V-9964 Digital Feedback Eliminator/Message Stacker

Similar documents
V-9964 Digital Feedback Eliminator/Message Stacker

V-9964 Digital Feedback Eliminator/Message Stacker

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VIP-812A DUAL NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

V-9939B MICROPHONE ADAPTER

V-9908 MESSAGE/PAGE PANEL

VIP-480AL IP One-Way Horn

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

VIP-148AL IP Talkback Horn

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

VCMDM MODEM INSTALLATION INSTRUCTIONS

SIP PAGING SERVER MODEL VIP-201A

TALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

V-9939C MICROPHONE ADAPTER

V-9937 ONE ZONE PAGE PORT ADAPTER

Installation & User Manual

TALKBACK INTERCOM SYSTEM V-2928 OPTION BOARD

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

V-2001A SINGLE ZONE (PLUS) PAGE CONTROL UNIT

V-2001A SINGLE ZONE (PLUS) PAGE CONTROL UNIT

Messager USB w/ Night Answer

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series

Global Water Instrumentation, Inc.

DXRM57BT INSTALLATION/OWNER'S MANUAL. AM/FM Receiver with Bluetooth

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

Telephone Line Monitor USER GUIDE

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

NT1B-300 Rack Installation Instructions

MXD337BT INSTALLATION/OWNER'S MANUAL. AM/FM Marine Receiver with Bluetooth and Fixed Face

TELink FLASH. Model 700a. Installation and Operation Instructions. Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications

GEN10. HD/SD Sync Generator. User Manual

poly-planar Marine Audio System

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

Enterprise Call Manager

XRM47BT INSTALLATION/OWNER'S MANUAL. AM/FM Receiver with Bluetooth / Fixed Face

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

SERVICE MANUAL MODEL SSW-321-X

XC4100 INSTALLATION/OWNER'S MANUAL AM/FM/Cassette Receiver

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

SERVICE MANUAL. MODEL SSW-321-Fr1

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

EAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev.

PAGEPAC 6 V INSTALLATION There are several ways to connect PagePac 6 to your telephone system.

AMT-12 AMT-15. Professional Loudspeakers. Installation and Use Manual

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200XLN. XGA Line Amplifier / DA

Sonorous v2.0. Installation & User Manual

BACnet Router Start-up Guide

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

HD-1X4-4K User Manual

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

Kramer Electronics, Ltd. USER MANUAL

CA-A480-A Elevator Controller. Reference & Installation Manual

DS-8. CircuitWerkes. Technical Manual. Touchtone Sequence Decoder

GSMR20 OWNER S MANUAL

TALKBACK INTERCOM SYSTEM V-2928 OPTION BOARD

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

TABLE OF CONTENTS. Introduction Operation Notes Installation Front Panel Layout Front Panel Function Description...

Kramer Electronics, Ltd. USER MANUAL. Model: VM-50AN. 1:5 Audio Distributor

Broadband Automatic Disconnect Switch. User Manual

SERVICE MANUAL MODEL SSW-520-F

BluePack WIRELESS INTERVIEW TOOL

GSMR30 OWNER S MANUAL

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Kramer Electronics, Ltd. USER MANUAL. Model: VM-80HP. 1:8 Stereo Headphone Distributor

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

ASKING FOR ASSISTANCE

Kramer Electronics, Ltd.

AB-315. ibus Wall-Dock for A-Bus Audio Systems

BLUETOOTH SPEAKER. for ipod/iphone/ipad/android. User s Manual. Item #TA-11BTSP. PC Mac Ultrabook COMPATIBLE BLUETOOTH WIRELESS USB

BACnet Router Start-up Guide

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Owner s Instruction Manual

Kramer Electronics, Ltd. USER MANUAL. Model: VA-1DVIN. Virtual EDID

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

SA-59. GSM Communicator. Installation Manual

Page/Talk Industrial Desk Sets

CAT U S E R M A N U A L

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Kramer Electronics, Ltd.

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver

SINGLE READER EXPANSION MODULE

MP1020 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. 2 CH Media Player

Pairing your Bluetooth cellular phone with the MHF-R220BT. Installation guide. Voice : Power On. Pairing in HandsFree mode

DS-8a. CircuitWerkes. Technical Manual. Touchtone Sequence Decoder

AEXX-349 SERIES REMOTE DISPLAYS

WR-5e Remote Control

USER MANUAL. Kramer Electronics, Ltd. Models:

Transcription:

Issue V-99 Digital Feedback Eliminator/Message Stacker General Design The V-99 is designed to eliminate acoustic feedback and act as a message stacker. When a page is made, the message is digitized and saved. Upon completion of the live page, the message is released for broadcast over the speakers. While a message is being broadcast, additional messages may be recorded with a maximum of messages queued per V-99. Additionally, up to four V-99 units may be chained together to allow up to sixteen messages to be simultaneously processed. Specifications Features Automatic Gain Control (AGC) Adjustable VOX sensitivity Compatible with Valcom Multi-Zone Control Units and Station Adaptors Two input channels: Switch selectable primary and priority, or two channels with equal priority; both inputs are switch selectable for Loop Start or VOX operation Two audio outputs: 00 Ohms with loop supervision to a page control unit or 8 Ohms line level output to amplified speakers Background music input Total of three normally open relay contacts for PLAY, RECORD and BUSY mode (one contact each) LED status indicators for POWER, RECORD, PLAY and BUSY Dip switch option programming Message abort feature Access Vacant Loop Start Trunk Port or C. O. Line Port Page Port Line Level Audio Feed An adaptor is required for C. O. Line or station access (see V-990 or V-990) Dimensions/Weight." H x.0" W x." D (9.8cm H x 8.0cm W x.cmd). lbs. (.8Kg ) Nominal Specifications Power requirements: VDC 00mA filtered Input impedance: 00 Ohms Input level: -0dBm Loop Output impedance: 00 Ohms Line Output impedance: 8 Ohms Output level: -0dBm VOX sensitivity: seconds after last sensed audio Maximum recorded page time: 8 seconds (8 seconds per V-99 in call stacker Mode) Frequency response: Page: 80Hz to khz Background Music: 0Hz to khz Environment Temperature: Humidity: 0 to +0 C 0 to 80% non-precipitating 909

FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense. Installation/Connection Cabling Category or twisted pair cable is recommended for all Valcom distributed amplified paging installations. Screw terminals are provided for the basic connections. RJ jacks are provided for chaining multiple V-99 units together. Removing the narrow right side panel of the V-99 provides access to controls, connections and option switches. To remove the panel, loosen the two screws holding the panel in place and lift the panel. Mounting The V-99 may be wall mounted or rack mounted in a standard 9 inch equipment rack using the brackets included. Connections See Figure for a connection diagram. Tip, Ring INPUT is the normal Primary or Call Stacker system input, and connects to a Loop Start Trunk Port, 00 Ohm Page Port or some Valcom Page Controls. Note: Do not connect to a C. O. Line. Control Input Provides contact closure activation when using a Page Port. Tip, Ring INPUT is the Override page or Call Stacker line two input. If desired, connect this to a second Loop Start Trunk Port or Page Port. Note: Do not connect to a C. O. Line. Control Input Provides contact closure activation when using a Page Port. Background Music Input Connection for external line level music source (Example: V-9, FM Tuner). NOTE: If using multiple V-99 units in a chained configuration, all speakers must connect to the output of the last unit in the chain. Line Out Output connections to Valcom amplified speakers or 0 Volt amplifier Aux input. Loop Out Connects to Tip and Ring input on a Valcom multi-zone page control unit. Expansion In RJ connection from the previous V-99 in a chained configuration. Expansion Out RJ connection to the next V-99 in a chained configuration. Closing a switch connected to pin and pin of either Expansion In or Expansion Out will hold all queued recorded messages, on all linked V-99s. During this time, additional messages may still be recorded into the V-99(s). Once the switch is opened, all queued messages, including DTMF, will play in their entirety. Abort To abort a message during play, connect an external relay contact across the two abort terminals. NOTE: To abort a message during the record sequence, press any DTMF button on the dial pad of the access telephone. Relay Closure Outputs (PLAY) PLYSW and PLYMK Normally open relay contact that closes while a message is being broadcast. (RECORD) RECSW and RECMK Normally open relay contact that closes while a message is being recorded.

(BUSY) BSYSW and BSYMK Normally open relay contact that closes when the unit cannot accept any more messages. Switches and Controls NOTE: (-Left) (-Right) Refer to figure one for locations. SW-: Priority Port Options Leave in "" position when used as a Call Stacker (SW- is ""). Records Primary and Priority pages; Priority page broadcast first Priority page broadcast in real-time; Primary page in progress is recorded and broadcast after Priority page SW: Tip Ring No Battery Feed (Page Port) Battery Feed supplied (Loop Trunk Port) SW: Tip Ring No Battery Feed (Page Port) Battery Feed supplied (Loop Trunk Port) SW-: Message Playback Control Play message once Play message twice SW-, SW-: Pre-page Alert Tones No tones SW- SW- Single tone SW- SW- Dual tone SW- SW- Quad tone SW- SW- SW: VOX Sensitivity Sets audio detection threshold for input ports. SW- or SW- must be in the "" position for this adjustment to be effective. SW Level SW Level 0-0dBm 8-8dBm -dbm 9-9dBm -dbm A -0dBm -dbm B -dbm -dbm C -dbm -dbm D -dbm -dbm E -dbm -dbm F * -db *Typical Setting Program DIP Switch Settings NOTE: (-Left) (-Right) SW-: DTMF Signaling Options No DTMF signaling (single zone) DTMF signaling (multi-zone) SW-, SW-: Number of Digits to Receive Before Recording the Page. Digit SW- SW- Digits SW- SW- Digits SW- SW- Digits SW- SW- SW-8: Inter-page Timing Second between pages Seconds between pages SW-: Primary or Line Page Access Loop detect Audio detect SW-: Priority or Line Page Access Loop detect Audio detect SW-: Pre-Record Ready Tone Normal ( seconds delay) with ready to record tone No pre-record tone; allows immediate recording activation Note: This option is effective only when the inputs are set for LOOP start (SW- ). SW-: Normal or Call Stacker Mode Inputs-Primary and Priority Inputs will function as Call Stacker Note: Only one Priority port may be used on a Multi V-99 system. SW-8 Output Control Slave unit in a Chained system; Multiple V-99 Single unit or Master in a Chained system

Technical Assistance When trouble is reported, verify the unit is turned on and there are no broken connections leading to the unit. Assistance in troubleshooting is available from the factory. When calling from the job site, you should have a Volt/Ohm Meter and a telephone test set available for testing. Call (0) -000, press for Technical Support, or visit our Website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom maintains service facilities in Roanoke, VA. Should repairs be necessary, clearly tag the unit with your company name, address, telephone number, contact person and a description of the problem. Send the unit to: Valcom Inc. Repair and Return Department Hollins Road Roanoke, VA 09-0 VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that:. inspection by Valcom, Inc. indicates the validity of the claim;. the defect is not the result of damage, misuse or negligence after the original shipment;. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts and labor will be applied to units defaced or physically damaged);. freight charges for the return of products to Valcom are prepaid;. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to additional charges for parts and labor). This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation, maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the specific Product covered by the warranty. Disclaimer. Except for the Limited Warranty provided herein, the product is provided as-is without any warranty of any kind whatsoever including, without limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR N-INFRINGEMENT. This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point. Headquarters: Valcom, Inc. Hollins Road Roanoke, VA 09-0 Phone: (0) -000 FAX: (0) -9800

8 8 SW Switch Options Output Control MASTER UNIT CHAINED UNIT NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED System Mode CALL STACKER PRIMARY / PRIORITY Tones NO TES PRE-RECORD TE Priority Input AUDIO DETECT LOOP DETECT Primary Input AUDIO DETECT LOOP DETECT SW Inter Page Timing Alert Tones Alert Tones Message Play Input Play Options Record Digits See Chart Record Digits See Chart DTMF Options DTMF Record Seconds Second See Chart See Chart Play Twice Realtime Play Play Once CHART (Switches SW- & SW-) See Chart See Chart Record & Play See Chart See Chart NO DTMF Record Settings to select the number of DTMF Digits to Record One Digit SW- SW- Two Digits SW- SW- Three Digits SW- SW- Four Digits CHART (Switches SW- & SW-) Settings to select Pre Page Alert Tones Quad Tone SW- No Tone SW- SW- Single Tone SW- SW- Dual Tone SW- SW- SW- SW- SW- V-99 FIGURE : CNECTIS AND CTROLS (ACCESSIBLE WITH SIDE PANEL REMOVED) Fuse: Amp 0V AG Fast Acting POWER LED SYSTEM BUSY LED RECORDING LED PLAYING LED BACKGROUND MUSIC INPUT TIP / RING CTACT CLOSURE INPUT TIP / RING CTACT CLOSURE INPUT Expansion SW Options SW Options BSYMK BSYSW RECMK RECSW PLYMK PLYSW ABORT ABORT Loop Out Loop Out Line Out Line Out BGM BGM CTRL SW SW CTRL CTRL CTRL 8 8 POWER INPUT (-) -VDC BATTERY FEED BATTERY FEED (+) Ground VOX SENSITIVITY OPTI SWITCHES BUSY MAKE BUSY SWITCH RECORD MAKE RECORD SWITCH PLAY MAKE PLAY SWITCH ABORT CLOSURE INPUT BACKGROUND MUSIC LEVEL RJ for Expansion Output RJ for Expansion Input 00 OHM LOOP OUTPUT TO VALCOM PAGE CTROL UNIT OR OTHER DEVICES 8 OHM OUTPUT TO VALCOM SPEAKERS RING TIP RING TIP CTACT CLOSURE OUTPUTS System Access Inputs