1U Device Expansion Unit Configuration Guide

Similar documents
NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320b-M4 Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320e-E4 Configuration Guide

NEC Express5800/R120d-2M Configuration Guide

NEC Express5800/GT110e Configuration Guide

NEC EXPRESS5800/R320c-M4 Configuration Guide

NEC EXPRESS5800/R140b-4 Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide

NEC EXPRESS5800/GT110d-S Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320b-M4 Configuration Guide

NEC Express5800/R320f Configuration Guide

NEC EXPRESS5800/E110d-1 Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/GT110e-S Configuration Guide

NEC EXPRESS5800/R320e-E4 Configuration Guide

NEC Express5800/R320g Configuration Guide

NEC Express5800/R120e-2E Configuration Guide

NEC Express5800/GT110e-S Configuration Guide

NEC Express5800/B120f-h System Configuration Guide

NEC Express5800/R120h-2E System Configuration Guide

NEC EXPRESS5800/R320d-E4 Configuration Guide

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.)

Dell MD1280 Storage Enclosure Getting Started Guide

FibreCAT TXF. December System configurator and order-information guide. Contents. PRIMERGY Server

NEC Server Rack Configuration Guide

Data Sheet FUJITSU Storage ETERNUS JX60 Subsystem

NEC EXPRESS5800/R320d-E4 Configuration Guide

NEC Express5800/R120h-1M System Configuration Guide

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

Part Number Unit Descriptions

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

NEC Express5800/R120f-1M System Configuration Guide

QuickSpecs. Models. Overview

NEC Express5800/T110h-S System Configuration Guide

QuickSpecs HP Disk System 2120

DNS-2608 Enterprise JBOD Enclosure User Manual

ServeRAID-BR10i SAS/SATA Controller and IBM 3Gb SAS HBA v2 - New family of RAID controllers for System x servers

Acer AR320 F1 specifications

Data Sheet FUJITSU JX60 S2 DAS Subsystem

NEC Express5800/B110d Configuration Guide

EMC1600 Series Media Converter and Ethernet Extender Chassis

Dell Inspiron 580: Comprehensive Specifications

Data Sheet FUJITSU Storage ETERNUS JX40 S2 Subsystem

NEC Express5800/B120e-h System Configuration Guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here

NEC Express5800/E120b-1 Configuration Guide

Dell Inspiron 300/400 Comprehensive Specifications

Acer AT110 F2 Specifications

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

NEC Express5800/D120h System Configuration Guide

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

NEC Express5800/R120h-2M System Configuration Guide

Express5800/ A2040c/A2020c/A2010c/A1040c Configuration Guide

QuickSpecs. Model Host Bus Adapter HP H222 Host Bus Adapter B21. HP H222 Host Bus Adapter. Overview

SAS JBOD Installation Reference Guide Revision 1.0

NEC Express5800/B120d-h System Configuration Guide

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

High Performance Computing

USB 3.0 / esata Dual-Bay Trayless 3.5 SATA III Hard Drive Enclosure with UASP - 2-Bay SATA 6 Gbps Hot-Swap HDD Enclosure

Dell PowerVault NX Windows NAS Series Configuration Guide

HP ProLiant MicroServer

NEC Express5800/R120d-1M Configuration Guide

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

MH70I Rugged 19" Modular Industrial PC

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

HostEngine 5URP24 Computer User Guide

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017.

NEC Express5800/R120h-1E System Configuration Guide

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

QuickSpecs. HPE Rack-mount Kits. Overview. HPE StoreEver Rack-mount Kits. 1U Rack-mount Kit. What's New

N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide

Altos R320 F3 Specifications. Product overview. Product views. Internal view

QuickSpecs. What's New. Models. Overview

4 Port PCI Express PCIe SuperSpeed USB 3.0 Controller Card Adapter with UASP - SATA Power

The PEXUSB3S2 PCI Express USB 3.0 card lets you add two USB 3.0 ports to your PC through a PCI Express slot.

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

IBM Half-High LTO Generation 5 SAS Tape Drive IBM System x at-a-glance guide

The HP Thunderbolt 2 PCIe Card is backward compatible to allow your Thunderbolt devices to operate with no cable adapters needed.

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Dell Storage NX Windows NAS Series Configuration Guide

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

QuickSpecs. What's New New HP221 PCIe 3.0 SAS HBA

QuickSpecs. HP 50 Modular Smart Array Enclosure. Overview

USB 3.0 / esata Dual-Bay Trayless 3.5 SATA III Hard Drive Enclosure with UASP - 2-Bay SATA 6 Gbps Hot-Swap HDD Enclosure

USB 3.0 / esata 8-Bay Hot-Swap 2.5/3.5 SATA III Hard Drive Enclosure with UASP 8-Bay SATA 6 Gbps Enclosure for HDD / SSD

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

Dell SC460 Expansion Enclosure Getting Started Guide

System Configuration and order-information Guide RX600 S3. February 2007

The PEXUSB3S11 PCI Express USB 3.0 Card lets you add one internal, and one external USB 3.0 port to your PC through a PCI Express slot.

HP Storage Solutions for HP Business Notebooks Overview. Models HP SuperMulti (DL) DVD+/-RW SATA LightScribe Drive

QuickSpecs. HPE H220 Host Bus Adapter. Overview. Model Host Bus Adapter HP H220 Host Bus Adapter B21

QuickSpecs. HP 1x4 USB/PS2 KVM Switch. HP 1x4 USB/PS2 KVM Switch. Models HP 1x4 USB/PS2 KVM Switch

Transcription:

1U Device Expansion Unit Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your storage system. August 30, 2017 Revision 3.0 NEC Corporation

Contents TECHNICAL SPECIFICATION... 3 Key Features... 3 Specification... 3 EXTERNAL VIEWS... 4 Front and Rear Views... 4 Dimensions (mm)... 5 UNIT CONFIGURATION... 6 1 External Tape Drive Enclosure... 6 1.1 Tape Drive Configuration... 6 1.2 SAS Tape Drive Configuration... 7 1.3 USB RDX Drive Configuration... 9 1.4 SAS and USB Tape/RDX Drive Configuration... 11 COPYRIGHT NOTICE AND LIABILITY DISCLAIMER... 13 REVISION HISTORY... 14 NEC Corporation Revision 3.0 August, 2017 2

Technical Specification Key Features Affordable direct attached data protection solution for rack mount systems Two 5-inch half height drive bays in 1U enclosure Flexible configuration with SAS and USB tape drive installation Superior reliability with redundant power supplies Specification Model 1U Device Expansion Unit Part Number 5-inch Media Bays 2 Redundant Power Supply Power Supply Dimensions (W x D x H ) Maximum Power Consumption Maximum Weight N8141-69F Optional, non-hot plug 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 424.0 x 578.1 x 44.0 mm / 16.7 x 22.7 x 1.7 in (1U) 328VA 6.1 kg, 13.45 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10 to 40 C / 50 to 104 F, 10 to 80% Non-Operating: -10 to 55 C / 14 to 131 F, 10 to 80% NEC Corporation Revision 3.0 August, 2017 3

External Views Front and Rear Views Front View A B C D E I F G H I Legend A. Power Switch 1 F. Error Status LED B. Ready LED G. Power Unit 2 Status LED C. Power Unit 1 Status LED H. Fan Unit 2 Status LED D. Fan Unit 1 Status LED I. Drive Bays E. Power Switch 2 Rear View B A C D E Legend A. AC Inlet D. External Connector 1 B. AC Inlet (Optional) E. External Connector 3 C. External Connector 2 NEC Corporation Revision 3.0 August, 2017 4

44 578 551 CONFIGURATION GUIDE 1U Device Expansion Unit Dimensions (mm) 425 484 NEC Corporation Revision 3.0 August, 2017 5

Unit Configuration 1 External Tape Drive Enclosure 1.1 Tape Drive Configuration Refer to the section in accordance with type of tape drives installed and number of host adapters. Type of Tape Drives Number of Host Adapters Section Internal LTO One SAS HBAs 1.2.1 Two SAS HBAs 1.2.2 Internal RDX One USB HBAs 1.3.1 Two USB HBAs 1.3.2 Mixing internal LTO and RDX Drives One SAS and one /USB HBAs 1.4 The tape drive enclosure can be shared with up to two servers, HBAs. See the figures below for typical tape drive bays configuration. Two HBA Configuration To HBA To HBA SAS Interface SAS Interface NEC Corporation Revision 3.0 August, 2017 6

1.2 SAS Tape Drive Configuration 1.2.1 One SAS HBA Connection Diagram Server Device Expansion Unit PCI Slot Internal Bay #1 Bay #2 P2 Redundant Power Supply Product List Category Product Name / Description Part Number Storage Controller Enclosure Power Supply Recommended Drive 2 slots available LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 1 x LSILogic SAS9300-8e 12Gb/s SAS, 8(SFF-8644), PCIe3.0(x8) 12Gb/s SAS, Ext. 8(SFF-8644), PCIe3.0(x8) LSI SAS9300-8e 12Gb/s SAS, Ext. 8(SFF-8644), PCIe3.0(x8) External 2 m, 1 x SFF-8088 to 1 x SFF-8088 External SAS cable 2 m, 1x Mini SAS HD -1x Mini SAS 1U Device Expansion Unit 2 x 5-inch media bays Power Unit non-hot plug power supply Internal 1 x SFF-8088 to 2 x SFF-8482, mount bracket included LTO3, Half height, Native capacity 400 GB LTO4, Half height, Native capacity 800 GB LTO5, Half height, Native capacity 1.5 TB LTO6, Half height, Native capacity 2.5 TB LTO7, Half height, Native capacity 6 TB LTO5, Half height, Native capacity 1.5 TB LTO6, Half height, Native capacity 2.5 TB LTO7, Half height, Native capacity 6 TB N8103-142 N8803-041 N8103-197 N8103-184 K410-191(02) K410-322(02) N8141-69F N8181-124F K410-335(00) N8151-126 N8151-127 N8151-128 N8151-129 N8151-136 N8151-141 N8151-142 N8151-143 Refer to the system configuration of the server to select the appropriate SAS controller and internal LTO drive. Choose the appropriate SAS cable as follows: K410-191(02): N8103-142 K410-322(02): N8803-041, N8103-197, and N8103-184 NEC Corporation Revision 3.0 August, 2017 7

1.2.2 Two SAS HBA Connection Diagram Server Device Expansion Unit PCI Slot PCI Slot Internal Bay #1 Bay #2 P2 Redundant Pow er Supply Product List Category Product Name / Description Part Number Storage Controller 2 2 Enclosure Power supply Recommended 2 Drive 2 slots available LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 1 x LSILogic SAS9300-8e 12Gb/s SAS, 8(SFF-8644), PCIe3.0(x8) 12Gb/s SAS, Ext. 8(SFF-8644), PCIe3.0(x8) LSI SAS9300-8e 12Gb/s SAS, Ext. 8(SFF-8644), PCIe3.0(x8) External 2 m, 1 x SFF-8088 to 1 x SFF-8088 External SAS cable 2 m, 1x Mini SAS HD -1x Mini SAS 1U Device Expansion Unit 2 x 5-inch media bays Power Unit non-hot plug power supply Internal 1 x SFF-8088 to 2 x SFF-8482, mount bracket included LTO3, Half height, Native capacity 400 GB LTO4, Half height, Native capacity 800 GB LTO5, Half height, Native capacity 1.5 TB LTO6, Half height, Native capacity 2.5 TB LTO7, Half height, Native capacity 6 TB LTO5, Half height, Native capacity 1.5 TB LTO6, Half height, Native capacity 2.5 TB LTO7, Half height, Native capacity 6 TB N8103-142 N8803-041 N8103-197 N8103-184 K410-191(02) K410-322(02) N8141-69F N8181-124F K410-335(00) N8151-126 N8151-127 N8151-128 N8151-129 N8151-136 N8151-141 N8151-142 N8151-143 Refer to the system configuration of the server to select the appropriate SAS controller and internal LTO drive. Choose the appropriate SAS cable as follows: K410-191(02): N8103-142 K410-322(02): N8803-041, N8103-197, and N8103-184 NEC Corporation Revision 3.0 August, 2017 8

1.3 USB RDX Drive Configuration 1.3.1 One USB Port Connection Diagram Server USB Connector USB Cable Bay #1 Bay #2 P2 Device Expansion Unit Redundant Power Supply Product List Category Product Name / Description Part Number Storage Controller USB Cable Enclosure Power Supply Recommended Drive 1 slot available External USB Controller 1 x USB port External USB Cable USB 2.0, 2 m, 1 x external USB to 1 x USB device, mount bracket included External USB Cable USB3.0,1.17 m, 1 x external USB to 1 x USB device, mount bracket included - The cable is required to connect with a USB3.0 port. 1U Device Expansion Unit 2 x 5-inch media bays Power Unit non-hot plug power supply (Standard) K410-197(00) K410-307(1A) N8141-69F N8181-124F Internal RDX (USB) N8151-125 Internal RDX (USB) N8151-139 Choose the appropriate USB cable according to the USB connector on the server. Refer to the system configuration of the server to select the appropriate internal RDX drive. NEC Corporation Revision 3.0 August, 2017 9

1.3.2 Two USB Ports Connection Diagram Server USB Connector USB Cable Bay #1 Bay #2 P2 Device Expansion Unit Redundant Pow er Supply USB Connector USB Cable Product List Category Product Name / Description Part Number Storage Controller USB Cable 2 Enclosure Power Supply Recommended Drive 1 slot per HBA available External USB Controller 1 x USB port External USB Cable USB 2.0, 2 m, 1 x external USB to 1 x USB device, mount bracket included External USB Cable USB3.0,1.17 m, 1 x external USB to 1 x USB device, mount bracket included - The cable is required to connect with a USB3.0 port. (Standard) K410-197(00) K410-307(1A) 1U Device Expansion Unit N8141-69F 2 x 5-inch media bays Power Unit N8181-124F non-hot plug power supply Internal RDX (USB) N8151-125 Internal RDX (USB) N8151-139 Choose an appropriate USB cable according to the USB connector on the server. Refer to the system configuration of the server to select the appropriate internal RDX drive. NEC Corporation Revision 3.0 August, 2017 10

1.4 SAS and USB Tape/RDX Drive Configuration Connection Diagram Server Device Expansion Unit PCI Slot Internal Bay #1 Bay #2 P2 Redundant Pow er Supply USB Connector USB Cable Product List Category Product Name / Description Part Number Storage Controller Storage Controller USB Cable Enclosure Power Supply Recommended Drive 1 slot per HBA available LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 1 x LSILogic SAS9300-8e 12Gb/s SAS, 8(SFF-8644), PCIe3.0(x8), Low Profile / Full Height 12Gb/s SAS, Ext. 8(SFF-8644), PCIe3.0(x8) LSI SAS9300-8e 12Gb/s SAS, Ext. 8(SFF-8644), PCIe3.0(x8) External USB Controller 1 x USB port External 2 m, 1 x SFF-8088 to 1 x SFF-8088 External SAS cable 2 m, 1x Mini SAS HD -1x Mini SAS External USB Cable USB 2.0, 2 m, 1 x external USB to 1 x USB device, mount bracket included External USB Cable USB3.0,1.17 m, 1 x external USB to 1 x USB device, mount bracket included - The cable is required to connect with a USB3.0 port. N8103-142 N8803-041 N8103-197 N8103-184 (Standard) K410-191(02) K410-322(02) K410-197(00) K410-307(1A) 1U Device Expansion Unit N8141-69F 2 x 5-inch media bays Power Unit N8181-124F non-hot plug power supply Internal K410-335(00) 1 x SFF-8088 to 2 x SFF-8482 LTO N8151-126 LTO3, Half height, Native capacity 400 GB N8151-127 LTO4, Half height, Native capacity 800 GB N8151-128 LTO5, Half height, Native capacity 1.5 TB N8151-129 LTO6, Half height, Native capacity 2.5 TB N8151-136 LTO7, Half height, Native capacity 6 TB N8151-141 LTO5, Half height, Native capacity 1.5 TB N8151-142 LTO6, Half height, Native capacity 2.5 TB N8151-143 LTO7, Half height, Native capacity 6 TB RDX Internal RDX (USB) N8151-125 NEC Corporation Revision 3.0 August, 2017 11

Internal RDX (USB) N8151-139 Refer to the system configuration of the server to select the appropriate SAS controller and internal LTO drive. Choose the appropriate SAS cable as follows: K410-191(02): N8103-142 K410-322(02): N8803-041, N8103-197, and N8103-184 Choose an appropriate USB cable according to the USB connector on the server. Refer to the system configuration of the server to select the appropriate internal RDX drive. NEC Corporation Revision 3.0 August, 2017 12

Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. NEC Corporation Revision 3.0 August, 2017 13

Revision History Revision Date Description 3.0 August 30, 2017 New products added: / N8151-141 / N8151-142 / N8151-143 Internal RDX (USB) / N8151-139 Others: Added and cable information for new servers. 2.0 July 20, 2016 New products added: / N8151-136 Others: Added and cable information for R320e. 1.0 October 23, 2015 Initial release NEC Corporation Revision 3.0 August, 2017 14