQUENCE, 5SU1 RCBOs type B and type B+ IEC/EN 3 (VDE 0-0); IEC/EN 153 (VDE 0-30); additionally applicable for type B+; DIN VDE 0-01 Versions 1P+N 3P+N P Tripping characteristic -- -- C, D Surge current withstand capability With current waveform 8/0 µs Acc. to EN 000- (VDE 03-) Super resistant ka > 3 > 3 > 3 Selective ka -- > 5 > 5 Minimum operational voltage for test V AC 195 195 195 function operation Rated voltages U n V AC 30 00 00, 80 Rated frequency f n Hz 50... 0 Rated currents I n A 1, 5, 0, 3 5, 0, 3, 80 100, 15 Rated residual currents I Δn ma 30, 300 30, 300, 500 30, 300 Rated breaking capacity I m A 800 -- I cn ka -- 10 Insulation coordination Overvoltage category III Conductor cross-sections Solid and stranded mm 1.5... 5... 50 Finely stranded, with end sleeve mm 1.5... 1... 35 Terminal tightening torque Nm.5... 3.0 3.0... 3.5 For all devices Mains connection Either top or bottom (bottom for the effectiveness of the SIGRES function even when switched off) Mounting position (on a standard Any mounting rail) Degree of protection according to EN 059 IP0, if the distribution board is installed, with connected conductors (VDE 070-1) Touch protection Finger and back-of-hand safe Acc. to EN 507 (VDE 00-51) Service life > 10000 switching cycles Average number of switching cycles Storage temperature C -0... +75 Ambient temperature C -5... +5, marked with -5 Resistance to climate acc. to IEC 008--30 8 cycles (55 C; 95 % rel. air humidity) CFC and silicone-free Yes Power losses per conducting path under rated current load Note: 0. W per unit must be added for SIGRES versions. Number of poles Rated current Rated residual current I Δn [ma] / 1 30/300 0.17 5 30/300 0. 0 30/300 1.09 3 30/300/500.7 80 30/300/500.35 Power losses per conducting path P v [W] 1 Siemens 10/015

SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ Characteristic curves Tripping current (ma) 10000 1000 Tripping values for rated residual current 30 ma Tripping values for rated residual current 300 ma Tripping values for rated residual current 300 ma S Tripping values for rated residual current 500 ma / 500 ma S Upper limit according to VDE 0-100 for 30 ma Upper limit according to VDE 0-100 for 300 ma Upper limit according to VDE 0-100 for 500 ma 100 10 1 10 100 1000 10000 I0_08a Frequency (Hz) Tripping current as a function of frequency for type B 10000 Tripping current (ma) 1000 Tripping values for rated residual current 30 ma Tripping values for rated residual current 300 ma Upper limit according to DIN V VDE V 0-110 and DIN V VDE V 0-10 for 30 ma Upper limit according to DIN V VDE V 0-110 and DIN V VDE V 0-10 for 300 ma 100 10 1 10 100 1000 Frequency (Hz) 10000 I01_181 Tripping current as a function of frequency for type B+ Siemens 10/015 15

SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ Dimensional drawings 1 N I01_1397 1 3 5 N 5 90 5 90 T N 7 7 SIQUENCE RCCBs, type B and type B+ 1P+N, MW 7 T N SIQUENCE RCCBs, type B and type B+ 3P+N, MW 7 I01_19a 198 7 70 max 7 5 90 I01_13 SIQUENCE RCBOs, type B and type B+ P, 11 MW Circuit diagrams Graphic symbols 1 N 1 3 5 N Y1 Y 1 3 5 7 T I01_13973 N N 8 SIQUENCE RCCBs, type B and type B+ SIQUENCE RCCBs, type B and type B+ SIQUENCE RCBOs, type B and type B+ 1P+N, MW 3P+N, MW P, 11 MW I01_1375a I01_137 1 Siemens 10/015

SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ More information Device configuration Universal current-sensitive protective devices are based on a pulse-current-sensitive circuit-protection device with tripping independent of line voltage, supplemented with an auxiliary unit for the detection of smooth DC residual currents. The following diagrams show the basic design. The summation current transformer W1 monitors the electrical system for AC and pulse current-type residual currents. The summation current transformer W detects the smooth DC residual currents and, in the event of a fault, relays the tripping command through electronic unit E to release A, which uses the mechanics to disconnect the circuit. M A E n n 1 3 5 N N Design of RCCBs type B and type B+ W1 W T I01_1308a Method of operation The universal current-sensitive residual current protective devices work independently of the supply voltage compliant with applicable requirements in Germany for Type A according to DIN VDE 0-100. A voltage supply is required solely for the detection of smooth DC residual currents by a second transformer. This is done from all system cables and is dimensioned so that the electronics still reliably trip even with a voltage reduction to 50 V. This ensures tripping for smooth DC residual currents, as long as such residual current waveforms can occur, even in the event of faults in the electrical power supply, e.g. an N-conductor break. This means that the pulse-current-sensitive breaker component, which trips regardless of line voltage, will still reliably trigger the tripping operation even in the highly unlikely event that two phase conductors and the neutral conductor fail if the remaining intact phase conductor presents a fire hazard due to a ground fault. The residual current protective devices of type B are suitable for use in three-phase current systems before input circuits with rectifiers. They are not intended for use in DC systems and in networks with operating frequencies other than 50 Hz or 0 Hz. RCBOs are a combination of an RCCB and a miniature circuit breaker for up to 15 A in a single compact device. This means they provide not only personnel, property and fire protection, but also overload and short-circuit protection for cables. The mechanics of the residual current protective device act on the tripping unit of the miniature circuit breaker, which disconnects the circuit. 1 3 5 7 M LS A n W1 E n W T 8 I01_1309b Design of RCBOs type B and type B+ M LS A E n W1 W T Mechanics of the RCCB Miniature circuit breaker component Release Electronics for tripping in the event of smooth DC residual currents Secondary winding Summation current transformer for detection of sinusoidal residual currents Summation current transformer for detection of smooth DC residual currents Test equipment Siemens 10/015 17

SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ Protective effect at high frequencies In addition to the described residual current waveforms (AC residual currents, pulsating and smooth DC residual currents), AC residual currents with a wide range of frequencies may also occur on electronic equipment such as rectifiers in frequency converters or computer tomographs as well as at the outgoing terminal of a frequency converter. Requirements for frequencies up to khz are defined in the device regulations DIN VDE 0-100. To date, only limited statements can be made with regard to the risk of ventricular fibrillations (up to 1 khz) for frequencies higher than 100 Hz. No reliable statements can be made on any further effects of thermal or electrolytic influence on the human organism. For this reason, protection against direct contact is only possible for frequencies up to 100 Hz. For higher frequencies, protection against indirect contact must be implemented under consideration of the frequency response of the residual current protective device, the maximum permissible touch voltage up to 50 V and permissible grounding resistance derived from this information. When configuring and installing electrical installations, electrical loads that can generate smooth DC residual currents in the event of a fault must be assigned a separate electrical circuit with a universal current-sensitive residual current protective device (type B): 30/00 V AC, 3-phase Wh Type AC/A n 300 ma S Rated residual current Max. permissible grounding resistance for touch voltage 50 V 5 V Type AC/A n 100 ma Type B/B+ 30 ma n 30 ma 10 Ω 80 Ω 300 ma 1 Ω 1) 8 Ω 1) 500 ma 10 Ω 5 Ω 1) For type B+ the value is allowed to be up to 10 Ω at 50 V and 0 Ω at 5 V. I01_1310c Recommended maximum grounding resistance for SIQUENCE universal current-sensitive residual current protective devices type B and type B+. Versions Super resistant æ: Short-time delayed tripping in the case of transient leakage currents. High surge current withstand capability > 3 ka. Selective î: Can be used as upstream group switch for selective tripping contrary to a downstream, instantaneous or super resistant RCCB. Configuration DIN VDE 0100-530 "Selection of protective devices" also describes the configuration of systems with residual current protective devices. EN 50178 (DIN VDE 010) "Electronic equipment for use in power installations" describes, among other things, how to select the type of residual current protective device suitable. It is not permitted to branch electrical circuits with these types of electrical loads after pulse-current-sensitive residual current protective devices (type A): 30/00 V AC, 3-phase Wh Type AC/A 300 ma n S Type AC/A n 100 ma Type B/B+ 30 ma n I01_1311c 18 Siemens 10/015

Overview Auxiliary switches (AS) The auxiliary switch (AS) always signals the contact position, regardless of whether the RCCB was tripped manually or as the result of a fault. An additional version is also available for the switching of small currents and voltages for the control of programmable control systems (PLCs) acc. to EN 1131-. The auxiliary switch with test button enables the testing of control circuits without the need to switch the RCCB. Fault signal contacts (FC) The fault signal contact (FC) signals automatic breaking in the event of a fault. If the fault signal contact is activated, the contact Benefits position does not change if the RCCB is tripped manually. Fault signal contacts with TEST and RESET buttons enable testing of control circuits without the need to trip the RCCB. The red RESET button integrated in the handle also indicates automatic tripping of the RCCB. The signal can be acknowledged manually using the RESET button. Shunt trips (ST) Shunt trips are used for the remote tripping of RCCBs. Undervoltage releases (UR) Undervoltage releases are integrated (e.g. in EMERGENCY STOP loops), thus ensuring tripping in the event of an emergency, which, in turn, ensures disconnection of the control circuit according to EN 00. In the event that the voltage is interrupted or too low, it also trips, i.e. prevents activation of the RCCB. Additional components Remote controlled mechanisms are used for the remote ON/OFF switching of RCCBs. They also enable local manual switching. A blocking function permits maintenance work. A tripped RCCB must be acknowledged prior to switching back on. The leakage current measurement device detects the leakage currents like the circuit breaker thus providing a direct statement as to the current loading of the RCCB. It is used to measure leakage currents up to 300 ma. This requires a voltmeter with an internal resistance over 1 MΩ/V and a measuring range for AC voltages of U rms = 1 mv to V. For the fault-free operation of an RCCB, the measured leakage current should be no greater than 1/3 of the rated residual current. Can be universally retrofitted with all additional components Captive metal brackets on the additional components ensure the quick and easy mounting of devices without the need for tools. Fault signal contacts with TEST and RESET button enable simple testing of auxiliary circuits and, in the event of a fault, acknowledgement of the fault over the RESET button, without the need to switch the RCCBs. The auxiliary switches with TEST button enable simple manual testing of control circuits during operation of the entire installation without the need to switch the RCCBs. Bus systems, such as instabus KNX, AS-Interface bus or PROFIBUS, can be integrated in the communication over binary inputs The leakage current measurement device enables the systematic selection of the rated residual current, thus preventing inadvertent tripping of an RCCB. Technical specifications Auxiliary switches (AS) Auxiliary switches (AS) 5SW330. 5SW3330 Standards EN 019 Terminals Conductor cross-section mm 0.75....5 Tightening torque Nm 0.5 Short-circuit protection B or C or gl/gg A fuse Min. contact load 50 ma/ V Max. contact load 30 V AC, AC-1 A 5 30 V AC, AC-1 A 3. -- 0 V DC, DC-1 A 1 0.5 Siemens 10/015 19

Additional components Auxiliary switches (AS) Fault signal contacts (FC) 5ST3010, 5ST3010-5ST3011, 5ST3011-5ST301, 5ST301-5ST3013, 5ST3013-5ST301, 5ST301-5ST3015, 5ST3015-5ST300, 5ST300-5ST301, 5ST301-5ST30, 5ST30- Standards EN 019; IEC/EN 097-5-1; UL 1077; CSA C. No. 35 Approvals www.siemens.com/lowvoltage/certificates Short-circuit protection Miniature circuit breaker or gg A fuse Contact load Min. 50 ma, V 1 ma/5 V DC 50 ma, V Max. -- 50 ma/30 V DC -- 00 V AC, AC-1, NO A -- 30 V AC, AC-1, NO A -- 00 V AC, AC-13, NC A -- 30 V AC, AC-13, NC A -- 0 V DC, DC-13, NO+NC A 1 -- 1 110 V DC, DC-13, NO+NC A 1 -- 1 0 V DC, DC-13, NO+NC A 3 -- 3 V DC, DC-13, NO+NC A -- Service life, on average, with rated load 0 000 actuations 0000 actuations 0000 actuations Conductor cross-sections mm 0.5....5 0.5....5 0.5....5 AWG... 1... 1... 1 Terminals Terminal tightening torque Nm 0.5 0.5 0.5 lbs/in..5.5.5 Mounting position Any Any Any Ambient temperature C -5... +55-5... +55-5... +55 Storage temperature C -0... +75-0... +75-0... +75 Resistance to climate Acc. to IEC 008--30 Cycles 8 Shock Acc. to IEC 008--7 m/s 50 at 11ms half-sine Resistance to vibrations Acc. to IEC 008-- m/s 50 at 10... 150 Hz Undervoltage releases (UR) Shunt trips (ST) 5ST30. 5ST3030 5ST3031 Standards EN 097-1 Rated voltages U n V AC 30 110... 15... 8 V DC, 110 110... 8 Operating range U n 0.85... 1.1 x U n 0.7... 1.1 x U n Rated frequency f n Hz -- 50... 0 Response limits Tripping < 0.35... 0.7 U n -- Short-circuit protection Miniature circuit breakers B/C A or fuse gg A Minimum contact load 50 ma, V 50 ma, V Tripping operations max. 000 max. 000 Service life, on average, with rated load 0000 actuations 0000 actuations Conductor cross-sections mm 0.5....5 0.5....5 AWG... 1... 1 Terminals Terminal tightening torque Nm 0.8 0.8 lbs/in..8.8 Mounting position Any Any Ambient temperature C -5... +55-5... +55 Storage temperature C -0... +75-0... +75 Resistance to climate Acc. to IEC 008--30 Cycles 8 Shock Acc. to IEC 008--7 m/s 50 at 11ms half-sine Resistance to vibrations Acc. to IEC 008-- m/s 50 at 10... 150 Hz Switching frequency -- Switching duration s -- Minimum command duration s -- Rated power dissipation VA -- Behavior in the event of control voltage failure -- 0 Siemens 10/015

Additional components Dimensional drawings 5 90 9 5 90 I01_1a 18 I01_1357 70 3 73 7 5ST3010 5ST3011 5ST301 5ST3013 5ST301 5ST3015 5ST300 5ST301 5ST30 5ST3030 5ST3031 5ST300 5ST301 5ST30 5ST303 5ST30 5ST305 5ST3050 I0_003 I0_0033 I0_0033 90 5 90 90 5 90 9 70 9 70 5ST3010-5ST3011-5ST301-5ST3013-5ST301-5ST3015-5ST300-5ST301-5ST30- Auxiliary switches (AS) for RCCBs for 5SM3 up to 80 A Auxiliary switches (AS) for RCCBs for 5SM3, 100 A, 15 A, 3P+N 5 90 5 87 I01_0781d I01_078b I0_003 9 7 9 3 0 Remote-controlled mechanism Leakage current measurement device I01_1a 1 3 5 N 5 90 I01_0783c 5 90 N 3 73 7 7 7 55 Siemens 10/015 1

Additional components Circuit diagrams Graphic symbols Auxiliary switches (AS) 13 1 1 5ST3010 5ST3013 5ST3010-13 3 1 5ST3011 5ST301 5ST3011-11 1 1 5ST301 5ST3015 5ST301- Auxiliary switches (AS) for RCCBs for 5SM3 up to 80 A 1 13 1 11 3 13 Auxiliary switches (AS) for RCCBs for 5SM3, 100 A, 15 A, 3P+N 3 11 1 1 1 1 1NO + 1NC NC NO 1NO + 1NC Fault signal contacts (FC) 13 1 1 5ST300 5ST300-13 3 1 5ST301 5ST301-11 1 1 5ST30 5ST30- Shunt trips (ST) Undervoltage releases (UR) Remote controlled mechanisms (RC) C C1 D1 U< D 13 3 1 D1 U v D M P N 1 3 ON OFF I01_1071a P, N: Supply voltage 1: Return conductor : ON command 3: OFF command 5ST3030 5ST3031 5ST300 5ST301 5ST30 5ST303 5ST30 5ST305 Leakage current measurement device 1 3 5 N V 1 MΩ/V N I01_07078a More information Gossen-Metrawatt offers suitable test devices for RCCB function tests and for testing protective measures. Information is available at: Gossen-Metrawatt GmbH Thomas-Mann-Str. 1-0 D-9071 Nuremberg Tel. 009 (0)/8 0-111 Fax 009 (0) 9 11/8 0-777 www.gmc-instruments.com email: info@gmc-instruments.com Siemens 10/015

Overview RC units are used in all supply systems up to 0/15 V AC. Devices of type AC trip in the event of sinusoidal AC residual currents, type A also trips in the event of pulsating DC residual currents. In addition, RC units, type F also detect residual currents with mixed frequencies up to 1 khz. RCCBs with a rated residual current of maximum 30 ma are used for personnel, material and fire protection, as well as for protection against direct contact. Devices with a rated residual current of maximum 300 ma are used as preventative fire protection in case of insulation faults. RC units are combined with miniature circuit breakers with A, B, C and D characteristics, provided that these are available in the MCB range. The two components are simply plugged together without the need for any tools. They then form a combination of RCCB and miniature circuit breakers for personnel, fire and line protection. The dimensioning of the rated residual current depends on the size of the plant. 5SM RC units Benefits Our wide variety of RC unit types and comprehensive range of miniature circuit breakers offer a huge spectrum of combinations for all applications Instantaneous type A devices have a surge current withstand capability with current waveform 8/0 μs of more than 1 ka, super resistant of more than 3 ka and selective of more than 5 ka. This ensures safe operation All additional components for miniature circuit breakers can be retrofitted on the right-hand side All 100 A and 15 A RC units offer external remote tripping over terminals Y1/Y. This supports implementation of central OFF circuits Both components can be simply plugged into each other and secured with captive metal brackets no tools required. This saves considerable time when mounting Siemens 10/015 3

5SM RC units Technical specifications 5SM Standards IEC/EN 1009-1 (VDE 0-0), IEC/EN 1009--1 (VDE 0-1), IEC/EN 153 (VDE 0-30), IEC/EN 3 (VDE 0-0) Surge current withstand capability Type A with current waveform 8/0 µs Acc. to EN 000- (VDE 03-) - Instantaneous ka > 1 - Super resistant ka > 3 -Selective ka > 5 Type F with current waveform 8/0 µs Acc. to EN 000- (VDE 03-) ka > 3 Minimum operational voltage for test function operation V AC 195 Rated voltage U n V AC 30... 00 Rated frequency f n Hz 50... 0 Rated currents I n A 0.3... 1; 0.3... 0; 0.3... 3; 80... 100 Rated residual currents I Δn ma 10, 30, 100, 300, 500, 1000 Insulation coordination Overvoltage category III Pollution degree Terminal conductor cross-sections Up to I n = 3 A mm 1.5... 5 At I n = 80... 100 A mm.0... 50 Terminal tightening torque Nm.5... 3.0 Mains connection Either top or bottom Mounting position (on a standard mounting rail) Any Degree of protection Acc. to EN 059 (VDE 070-1) IP0, if the distribution board is installed, with connected conductors Touch protection Acc. to EN 507 (VDE 00-51) Finger and back-of-hand safe Service life Average number of switching cycles > 10000 switching cycles Storage temperature C -0... +75 Ambient temperature C -5... +5, -5 marked with Resistance to climate Acc. to IEC 008--30 8 cycles (55 C; 95 % rel. air humidity) CFC and silicone-free Yes Power losses per conducting path under rated current load Number of poles Rated current Rated residual current I Δn [A] 1 0.01.5 /3/ 0 0.03 3. 3 0.03. 0 0.3/0.5/1 1.9 3 0.1/0.3/0.5/1 3.0 / 80 0.3.8 80 0.3/1.0 100 0.3.0 100 0.3/1 5.0 Power losses per conducting path P v [W] Siemens 10/015

5SM RC units Dimensional drawings RC units for 5SY 5 90 8 I01_083a 3 5 71 10,5 P 3P P 5,3 1 10 RC units for 5SP 3 Y1Y 90 Y1 Y 5 90 5 90 I01_07 /1 /3 T I01_071b /1 /3 /5 T 8/7 180 7 180 7 P P Circuit diagrams Graphic symbols RC units for 5SY 1 3(N) 1 3 5 1 3 5 7(N) I01_130b /1 /3 I01_131b /1 /3 /5 I01_13b /1 /3 /5 8/7 8 P 3P P RC units for 5SP Y1 Y 1 3(N) Y1 Y 1 3 5 7(N) I01_133b /1 /3 I01_13b /1 /3 /5 8/7 8 P P Siemens 10/015 5

5SU1 RCBOs Overview RCBOs are a combination of an RCCB and a miniature circuit breaker in a compact design for personnel, fire and line protection. For personnel protection and fire protection, the residual current part of the type AC trips in the event of sinusoidal AC residual currents, type A also trips in the event of pulsating DC residual currents. In addition, RCBOs type F also detect residual currents with mixed frequencies up to 1 khz. RCBOs with a rated residual current of maximum 30 ma are used for personnel, material and fire protection, as well as for protection against direct contact. RCBOs with a rated residual current of 10 ma are primarily used in areas that represent an increased risk for personnel and in the outdoor installations of residential buildings. Devices with a rated residual current of maximum 300 ma are used as preventative fire protection in case of insulation faults. The MCB part of the RCBO protects lines against overload and short circuits and is available in characteristics B and C. Since DIN VDE 0100-10 came into effect in June 007, all socket outlet current circuits up to 0 A must now also be fitted with residual current protective devices with a rated residual current of max. 30 ma. This also applies to outdoor electrical circuits up to 3 A for the connection of portable equipment. In order to implement this protection, we recommend the national use of RCBOs with 30 ma. Assignment to each individual branch circuit helps prevent the undesired tripping of fault-free circuits induced by the accumulation of operation-related leakage currents or by transient current pulses during switching operations. Additional components of the 5SY miniature circuit breakers can be mounted at the side and carry out additional functions. For further details on additional components, see Catalog LV 10, chapter "Miniature Circuit Breakers". RCBOs comprise one part for fault-current detection and one part for overcurrent detection. They are equipped with a delayed overload/time-dependent thermal release (thermal bimetal) for low overcurrents and with an instantaneous electromagnetic release for higher overload and short-circuit currents. The special contact materials used guarantee a long service life and offer a high degree of protection against contact welding. Benefits For all versions Clear and visible conductor connection in front of the rear busbar facilitates controls Large and easily accessible wiring space enables easy insertion of conductor in the terminals The surge current withstand capability of over 1 ka ensures safe and reliable operation All additional components for miniature circuit breakers can be retrofitted on the right-hand side. For all 10 ka versions up to 0 A Integrated movable terminal covers located at the cable entries ensure the terminals are fully insulated when the screws are tightened. The effective touch protection when grasping the device considerably exceeds the requirements of BGV A3 The RCBOs can be quickly and easily removed from the assembly by hand if connections need to be changed. Timesaving replacement of parts as busbars no longer need to be freed from adjacent miniature circuit breakers. For all 15 A versions The RCBOs offer external remote tripping over terminals Y1/Y. This supports implementation of central OFF circuits. Siemens 10/015

5SU1 RCBOs Technical specifications Up to 0 A 15 A Standards IEC/EN 1009-1 (VDE 0-0); IEC/EN 1009--1 (VDE 0-1) IEC/EN 153 (VDE 0-30); IEC/EN 3 (VDE 0-0) Rated voltages U n V AC 30 00 Rated frequency f n Hz 50... 0 Rated currents I n A, 8, 10, 13, 1, 0, 5, 3, 0 15 Rated residual currents I Δn ma 10, 30, 100, 300 30, 300, 1000 Rated breaking capacity ka / 10 10 Energy limitation class 3 -- Surge current withstand capability, type A With current waveform 8/0 µs Acc. to EN 000- (VDE 03-) - Instantaneous ka > 1 - Super resistant ka > 3 -- -Selective ka > 5 Type F with current ka > 3 -- waveform 8/0 µs Minimum voltage for operation of the test equipment V AC 195 Insulation coordination Overvoltage category III Pollution degree Terminal conductor cross-sections Solid and stranded mm 0.75... 35... 50 Finely stranded with end sleeve mm 0.75... 5... 35 Terminal tightening torque Nm.5... 3.0 3.0... 3.5 Mains connection Top or bottom Mounting position (on a standard mounting rail) Any Degree of protection Acc. to EN 059 IP0, if the distribution board is installed, with connected conductors (VDE 070-1) Touch protection Acc. to EN 507 Finger and back-of-hand safe (VDE 00-51) Service life Average number of switching cycles > 10000 Storage temperature C -0... +75 Ambient temperature C -5... +5, -5 marked with Resistance to climate Acc. to IEC 008--30 8 cycles (55 C; 95 % rel. air humidity) CFC and silicone-free Yes Power losses Note: All data under loading with rated current I n. Rated current I n [A] Rated residual current I Δn [ma] Power losses per conducting path P v [W] Characteristic B Characteristic C 10.8. 30... 300.7 1.9 8 30... 300 -- 1. 10 10.. 30... 300 1.8 1. 13 10 3.5 3.3 30... 300.. 1 10.7.5 30... 300 3.0.8 0 30... 300 3.7 3.3 5 30... 300 5.1 5.1 3 30... 300 5.7 5.7 0 30... 300 7.8 7.8 Siemens 10/015 7

5SU1 RCBOs 8 Siemens 10/015

5SU1 RCBOs Characteristic curves Tripping characteristics according to EN 1009-1 (VDE 0 Part 0) Tripping characteristic B Tripping characteristic C Tripping time Minutes Seconds 1.13 10 0 0 0 10 1 0 0 10 1 0. 0. 0. 0.1 0.0 0.0 0.0 1.5 I01_1353 Tripping time Minutes Seconds 1.13 10 0 0 0 10 1 0 0 10 1 0. 0. 0. 0.1 0.0 0.0 0.0 1.5 I01_135 0.01 1 1.5 3 5 8 10 15 0 Multiple of rated current 30 0.01 1 1.5 3 5 8 10 15 0 Multiple of rated current 30 Line protection mainly in outlet circuits; no proof required regarding personal safety General line protection, especially advantageous with higher starting currents (lamps, motors, etc.) Tripping characteristics at ambient temperature 30 C Tripping characteristic Standards Thermal release Electromagnetic release Test currents: Test currents: Small Large Tripping time Hold Latest Tripping time test current test current I n 3 A I n > 3 A tripping I 1 I t I I 5 t B IEC/EN 1009-1 1.13 I n > 1 h > h 3 I n 0.1 s VDE 0 Part 0 1.5 I n < 1 h < h 5 I n < 0.1 s C 1.13 I n > 1 h > h 5 I n 0.1 s 1.5 I n < 1 h < h 10 I n < 0.1 s In the case of an ambient temperature other than 30 C, the current values of the delayed tripping operation change by approx. 5 % per 10 K temperature difference. They rise in case of temperatures lower than 30 C and fall in case of temperatures higher than 30 C. If more than one electrical circuit is loaded in a series of MCBs or RCBOs, the resulting increase in ambient temperature affects the characteristic curve. In this case, it is necessary to take into account an additional correction factor, specific to the rated current of the RCBO. Number 1... 3... > 7 Correction factor K 1.00 0.90 0.88 0.85 Breaking capacity Particular demands are made on the MCB part of the RCBO with regard to breaking capacity. The values are standardized and are determined according to the test conditions of EN 1009-1 (VDE 0 Part 0). The most common values are 000 and 10 000. Siemens 10/015 9

5SU1 RCBOs Let-through I t values Rated switching capacity 5SU1, 000 A Characteristic B Characteristic C [ka s] 10 10 1 5/3/0 A 13/1/0 A 10 A A I01_1551 [ka s] 10 10 1 0/5/3/0 A 13/1 A 8/10 A A 3/ A A 1, A I01_15513 10 0 10 0 1 A 0,5 A 10-1 10-1 810 0 810 1 810 p [ka] 10-1 0,3 A 10-10 - 810-1 810 0 810 1 810 p [ka] Rated breaking capacity 5SU1, 10000 A Characteristic B Characteristic B [ka s] 10 10 1 10 0 5/3/0 A 13/1/0 A 10 A 10-1 10-1 810 0 810 1 810 p [ka] A I01_1551 10 3 10 10 1 100/15 A 80 A 8 10 0 8 10 1 I01_101a 30 Siemens 10/015

Rated breaking capacity 5SU1, 10000 A Characteristic C Characteristic C 5SU1 RCBOs [ka s] 10 10 1 10 0 0/5/3/0 A 13/1 A 8/10 A A 3/ A A 1, A 1 A 0,5 A I01_15515 [ka s] 10 3 10 100/15 A I01_1551 10-1 0,3 A 10 1 8 10 0 8 10 1 p [ka] 10-10 - 810-1 810 0 810 1 810 p [ka] Characteristic D 10 3 I01_15517 10 100 A 10 1 8 10 0 8 10 1 Siemens 10/015 31

5SU1 RCBOs Dimensional drawings I01_1350a 5 90 3 5 7 70 1P+N, up to 0 A P, up to 0 A 117 198 7 70 max 7 I01_139a 5 90 P, 15 A P, 15 A Handle coupler I01_111a, Ø 5, 17,9 Circuit diagrams Graphic symbols 1 N 1 3 N I01_135a I01_13a 1P+N, up to 0 A P, up to 0 A Y1 Y 1 3 Y1 Y 1 3 5 7(N) I01_137a /1 /3 /5 8/7(N) I01_138a P, 15 A P, 15 A 3 Siemens 10/015

5SU1 RCBOs More information Selectivity of RCBOs/fuses Distribution systems are usually set up as radial networks. An overcurrent protection device is required for each reduction of the conductor cross-section. This produces a series connection staggered according to rated currents, which should, if possible, be "selective". Selectivity means that, in the event of a fault, only the protective device that is directly next to the fault source in the current path is tripped. This means that current paths in parallel can maintain a power flow. In the case of RCBOs with upstream fuses, the selectivity limit depends largely on the current limitation and tripping characteristics of the RCBO and the melting I t value of the fuse. This produces different selectivity limits for RCBOs with different characteristics and rated switching capacity. The following tables provide information on the short-circuit currents up to which selectivity exists between RCBOs and upstream fuses according to DIN VDE 03 Part 1. The values specified in ka are limit values that were determined under unfavorable test conditions. Under normal practical conditions, you can often expect considerably better values, depending on the upstream fuses. Limit values of selectivity of RCBOs/fuses in ka Downstream RCBOs Upstream fuses I n [A] 1 A 0 A 5 A 35 A 50 A 3 A 80 A 100 A 15 A B characteristic 5SU1.5 0. 0.7 1.1.0.1 -- 10 -- 0.5 0.75 1.. 3.. -- 13 -- 0.5 0.7 1.3.0.7 3. -- 1 -- 0.5 0.7 1.3.0.7 3. -- 0 -- -- 0.7 1.3.0.7 3. -- 5 -- -- -- 1.3.0.7 3. -- 3 -- -- -- --.0.7 3. -- 0 -- -- -- -- 1.8.7 3. -- C characteristic 5SU1.5 0.35 0.55 0.8 1.5.8.7 -- 8 -- 0.5 0.7 1..3 3.3. -- 10 -- 0.5 0.7 1..3 3.3. -- 13 -- 0. 0. 1..0 3.0 3.5 -- 1 -- 0. 0. 1..0 3.0 3.5 -- 0 -- -- 0. 1..0 3.0 3.5 -- 5 -- -- -- 1..0 3.0 3.5 -- 3 -- -- -- --.0.8 3.5 -- 0 -- -- -- -- 1.8.8 3.5 -- r Rated breaking capacity according to EN 1009-1 000. B characteristic 5SU1.5 0.5 0.7 1.1. 5.0 10 -- 0.55 0.8 1.5.8. 7.0 13 -- 0.5 0.75 1..3 3.9.0 1 -- 0.5 0.75 1..3 3.9.0 0 -- -- 0.75 1..3 3.9.0 5 -- -- -- 1..0 3.1.5 8.0 3 -- -- -- --.0 3.1.5 8.0 0 -- -- -- -- 1.8.8.0 7.0 C characteristic 5SU1.5 0. 0. 0.9 1.7 3.3.5 8 -- 0.5 0.8 1.5.7 5.0 7.0 10 -- 0.5 0.8 1.5.7 5.0 7.0 13 -- 0.5 0.7 1.3.3.0 5.0 1 -- 0.5 0.7 1.3.3.0 5.0 0 -- -- 0. 1..0 3.. 8.0 5 -- -- -- 1..0 3.. 8.0 3 -- -- -- -- 1.8.8 3. 7.0 0 -- -- -- -- 1.8.8 3. 7.0 r Rated breaking capacity according to EN 1009-1 10 000. Siemens 10/015 33

5SM AFD units Overview Characteristics The Siemens portfolio of protective devices has been proving itself in the field for many years. This range of fuses, miniature circuit breakers and residual current protective devices has now been expanded to include AFDDs (arc fault detection devices). These AFDDs detect arcing faults caused by serial faults or loose contacts or as a result of insulation faults that enable contact between phase conductors or between phase and protective conductors. They therefore offer extremely effective protection against fires started by electrical faults. Generally speaking, arcing faults in the circuit can result from damage to cables and other insulations and from contamination. Insulation faults result, for example, from vibrations, thermal expansion and contraction, mechanical loads and aging. A distinction is made between 3 types of arcing faults: Serial arcing faults This is caused by breaks in the conductor or when a loose contact is in the circuit in series with the load. As the current flow in such cases is always lower than the operational load current, miniature circuit breakers and residual current protective devices are unable to detect such faults and initiate tripping. The AFDD is specially designed to detect the specific characteristics of these arcing faults, and it reliably disconnects the affected circuit as soon as the limit values are exceeded. Parallel arcing faults between phase conductor/neutral conductor or phase conductor/phase conductor These are caused by electric arcs resulting from damage to the insulation that permits contact between the two conductors. In this case, the level of current is determined by the impedances in the circuit. Depending on the rated current of the overcurrent protection device (for instance a miniature circuit breaker), this can be disconnected. However, if the impedance in the circuit is too high to reach the trip current of the overcurrent protection device, no tripping takes place. AFDDs disconnect the currents of arcing faults upwards of.5 A, thus providing reliable protection in the case of such faults. Parallel arcing faults between phase conductor/protective conductor Arcing faults against the protective conductor are reliably detected and shut down by residual current protective devices. Residual current protective device with rated residual currents up to max. 300 ma have already been providing effective fire protection in such cases for many years. AFDDs also detect these arcing faults and provide adequate fire protection where no residual current protective device is implemented. Closing of the safety gap on the IEC market Type of fault Serial L N Parallel Phase-Neutral/ Phase-Phase L N LOAD LOAD Parallel Phase-Protective conductor L N LOAD Protection devices MCB RCD AFDD New AFDD AFDD New New AFDD Arc fault detection device MCB Miniature circuit breaker RCD Residual current protective device RCBO Residual current operated circuit breaker with overcurrent protection RCBO New AFDD Preventing undesired tripping operations Electric arcs and high-frequency signals occur during normal operation in networks with multiple electrical loads (e.g. electric motors, light switches, dimmers). The AFDD must not break the circuit in such cases. Thanks to the sophisticated detection logic of our AFDDs, they are able to clearly distinguish between normal operational interference signals and hazardous arcing faults. I01_19188 3 Siemens 10/015

5SM AFD units Product versions and application Siemens offers two product versions, which can be used in various combinations with a range of 1MW/MW miniature circuit breakers and/or RCBOs up to max. 1 A rated current. This simplifies product selection and reduces inventory, while enabling coverage of every conceivable application. It also means that our tried and tested protective devices (MCBs, RCBOs) can be combined with the new functionality provided by arc fault protection. In particular, the version with RCBOs offers a protective device that provides comprehensive personnel, short-circuit, overload and fire protection in a single device. The version combined with a compact miniature circuit breaker in 1 MW is a space-saving alternative that is ideal for retrofitting. Whether auxiliary switch or fault signal contact the 5SM AFDD units can be combined at random with the versatile range of additional components from the familiar portfolio of 5SY miniature circuit breakers and 5SU1 RCBOs. This also enables connection to a higher-level I&C system. The 5SM AFDD units can be connected easily and quickly. The miniature circuit breakers or RCBOs can be mounted quickly and simply by just snapping them onto the mounting rail without the need for tools. For a fast and reliable power supply, the infeed can be implemented via a busbar assembly. The AFDDs are primarily intended for protection of final circuits in cases where There is an increased risk of fire due to flammable materials being stored or processed (e.g. wood processing) Flammable building materials are in use (e.g. wood paneling) Valuable goods need to be protected (e.g. museums) There are rooms in which a fire might not be noticed immediately (e.g. bedrooms, children's bedrooms) Status displays and self tests In order to facilitate fault locating in the event of tripping, AFDDs have a display with 5 LEDs that provide information on the cause of tripping (serial/parallel arcing faults, overvoltage). The sophisticated detection electronics system also automatically checks the functionality of the AFDD. If the self-monitoring process detects a fault, the AFDD switches off and displays the corresponding indication. Arc fault detection device (5SM) fault indication Device functional Restricted device function (background noise marginal) Serial or parallel arcing faults detected Overvoltage (> 75 V) Self-test failed No power supply Integrated overvoltage protection Depending on the load distribution in the three-phase current system, an interruption on the infeed side of the neutral conductor may cause a shift of the neutral point and thus an increase in voltage between the phase conductor and the neutral conductor. This increase in voltage can damage the loads or present a fire risk due to overloaded components. In order to ensure all-round protection, the AFDDs are fitted with an overvoltage release that disconnects when the voltage between phase conductor and neutral conductor exceeds 75 V, thus isolating downstream loads from the hazardous line voltage. Technical specifications Standards Future standard IEC/EN 0 Versions -pole Rated voltage U n V 30 Rated current I n A Up to 1 Rated frequency Hz 50 Mains connection Bottom Tripping in the event of overvoltage V > 75 Degree of protection Acc. to EN 059 IP0, with connected conductors (VDE 070-1) Surge current withstand capability With current waveform 8/0 µs ka 3 Touch protection Acc. to EN 507 (VDE 00-51) Finger and back-of-hand safe Terminal tightening torque Nm.0....5 Terminal/conductor cross-sections Solid and stranded mm 0.75... 1 Finely stranded with end sleeve mm 0.75... 10 Overvoltage category III Mounting position Any Service life average number of switching cycles > 10000 Ambient temperature C -5... +0, marked with -5 Storage temperature C -0... +75 Resistance to climate Acc. to IEC 008--30 8 cycles (55 C; 95 % rel. air humidity) Pollution degree CFC and silicone-free Yes Power losses W 0. Siemens 10/015 35

5SM AFD units Dimensional drawings 35,3 17,9,8 8,5 17,9 5,5,8 8,5 1 I01_1888 I01_18883 95 95 8,1 8 1 5SM011-1 5SM01-1 Circuit diagrams LOAD L N AFD L N I0_03 LINE 3 Siemens 10/015

Overview The Siemens portfolio of protective devices has been proving itself in the field for many years. This range of fuses, miniature circuit breakers and residual current protective devices has now been expanded to include the 5SM AFD units. These AFD units detect arcing faults that may be caused, for example, by serial faults or loose contacts. Technical specifications 5SM AFD units for PV applications Benefits Easy to install and retrofit Visual and acoustic indication of arcing faults when a fault is detected Resetting of the arcing fault indication Developed according to UL 199B Cost savings thanks to easy installation Integration into an external safety system for safe system disconnection 5SM09-1 Standards IEC 03-7-71, UL199B Category PV AFD Type 1 (UL 199B) Rated current I n A 0 Rated voltage DC V 1000 Tripping current for serial arcs A 1 0 Tripping voltage DC V Min. 100 Supply voltage DC V Terminal conductor cross-sections String connection mm.5 to 10 Supply voltage connection mm.5 Signal connection mm.5 Terminal tightening torque String connection Nm Max. 3.5 mm² Supply voltage connection Nm Max. 1.5 mm² Signal connection Nm Max. 1.5 mm² Current consumption Active ma 10 Passive ma 0 Operational current (load) alarm relay (15 V AC) A 0.3 Operational current (load) alarm relay (30 V DC) A 1 Overvoltage category III Supply voltage connection Bottom Mounting position Any Number of poles 1 Degree of protection Acc. to EN 059 (VDE 070-1) IP0, with connected conductors Acc. to EN 507 (VDE 00-51) Finger and back-of-hand safe CFC and silicone-free Yes Pollution degree Storage temperature C -0... +75 Ambient temperature C -0 +50 Resistance to climate Acc. to IEC 008--30 8 cycles (55 C; 95 % rel. air humidity) Siemens 10/015 37

5SM AFD units for PV applications Dimensional drawings 8 100 110 3 5SM09-1 Circuit diagrams electronics + V DC 0 V C IN NC NO OUT 1 1 3 38 Siemens 10/015

5ST busbars for modular installation devices Overview -pole 5SM3 RCCBs are bus-mounted either together or in combination with miniature circuit breakers. RCCBs with an N conductor connection on the left-hand side facilitate installation because standard busbars are used, as those used for bus mounting miniature circuit breakers. Busbars in 10 mm and 1 mm versions are available. The extremely flexible 5ST3 busbar system with fixed lengths also enables installation in any lengths as the busbars can be overlapped. Benefits Connection of miniature circuit breakers to -pole RCCBs with N connection right and 3-phase busbar, using busbar specially designed for this application. No cutting or end caps required. No further need for time-consuming tasks, such as cutting, cutting to length, deburring, cleaning of cut surfaces and mounting of end caps. Any free pins on the busbars can be made safe by covering with touch protection. If several RCBOs are bus-mounted together, this is implemented with -phase busbars, which are thus used as 1+N busbars. Connection of miniature circuit breakers to -pole RCCBs with N connection left, with 3-phase busbar that can be cut. No additional items to be stored and busbars that are always available. Connection of 1P+N RCBOs with two-phase busbar. No cutting or end caps required. Bus-mounting of residual current protective devices on busbar (3-phase +N) that can be cut. A proven and frequently used application. Siemens 10/015 39