Cable Management Guide

Similar documents
Sun Control Station. Performance Module. Sun Microsystems, Inc. Part No September 2003, Revision A

Solaris 9 9/04 Installation Roadmap

Sun Management Center 3.6 Version 7 Add-On Software Release Notes

SunVTS Quick Reference Card

Sun StorEdge 3310 SCSI Array Best Practices Manual

Sun Management Center 4.0 Version 4 Add-On Software Release Notes

Sun StorEdge Network 2 Gb Brocade SilkWorm 3200 and 3800 Switches Release Notes

Sun Management Center 4.0 Version 3 Add-On Software Release Notes

StorageTek Host Software Component (HSC) MVS Software

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Sun StorEdge T3 Disk Tray Cabinet Installation Guide

Sun Fire V100 Server Product Notes

Solaris 8 6/00 Sun Hardware Roadmap

Sun Remote System Control (RSC) Release Notes

Sun Management Center 3.5 Supplement for VSP High-End Entry Servers (Workgroup Servers)

Sun Java System Connector for Microsoft Outlook Q4 Installation Guide

Sun Fire V20z Server Installation Guide

man pages section 6: Demos

Sun Fire V60x and V65x Servers ReadMe

Sun Netra TM X4200 M2 Server Product Notes

Memory Hole in Large Memory X86 Based Systems

Rackmount Placement Matrix

Sun Fire V125 Server Getting Started Guide

Sun Fire V60x and V65x BIOS and Firmware Update ReadMe

Sun Update Manager 1.0 Administration Guide

Sun Control Station. Software Installation. Sun Microsystems, Inc. Part No January 2004, Revision A

Sun Management Center 4.0 Version 2 Add-On Software Release Notes

Sun Fire V210 and V240 Servers Getting Started Guide

Solaris 8 User Supplement. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Sun Enterprise System 336-Mhz Processor Upgrade Instructions

Ultra Enterprise 6000/5000/4000 Systems Power Cord Installation

System Management Services (SMS) 1.6 Software Release Notes

Sun Fire High-End Server Systems Hold-down Kit

Sun Blade 1000 and Sun Blade 2000 Product Notes

UltraSPARC - IIs CPU Module Installation Guide

Sun Fire V490 Server Product Notes

Sun Cluster 2.2 7/00 Data Services Update: Lotus Domino 4.6.3

Sun Remote System Control (RSC) 2.2 Release Notes

Cluster Platform 15K/9960 System

Sun Rack Cabinet Extension Installation Guide

Java Desktop System Release 2 Installation Guide

Sun Blade 6048 Modular System Overview

Font Administrator User s Guide

Solaris 8 User Supplement. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Sun StorEdge Enterprise 2 Gb FC Single and Dual Port Host Bus Adapter Release Notes

Sun Multipath Failover Driver 1.0 for AIX User s Guide

Sun Fire System Controller Board, Version 2 (Enhanced Memory) Installation Guide

Font Administrator User s Guide. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Traditional Chinese Solaris Release Overview

Crypto Key Management Station

Java Desktop System Release 3 Troubleshooting Guide

Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix

Brocade 5100 Switch Hardware Release Notes

Sun Fire V490 Server Setup and Rackmounting Guide

Solaris 8 Desktop User Supplement. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Sun Patch Manager 2.0 Administration Guide for the Solaris 8 Operating System

Sun Fire V480 Server Product Notes

Scenario Planning - Part 1

The Solaris Security Toolkit - Quick Start

Sun Management Center 3.6 Supplement for the Sun Fire, Sun Blade, and Netra Systems

Sun Fire E2900 Systems Site Planning Guide

Sun Blade 1500 Product Notes

Solaris PC NetLink 1.2 Installation Guide

GNOME 2.0 Desktop for the Solaris Operating Environment Installation Guide

Simplified Chinese Solaris Release Overview

GNOME 2.0 Desktop for the Solaris Operating Environment User Guide

Sun StorEdge Traffic Manager 4.4 Software Installation Guide

Sun Fire X4600 Server Windows Operating System Installation Guide

Automating LDAP Client Installations

Provisioning in Replicated, Mission-Critical Environments

Sun Management Center 3.5 Service Availability Manager User s Guide

Sun Ultra 2 UltraSPARC -IIModuleX-Option

SunVTS Quick Reference Card

Sun StorageTek Backup Manager Release Notes

Security and Trust Services APIs for Java 2 Platform, Micro Edition

Sun StorEdgeT 3310 SCSI Array Release Notes

Sun Fire TM E2900 Systems Getting Started

Sun Ultra 2 UltraSPARC -II Module Upgrade

Solaris 8 Desktop User Supplement

SunPCi Release Notes

Sun StorEdge 5310 NAS Appliance Software Installation, Configuration, and User Guide

Sun Cooling Door 5200 Installation and User s Guide

4.0 Gbyte 1/4-Inch Tape Drive Specifications

WDR Installation Guide

Traditional Chinese Solaris Release Overview

Sun Fire E6900/E4900 Systems Overview

System Controller CPU Board, Netra CompactPCI, Installation Guide. Sun Fire E25K/E20K Systems Sun Fire 15K/12K Systems

Sun Streaming System Release Notes

man pages section 9: DDI and DKI Overview

Sun Java System Application Server Platform Edition Q2 Update 2 Release Notes

Sun StorEdge Network 2 Gb Brocade SilkWorm 3200, 3800, and Core Fabric Switches Guide to Documentation, 3.x / Firmware

Transitioning to Solaris PC NetLink 1.0

20-40 Gbyte 8mm Tape Drive Installation and User s Guide

Sun StorEdge RAID Manager 6.2 Installation and Support Guide

Sun Blade 2500 Workstation Product Notes

Sun Storage J4200/J4400 Array Hardware Installation Guide

Tales from the Trenches: The Case of the RAM Starved Cluster

Solaris Common Desktop Environment: User s Transition Guide. Sun Microsystems, Inc Garcia Avenue Mountain View, CA U.S.A.

Sun Management Center 3.0 Service Availability Manager User s Guide

Solaris Common Desktop Environment: User s Transition Guide

Transcription:

Cable Management Guide Sun Fire High End Server Systems Sun Microsystems, Inc. www.sun.com Part No. 817-1753-11 July 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback

Copyright 2005 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries. This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, Sun Fire, Java, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. U.S. Government Rights-Commercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and applicable provisions of the FAR and its supplements. DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 2005 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la limitation, ces droits de propriété intellectuels peuvent inclure un ou plus des brevets américains énumérés à http://www.sun.com/patents et un ou les brevets plus supplémentaires ou les applications de brevet en attente dans les Etats-Unis et dans les autres pays. Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, parquelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y ena. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d autres pays et licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, Sun Fire, Java, et Solaris sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc. aux Etats-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface d utilisation graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développment du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique. Sun détient une license non exclusive do Xerox sur l interface d utilisation graphique Xerox, cette licence couvrant également les licenciées de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun. LA DOCUMENTATION EST FOURNIE "EN L ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFAÇON.

Contents 1. Cable Management 1 1 1.1 Tools 1 1 1.2 Cable Straps 1 2 1.3 Installing the Permanent Cable Straps 1 3 1.4 Installing the Service Cable Straps 1 6 1.4.1 Systems With Four Doors (Two in Front) 1 6 1.4.1.1 For the Front of the System 1 6 1.4.1.2 For the Rear of the System 1 8 1.4.2 Systems With Two Doors (One in Front) 1 9 1.4.2.1 For the Front of the System 1 9 1.4.2.2 For the Rear of the System 1 10 1.5 Using the Cable Straps 1 10 1.6 Uninstalling the Green Cable Straps 1 11 1.6.1 Systems With Four Doors (Two in Front) 1 11 1.6.1.1 For the Front of the System 1 11 1.6.1.2 For the Rear of the System 1 11 1.6.2 Systems With Two Doors (One in Front) 1 12 1.6.2.1 For the Front of the System 1 12 1.6.2.2 For the Rear of the System 1 12 iii

iv Cable Management Guide July 2005

CHAPTER 1 Cable Management The cable management kit provides orderly cable management. With this kit, component maintenance can be accomplished by one technician. The book contains the following sections: Tools on page 1 Cable Straps on page 2 Installing the Permanent Cable Straps on page 3 Installing the Service Cable Straps on page 6 Using the Cable Straps on page 10 Uninstalling the Green Cable Straps on page 11 1.1 Tools Side-cutting pliers Screwdriver (supplied in system shipping kit, or equivalent) 1-1

1.2 Cable Straps In the kit, there are six variations of cable straps to manage the system cables (TABLE 1-1). One kit supplies enough cable straps (with spares) to manage the front of the Sun Fire system. To supply the front and rear of the system, two kits are required. The following procedures apply to the front and rear of the Sun Fire system. The Strap ID Numbers are printed on the straps. TABLE 1-1 Straps Cable Management Kit Contents Strap ID Number Description Number Per Kit Black Management 3 4 6.0 in. (15.2 cm) black cable hanger strap with tie wrap 6.0 in. (15.2 cm) (.5 in. wide) black lite cable strap 12 11 5 10.0 in. (25.4 cm) black cable strap 16 Green Maintenance 1 2 12 in. (30.48 cm) green cable hanger straps 51.0 in. (129.5 cm) green buckle strap; rear door maintenance straps 4 2 6 18 in. (14.7 cm) green cable straps 6 Cable Management Bracket Assembly Metal brackets used with two door (one in front) systems. 2 1-2 Cable Management Guide July 2005

1.3 Installing the Permanent Cable Straps 1. Open the cabinet door. 2. Secure the black cable hanger strap with tie wrap (No. 3) to the cutouts of the air plenum using the tie wrap (FIGURE 1-1) These straps should hang directly below each I/O board to accommodate the cables hanging from each board.. FIGURE 1-1 Black Cable Hanger Strap With Tie Wrap at Air Plenum 3. Use side-cutting pliers to cut off the ends of the tie wraps at the air plenum. Chapter 1 Cable Management 1-3

4. Just below the I/O board attach a black cable strap (No. 5) to one of the cables and wrap the strap around the remaining cables in the I/O board set to bind all of the cables together (FIGURE 1-2). The system control (SC) cables should be allowed to hang freely. Note The cables for each system board should be bundled together as a set. This allows ease of access and removal of a single I/O board set without disturbing the adjacent board set cables. 5. Vertically secure each of the bundled cable sets and the SC cables to the black cable hanger straps (FIGURE 1-2). The cable hanger straps were attached in Step 2. 6. At the top of the power supplies, secure a black lite cable strap (No. 4) to one of the cables and wrap the strap around the remaining cables in the cable set to bind all of the cables together (FIGURE 1-2). Include the SC cables when wrapping the cables for slot SB0 on the front of the system or slot SB9 on the rear of the system. 7. At the base of the system, secure a black cable strap (No. 5) to one of the cables and wrap the strap around the cables in two cable sets to bind the two sets together (FIGURE 1-2). 8. Repeat Step 3 through Step 7 for the remaining I/O boards. For a fully populated system, you should have nine sets of cables hanging vertically at the front or rear of the system. Note Leave ample cable slack below the floor tiles so the cables can be easily moved out of the way for component service and maintenance. Ensure no sharp edges are on the floor tile cutout. Be careful moving components in and out of the system as sharp edges could damage cables. 9. Secure a black cable strap (No. 5) to one of the cable bundles below the tile floor and wrap the strap around the three bundles to bind them together (FIGURE 1-2). 1-4 Cable Management Guide July 2005

No. 5 No. 3 No. 4 No. 5 FIGURE 1-2 Black Permanent Straps 10. At the center of the air plenum cutouts, secure two green cable hanger straps (No. 1), with tie wrap to the cutouts of the air plenum (FIGURE 1-3). On the front of the system secure these tie wraps between slot SB4 and SB5 and between slot SB2 and SB3. On the rear of the system secure these tie wraps between slot SB11 and SB12 and between SB13 and SB14. No. 1 FIGURE 1-3 Green Cable Hanger Strap With Tie Wrap at Air Plenum Chapter 1 Cable Management 1-5

1.4 Installing the Service Cable Straps Green maintenance straps are for service only and should not be left in the system. A location should be determined and the straps stored at the site. This section describes the installation procedures for: Systems With Four Doors (Two in Front) Systems With Two Doors (One in Front) 1.4.1 Systems With Four Doors (Two in Front) 1.4.1.1 For the Front of the System 1. Remove the screws located second from the bottom and eleventh from the bottom of the cabinet door on the left. 2. Use the screws recovered from Step 1 to secure two green cable straps (No. 6) to the holes opened in Step 1 (FIGURE 1-4). The screws should be turned no more than 3.0 revolutions to prevent the stripping of the internal door material. 3. Remove the screws located second from the bottom and tenth from the bottom of the cabinet door on the right. 4. Use the screws recovered from Step 3 to secure two green cable straps (No. 6) to the holes opened in Step 3 (FIGURE 1-4). 1-6 Cable Management Guide July 2005

No. 6 FIGURE 1-4 Front Door Maintenance Straps Chapter 1 Cable Management 1-7

1.4.1.2 For the Rear of the System The buckle end of the green buckle strap (No. 2) that is used at the top crossbar of each rear door measures approximately 17.0 in. (43.2 cm). The other end that used to hold the cables measures approximately 12.0 in. (30.5 cm). 1. Attach the green buckle strap (No. 2) to the top crossbar on the hinged side of the cabinet door on the left (FIGURE 1-5). a. Insert the 17.0 in. (43.2 cm) end of the strap, buckle facing toward you, underneath and over the crossbar, and insert the end through the buckle. b. Loosely secure the strap. This strap should be pushed close to the hinged side of the door to retain proper tension when the cables are held during maintenance. 2. Attach the green buckle strap (No. 2) to the top crossbar on the hinged side of the cabinet door on the right (FIGURE 1-5). a. Insert the 17.0 in. (43.2 cm) end of the strap, buckle facing toward you, underneath and over the crossbar, and insert the end through the buckle. b. Loosely secure the strap. This strap should be pushed close to the hinged side of the door to retain proper tension when the cables are held during maintenance. No. 2 FIGURE 1-5 Rear door maintenance strap 1-8 Cable Management Guide July 2005

1.4.2 Systems With Two Doors (One in Front) 1.4.2.1 For the Front of the System 1. Remove the pushbar (if it s still attached) 2. Remove the screws located second from the bottom and eleventh from the bottom on the cabinet door. 3. Use the screws recovered from Step 2 to secure two green cable straps (No. 6) to the holes opened in Step 2 (FIGURE 1-6). The screws should be turned no more than 3.0 revolutions to prevent the stripping of the internal door material. 4. Secure the two cable management brackets to the holes on the right side of the cabinet (FIGURE 1-6). The brackets have captive fasteners that can be tightened by hand. 5. Use the included phillips screws to secure a green cable strap (No. 6) to the holes at the end of each of the cable management brackets (FIGURE 1-6). No. 6 No. 6 FIGURE 1-6 Installing the Maintenance Brackets and Straps Chapter 1 Cable Management 1-9

1.4.2.2 For the Rear of the System The buckle end of the green buckle strap (No. 2) that is used at the top crossbar of the door measures approximately 17.0 in. (43.2 cm). The other end that used to hold the cables measures approximately 12.0 in. (30.5 cm). 1. Attach the green buckle strap (No. 2) to the top crossbar on the hinged side of the door (FIGURE 1-5). a. Insert the 17.0 in. (43.2 cm) end of the strap, buckle facing toward you, underneath and over the crossbar, and insert the end through the buckle. b. Loosely secure the strap. This strap should be pushed close to the hinged side of the door to retain proper tension when the cables are held during maintenance. 2. Secure the two cable management brackets to the holes on the right side of the cabinet (FIGURE 1-6). The brackets have captive fasteners that can be tightened by hand. 3. Use the included phillips screws to secure a green cable strap (No. 6) to the holes at the end of each of the cable management brackets (FIGURE 1-6). 1.5 Using the Cable Straps 1. Release the I/O cable bundles from the black cable hanger straps of the air plenum (No. 4) and lift the cable bundles upward to obtain cable slack from beneath the tile floor. Caution Avoid excessive strain on the I/O cable connectors. 2. Secure the I/O cable bundles with the green maintenance straps. Ensure the cables are held tight and that ample room is provided to gain access to the air plenum panel. 3. Perform maintenance on the system. Refer to the system service manual for the component maintenance procedures. 1-10 Cable Management Guide July 2005

1.6 Uninstalling the Green Cable Straps Green maintenance straps are for service only and should not be left in the system. A location should be determined and the straps stored at the site. This section describes the uninstallation procedures for: Systems With Four Doors (Two in Front) Systems With Two Doors (One in Front) 1.6.1 Systems With Four Doors (Two in Front) 1.6.1.1 For the Front of the System 1. Release the I/O cable bundles from the green maintenance strap and resecure them to their former black cable hanger straps on the air plenum. 2. Remove the two screws that secure the green cable straps (No. 6) to the cabinet door on the left and store the green straps for future use. 3. Remove the two screws that secure the green straps (No. 6) to the cabinet door on the right and store the green straps for future use. 4. Secure the four screws in their original locations on the cabinet doors. 5. Close the cabinet doors. 1.6.1.2 For the Rear of the System The buckle end of the green buckle strap (No. 2) that is used at the top crossbar of the door measures approximately 17.0 in. (43.2 cm). The other end that used to hold the cables measures approximately 12.0 in. (30.5 cm). 1. Release the I/O cable bundles from the green buckle straps (No. 2) and resecure them to their former black cable hanger straps on the air plenum. 2. Release the buckle and remove the green buckle strap (No. 2) from the top crossbar on the hinged side of the cabinet door on the left (FIGURE 1-5). 3. Release the buckle and remove the green buckle strap (No. 2) from the top crossbar on the hinged side of the cabinet door on the right (FIGURE 1-5). 4. Close the cabinet doors. Chapter 1 Cable Management 1-11

1.6.2 Systems With Two Doors (One in Front) 1.6.2.1 For the Front of the System 1. Release the I/O cable bundles from the green maintenance strap and resecure them to their former black cable hanger straps on the air plenum. 2. Remove the two screws that secure the green cable straps (No. 6) to the cabinet door on the left and store the green straps for future use. 3. Secure the two screws in their original locations. 4. Remove the two screws that secure the green cable straps (No. 6) to the cable management brackets and store the straps and screws for future use. 5. Remove the cable management brackets and store them for future use (FIGURE 1-6). The brackets have captive fasteners that can be loosened by hand. 6. Close the cabinet doors. 1.6.2.2 For the Rear of the System The buckle end of the green buckle strap (No. 2) that is used at the top crossbar of the door measures approximately 17.0 in. (43.2 cm). The other end that used to hold the cables measures approximately 12.0 in. (30.5 cm). 1. Release the I/O cable bundles from the green maintenance strap and resecure them to their former black cable hanger straps on the air plenum. 2. Release the buckle and remove the green strap from the top crossbar on the hinged side of the cabinet door (FIGURE 1-5). 3. Remove the two screws that secure the green cable straps (No. 6) to the cable management brackets and store the straps and screws for future use. 4. Remove the cable management brackets and store them for future use (FIGURE 1-6). The brackets have captive fasteners that can be loosened by hand. 5. Close the cabinet doors. 1-12 Cable Management Guide July 2005