Hardware Description

Similar documents
Enhanced RFC 2544 Test

Enhanced RFC 2544 Test

T-BERD /MTS 5800 Network Tester Ethernet Y.1564 Layer 2 Multiple Streams

XGT G Ethernet Tester

Viavi MTS/T-BERD G Software Update Instructions

Viavi MTS/T-BERD TB6000A V2 Mainframe & BERT Module Software Update Instructions

Viavi MTS/T-BERD TB6000A V1 Mainframe & BERT Module Software Update Instructions

The Essentials of Ethernet Service Activation

Viavi Solutions Ethernet Testing

1 Port Compact Sized Wirespeed Gigabit Ethernet Tester

Layer 4 TCP Performance in carrier transport networks Throughput is not always equal to bandwidth

IP SLA Service Performance Testing

MAX-860 Report PASS. Job Information. Equicom Méréstechnikai Kft. Report Title: EtherSAM (Y.1564)

IP SLA Service Performance Testing

Handheld Gigabit Ethernet Test Set

SmartClass Ethernet 10M-1G Ethernet Tester

The Essentials of Ethernet Service Activation

T-BERD /MTS-5800 Network Tester Ethernet RFC 6349 TrueSpeed Test - Local Unit

Arthur Moll BDM. Transport and Datacom. May Introducing EtherSAM. Ethernet Service Activation Methodology

Advanced Test Set for 10/100/Gigabit Ethernet

Central Office Testing of Network Services

Reducing Costs of Carrier Ethernet Performance Testing

MAX-860 Report FAIL. Job Information. Equicom Méréstechnikai Kft. Report Title: Circuit ID: Contractor Name: Customer Name: Operator Name: Comment:

SmartClass Ethernet 10 M 1 G Ethernet Tester

Technical Specification MEF 27. Abstract Test Suite For. May 20 th, 2010

MetroEthernet Options

Technical Specification MEF 6. Ethernet Services Definitions - Phase I. June 2004

TCP Throughput Testing

10GE Module. Key Features. Benefits. Quad-Speed, Tri-Port, Dual-Media Ethernet Tester. Get a Grip on 10M to 10G Ethernet Testing

T-BERD/MTS 5800 Network Tester Testing VOIP SIP Trunks

S2250/S3250 NETWORK INTERFACE DEVICE

Portable 2-Port Gigabit Wirespeed Streams Generator & Network TAP

CN-100 Network Analyzer Product Overview

Multi Service Port (MSP)

1 Gbps and 10 Gbps WAN Emulator IPNetSim

Nighthawk S8000 Gaming & Streaming Advanced 8-Port Gigabit Ethernet Switch User Manual

Quick Start Guide. System Release 1.0. Upgrade Notice Install Connectorized Radio Install Integrated Radio Power On Configure Units for Radio Link

POS on ONS Ethernet Cards

Schedule 2e. Schedule 2E Additional Terms for Carrier Ethernet Services Eng Lang v page 1 of 11

ISCOM2948GF-4C Intelligent Ethernet Service Aggregation

IP SLA Service Performance Testing

POS on ONS Ethernet Cards

CUSTOMER DATA FORMAT REQUIREMENTS

TCP Wirespeed Verify TCP Throughput up to 10G Using the T-BERD /MTS-6000A Multi- Services Application Module (MSAM)

EZ ETHERNET A SIMPLE, EASY-TO-CONNECT ALTERNATIVE FOR LOW-BANDWIDTH ETHERNET ACCESS

MPX100 Intelligent Ethernet Test Probe

Advanced Lab in Computer Communications Meeting 6 QoS. Instructor: Tom Mahler

Metro Ethernet Services A Technical Overview Ralph Santitoro

[[TYPE A QUOTE. Key Features. Handheld Dual 10G Ethernet

CMA Gigabit Ethernet Application. Applications

Performance Management Reporting User Guide for EPMR

XenaCompact TM Series

Technical Specification MEF 13. User Network Interface (UNI) Type 1 Implementation Agreement. November, 2005

10G ETHERNET MULTI FIELD TESTER

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 2

10G ETHERNET MULTI FIELD TESTER

ISCOM RAX 711 (B) Ethernet Demarcation Device

esam - Performance Assessment

Service Definition E-Line Service

Comparison of Ethernet Testers GL Communications Inc

1G and 10G Packet Ethernet Test Module

Carrier Ethernet Installation. the Path to Excellence

NETWORK SERVICES: ETHERNET WAN ETHERNET SERVICES PRODUCT PORTFOLIO SUMMARY DOCUMENT

T-BERD /MTS /100 G Transport Module

Layer 2 Tunnel. xconnect performance test

Overview of the ML-Series Card

Chapter 9. Ethernet. Part II

OTM G Packet Ethernet Test Module.

XTT benefits. Quad-Speed, Tri-Port, Dual-Media Ethernet Tester Version 1.3 Data Sheet. Now with Fibre Channel Testing!

Xena2544 (v2.15) Step by Step Guide

1. Press "Speed Test" to find out your actual uplink and downlink speed.

MX300 e-manual. Table of Contents. 1.0 Product Introduction. 2.0 About this User Manual. 3.0 Safety Information. 4.

Developing Standards for Metro Ethernet Networks

Product Technical Specification

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Configuring PFC QoS CHAPTER

Testing for SLA Compliance of business services over DOCSIS 3.1

AQ1300 MFT-10GbE 10G ETHERNET MULTI FIELD TESTER

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Dual Port Fiber 100 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based

Technical Specification MEF 14. Abstract Test Suite for Traffic Management Phase 1. November, 2005

8-Port Gigabit Ethernet Smart Managed Plus Switch with Integrated Cable Management User Manual

MPM-400G 400G Multi-Protocol Module

IEEE Resilient Packet Ring (RPR) Standards Update

Xena3918 (v1.8) Step by Step Guide

DApps-QoS Utility User s Manual

Highlights. Datasheet. defined E-Line and with specifications. Network Security. control, & Management. Advanced QoS.

NetComplete SAS Metro Ethernet Test and Troubleshooting

Configure Virtual LANs in Layer 2 VPNs

Recipient name Organisation Address Line 1 Address Line 2 Address Line 3. [Date] Dear [ ]

Configuring QoS CHAPTER

Managing Your Switches

Ethernet Tester PacketExpert 1 Gbps

MPLS AToM Overview. Documentation Specifics. Feature Overview

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Cisco Small Business Managed Switches

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Configuring QoS CHAPTER

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 3

GigE & 10GigE Ethernet Technology Overview & Testing Approaching

Transcription:

MTS/T-BERD - 5800

Hardware Description 2

User Interface 3

RFC 2544

RFC 2544 Test Procedure Select Test In the Select Test menu,,at the top left corner of the screen, choose one of the following: For 10BASE-T, 100BASE-T, or 1000BASE-T Electrical Ethernet testing: Ethernet 10/100/1000 RFC 2544 L2 Traffic P1 Terminate. For 100BASE-FX Optical Fast Ethernet testing: Ethernet 100M Optical RFC 2544 L2 Traffic P1 Terminate. For 1000BASE-SR, 1000BASE-LR, or other GigE Optical Testing: Ethernet 1GigE Optical RFC 2544 L2 Traffic P1 Terminate. For 10GBASE-SR, 10GBASE-LR, other 10GigE Optical Testing: Ethernet 10GigE LAN RFC 2544 L2 Traffic P1 Terminate. 5

RFC 2544 Test Procedure - Configure If this is the first time using the RFC2544 test and your unit does not have preloaded configuration files, tap the button next to Start a New Configuration (reset to defaults) and proceed to step 2. Otherwise, tap the button next to Load Configuration from a Profile Select the desired configuration, and tap. Tap to acknowledge successful load, tap the button, and tap the button next to Edit Configuration. 6

RFC 2544 Test Procedure - Symmetry In the Symmetry configuration screen, verify that Throughput = Symmetric and Measurements = Loopback, then tap the button. 7

RFC 2544 Test Procedure L2 Settings Option Value(s) Comment Frame Type DIX Encapsulation None or VLAN See Work Order Select LBM Traffic if the Test Mode Traffic or LBM loopback device is an ALU Traffic 7705. Select Traffic for all other loopback devices. VLAN ID See Work Order Option only displayed if User Priority 0 (lowest) Encapsulation = VLAN Source Type Factory Default Tap the Set Loop Type and MAC Enter MAC address Destination MAC of the loopback device Loop Type Unicast EtherType 0800 Auto-increment SA MAC Maint. Domain Level Enable Sender TLV No See work order. Set to same value as ALU 7705 No (unchecked) Addresses or Set MAC Addresses and LBM links to configure these settings. (See below) Options only displayed if Test Mode = Traffic Options only displayed if Test Mode = LBM Traffic 8

RFC 2544 Test Procedure Other Settings Use the or button at the bottom of the screen to advance through the wizard and configure the remaining settings as follows: Screen Option Value(s) Comment RFC 2544 Tests: Configuration Templates Do you want to use a configuration template? No RFC 2544 Tests: Select Tests RCF 2544 Tests Additional Tests Throughput, Latency, Frame Loss Packet Jitter 9

RFC 2544 Test Procedure Other Settings Bandwidth Unit L1 Mbps Maximum Bandwidth See Work Order Enter Committed Information Rate (CIR) RFC 2544 Tests: Utilization Frame Lengths Select 1 st, 4 th, and 8 th Frame Lengths. If the MTU is greater than 1518 (1522 with VLAN), also enter and select the frame length of the MTU. Deselect (uncheck) all other frame sizes. RFC 2544 Tests: Throughput Zero-in Process Measurement Accuracy JDSU Enhanced To within 1 Mbps 10

RFC 2544 Test Procedure Other Settings Test Procedure RFC 2544 Standard RFC 2544 Tests: Frame Loss Test Bandwidth Granularity (L1Mbps) Enter minimum value: 1 for 100Mbps Ethernet 10 for Gigabit Ethernet 100 for 10GigE Test Ctls: Test Durations Configure test durations separately? Duration Number of Trials 1 No 120 seconds This will result in approximately 6 minutes of test time per frame length. Show Pass/Fail Select all ( ) Throughput Threshold See Work Order Enter CIR Throughput Frame Loss Tolerance (%) See Work Order Enter 0.000 if not specified Test Ctls: Test Thresholds Latency RTD (µs) Packet Jitter (µs) See Work Order See Work Order Enter threshold in µsecs (1 msec = 1000 µsec). Uncheck the Show Pass/Fail box if a threshold is not specified. Acterna Payload Version Version 2 11

RFC 2544 Test Procedure Save Profile In the Save Profiles screen, enter a Filename, and tap. Tap, tap, and tap twice. 12

RFC 2544 Test Procedure Running the Test Ensure that the loopback device has been setup, and tap to run J- QuickCheck to verify local connectivity, loop up the remote loopback device, and check available bandwidth. 13

RFC 2544 Test Procedure Running the Test Tap, and tap. The T-BERD will loop up the loopback device and run all configured tests. Detailed results for each test can be viewed by tapping. 14

RFC 2544 Test Procedure Create a Report Tap twice and enter Customer name, Technician ID, Test Location, Work Order Number and Comments/Notes. Tap again and tap View the Report and tap 15

Y.1564

Y.1564 Test Procedure Select Test In the Select Test menu,,at the top left corner of the screen, choose one of the following: For 10BASE-T, 100BASE-T, or 1000BASE-T Electrical Ethernet testing: Ethernet 10/100/1000 Y1564 SAMComplete L2 Traffic P1 Terminate. For 100BASE-FX Optical Fast Ethernet testing: Ethernet 100M Optical Y1564 SAMComplete L2 Traffic P1 Terminate. For 1000BASE-SR, 1000BASE-LR, or other GigE Optical Testing: Ethernet 1GigE Optical Y1564 SAMComplete L2 Traffic P1 Terminate. For 10GBASE-SR, 10GBASE-LR, other 10GigE Optical Testing: Ethernet 10GigE LAN Y1564 SAMComplete L2 Traffic P1 Terminate. 17

Y.1564 Test Procedure - Configure If this is the first time using the Y.1564 test and your unit does not have pre-loaded configuration files, tap the button next to Start a New Configuration (reset to defaults) and proceed to step 2. Otherwise, tap the button next to Load Configuration from a Profile Select the desired configuration, and tap. Tap to acknowledge successful load, tap the button, and tap the button next to Edit Configuration. 18

Y.1564 Test Procedure - Setup Use the and buttons at the bottom of the screen to advance through the wizard and configure Layer 2 Network Setting as follows: Screen Option Value(s) Comment Connect: Symmetry Connect: Configuration Templates Throughput Measurements Do you want to use a configuration template? Symmetric Loopback No Connect: Local Settings Frame Type DIX Number of Services See Work Order Enter 1 if not specified. Network Services Test Mode Traffic or LBM Traffic Select LBM Traffic if the loopback device is an ALU 7705. Select Traffic for all other loopback devices. 19

Y.1564 Test Procedure - Setup Network: Services, LBM Settings (Advanced) Maint. Domain Level Enable Sender TLV See Work Order No (unchecked) Tap the LBM settings link to configure these settings. Network: Services, Network Settings (Advanced) Frame Size Dest. MAC Address See Work Order; Enter EMIX if not specified See Work Order Tap the DA MAC and Frame Size settings link to configure these settings. Do Services have different VLAN ID s or User Priorities? See Work Order Select No if not specified Network: Tagging Encapsulation See Work Order None or VLAN. Select None if not specified VLAN ID See Work Order User Priority See Work Order Enable Aggregate Mode No (unchecked) SLA: SLA Throughput CIR See Work Order EIR See Work Order Enter 0 if not specified Policing Select if CIR < line rate. Deselect if CIR = line rate 20

Y.1564 Test Procedure - Setup SLA: SLA Burst Would you like to perform burst testing? Burst Test Type See Work Order Committed Burst Size Select No if not specified CBS See Work Order Frame Loss Ratio See Work Order Enter 0.000000 if not specified. Frame Delay (RTD, ms) See Work Order If not specified: 50 for Circuit Emulation 20 for EPL/EVPL 10 for Mobile Backhaul SLA: SLA Performance Delay Variation (ms) See Work Order If not specified: 20 for Circuit Emulation 20 for EPL/EVPL 2 for Mobile Backhaul Acterna Payload Version Select Version 3 if loopback device is another T-BERD. Otherwise, select Version 2 Test Controls Number of Steps Below CIR 3 Step Duration (Sec) 15 Test Duration 5 21

Y.1564 Test Procedure Save Profile In the Save Profiles screen, enter a Filename, and tap. Tap, tap, and tap twice. 22

Y.1564 Test Procedure Running the Test In the Select Y.1564 Tests screen, select all Services, Service Configuration Test, Service Performance Test, and Throughput (RFC-2544). Enter the total (Sum) CIR for all combined services in the Max. (L1 Mbps) field, then press 23

Y.1564 Test Procedure Running the Test Ensure that the loopback device has been setup, and tap to run J-QuickCheck to verify local connectivity, loop up the remote loopback device, and check available bandwidth. 24

Y.1564 Test Procedure Running the Test Tap, and tap. The T-BERD will run all configured tests. Detailed results for each test can be viewed by tapping. 25

Y.1564 Test Procedure Create a Report Tap twice and enter Customer name, Technician ID, Test Location, Work Order Number and Comments/Notes. Tap again and tap View the Report and tap 26

Software Update

Software update Power On - Press and hold the ON/OFF button to turn on the T- BERD 5800v2. AC Power - Connect the AC power adapter to the power connector on the side of the T-BERD 5800v2. LAN Connection - Connect the Ethernet Management Port on the side of T-BERD 5800v2 to a network connection with internet access, using CAT 5E or better cable. 28

Software update Network Upgrade Press the System icon,, at the top of the start-up screen, to display the System Menu. 29

Software update Network Upgrade Press the Network icon,, to display LAN Settings. Set IP Mode to DHCP for automatic IP address assignment or Static for manual input. After configuring LAN settings, press the System icon,, to redisplay the System Menu. 30

Software update Network Upgrade Press the Upgrade icon,, to display upgrade methods. 31

Software update Network Upgrade Press to display upgrade settings. Ensure that Server Address = 5800v2.updatemyunit.net 32

Software update Network Upgrade Press to show the upgrade versions available at upgrademyunit.net. Press, and press to initiate the upgrade. 33

Software update USB Upgrade Using an internet browser on your PC or laptop, go to http://updatemyunit.net/ 34

Software update USB Upgrade Click on to display the T-BERD 5800v2 upgrade portal. Download the file by clicking one of the flags and save extract the files in a USB 35

Software update USB Upgrade Press the Upgrade icon,, to display upgrade methods. 36

Software update Network Upgrade Press to show the upgrade versions available at upgrademyunit.net. Press, and press to initiate the upgrade. 37