TESTING T3-61. IMPULSE GENERATOR 1,2/50 µs, 12 kv IEC TEST EQUIPMENT

Similar documents
Surge Current Generators PG **-****

Technical Specification

Solid-state Timer H3YN

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

MEASURING AND TESTING INSTRUMENTS

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Surge Protection for Surveillance Systems

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

RMCN22BD Analog Converter ma - for Zelio Analog

Model A Mini AC/DC Clamp Meter. User's Guide

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Proposal for Ethernet IEEE802.3 isolation requirements Rev.1

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-ERD.12

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

User's Guide. Extech AM A AC Analog Clamp Meter

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

2 in 1 LAN Tester and Multimeter Model:

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Model Number Structure

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Residual overvoltage relay

Electronic timer CT-AHD.22

93 SERIES. Timed socket for 34 series 93.68/93.69

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

QUINT-BUFFER/24DC/24DC/40

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

PHOENIX CONTACT - 07/2006

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

M-Door RANGE. Control, signalling and plug-in

Mini Digital Multimeter

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

10/100Base-TX Industrial Ethernet Extender

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

TM3TI8T module TM3-8 inputs temperature

DC561, digital input/output module,

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Universal Power Supplies

Voltage Current Front-mounting bracket

Power supplies.

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

Earth-fault Relay SPAJ 110 C. Product Guide

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL


NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

TM3TI4 module TM3-4 inputs temperature

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

AI561 Analog Input Module

Model Number Structure

Feeder protection relay SPAA 121 C. Product Guide

Contact protection relay

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Model Number Structure

Industrial Power Supplies

DC562, digital input/output module,

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Electronic timer CT-ARS.11

TM3TI4 module TM3-4 inputs temperature

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Autodaptive Capacitor Control M 2501B

Electronic timer CT-ERS.21

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

ABS2EC01EB input interface module mm - solid state - 24 V DC

Industrial Power Supplies

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TM3AI4 module TM3-4 analog inputs

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Transcription:

Testing d.o.o., Tržaška cesta 2 SI-1000 LJUBLJANA, SLOVENIA / EUROPE Tel.: +386 1 426 2199, Fax: +386 1 421 0366 E-mail: mail@testing.si http://www.iectestequipment.eu TESTING T3-61 IMPULSE GENERATOR 1,2/50 µs, 12 kv IEC TEST EQUIPMENT

KEYWORDS IMPULSE GENERATOR 1,2/50 µs, IEC TEST EQUIPMENT, IEC 60335-1, IEC 60065, 60950, 61180-1, 61180-2, IEC 61010, EN, UL COMPLIANCE It is constructed in compliance with IEC 60335-1, IEC 60065, 60950, 61180-1, 61180-2, IEC 61010,... INTRODUCTION T3-61 1,2/50 IMPULSE GENERATOR is intended for performing dielectric tests with impulse voltage on low-voltage equipment. It creates impulses with a virtual front time of 1,2 µs and a virtual time to half-value of 50 µs. Samples are tested by (high) voltage surges. It is constructed in compliance with the following standards: IEC 60335-1: Household and similar electrical appliances Safety Part 1: General requirements: Clause 14 Transient overvoltages IEC 60950-1: Information technology equipment Safety Part 1: General requirements: Annex N: Impulse test generators IEC 61180-1: High-voltage test techniques for low-voltage equipment; Part 1: Definitions, test and procedure requirements IEC 61180-2 High-voltage test techniques for low-voltage equipment - Part 2: Test equipment We designed IMPULSE GENERATOR with the following goals: Safety Reliability Ease of operation Ergonomical design The BOLD features below are some of advantages that were introduced to reach these goals. WWW.IECTESTEQUIPMENT.EU IEC TEST EQUIPMENT Page 2

MAIN FEATURES Ergonomically designed. Transparent acrylic 10 mm thick door and side panels enable observing of tested sample during the test, and protection of operator in case that due to the energy released during a surge a sample bursts (small explosion) Test cabinet bottom is 20 mm thick Two voltage generators separate for each polarity High voltage switching systems with electromagnets for better safety Two door safety protection switches surge can only be applied when doors are closed V-meter enables observing and adjusting surge voltage Internal voltage divider 10:1 with outside BNC (to connect a oscilloscope with HV probe) HV oscilloscope probe Variable ratio transformer with knob for voltage adjustment 400 12 000 V DC Push button CHARGE + for positive charging polarity Push button CHARGE - for negative charging polarity Illuminated push button DISCHARGE for activating the surge Mains switch with fuse Anodized aluminum front plate, with inscriptions that clearly explain the function of each component on the front plate Sample connection terminal sockets are located inside insulated protecting test cabinet Two port holes, with plugs, for possibility of connecting bigger samples in external test cabinets Auto-detect connector, for connecting external door (protection) switch if customer uses other/bigger external test cabinet WWW.IECTESTEQUIPMENT.EU IEC TEST EQUIPMENT Page 3

DESCRIPTION Apparatus consists of control unit and test cabinet, which is mounted on top of control unit. CONTROL UNIT Control unit is built in compact case. Inside control unit is a mains transformer, variable ratio transformer, two voltage generators, voltage measuring system, 10:1 voltage divider for outside HV probe (with a ratio 100:1), high voltage switching systems and electric circuit as per standard requests. On the front plate are located mains switch with fuse and appliance inlet, voltage adjustment knob, voltmeter, + charge push button, - charge push button, discharge push button and BNC measuring output. TEST CABINET On the top of control unit is located transparent test cabinet (isolated housing). Test cabinet has a body and a cover. The cover of test cabinet is protected with two safety door switches so that testing is not possible if the cover is opened. Due to the transparency of test cabinet monitoring of sample is enabled. Test cabinet also provides eye protection in case that the sample bursts/explodes. Inside the test cabinet are located terminal sockets for connecting the sample. On the side of test cabinet are two blind plugs, that can be removed and through them the HV cables can routed to the bigger samples that would not fit inside the test cabinet (to external bigger test cabinet not included, or to other protected area). On the front plate of control unit is also located auto-detect connector, for connecting external door (protection) switch(es), if customer uses other/bigger external test cabinet. for testing bigger samples. WARNING Only operators that understand the risks of HV testing can perform HV tests. WWW.IECTESTEQUIPMENT.EU IEC TEST EQUIPMENT Page 4

DESIGN Table top apparatus, two units: CONTROL UNIT: solid case, Non-sensitive, scratch-resistant surfaces through powdercoating, side panels, Al extrusion, RAL 7016, Frame, Al die-cast, RAL 7016, Base and cover, AI, 1.5 mm, RAL 9006, with GND/earthing connection, case feet with anti-slip protection, front plate and rear panel anodized aluminum 2,5 mm. Internal and external dimensions in accordance with: IEC 60297-3. Type of protection IP 20 in accordance with IEC 60529, Protective GND/earthing connections in accordance with: IEC 61010, DIN EN 50178 / VDE 0160, DIN EN 60950 / VDE 0805, DIN EN 61010-1 / VDE 0411 part 1, DIN EN 61010-1A2 / VDE 0411 part 1/A1. TEST CABINET: acrylic glass, bottom 20 mm thick, black, all other sides 10 mm thick, transparent. Cover transparent with acrylic handle, on two stainless steel hinges and protected by 2 safety switches. On the right side wall are two holes with insolating plugs that can be removed. TECHNICAL SPECIFICATION Supplying voltage Power consumption 230V, 50Hz / other optional 650 VA Output voltage surge 400V-12kV, adjustable V-meter 0-15 kv DC, 4 1/2 digit 2,5 % FS HV oscilloscope probe max. 1500 V, 300 Mhz bandwidth, ratio 100:1 Capacitor 1µF Virtual impedance 12 ohms Minimum charging time 3 seconds (as per standard request) Waveform 1.2/50µs BNC output 10:1 Dimensions Control unit WxDxH 470 x 490 x 285 mm Test cabinet WxDxH 420 x 300 x 250 mm OTHER CONDITIONS Warranty: 2 years Support by E-mail: support@testing.si On line Skype VIDEO Support: Testing_support, matejsimonic We will be glad to help you solve your problems and to hear any feedback from you. WWW.IECTESTEQUIPMENT.EU IEC TEST EQUIPMENT Page 5