BSPD Surge Protective Devices

Similar documents
Eaton s SPD Series for integration into electrical distribution equipment

Remote contact signaling available. visual status indication

BUSSMANN. North American UL Type 1, 2 and 4, and data signal surge protective devices SERIES. Application note 3193

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

The protection you rely on

Instruction Manual IM E Table of Contents

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

SECTION SURGE PROTECTIVE DEVICES

Internal Modular SPDs

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Eaton SPD Series. Instruction Manual IM E Effective June 2014 Rev. 2

Specifications, Installation, and Operating Instructions

Innovative Technology line filters and surge protectors

Eaton SPD Series. for Mounting External to Electrical Distribution Equipment. Instruction Manual IM E Effective March 2014 Rev.

Clipper Power System Visor Series

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Surge Protective Devices. STV25K Series. Instruction Manual

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

MIL STD 220a (50 Ohm) Model Ordering: 400LS - 277Y - DS - UFP - MX

ZoneMaster Series Surge Protection Devices

OVRH catalog Surge protective devices

GE Digital Energy. Power Quality

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Installation and Operation Manual

B. System Design and Performance Requirements

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

SURGELOGIC TM. Surge Protective Device Transient Voltage Surge Suppressor (TVSS) XGA, XT, XF, XP Series. Class Schneider Electric Brands

THE SURGE PROTECTION SOLUTION

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

R-LB R-LX Series Installation, Operation & Maintenance Manual

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

Panelmount (Facility-Wide) Surge Protection

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Instruction Manual: IM E

Surgelogic Surge Protective Devices LC, XR, and XW Series

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical

Surge Protection Devices OVR series

Hubbell Surge Protective DeviceS

GUIDE TO VERIFYING SURGE PROTECTIVE DEVICES INSTALLED IN LIGHTNING PROTECTION SYSTEM INSTALLATIONS ARE COMPLIANT WITH UL 96A.

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Installation and Operation Manual

Surge Protective Devices (SPD)

TDX Series. Transient Discriminating TM TVSS

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

TransGuard. Electrical Transient Suppression Filter Systems. Installation, Operation and Maintenance Manual PN ,

NEMA 1 / IP40 metal housing. Compact design

Surge Protection Solutions. Industrial Market Automation Market OEM Market

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Figure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.

Protect your facility from the destructive effects of power surges with a fully

SECTION DISTRIBUTION SWITCHBOARDS

Eaton Innovative TechnologyT XT50/100 surge protective device

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

60103 Circuit Breaker

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

SSMx24 Series 240 ka Per Phase Peak Surge Current ANSI/UL1449 UL Fourth Edition

Installation Instructions & User Manual

Surge Protective Devices

PDI Modular Compact Remote Power Panel

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

Overvoltage Protective Devices

Ferraz Shawmut TPMOV Principles and Operation

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Surge Protection Devices (SPD)

AC and DC Protector Applications

Protecting the electronic world from surges

SECTION SWITCHBOARDS

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

Joslyn Surge Protection Products

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

PHOENIX CONTACT Features

S66 Series Electronic Fan Speed Control

Instruction Bulletin Boletín de instrucciones Directives d'utilisation , Rev. 02, 03/2016

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

White Paper Surge Protective Devices in Automatic Transfer Switches

Grid to Chip Surge Protection Product Catalog

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

MiniEVR Electronic Voltage Regulator-Power Conditioner (MEVR)

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Technical Data Sheet Medium Current Power Surge Filters

Transcription:

BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features 2 Standards and certifications 2 Configuration 3 Enclosure options, dimensions, and weights 3 Voltage protection ratings 4-5 Specifications 6 Catalog number 7 Technical support information 7

BSPD SPDs for overvoltage protection on Introduction The BSPD Series of surge protective devices are tested by Underwriters Laboratory and Listed to UL 1449, 4th Edition to help ensure equipment is protected with highly reliable surge protection technology. Delta and Wye units are available in three configurations to increase application flexibility. The BSPD Series is for installation external to an electrical enclosure or panelboard. Application of BSPD Series units throughout a facility will help ensure that equipment is protected. Applications BSPD Series units are available for common Delta and Wye voltages in a variety of surge current capacity ratings from 120kA to 400kA. Available in three configurations, the BSPD Series features and options make it easy to specify units for many electrical applications including service entrances, distribution switchboards, panelboards and point-of-use. All possible combinations of product attributes are available for ordering in the catalog number (see page 7). Features BSPD uses Bussmann series SurgePOD thermally protected Metal Oxide Varistor (MOV) technology to safely shunt overvoltages to ground while its thermal disconnect capability eliminates the need for additional fusing 200kA SCCR meets the highest NEC requirements Models available to meet the overvoltage protection needs of Wye and Delta electrical s from 208 to 600 volts, 3-phase BSPD has the highest nominal discharge current (I n ) of 20kA per UL 1449 4 th Edition. This rating indicates the SPD s ability to handle a number of large-magnitude surges over a short period of time and remain operational. 120kA to 400kA surge current capacity (I max ) ratings meet the needs of larger switchgear and power distribution panel applications Optional Form C contact relay, EMI/RFI filtering and surge counter available to meet additional requirements. 200kA Short-Circuit Current Rating (SCCR) NEMA 1 or NEMA 4 enclosures RoHS compliant 10 year warranty Factory sealed to improve electrical safety All BSPD Series units are factory-sealed to eliminate arc flash and shock hazards, as the user/installer has no chance of coming into contact with energized parts. The units also contain no userserviceable parts or wire lugs that require periodic retightening to eliminate the need for periodic maintenance. Bussmann SurgePOD technology eliminates the need for additional fusing BSPD uses Bussmann SurgePOD modules that each contain an internal element that safely disconnects upon reaching an overvoltage breakdown condition. Prewired All BSPD units are factory wired for ease of installation. Simply install any necessary conduit runs, mount the unit and make all wire connections. No need for internal wiring or access to the unit s inside. Compact size takes less space Available in enclosures that are up to 50% smaller than other products with comparable ratings the BSPD Series come in NEMA 1 and 4 enclosures that differ in size according to their surge current capacity (I max ). NEMA 1 BSPD Series units. The 120-200kA surge current capacity units are housed in a 74 square-inch enclosure that is only 3-1/2 inches deep. The 300-400kA surge current capacity units are housed in a 74 square-inch enclosure that is only 6 inches deep. NEMA 4 BSPD Series units. The 120-200kA surge current capacity units are housed in a 108 square-inch enclosure that is only 5-3/8 inches deep. The 300-400kA surge current capacity units are housed in a 108 square-inch enclosure that is only 7-11/16 inches deep. Agency information Basic, Standard and Standard with Surge Counter configurations UL Listed, 1449 4 th Edition, File E316410, Guide VZCA, CSA Certified, Notice 516, File 243397 Standard and Standard with Surge Counter configurations are also UL Recognized, 1283 5 th Edition, File E316410, Guide VZCA2, CSA Component Acceptance, Std. C22.2, No. 8-M1986, File 243397 BSPD Series unit mounted externally to a Bussmann Quik-Spec Coordination Panelboard 2

BSPD SPDs for overvoltage protection on Technical Data 10209 Enhanced protection status indicators Unlike many SPDs that only have single-color indicators, all BSPD units include green and red Light Emitting Diodes (LEDs) that indicate the true protection status for each phase. If power is removed from any one phase, the unit s LEDs continue to indicate the protection status on that phase regardless if power is applied to the phase. This feature ensures proper indication. Although many SPDs on the market have N-G surge protection, they do not always have a means of monitoring and indicating the protection status of that mode. All BSPD units for Wye s also contain green and red LED surge protection status indicators for the Neutral-to-Ground (N-G) connection. Like the phase protection status LEDs, the N-G protection status LEDs show the true protection status in the N-G mode. By specifying the BSPD Series, users are supplied with accurate information concerning the surge protection status of their electrical s. Configurations The BSPD Series provides users with three configurations. These are: Basic (UL Type 1 - can be installed in UL Type 2 locations) Standard (UL Type 2) Standard with Surge Counter (UL Type 2) The proper configuration can be selected based on application requirements or specification. Table 1. Configuration comparisons Dimensions - in (mm) and weights 12.05 (306.1) 0.78 (19.8) 5.24 (133.1) 2.00 (50.8) 3.48 (88.4) 4.41 (112.0) 10.48 (266.2) 0.68 (17.3) Ø0.20 (Ø5.1) Figure 1. NEMA 1, 120kA-200kA Units, Weight = 6.8 Lbs (3.1 kg) 7.28 (184.9) 5.27 (133.9) 7.47 (189.7) 5.47 (138.9) 1.00 (25.4) 11.25 (285.8) 0.40 (10.2) 1.00 (25.4) Feature Basic (Type 1) Configuration Standard (Type 2) Standard with Surge Counter (Type 2) 12.05 (306.1) 5.24 (133.1) 10.48 (266.2) 0.67 (17.0) 11.25 (285.8) Surge protection using thermally protected MOV technology Green and red LED protection status indicators for each phase Green and red LED protection status indicators for the Neutral-to-Ground protection mode (Wye s only) 0.78 (19.8) 2.00 (50.8) 5.76 (146.3) 6.69 (169.9) Ø0.20 (Ø5.1) Figure 2. NEMA 1, 300kA-400kA Units, Weight = 13.5 Lbs (6.1 kg) 7.47 (189.7) 0.40 (10.2) Audible alarm with silence button Form C relay contact EMI/RFI filtering, providing up to 50dB of noise attenuation from 10kHz to 100MHz Surge counter with reset button held in nonvolatile memory A B 120-200kA 2.60 (66.0) 5.39 (137.0) 250-400kA 4.10 (104.1) 7.68 (195.0) Figure 3. NEMA 4, 120kA-400kA Units, Weight = 120-200kA; 14.6 Lbs (6.6 kg), 250-400kA; 21.0 Lbs (9.5 kg) 3

BSPD SPDs for overvoltage protection on Voltage protection ratings ANSI/UL 1449 4 th Edition voltage protection ratings Voltage Protection Rating (V PR ) data for all units is included in the following tables, The data varies based upon the configuration and NEMA enclosure. V PR values for the Basic configurations are on the left-hand side of the page. Tables on the right-hand side contain VPR values for the Standard or Standard with Surge Counter configurations. NEMA 1: Basic (cat. nos. ending with 1K) Table 2. 120-200kA 208Y 700 700 700 1200 480Y 1200 1200 1200 2000 480D 2000 2500 NEMA 1: Standard or Standard w/ Surge Counter (cat. nos. ending with 2K or 3K) Table 5. 120-200kA 208Y 600 800 600 1000 480Y 1200 1200 1200 1800 480D 2500 2500 Table 3. 300kA 208Y 700 700 700 1000 480Y 1200 1200 1200 1800 Table 6. 300kA 208Y 600 700 600 1000 480Y 1000 1200 1000 1800 Table 4. 400kA 208Y 700 700 700 1000 480Y 1200 1200 1200 1800 Table 7. 400kA 208Y 600 700 600 1000 480Y 1000 1200 1000 1800 4

BSPD SPDs for overvoltage protection on Technical Data 10209 NEMA 4: Basic (cat. nos ending with 1P) Table 8 120 200kA 208Y 700 800 700 1200 480Y 1200 1200 1000 2000 480D 2000 2500 NEMA 4: Standard or Standard w/ Surge Counter (cat. nos. ending with 2P or 3P) Table 11. 120 200kA 208Y 900 900 700 1500 480Y 1200 1200 1000 2500 480D 2500 2500 Table 9. 300kA 208Y 700 800 700 1200 480Y 1200 1200 1200 2000 Table 12. 300kA 208Y 800 900 700 1500 480Y 1200 1200 1000 2000 480D 2000 2000 Table 10. 400kA 208Y 700 800 700 1200 480Y 1200 1200 1200 2000 Table 13. 400kA 208Y 800 900 700 1500 480Y 1200 1200 1000 2000 480D 2000 2000 5

BSPD SPDs for overvoltage protection on 5.0 Specifications Table 14. Specifications Description Available voltages Specification Three-phase Wye 120/208, 277/480 and 347/600 Three-phase Delta 240, 480 and 600 Input power frequency Maximum Continuous Operating Voltage (MCOV) 50/60Hz 208Y, and 240D voltage/ type s 150 L-N,150 L-G, 150 N-G, 300 L-L 480Y type 600Y type 480D type 600D type Short-Circuit Current Rating (SCCR) Nominal discharge current (I n ) Surge current capacity per phase (I max ) SPD Types Enclosure types Ports 1 SPD Conductor length/gauge 320 L-N, 320 L-G, 320 N-G, 640 L-L 420 L-N, 420 L-G, 420 N-G, 840 L-L 640 L-G, 640 L-L 840 L-G, 840 L-L 200kA 20kA 120kA, 200kA, 300kA and 400kA ratings available Type 1 (Basic configuration, can also be used in Type 2 applications) Type 2 (Standard and Standard With Surge Counter configurations) NEMA 1, NEMA 4 304 Stainless Steel 48 (1.22m) 10AWG Stranded copper Form C contact relay (Standard and Standard With Surge Counter configurations only) Contact ratings Lead length/gauge Contact logic Power consumption Basic configuration 208Y and 240D voltage/ type s 0.5W 480Y and 480D voltage/ type s 1.1W 600Y and 600D voltage/ type s 1.3W Standard and Standard with Surge Counter configurations 208Y and 240D voltage/ type s 0.6W 480Y, and 480D voltage/ type s 1.7W 600Y and 600D voltage/ type s 2.1W s Operating temperature / humidity 150Vac or 125Vdc, 1A maximum 48 inches (1.22m) / 14AWG Operating altitude - ft (m) 16,000 (5000) EMI/RFI filtering attenuation Weight - lbs (kg) Agency information Power ON, normal state; N.O. contact = OPEN, N.C. contact = CLOSED Power OFF, fault state; N.O. contact = CLOSED, N.C. contact = OPEN Three-phase Delta; L-G, L-L Three-phase Wye; L-N, L-G, N-G, L-L -40 to +50 C (-40 to +122 F) / 5% to 95%, non-condensing Up to 50dB from 10kHz to 100MHz (Standard and Standard With Surge Counter configurations) NEMA 1: 120kA-200kA - 6.8 (3.1), 30-400kA -13.5 (6.1) NEMA 4: 120-200kA - 14.6 (6.6), 300-400kA - 21.0 (9.5) - Basic, Standard and Standard with Surge Counter configurations UL Listed 1449 3rd Edition File E316410 Guide VZCA, CSA Certified Notice 516 File 243397 - Standard and Standard with Surge Counter configurations are also UL Recognized 1283 5th Edition File E316410 Guide VZCA2, CSA Component Acceptance Std. C22.2 No. 8-M1986 File 243397 Seismic withstand capability Meets or exceeds the requirements specific to I.B.C. 2006, C.B.C 2007 and U.B.C Zone 4 Warranty 10 Years (see warranty statement 3A1502 for details at www.cooperbussmann.com/surge) 6

BSPD SPDs for overvoltage protection on Technical Data 10209 6.0 Catalog Number System Table 15. BSPD part number All possible combinations of the BSPD attributes are available for ordering. BSPD 200 480D 2 K Series BSPD Enclosure rating K = NEMA 1 P = NEMA 4 ka Rating per phase 120kA 200kA 300kA 400kA type 208Y = 120/208 Wye (4W + G) 480Y = 277/480 Wye (4W + G) 600Y = 347/600 Wye (4W + G) 240D = 240 Delta (3W + G) 480D = 480 Delta (3W + G) 600D = 600 Delta (3W + G) Configurations 1 = Basic Green and red LEDs per phase to indicate protection status Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode 2 = Standard Green and red LEDs per phase to indicate protection status Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode Audible alarm with Silence button Form C contact relay. See Table 3, Specifications EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz 3 = Standard With Surge Counter Green and red LEDs per phase to indicate protection status Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode Audible alarm with silence button Form C contact relay EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz Surge counter with reset button Technical support information If you have any questions or need additional information, please contact the Eaton s Bussmann Business Application Engineers between the hours of 7:00 a.m. and 5:00 p.m. Central Time at 855-287-7626 (855-Bussmann) or by e-mailing FuseTech@Eaton.com. 7

BSPD SPDs for overvoltage protection on The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States 2017 Eaton All Rights Reserved Printed in USA Publication No. 10209 BU-SB14678 April 2017 Eaton and Bussmann are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton s Bussmann series product information, call 1-855-287-7626 or visit: Follow us on social media to get the latest product and support information.