iconverter 2-Module Power Chassis

Similar documents
Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

iconverter 1-Module Redundant Chassis

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

General and Copyright Notice Warranty OmniConverter Limitation of Warranty Environmental Notices User Manual

OmniConverter GPoE+/M Managed 4 and 8-Port PoE/PoE+ Switch. Quick Start Guide

Automated Tuner System Power Distribution Hub

OmniRepeater TM 400FTD. Systems AS400/3X Fiber to Desk Repeater. User s Manual SPECIFICATIONS TECHNICAL SUPPORT

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

87421/22A Power Supply. Operating and Service Manual

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

User s Guide. POWERVAR Single Phase Power Conditioners

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

OmniConverterTM. OmniConverter FPoE/SL, FPoE/S and FPoE+/S 10/100 Media Converter with Power over Ethernet (PoE or PoE+) KEY FEATURES

PSA200 User s Manual

TRC-190 User s Manual

Installation Job Aid for Ethernet Routing Switch 3600 Series

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installing the Cisco MDS 9020 Fabric Switch

Broadband Automatic Disconnect Switch. User Manual

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Innovative Circuit Technology Ltd.

Power Supply (48Vdc, 2.5A)

MPP1700 User s Manual

C Mb Ethernet Copper Tap

Vocia ELD-1. Operation Manual

Perle MCR200 Installation Guide

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

CMSA-100 Manual. Cinema Media Server Automation

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

PV Rapid Shutdown device

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

Power Rack 58. EXT-PS5-8R User Manual.

Installation Job Aid for VSP 4450GTX-HT- PWR+

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

300 - SERIES NETWORK SWITCHES QUICK START GUIDE

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

INSTALLATION GUIDE ER8400U. 8 Port Wall Mounted IP Video Extender Over UTP With Built-In Gigabit PoE+ Switch and EtherStretch.

Dell Networking S4810 Open Networking (ON) Getting Started Guide

NT1B-300 Rack Installation Instructions

Junos WebApp Secure 5.0 Hardware Guide

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

LVN5200A-R2, rev. 1, Hardware Installation Guide

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Zonit μats TM Users Guide μats1-lv Version 1.2

Media Conversion Rack-Mount Chassis AT-MCR12. Installation Guide Rev. A

INSTALLATION GUIDE ER8400C. 8 Port Wall Mounted IP Video Extender Over Coax With Built-In Gigabit PoE+ Switch and EtherStretch.

4170 POS System Installation Guide

16-SLOT IN-BAND MANAGEMENT CHASSIS

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

Line Impedance Stabilization Network (LISN)

UTAH-100/XHDA SERIES

Installation Guide. Rev

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Installation Job Aid for VSP 4850GTS

Active UTP Transceiver Hub with Integral Isolated Camera Power

SATA II HDD Canister KISS DA 435 Quick Reference Guide

3190 Series Touch Screen POS Workstation

User's Guide. Extech AM A AC Analog Clamp Meter

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

AC4G-D User s Manual

User s Guide. 600A AC Clamp Meter. Model 38387

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

AEXX-349 SERIES REMOTE DISPLAYS

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Quick Start/Installation Guide

Dell SC7020 Storage Controller Getting Started Guide

1-36V, 0-3A DC Power Supply

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

S82S (3/7.5-W Models)

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

E-Tool Mobile Manager 6 Drawer Rugged Managed (Rev. 0)

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Online Connection Kit. Installation Manual

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

OPERATIONS MANUAL PCM-I/O48

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

VIP-812A DUAL NETWORKED STATION PORT

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

Installing the Cisco AS5400XM Universal Gateway

PD-6506, PD & PD-6524

X-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

MPP200 User s Manual

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Transcription:

iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1

Warning The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this module other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems Technology, Inc. Caution All user-required operations can be performed without opening the chassis. Never attempt to open or remove the cover or tamper with the chassis. There are no user replaceable or serviceable parts in this unit. Equipment is not intended to be installed and used in a place (home, school, or public area) accessible to the general population. Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM. Or you may register your product on the Internet at http://www. omnitron-systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective. For warranty service, the product must be sent to an Omnitron designated facility, at Buyer s expense. Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method. Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance. No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose. Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory. Page 2

1. 0 GENERAL DESCRIPTION iconverter 2-Module Power Chassis User Manual The iconverter 2-Module Power Chassis is powered by a single internal universal AC or power supply and can accommodate up to two iconverter media converters. It is ideal for enterprise Local Area Network (LAN) or Metropolitan Area Network (MAN) applications where remote management and explicit demarcation between the service provider s equipment and customer s equipment is required. This User Manual describes the following models: Fig. 1 2-Module Chassis (Shown without modules installed) 2-Module Chassis Description AC 8.5 watts AC AC High Airflow 8.5 watts High Airflow 2-Module Chassis 8230-0 8231-0 - 8235-0 8236-0 - 2-Module Chassis with Dying Gasp Support 8230-1 8231-1 8232-1 8235-1 8236-1 8238-1 Wall-Mount Hardware Kit 8249-0 19 Rack-Mount Shelf 8260-0 Blank Module Panel 8090-0 For wide temperature (-40 to 60 C), add a "W" to the end of the model number. Contact Omnitron for extended temperature (-40 to +75 C) models. 1.1 Dying Gasp Trap The 8230-1, 8231-1, 8232-1, 8235-1, 8236-1 and 8238-1 chassis feature Dying Gasp Trap, which reports loss of power input or chassis power supply failure. This feature requires an iconverter management module be installed in the chassis. When power failure occurs, the chassis reserves enough power to keep the installed modules running in order to send a final SNMP alert to the management software. 1.2 Terms Backplane Module A printed circuit board which is permanently mounted inside the chassis and is populated with receptacle connectors into which modules are inserted. An iconverter plug-in card positioned into a slot location and inserted into a backplane connector. Module-Guide A mechanical channel guiding module insertion into a backplane connector. Slot A Link A Port A single chassis position consisting of a backplane connector and its associated module-guides. A backplane slot-to-slot connection that provides Ethernet connectivity between adjacent slots. An interface on a module capable of Ethernet traffic via the backplane s A Link. Page 3

Notes: 1. Other iconverter multi-module chassis models also support a backplane B Link. This feature is not required on the 2-Module Chassis. 2. Other modules support a B Port. In the application drawings in this manual, the B Ports depicted are not connected. 1.3 Mechanical Description The 2-Module chassis consists of a fixed internal AC (models 8230-0, 8230-1, 8231-0, 8231-1 and 8232-1) or (models 8235-0, 8235-1, 8236-0, 8236-1 and 8238-1) power supply that provides power to the chassis two (2) backplane connectors. 1.4 Backplane Architecture The chassis features two (2) module slots numbered 1 (top slot) and 2 (bottom slot). As modules are inserted into the chassis slots, they are seated into the slot connectors. The two slots are connected using the A Link which provides Ethernet connectivity between the two slots. When modules with A Port capability are inserted into the adjacent chassis slots, they can connect their Ethernet data using their A Ports and the A Link. Note: Not all modules support and have backplane ports. To find out about each specific module s backplane port configuration, refer to the specific module s documentation. This chassis architecture facilitates a variety of applications including unmanaged, out-of-band managed, in-band managed and multi-port configurations. Fig 2. Depicts the chassis backplane architecture. A Backplane Link Slot 1 Connector Slot 2 Connector Fig. 2 2-Module Backplane Architecture 1.5 Application Examples 1.5.1 In-Band Managed 10/100 Converter Application Fig 3. Depicts a typical in-band managed fiber to UTP conversion at a Customer s Premises (CP) or at a remote network edge. In-band management is a desirable feature in these applications since it facilitates remote monitoring, configuration and trap notification from the chassis. VLANs can be used to separate the customer data from the management data. This application uses an iconverter 10/100M2 module for media conversion and management and a 4TxVT 4-Port 10/100 switch module for added customer connectivity. Both modules are plugged into the 2-Module chassis. The 10/100M2 converter module features two front-plane Ethernet ports (100BASE-FX fiber and 10/100BASE-T RJ-45) and two 10/100Mbps Ethernet backplane ports (A and B Ports). The 4TxVT module features four front-plane Ethernet ports (10/100BASE-T) and two 10/100Mbps Ethernet backplane ports (A and B Ports). The user data flows between the fiber and RJ-45 ports of the 10/100M and 4TxVT via the backplane. The management data flows between the fiber and all the RJ-45 ports (in-band). Using a management VLAN, the management data is recognized by the 10/100M module and is not shared by the other ports. This configuration provides the network administrator with the ability to manage and maintain the converter chassis at the remote location. Page 4

A Link Chassis Backplane A Port B Port A Port B Port Note that the 2-Module Chassis does not include the B Backplane Link Internal 10/100 switch chip Internal 10/100 switch chip Fiber 100 port UTP 10/100 port 10/100M Module 4-port 10/100 UTP Switch 4TxVT Module Fig. 3 In-Band Managed 10/100 Converter Application 1.5.2 Out-of-Band Managed 4-Port Switch Application Fig 4. Depicts a typical managed switch application. This application uses a 4TxVT 4-Port 10/100 switch module and an iconverter Network Management Module (NMM2) for management. Both modules are plugged into the 2-Module chassis. The 4TxVT features four front-plane 10/100BASE-T RJ-45 Ethernet ports and two 10/100Mbps Ethernet backplane ports (A and B Ports). The NMM2 features a 10/100BASE-T front-plane port and a 10/100Mbps Ethernet backplane A Port. Out-of-band management is provided by connecting to the front-plane port on the NMM module. The management data is separate from the user data on the 4TxVT. This configuration provides the network administrator with the ability to efficiently and cost effectively manage a small (4-port) workgroup switch. A Link Chassis Backplane A Port A Port B Port Note that the 2-Module Chassis does not include the B Backplane Link NMM Internal 10/100 switch chip NMM UTP 10 port NMM Module 4-port 10/100 UTP Switch 4TxVT Module Fig. 4 Managed 4-Port Switch Application 2.0 UNPACKING, VISUAL INSPECTION AND INVENTORY Review contents. The following items should be included: iconverter 2-Module Power Chassis One AC power cord (AC MODULES ONLY) One power connector ( MODULES ONLY) User Manual Inspect equipment and immediately report any damage or discrepancies to Omnitron at 949-250-6510. If equipment is damaged, do not apply power to the equipment. Page 5

3.0 SITE PREPARATION AND INSTALLATION 3.1 AC Powered Chassis Site Preparation Power source should be available within 5 ft. of the chassis and installed per the National Electrical Code ANSI/ NFPA-70. This equipment requires a 100-240VAC, 0.5Amp, 50/60Hz power outlet. Appropriate overloading protection should be provided on the AC power source outlets utilized. The standard operating temperature of this equipment is 0 to 50 degrees C. If installed in a closed or multi-module rack assembly, the operating ambient temperature of the rack must not exceed the maximum rated 50 degrees C. See specifications on page 10 for wide temperature ranges. Installation of the equipment should be such that the air flow in the front, back and side vents of the chassis are not compromised or restricted. Never use this equipment to carry any weight except its own. Never use it as a shelf to support the weight of other equipment. 3.2 AC Powered Chassis Mounting Attach the AC power cords to the back of the Power Receptacle and plug into the AC outlet. Any installed iconverter modules will illuminate the power LED. 3.3 Powered Chassis Site Preparation Fig. 6 Rear of 2-Module Chassis with Power Cord Power source should be available within 5 ft. of the chassis. The over current protection for connection with centralized shall be provided in the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and installed per the National Electrical Code, ANSI/NFPA-70. This equipment requires 18-60V/1.0Amp (8235) or 2.0Amp (8236 and 8238) rated power. Appropriate overloading protection should be provided on the power source outlets utilized. WARNING: Only a power source that complies with safety extra low voltage (SELV) requirements can be connected to the -input power supply. WARNING REGARDING EARTHING GROUND: o This equipment shall be connected to the supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the supply system earthing electrode is connected. o This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same supply circuit and the earthing conductor, and also the point of earthing of the system. The system shall not be earthed elsewhere. o The supply source is to be located within the same premises as this equipment. o There shall be no switching or disconnecting devices in the earthed circuit conductor between the source and the earthing electrode conductor. Page 6

The standard operating temperature of this equipment is 0 to 50 degrees C. If installed in a closed or multi-module rack assembly, the operating ambient temperature of the rack must not exceed the maximum rated 50 degrees C. See specifications on page 10 for wide temperature ranges. Installation of the equipment should be such that the air flow in the front, back and side vents of the chassis are not compromised or restricted. Never use this equipment to carry any weight except its own. Never use it as a shelf to support weight of other equipment. 3.4 Powered Chassis Mounting Locate the circuit breaker of the external power source, and switch the circuit breaker to the OFF position. Prepare a power cable using a three conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the iconverter Chassis by fastening the stripped ends to the power connector. WARNING: Note the wire colors used in making the positive, negative and ground connections. Use the same color assignment for the connection at the circuit breaker. Connect the power wires to the circuit breaker and switch the circuit breaker ON. If any modules are installed, their Power LED should indicate the presence of power. Fig. 7 Rear of 2-Module Chassis with Power Connector WARNING!!! NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY OR FAN MODULE. OPENING THE CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH. THERE ARE NO USER REPLACEABLE OR SERVICEABLE PARTS IN THIS UNIT. Page 7

4.0 SPECIFICATIONS Description AC AC AC* High Airflow * High Airflow Model Number Standard: Dying Gasp: Module Capacity Power Supply Capacity Regulatory Compliances Input Power Requirements (typical) Output Power Power Connector Dimensions Weight Temperature Humidity 8230-0 8230-1 100 to 240VAC, 50/60Hz 8231-0 8231-1 100 to 240VAC, 50/60Hz 0.5A @ 120VAC 0.5A @ 120VAC 8.5 watts 2.6A @ 3.3V 1.5A per slot 5A @ 3.3V 2.5A per slot - 8232-1 2 8235-0 8235-1 Single Fixed Internal Power Supply UL, CE, FCC Class A, NEBS Level 3, RohS2, WEEE 100 to 240VAC, 50/60Hz 0.5A @ 120VAC 5A @ 3.3V 2.5A per slot IEC 320 Socket IEC 320 Socket IEC 320 Socket 18 to 60V -48V @ 1.0A 6.6 watts 2A @ 3.3V 1.5A per slot 3-Pin Terminal (Isolated) W: 6.7" x D: 5.51" x H: 1.87" L: 435.6 mm x B: 228.6 mm x H: 44.5 mm 2.5 lb (1.14 kg) Commercial: Wide: Storage: 0 to 50 C -40 to 60 C -40 to 80 C 5 to 95% (non-condensing) Altitude - 100m to 4,000m 8236-0 8236-1 18 to 60V -48V @ 2.0A 5A @ 3.3V 2.5A per slot 3-Pin Terminal (Isolated) - 8238-1 18 to 60V -48V @ 2.0A 5A @ 3.3V 2.5A per slot 3-Pin Terminal (Isolated) MTBF (hrs) 151,000 413,000 50,000 329,000 538,000 50,000 Warranty Lifetime warranty with 24/7/365 free Technical Support The 8231-x and 8236-x have internal temperature-controlled fans. The fan will turn on when the chassis internal temperature is greater then ~40 o C. Under normal operating temperature, the fan is off. The 8232-1 and 8238-1 have internal fans that are always turned on. Page 8

5.0 CUSTOMER SUPPORT INFORMATION If you encounter problems while installing this product, contact Omnitron Technical Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc. 38 Tesla Irvine, CA 92618, USA Email: support@omnitron-systems.com URL: www.omnitron-systems.com 040-08230-001L 7/14 Page 9