SM300. Quick Start Guide Version 1.1. Soil Moisture and Temperature Sensor. Delta-T Devices Ltd

Similar documents
ML3 ThetaProbe. Quick Start Guide Version 1.0. Soil Moisture and Temperature Sensor. Delta-T Devices Ltd

SM150. Quick Start Guide Version 1. Soil Moisture Sensor. Delta-T Devices Ltd

SM200. Quick Start Guide Version 1.3. Soil Moisture Sensor. Delta-T Devices Ltd

SM150T. Quick Start Guide Version 2.0. Soil Moisture Sensor. Delta-T Devices Ltd

Irrigation Control. Quick Start Guide Version 2c. Using Soil Moisture Sensors. Delta-T Devices Ltd

RH and Air Temperature Sensor

GP1 Data Logger. Quick Start Guide v2.0. Delta-T Devices Ltd

SPN1 Sunshine Pyranometer

DL6 Data Logger. Quick Start Guide Version 1.2. Delta-T Devices Ltd

User Manual for the. Temperature Sensors TEMP-UM-2.1. Delta-T Devices Ltd

User Manual for the. SDI-12 Profile Probe. Type SDI PR2/4 and SDI PR2/6 PR2 SDI-12-UM-4.1. Delta-T Devices Ltd

BF5 Sunshine Sensor. Quick Start Guide version 1.0. Delta-T Devices Ltd

User Manual for the. Moisture Meter. type HH2. Version 4.0. Delta-T Devices Ltd

SKTS 200 Series Temperature Probes

Soil Moisture Measurement

Accsense Wireless System. Temperature Monitor

AC-43 Accelerometer. User Manual

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

Flow Sensor SONOFLOW CO.55

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

GP2 Data Logger. and Controller. Advanced capabilities

DeltaLINK 3 Release Notes

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

User Manual for the. M Enclosure for GP2. Type M-ENCL-B2. Delta-T Devices Ltd M-ENCL-B2 -UM-5.0

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

GP2 Data Logger. and Controller. Advanced capabilities

Environdata FA ma Converter Guide

Part Number N AEM 4-CH WIDEBAND UEGO CONTROLLER WITH NASCAR SPEC ECU CAN CONFIGURATION

NMEA Multiplexer Owner s Handbook. Document Number: Date: February 2005

VT-50. Linear Positioning Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

頤拓企業有限公司 TEL: TEKHNE TK-100 Dewpoint Transmitter. etorch Co., L. Users Manual. TEKHNE Corporation

I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature

Users Manual Ocean Sensor Systems Wave Staff III

VW2106 VW Readout Manual

StarFinder Aire User Manual

GP2 Data Logger Controller Research-grade logger controller - capable of complex calculated measurements and advanced feed-back control

User Manual for. GPRS Modem. Delta-T Devices Ltd GPRS-UM-3.0

LA Series In-line Linear Actuators

Installing Sentor. Hardware Installation

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

Installation Instructions for: Channel Thermocouple Amplifier

(see also technical drawings) Width with inlay

Technical Data Sheet SONOFLOW CO.55/xxxSD(H) V2.0

+GF+ SIGNET ph/orp Transmitter Instructions

PPS-28. Precision Piezo Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

MLC 420. MAGNETIC Press Brake ENCODERS OPERATION MANUAL

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

RS-WS-N01-TR Soil moisture temperature operation instruction (Type 485)

CDD Carbon Dioxide Transmitter

Temperature sensors TTM series. Miniature transmitters

Analog micro push button

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

GSV-1A4 M12/2 M12/2. Highlights

HD HD [ GB ] Probes for soil volumetric water content measurement. Temperature. Humidity PART OF G H M GROUP TELEMETRIE & AUTOMATION

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

MiniMux Multiplexer USER S GUIDE

VISY-X. Technical Documentation. Subsequent installation of VISY-Density. Edition: Version: 2 Art. No.:

rht+ RHTPlus CalComm Calibration Unit with Analogue Outputs

Hydrostatic filling level sensor HFB C4 / R / MD

100/140 Franker Link Unit Operator Manual

RADIOMETER PHOTOMETER L-420 INSTRUCTION MANUAL

Leak Sensor. TOYOKO KAGAKU CO., LTD. Kawasaki, Kanagawa, Japan

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

AWP-24 Wave Height Gauge User's Guide

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

6-Axis Force and Torque in All Six Axes 50N/1Nm to 50kN/5kNm Capacities Compact Size. Specifications

Draw wire sensors, draw wire sensors for displacement, position

MP 101A HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Portable Conductivity Meter M1410. User Manual 1.002

Hand-held thermometer Model CTH7000

S40 SERIES INSTRUCTION MANUAL

Fingertip Joystick. Single-axis joystick for easy and ergonomic actuation. Use. Variants

Never Beaten by Seasons

Adapter Kit - Remote QSI Electronics Installation Instructions

Zone Pressure Touch Sensor - Standard Range

Microminiature and Subminiature Gauging DVRT Quick Start Guide

PD 60 PIXEL DOT User s Manual & Installation Guide

DATA ACQUISITION Hints and Tips

Hand-held thermometer Model CTH7000

Multi-functional precision thermometer CTR3000

R-150 DMX Light Source

Microminiature and Subminiature DVRT Quick Start Guide

Component identification

IK4A (with ONDA technology)

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4

Inductive displacement measurement system model series IE25P with programmable analogue interface

VW MiniLogger

L-80 SERIES HOME & COMMERCIAL HIGH-TECH ENTERTAINMENT CENTER DIAGNOSTIC ADDENDUM

CDD4 Series Room CO2 Transmitter Installation Instructions

UNIVERSAL TEMPERATURE TRANSMITTER

Temperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/

Vibrating Wire Joint Meter Manual

midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM

Data Sheet A200 Series Electric Actuators

Using a HP02 with the Eagle Batching System

Transcription:

SM300 Soil Moisture and Temperature Sensor Quick Start Guide Version 1.1 Delta-T Devices Ltd

SM300 overview 3 HH2 4 Data loggers 1 Cables 2 Installation 2010 Delta-T Devices Ltd Page 2

1 Cables and Accessories brown white blue black grey green Power 0V Power V+ Signal HI Signal LO Temperature + Cable shield HH2 cable Extension cables Logger cable 1.5m 5m, 10m, 25m 5m bare end Extension cables can be joined up. See specifications for maximum length. Align connectors carefully before pushing parts together. Screw together firmly to ensure the connection is water-tight. 2 Installation Surface installation and spot measurements Clear away any stones. Pre-form holes in very hard soils before insertion. Push the SM300 into the soil until the rods are fully inserted. Ensure good soil contact. If you feel strong resistance when inserting the SM300, you have probably hit a stone. Stop, and reinsert at a new location. Installing at depth Auger a 45mm diameter hole. ~10 to vertical is recommended. Fit an extension tube to the SM300 remember to pass the cable through the extension tube and fit the connector first. Push the SM300 into the soil until rods are fully inserted. Ensure good soil contact. Alternatively Dig a trench, and install horizontally (see Overview diagram). Note: Extension tubes are available for installing the SM300 in an augered hole. 2010 Delta-T Devices Ltd Page 3

3 HH2 Meter Note the HH2 does not take SM300 temperature readings. Use version 2.5 or later of both the PC software HH2Read and the HH2 firmware if possible (or see footnotes). Connect the SM300 to the HH2 meter. Press Esc to turn the meter on, and if necessary press again until the HH2 displays the start-up screen. Set the meter to read from an SM300: Press Set and scroll down to the Device option. Press Set again and scroll down to select SM300. Press Set to confirm this choice. Device: SM300 Make sure the HH2 is correctly configured for your soil type: At the start-up screen, press Set and scroll down to the Soil Type option. Press Set again and scroll down to the appropriate soil type (use Mineral for sand, silt or clay soils or Organic for peaty soils) Press Set to confirm this choice. Soil Type: Mineral Choose the units you want for displaying readings: At the start-up screen, press Set and scroll down to the Display option. Press Set again and scroll down to select units. Press Set to confirm this choice. Press Read to take a reading. Press Store to save or Esc to discard the reading. SM300 20.3%vol Store? Remove the SM300 from the soil and move to a new location... If you have saved data, connect your HH2 to a PC and run HH2Read to retrieve the readings. Note: For an upgrade contact Delta-T. See also: Support for the SM300 Soil Moisture Sensor with an HH2, HH2 User Manual and HH2 User Manual Addendum to V4 - SM300. 2010 Delta-T Devices Ltd Page 4

4 Data Loggers GP1 2 SM300s can connect to each GP1. Each soil moisture sensor is wired as a differential, powered sensor. These details illustrate connection to Channels 1 and 3: SM300 wiring Power 0V Colour GP1 terminal brown CH1 (GND) or Temp (GND) Power V+ white CH1 (PWR) Signal HI blue CH1 (+) Signal LO black CH1 (-) Thermistor+ grey Temp3 (IN) Cable shield green CH1 (GND) Using DeltaLINK logger software (version 2.4* or later) configure channel 1 or 2 by choosing SM300 and channel 3 or 4 by choosing SM300 Temperature from the sensor menu. For configuration details see the GP1 Quick Start Guide. DL6 Up to 6 SM300s can connect to a DL6. Each soil moisture sensor is wired as a differential, powered sensor. A DL6 can only read one SM300 temperature sensor. These details illustrate connection to channels 6 & 7: SM300 wiring Colour DL6 terminal Power 0V brown 0V Power V+ white V+ Signal HI blue IN+ Signal LO black IN- Thermistor + grey RES IN+ Cable shield green Using DeltaLINK logger software (version 2.4* or later) configure channel 6 by choosing SM300 and channel 7 by choosing SM300 Temperature from the sensor menu. For configuration details see the DL6 User Manual. * Download the latest version of the DeltaLINK logger software from www.delta-t.co.uk or from our Softaware and Manuals CD issue 3 or later 2010 Delta-T Devices Ltd Page 5

DL2e Up to 30 SM300s each with a temperature sensor can be connected to a fully expanded DL2e logger. Up to 60 SM300 may be connected if not using the temperature sensor. Each moisture sensor is connected as a differential, powered sensor. These details illustrate connection to Channels 57 and 58 using a LAC1 input card configured in 15- channel mode, and warm-up channel 63: SM300 wiring Colour DL2e terminal Power 0V brown CH62- or 61- Power V+ white CH63 NO Signal HI blue CH58+ Signal LO black CH58- Thermistor + grey CH57+ and CH57- Cable shield green CH61- or 62- Configure the chosen DL2e logger channels by selecting the appropriate SM300 sensor types from the LS2Win sensor library. You need Ls2Win version 1.0 SR6 or later*. For configuration details see the DL2e User Manual. * Download the latest version of the Ls2Win logger software from www.delta-t.co.uk or from our Softaware and Manuals CD issue 3 or later Other data loggers Connect the SM300 soil moisture output as a differential powered sensor. Configure the logger input as a voltage sensor, using the lookup tables or polynomial coefficients on page 7. Connect the temperature sensor as a resistance sensor. Use a look-up table in the logger software to convert the measured resistance to temperature. θ 80% 60% 40% 20% See Appendix 2 of the SM300 User Manual 0% SM300 soil moisture readings in mineral and organic soils Organic Mineral 0.0 0.2 0.4 0.6 0.8 1.0 1.2 SM300 output (V) Note: The SM300 has been optimised for a 0.5 to 1 second warm-up period. Do not power the sensor continuously. 2010 Delta-T Devices Ltd Page 6

5 Convert SM300 Voltages to Soil Moisture Readings Note: The SM300 output is automatically converted to soil moisture when using an HH2 meter or Delta-T data loggers. Example Take a reading with the SM300 either Convert the reading to using the polynomial or linearisation table below. Then convert to soil moisture,, using the soil calibration values (a 0, a 1 ). V = 0.294 volts = 3.52 or Convert directly for mineral or organic soils = 22.9% Conversion to Polynomial (for use over the full range of SM300 readings) = 22.9% for mineral soil where V is the SM300 output in volts Linearisation table (for use over the full range of SM300 readings) V V V V V 0.000 1.000 0.300 3.556 0.600 4.956 0.900 6.471 1.200 7.961 0.075 1.963 0.375 3.913 0.675 5.327 0.975 6.841 1.275 8.411 0.150 2.641 0.450 4.254 0.750 5.708 1.050 7.205 1.350 8.971 0.225 3.149 0.525 4.598 0.825 6.092 1.125 7.571 1.425 9.724 Conversion from to Soil Moisture Soil moisture Use these generalised soil calibration values for mineral and organic soil types, or carry out a soilspecific calibration to derive your own values See SM300 User Manual. a 0 a 1 Mineral 1.6 8.4 Organic 1.3 7.7 Multiply x100 to convert soil moisture from m 3.m -3 to % volumetric. Direct conversion for Mineral and Organic soils 2010 Delta-T Devices Ltd Page 7

6 Specifications (for full specification see SM300 User Manual) Volumetric water content sensor Accuracy 2.5% vol over 0 to 50 % vol and 0-60 C * Measurement range 0 to 100% vol with reduced accuracy** Salinity error 3.5% vol over 50 to 1000 ms.m -1 and 0-40% vol Output signal 0-1V differential 0 to 60% nominal Output compatible with GP1, DL6, DL2e, HH2 SM300 must be fully buried to accurately measure soil Temperature sensor temperature Sensor accuracy 0.5 C over 0-40 C* not including logger or cabling error Output Resistance: 5.8kΩ to 28kΩ* Output compatible with GP1, DL6* DL2e Cabling error contribution (to temperature reading) 0 C for GP1 & DL6 (any cable length) 0 C for DL2e (with 5m cable).* Maximum cable length 100m (GP1 & DL6 data loggers) 100m (DL2e: water content measurement) 25m (DL2e: temperature measurement) Power requirement 5-14VDC, 18mA for 1s Operating range -20 to +60 C Environment IP68* Sample volume 55 x 70mm diameter Dimensions/Weight 143 x 40 mm diameter/ 0.1 kg * Note: See full specification in SM300 User Manual ** In water (no soil present) the reading may not be 100% vol. It depends on a0 and a1 but can still be used as a quick check that the unit is working. 7 Care and Safety Do not touch the rods or expose them to other sources of static damage, particularly when powered up. Keep the SM300 in its protective tube when not in use. Ensure that the connectors are clean, undamaged and properly aligned before pushing the parts together. Screw together firmly for water-tight seal. Do not pull the sensor out of the soil by its cable. If you feel strong resistance when inserting into soil, it is likely you have encountered a stone. Stop pushing and re-insert at a new location. Delta-T Devices Ltd 130 Low Road Burwell Cambridge CB25 0EJ England (UK) Tel: +44 1638 742922 Fax: +44 1638 743155 E-mail: sales@delta-t.co.uk Web: www.delta-t.co.uk