Routing Power and Signal Cables

Similar documents
Routing Power and Signal Cables

Assembling the Remaining Cisco TelePresence Elements

Field-Replaceable Unit Guide

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Field-Replaceable Units and Region- and Country-Specific Power Cables

First-Time Setup. Summary Steps CHAPTER

Replacing Preamplifier Circuit Boards

Assembly Instructions

Service Parts Diagrams

Service Parts Diagrams. For Model: 2000i-DVS with the NEC VT465 Projector 2000i-DVS with the NEC VT470 Projector

Installing the Cisco MDS 9020 Fabric Switch

Implementing Cisco TelePresence Installations (ITI)

EN TECHNICAL MANUAL. Ikall and Ikall Metal modular entrance panel. Passion.Technology.Design.

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Integration and Cabling Guide HAWM-UX/UF Height Adjustable Wall Mount

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

PARTNER Contact Closure Adjunct

If technical support is required, please contact Advent Technical Support at

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Installing the PictureTel 900 Series Collaboration System. Ready... Set... Go...

Installation guide. for Cisco TelePresence MX700 Dual Camera mounted on the wall

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Installation Job Aid for Ethernet Routing Switch 3600 Series

Service Parts Diagrams. For Model: 2000i-DVX with the the NEC VT595 MT1060 Projector

Plasma Panel Replacement Guide DU-42PX12X

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Installation Job Aid for Ethernet Routing Switch 5900 Series

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

The port replicator may have features that are not supported by your computer.

Lifesize Icon Installation Guide October 2016

Dell XPS 14z Owner s Manual

XT-3815/3915IR Fanfree LCD Touch Terminal Quick Installation Guide

Kit Instructions. Camera (NTSC) and Telephone Handset Upgrade K034 Issue A

Assembly and Setup Manual

UniStream HMI Panel. CPU-for-Panel

rooms Conference Room Mac Quickstart Guide

Quick Installation Guide

Installing Power Modules

Assembly and Setup Manual

E1135C PDU and Pod Upgrade Procedure

FreeNAS Mini and Mini XL Network Upgrade Kit

EH50 ATTENTION: SECURITY COVERS ARE NO LONGER INCLUDED IN THE HEADREST KITS AS OF

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Written By: Walter Galan

Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1

USB 2.0 CAT5E/6/7 EXTENDER

Installing a Power over Ethernet injector

Implementing Cisco TelePresence Solutions (ITS)

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Gateway Profile 4 service guide

V.I.A. - Monitor Shroud

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

Installation Instructions

Contents. Vector Scorers 1

REMOTE HEAD ADAPTER INSTALLATION GUIDE

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

X-Port 20 Switch (XP i-B) Installation Guide for any. 2000i. Equipped. with an. NEC VT465 or VT560 Projector

Dell Inspiron N5110 Service Manual

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

M204SMB Surface Mount Box Instructions

PIX 535. PIX 535 Product Overview CHAPTER

ww.battery-adapter.com

Installing and Managing the Switch

Installation guide. for Cisco TelePresence MX700 Dual Camera on a free standing floor stand or a floor stand secured to the wall

Part Number: Lt. Taupe / Stone / Ivory Touring Edition Accessory Code: EH3

CTS System Status for External Projector/LCD Shows Red X

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

First-Time Setup. Setting Up Your System for the First Time CHAPTER

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

Installation guide. for Cisco TelePresence MX700 Single Camera on a free standing floor stand or a floor stand secured to the wall

HD Flex Zero RU Cassette Holder and Bracket

GT Mini Installation Guide. 30 March 2015

X-Port 20 Switch (XP i-C) Installation Guide for any. 2000i. Equipped. with an. NEC VT470 or VT570 Projector

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Installation Instructions

Cisco Implementing Cisco TelePresence Installations(ITI) Download Full Version :

HAIKU WALL CONTROL KIT

Cable Routing Procedures for Dell PowerEdge R630 Systems

Installation Instruction VCPRGBGM05 - rev1.5 RGB Interface Harness modification Navigation Radio

COLLABORATE Room Pro with Beamforming Microphone Array Professional Conferencing Quick-Start Guide

Havis Integrated Control System Installation Instructions for Standard* Ford Police Interceptor Utility

Power Xpert Meter 2000 Gateway Card Kit

Service Parts Diagrams. For Model: FSSBID 100H FSSBID LTS FSSBID RACK MT ADP USB AB

Installing System Board Options

Manual Version: V1.00. Video Decoder Quick Guide

Installing and Removing SDRAM and DRAM

TOYOTA SIENNA Dual Headrest Video

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Spare parts. for Cisco TelePresence MX800

apple Service Source imac (USB 2.0) Updated 11 September Apple Computer, Inc. All rights reserved.

FCC Regulatory Information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

HSC-42. HDMI 4k2k Video Up/Down Scaler

IPC P HD Door Station IP Camera. Quick Installation Guide

Installation Instructions

V910 Kit. Hardware Installation Guide. P/N Revision: A

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Transcription:

10 CHAPTER Revised: May 15, 2013, Parts List Key Part Description Part Number Qty Ctn s 1 Power distribution units 74-4787-01 4 1 2 Speaker cable 37-1062-01 3 1 3 8 m DVI-to-VGA + audio cable 37-0848-01 1 1 4 6 m video cable 37-0854-01 1 1 5 3 m (black) Cat6 Ethernet cable 37-0877-01 5 1 6 10 m Cat6 Ethernet cable, blue 37-0901-01 2 1 7 7 m power cord 37-xxxx-xx 1 10 See Appendix B, Region- and Country-Specific Equipment, for specific part numbers. 8 3 m Jumper cord 37-0833-01 9 1 9 2 m Jumper cord 37-0852-01 1 1 Used for presentation display. 10 3 m Video-to-DVI cable 37-0853-01 3 1 11 Cable identification stickers 51-4582-01 3 1 12 Cable ties 51-4536-01 75 1 13 Cable tie holders 51-0609-01 75 1 14 Ferrite Core 36-0244-01 12 1 15 Rear cable tray cover 700-30921 Kit #69-2067 Subkit # 69-2043 2 16 M8 x 20 mm screws 48-2273-xx 1 Presentation Display-to-Auxiliary Control Unit (DSUB to 8-P MINI DIN) cable 37-0980-01 1 19 Packaged with Auxiliary Control unit 10-1

Parts List Key Part Description Part Number Qty Ctn s Microphone extension cords Label sheet for power and signal cables Included with 74-4743-xx 47-22788-01 Kit #69-2063-01 3 1 Included in Microphone kit 2 1 Sub-carton 2 Caution Do not power on the PDUs and auxiliary control unit until you connect and route all the cables. Caution Use care when you route the power cables from the PDUs. Do not bend the cables immediately after they exit the PDUs and be sure that the cable does not pull on, or cause any strain to, the PDU. Incorrectly routed cables can cause undue stress to the PDU receptacle and the power cord plug. Warning Overcurrent protection is provided by branch circuit protection rated 20A @ 100-120 volts. Warning Output receptacles cannot exceed 15A @ 100-120 volts for any one receptacle. 10-2

General PDU Connection and Cable Routing Guidelines General PDU Connection and Cable Routing Guidelines Caution Make sure that the power cord plugs are fully plugged into the PDUs, and that that jumper cords are fully plugged into the PDU and wall outlet. Improper connections between the PDUs and the power cord plugs can cause the PDU to overheat and fail. Caution Use care when you route the power cables from the PDUs. Do not bend the cables immediately after they exit the PDUs and be sure that the cable does not pull on, or cause any strain to, the PDU socket and power cord plug connection. Incorrectly routed cables can cause undue stress to the PDU receptacle and the power cord plug. Use the following guidelines and tips to route the cables cleanly: There is an open slot between the top of the display shelf support arms and the underside of the table. You can use this slot to route the cables to the side PDUs that are located on the screen end caps. The cable tray has three shelves. To minimize electromagnetic interference, route the cables as follows: Use one row for power cables Use one row for signal (for example, Ethernet) cables Use one row for video cables The Cisco TelePresence system includes cable ties and cable tie holders that assist in cable routing. Peel off the adhesive of the holder, bundle the cables that you want to bundle or route, and tie them to the cable tie holder with the cable ties. You can install the cable tie vertically as shown in Figure 10-1, or horizontally. Use the method that works the best for your cables. For cable routing for the second row table, see Chapter 7, Building the Second Row Table Assembly. 10-3

Special ESD Procedures for the Codec and Audio/Video Extension Unit Cables Figure 10-1 Cable Routing Guidelines Signal and Camera Power Ethernet 207526 Special ESD Procedures for the Codec and Audio/Video Extension Unit Cables Be sure that you perform electrostatic discharge (ESD) procedures before you connect cables to the codec and audio/video extension unit, particularly the HD Video and microphone cables. Caution Failure to perform ESD procedures can cause damage to the boards inside the codec or audio/video extension unit and render your system inoperable. To discharge the cables of any static electricity before connecting them, complete the following steps: Step 1 Step 2 Step 3 Discharge each cable by touching the metal cable connector to the codec or audio/video extension unit cable connector. Figure 10-11 provides an example of the correct way perform ESD procedures on the microphone cable; you can perform the same procedure for the HD video and other cables. Hold the cable connector to the codec or audio/video extension unit cable connector for 3 seconds. Immediately connect the microphone to the codec or audio/video extension unit. 10-4

To route the power and signal cables for your Cisco TelePresence system, complete the following steps. Step 1 Route the second row microphone extension cables to the rear of the CTS 3210. If required, use the microphone extension cables that are included in the microphone kit to lengthen the cables. Using masking tape or another method, note the cables as they correspond to the microphones. You use this information when you connect the microphone cables to the audio/video extension unit in Step 10. Figure 10-2 Microphone Cable Routing 204156 10-5

Step 2 If your installation provides Ethernet connectivity for second row meeting participants, attach the Ethernet cables to the modules in the foam bumpers and route the Ethernet cables. Figure 10-3 Ethernet Cable Routing 204157 10-6

Step 3 If your installation provides power to second row meeting participants, route the power cables for the second row table. The power cables connect to the floor-mounted electrical termination unit (for example, a junction box with two electrical outlets) that you install in the cable trench or other solution that you provide for the second row Ethernet, power, and microphone cables. Be sure to follow all electrical codes when providing this cabling solution. For more information, see the Power Requirements section on page 2-10, and for cable trenching diagrams with measurements, see Figure 2-8 and Figure 2-9. Figure 10-4 Second Row Table Power Cable Routing 204172 Floor-mounted junction box 10-7

Step 4 Connect the following cables: Attach and route the power cables for the lighting assembly by connecting the lights to the auxiliary control unit. Connect the DSUB to 8-P MINI DIN cable between the presentation display and the auxiliary control unit. Connect the Ethernet cables between the codec and the auxiliary control unit. Connect the power cord for the auxiliary control unit to a wall outlet. 10-8

TelePresence 1 2 4 5 7 8 ABC GHI JKL PQRS TUV 0 OPER 3 DEF 6 MNO 9 WXYZ # CISCO IP PHONE 7970 SERIAL PORTS RESET 10/100 NETWORK PORTS Figure 10-5 Cabling the Lighting Power Cables and Auxiliary Control Unit-to-Presentation Display Serial Cable 1 2 1 2 Power Projector RJ45 Ethernet 207078 Step 5 Attach and route the power and signal cables for the plasma displays. Connect the center plasma display to UNSWITCHED outlet of the the auxiliary control unit. 10-9

Figure 10-6 Cabling the Plasma displays Signal Power 204164 Figure 10-6 displays the rear view of the Cisco TelePresence System 3210. Left and right are reversed. Tip Step 6 Before you plug cables into a Codec or PDU, label each cable. Connect the camera assembly cables. Tip Connect the ferrite cores to the signal and power cables for the camera by completing Step 7. 10-10

Figure 10-7 Cabling the Camera assembly 5 10 RJ45 Power over Ethernet HDMI connector 207080 The camera cluster can experience radio frequency interference issues if the camera Ethernet and video cables are routed, bundled, or tied together. Cisco recommends that you route the Ethernet and video cables separately and use cable ties to tie them to opposite sides of the frame. Figure 10-7 displays the rear view of the Cisco TelePresence System 3210. Left and right are reversed. 10-11

Tip Step 7 Before you plug cables into a Codec, label each cable. Attach the ferrite cores to the ends of all six camera cables (both the video and Ethernet cables, 12 ferrite cores total). Wrap the cables around the ferrite as shown in Figure 10-8. Attach the ferrite cores so that they are approximately 1 1/2 inches (4 cm) from the connectors. Figure 10-8 Connecting the Ferrite Cores 14 14 206364 Step 8 Connect the signal cables between the primary and secondary codecs. If you ordered a Presentation Codec or Auxiliary Control Unit with your TelePresence system, see Figure 10-16 for additional cabling information. 10-12

Figure 10-9 Connecting the Codec Signal Cables Center Left Right Auxilliary 5 5 Left Codec Right Codec Audio Expansion Unit First Row Center Microphone Speaker 6 Camera 6 IP Phone Network Auxiliery Video In Display Auxiliery Video Out Document Camera 207082 Figure 10-9 displays the rear view of the Cisco TelePresence System 3210. Left and right are reversed. 10-13

Step 9 Connect the codec power cables. Figure 10-10 Routing the Codec Power Cables Power 207081 10-14

Step 10 Connect the microphones to the microphone cables; then, connect the microphone cables to the codec and audio/video extension unit as shown in Figure 10-12. If you have a Reduced Configuration for your second row table (four tabletops instead of six), use the same connections, but omit the connections (white connection 2 and red connection 3) for the two outer table tops. Caution Perform the following steps to prevent damage from electrostatic discharge (ESD) to the microphone, audio/video extension unit, or codec: a. Discharge each microphone cable by touching the metal cable-connector to the codec or audio/video extension unit cable as shown in Figure 10-11. b. Hold the cable connector to the codec or audio/video extension unit cable for 3 seconds. c. Immediately connect the microphone to the codec or audio/video extension unit using the diagram in Figure 10-11. Figure 10-11 Discharging ESD from the Microphone Cables and Connecting the Microphone Cables and Microphones 208391 208392 10-15

Figure 10-12 Cable Routing for Microphones 205760 Tip Step 11 Before plugging cables into the Codec, label each one. Connect the presentation display power cable to the near-left PDU. Figure 10-13 displays the rear view of the Cisco TelePresence System 3210. Left and right are reversed. 10-16

TelePresence 1 2 4 5 ABC GHI JKL 7 PQRS 8 TUV 0 OPER 3 DEF 6 MNO 9 WXYZ # CISCO IP PHONE 7970 Figure 10-13 Presentation Display Power Connection Power 208889 Step 12 Cover the cable routing trays with the tray covers. 10-17

Figure 10-14 Cable Routing Tray Covers 207083 10-18

Cable routing for a standard CTS-3210 installation that uses a presentation codec is shown in Figure 10-15. Cable routing for presentation display for a standard Cisco TelePresence system installation is shown in Figure 10-16. Refer to the Options for the Cisco TelePresence System 3000, 3010, 3200, and 3210 chapter of the Cisco TelePresence Hardware Options and Upgrade Guide for more information about the presentation codec. Be sure to connect the serial cable from the auxiliary control unit to the RS232C IN connection of the presentation display (the serial connection that is closest to the conference participants). 10-19

SERIAL PORTS RESET 10/100 NETWORK PORTS Figure 10-15 Cable Routing for Standard Cisco TelePresence system Presentation display Auxiliary Control Unit 1 2 1 2 Serial (RS232 IN) Video In Serial 2 Serial 1 Ethernet 1 Ethernet 2 Center Right Far Left Far Right Center Left Left Codec Right Codec Primary Codec Speaker Audio Expansion Unit First Row Center Microphone Camera Auxiliary network port Auxiliary Video In Display Auxiliary Video Out Document Camera 206986 IP Phone Network 10-20

Cable routing for a standard Cisco TelePresence system installation that uses a presentation codec is shown in Figure 10-16. Refer to the Options for the Cisco TelePresence System 3000, 3010, 3200, and 3210 chapter of the Cisco TelePresence Hardware Options and Upgrade Guide for more information about the presentation codec. Be sure to connect the serial cable from the auxiliary control unit to the RS232C IN connection of the presentation display (the serial connection that is closest to the conference participants). 10-21

SERIAL PORTS RESET 10/100 NETWORK PORTS Figure 10-16 Cable Routing for Cisco TelePresence system with Presentation Codec Presentation display Auxiliary Control Unit 1 2 1 2 Serial (RS232 IN) Video In Presentation Codec Serial 2 Serial 1 Ethernet 1 Ethernet 2 Center Right Signal Auxiliary Video In Video out Far Left Far Right Center Left Left Codec Right Codec Primary Codec Speaker Audio Expansion Unit First Row Center Microphone Camera Auxiliary network port Auxiliary Video In Display Auxiliary Video Out Document Camera 206987 IP Phone Network Step 13 (Optional) If your installation uses an optional external display or a document camera, install and route the cabling as shown in Figure 10-17. Because you need to split the video signal between the presentation display and any additional video output, you must purchase at least one extra cable to connect optional external display(s). Cables for the external displays and document camera are not included with the standard Cisco TelePresence installation. 10-22

When you use the audio/video extension unit as a video splitter, connect port 1 of the Video in connection from the codec, and port 4 of the Video out connection to the presentation display. Be sure to connect the serial cable from the auxiliary control unit to the RS232C IN connection of the presentation display (the serial connection that is closest to the conference participants). 10-23

SERIAL PORTS RESET 10/100 NETWORK PORTS Figure 10-17 Cabling Diagram: Cisco TelePresence system Installations with an External Display and Document Camera Auxiliary Control Unit 1 2 1 2 Presentation display Serial 2 Serial 1 Ethernet 1 Ethernet 2 External Display (Optional) Serial (RS232 IN) Video In Document Camera Video Out Document Camera Signal Document Camera (Optional) Audio/ Video Expansion Unit Video In Video Out Video In Center Right Far Left Far Right Center Left Left Codec Right Codec Primary Codec Speaker Audio Expansion Unit First Row Center Microphone Camera Auxiliary network port IP Phone Network Auxiliary Video In Display Auxiliary Video Out Document Camera Video In 206988 10-24

SERIAL PORTS RESET 10/100 NETWORK PORTS Figure 10-18 Cisco TelePresence System With an External Display, Document Camera, and Presentation Codec Auxiliary Control Unit 1 2 1 2 Projector Serial 2 Serial 1 Ethernet 1 Ethernet 2 External Display Serial Video In Presentation Codec Document Camera Video Out Document Camera Signal Document Camera Audio/ Video Expansion Unit Video In Video Out Video In Signal Document Camera Signal Auxiliary Video In Video Out Center Left Right Left Codec Right Codec Primary Codec Speaker Audio Expansion Unit First Row Center Microphone Camera Auxiliary network port IP Phone Network Auxiliary Video In Display Auxiliary Video Out Document Camera Video In 204194 Other Possible Configuration 10-25

For Figure 10-18, replace the projector in the diagram with the presentation display. 10-26