MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Similar documents
VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

SK-1011-SQ Digital Access Keypad with 5A Relay Output

Digital Keypad Introduction

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

RFID/Digital Access Control Keypad

DG-800 Stand-Alone Proximity Reader Instruction Manual

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

SK-1011-SDQ Access Control Keypad. Manual

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

212iL Rev. 1.1

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Stand-alone Proximity Access Control

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

CM-500 SK 500 USER CODES KEYPAD

AS Keypad User Manual

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

9212i INSTALLATION. Stand-Alone Keypad. Instructions

User Manual. PCKeypad Wireless Keypad

RBR-SB-KTZ001 LAR 2. User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

U-FLASH Setup Guide U-FLASH.

Two Door Controller GEN-045

INTELLIKEY. Mini-DCU Installation Manual GENIUS AT YOUR FINGERTIPS. 1 rev

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

AirTest Model CN9000 Series Sensor Controller

GEM-ACM1D Access Control Accessory INSTALLATION INSTRUCTIONS

Click Save to return to the main Setup screen.

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

Waterproof. Keypad/Reader/Controller

KP2000E/EM Series Style Keypad

W3-H Waterproof Keypad/Reader/Controller

BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Installation Instructions

Installing Keypad and Backplate

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

FTK5 PROXIMITY KEYPAD

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

SHENZHEN Lejing INDUSTRY DEVELOPMENT CO.LTD Whatsapp:

CM-110SK Standalone Keypad Installation Instructions

VIDI-AC-2CS Access Controller/ Reader

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

DS-8a. CircuitWerkes. Technical Manual. Touchtone Sequence Decoder

Single Door Standalone Access Control User Manual

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

DS-8. CircuitWerkes. Technical Manual. Touchtone Sequence Decoder

PAC2 Dual Door Access Controller

PAC1 Door Access Controller

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

PAC1 Door Access Controller

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

Installation and User Manual

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

180 Series Keypad. Handbook. Revision 2.1

DTMF-4HC. DTMF decoder board with four high current relays. Copyright 2004 Intuitive Circuits, LLC

Outdoor Stand-Alone Weatherproof Keypads

Specifications: Features:

Stand-Alone Data Chip System

603 D E C T I n t e r c o m

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Installation manual CF8-W-Disp-AL

Connecting a Cisco Output Module

K44 Code lock. Technical manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

SK-1131-SPQ Access Control Keypad with Proximity Card Reader. Manual

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

703 F o u r B u t t o n D E C T I n t e r c o m

DSK-XXXXC DSK-XXXXP. Telephone Entry Door Intercom

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

791/793 Easy Entry Keypads

BC Digital Keypad. User Manual

User Manual SOLOgarde

DOLXFD1000B. Waterproof Access Control/Reader

Installation Instructions 4291 and 4292 Keypads

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

DTMF-8 Plus. Configurable DTMF decoder with eight high-current relays. Copyright 2002 Intuitive Circuits, LLC

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

IEI emerge MicroNode Install and Setup Guide. Contents

Fingerprint Access Control F1. User Manual

MODEL DK-26 DIGITAL KEYPAD SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

LIFE SAFETY PRODUCTS

The Single Dimmer Board

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

A-100 INDOOR STAINLESS STEEL KEYPAD WIRING & PROGRAMMING INSTRUCTIONS

Transcription:

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It is compatible with all electric locking devices. Alarm Controls 19 Brandywine Drive Deer Park, New York 11729 (800) 645-5538 www.alarmcontrols.com 1

INSTALLATION 1. Pass the wire harness through the opening in the back box. 2. Mount the back box to the door frame or wall. 3. Make all required wiring connections to the terminal blocks. 4. Place the keypad faceplate on the back box and secure with the screws provided. DAP JUMPER ON/OFF Power Input (12-24V AC/DC) Output Relay Egress Input (EG IN) Tamper Contact WIRING 12 or 24 AC or DC. AC power can be connected without observing polarity requirement. Connect DC power with polarity as indicated. SPDT dry contacts. Output can be programmed for latching or momentary operation. A normally-open request to exit station can be connected to this terminal and ground (-). Connecting the terminal to ground will operate the output in the same manner as a valid user code. Normally-closed output pair activated by the tamper switch if the keypad faceplate is removed from the back box. 2

KEYPAD INITIATION Keypad initiation must be done at the initial turn-on of the keypad. 1. Connect power to the keypad. 2. Put the keypad in Program Mode by entering 0 0 0 0. The keypad will beep twice and the yellow LED will be on and not 3. Enter 8 9 0 1 #. 4. The keypad will beep twice and the keypad initiation is complete. 5. Enter to exit Program Mode. The yellow LED will begin ENTERING A NEW INSTALLER CODE It is strongly recommended that the Installer Code be changed from the default 0 0 0 0. If the Installer Code is not known, please refer to the section on Direct Access to Programming. 1. Put the keypad in Program Mode by entering 0 0 0 0 or the current installer code. The keypad will beep twice and the yellow LED will be on and not 2. Enter 0 (4 to 8 digit new installer code) #. For example, to change the Installer Code to 1 2 3 4 you would enter 0 1 2 3 4 #. 3. The keypad will beep twice indicating that the new Installer Code has been accepted. 4. Enter to exit Program Mode. The yellow LED will begin PROGRAMMING MODE It is necessary to put the keypad in Programming Mode in order to access all keypad configuration settings. 2. Enter to exit Program Mode. The yellow LED will begin PROGRAMMING USER CODES User Codes are 4 to 8 digits long and must not be the same as the Installer Code. The keypad can store up to 100 User Codes. Each User Code has a Code Number. Code Numbers are two digits ranging from 00 to 99. 2. Enter (1) (Code Number) (User Code) #. For example, if you wish to assign a User Code of 6 7 8 9 to Code Number 01, you would enter 1 0 1 6 7 8 9 #. 3. Enter to exit Program Mode. The yellow LED will begin 3

OPERATION Enter a valid User Code to activate the Output Relay. The keypad must be in standby mode (yellow LED blinking). 1. Enter (User Code) #. For example, if the User Code is 1234 you would enter 1 2 3 4 #. DELETING USER CODES 2. Enter (1) (Code Number) #. For example, if you wish to delete the User Code in Code Number 02 you would enter 1 0 2 #. 3. Enter to exit Program Mode. The yellow LED will begin To delete all User Codes enter 8 9 0 1 #. MOMENTARY OR LATCHING OUTPUT MODES The Outputs Relay can be programmed for either momentary or latching operation. Momentary operation time can be set for between 1 and 999 seconds. The factory default momentary operation time is 2 seconds. 2. Momentary Mode - Enter 4 0 (output active time 1-999) # Latching Mode - Enter 4 1 # 3. Enter to exit Program Mode. The yellow LED will begin KEYPAD SILENT MODE The keypad beeper can be silenced. 2. Enter 8 3 0 #. 3. Enter to exit Program Mode. The yellow LED will begin To return the keypad to audible mode - 2. Enter 8 3 1 #. 3. Enter to exit Program Mode. The yellow LED will begin 4

AUTO OR MANUAL CODE ENTRY MODE When the keypad is programmed for Auto Entry Mode it is not necessary to terminate User Codes with the # during operation. However, in Auto Entry Mode the User Code must be the same length (4 to 8 digits) as the Installer Code. To put the keypad in Auto Entry Mode - 2. Enter 8 2 1 #. 3. Enter to exit Program Mode. The yellow LED will begin To return the keypad to Manual Entry Mode - 2. Enter 8 2 0 #. 3. Enter to exit Program Mode. The yellow LED will begin OUTPUT ANNUNCIATOR The keypad can be programmed to notify the user when the Output Relay is energized or the egress button has been pressed. To put the keypad in Output Annunciator Mode - 2. Enter 8 1 1 #. 3. Enter to exit Program Mode. The yellow LED will begin To take the keypad out of Output Annunciator Mode - 2. Enter 8 1 0 #. 3. Enter to exit Program Mode. The yellow LED will begin 5

KEYPAD LOCKOUT The keypad can be temporarily disabled to prevent unauthorized access by entering a user specified 4 to 8 digit Lockout Code. The red LED will light when the keypad is in Lockout Mode. The keypad can be taken out of Lockout Mode by entering the Lockout Code again. 2. Enter 5 1 # 3. Enter 2 1 (Lockout Code) #. For example, if you wish to assign a Lockout Code of 6 7 8 9, you would enter 2 1 6 7 8 9 #. 3. Enter to exit Program Mode. The red LED will illuminate. DIRECT ACCESS TO PROGRAMMING (DAP) If the Installer Code is forgotten, the Direct Access to Programming (DAP) utility can be used to put the keypad in Programming Mode. 1. Disconnect the power supply from the keypad. 2. Move the DAP jumper from the OFF to the ON position. 3. Reconnect the power supply to the keypad (keypad will start beeping). 4. Move the DAP jumper from the ON to the OFF position (keypad will stop beeping and the yellow LED will be on and not The keypad is now in Programming Mode. 5. A new Installer Code must now be entered. 6. Enter 0 (4 to 8 digit new installer code) #. For example, if you wish to change the Installer Code to 1 2 3 4 you would enter 0 1 2 3 4 #. 7. The keypad will beep twice indicating that the new Installer Code has been accepted. 8. Enter to exit Program Mode. The yellow LED will begin LED AND TONE INDICATORS The Green LED is on while Output Relay is activated. The Red LED is on while keypad is in Lockout Mode. The Yellow LED is described in the table below - Yellow LED Keypad Status Tone Indicator On Programming Mode None 1 Blink Successful Key Press 1 Beep 2 Blinks Successful Code Entry 2 Beeps 5 Blinks Error in Code Entry 5 Beeps Continuous Blinking Standby Mode None Continuous Blinking DAP Jumper not replaced Continuous Tone 6

BASIC WIRING DIAGRAM Use N/C contact for magnetic locks and fail-safe electric strikes. Use N/O contact for fail-secure electric strikes. The 1N4004 Diode must be used for DC powered electric strike applications. TAMPER SWITCH The Tamper Switch is Normally-closed when the keypad face plate is securely attached to the back box. Connect these terminals to an alarm panel if desired. CODES It is recommended that the Installer Code and User Codes be noted here for reference. Installer Code 7

Operating Voltage Active Current Draw Idle Current Draw Output Relay Contact Rating Output Contact Arrangement Dimensions SPECIFICATIONS 12 or 24 Volts AC or DC Auto-sensing 50 ma maximum @12VDC 65 ma maximum @24VDC 9 ma maximum @12VDC 17 ma maximum @24VDC 10A@28VDC Single Pole Double Throw 2.875 W x 4.5 L x 1.375 D 8 KP-100 Rev. B 5/14