REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Similar documents
REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

Feeder/ Motor Protection Relay VAMP 40

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ABL8WPS24200 regulated SMPS - 3-phase V AC - 24 V - 20 A

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ABL8RPS24030 regulated SMPS - 1 or 2-phase V - 24 V - 3 A

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

Protection relays.

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

2018 Catalog. Easergy P3. Network Protection Relays

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

GE Multilin 350 Feeder Protection Relay Specifications

TM3AI4 module TM3-4 analog inputs

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

TM241C40R controller M IO relay

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

BMXCPS3020H power supply module X V isolated DC -

TM3DI16 module TM3-16 inputs

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

TM3TI4 module TM3-4 inputs temperature

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

TM3TI8T module TM3-8 inputs temperature

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

TM241CE40R controller M IO relay Ethernet

TM241C24T controller M IO transistor PNP

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

TM241C40U controller M IO transistor NPN

RM35TF V AC

VAMP 57. Multipurpose feeder and motor protection relay. m.vamp.fi

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

SACE Emax 2 Specification guide

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

ATV930U07M3 variable speed drive - ATV930-0,75kW - 200/240V- with braking unit - IP21

TM3TM3 module TM3-2 temperature inputs and 1 analog output

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

TM221CE40R controller M IO relay Ethernet

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

TM241CE24U controller M IO transistor NPN Ethernet

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

ATV650D22N4 variable speed drive ATV650-22kW/30HP V - IP55

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

TM200CE24T controller M IO transistor Source+ Ethernet

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

ATV630D11N4 variable speed drive ATV630-11kW/15HP V - IP21/UL type 1

XBTGT2220 advanced touchscreen panel x 240 pixels QVGA - 5.7" - 24 V

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RM4TR31 three-phase network control relay RM4-T - range V

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

TM221M16TG controller M IO transistor PNP spring

TM241CE40R controller M IO relay Ethernet

TM221M32TK controller M IO transistor PNP

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

BMXAMI0410 analog input module M340-4 inputs - high speed

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

Transcription:

Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, RS-485 Main Range of product Product or component type Relay application Device short name [Us] rated supply voltage Type of measurement Input current Input type Number of sensors Analogue input number Analogue output number Number of inputs 16 Operating threshold Mar 31, 2018 Easergy P3 Protection relay Universal P3U30-5AAA3BBA 48...230 V AC/DC Current and voltage 1 current input CT...1/5 A 3 current input CT...1/5 A for phase current 4 voltage input VT for voltage 12 temperature sensor(s) on external module 4 external module 4 external module 220...230 V AC/DC Number of outputs 8 1 watchdog Transmission support medium Integrated connection type Protection type Copper cable external module Fiber optic cable external module Front: USB port with 1 connector Rear: RS485 with 1 connector Cold load pick-up Switch ON to fault (SOTF) Phase overcurrent ANSI:50/51 Directional phase overcurrent ANSI:67 Earth fault overcurrent ANSI:50N/51N Directional earth fault ANSI:67N Transient earth fault ANSI:67NI Capacitor bank unbalance ANSI:2 Broken conductor ANSI:46 I2/I1 Breaker failure ANSI:50BF Directional active underpower ANSI:37P Recloser ANSI:79 Phase undercurrent ANSI:37 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Single line diagram Control and monitoring type Monitoring function Network and machine diagnosis type Control type Number of devices 6 Switchgear diagnosis type Type of measurement Communication port protocol Excessive starting time, locked rotor ANSI:48/51LR Motor restart inhibition ANSI:66 Capacitor overvoltage ANSI:59C Negative sequence overcurrent ANSI:46 Overvoltage ANSI:59 Undervoltage ANSI:27 Positive sequence undervoltage ANSI:27P Earth fault overvoltage ANSI:59N Underfrequency ANSI:81/81N Rate of change of frequency ANSI:81R Synchro-check ANSI:25 Lockout relay ANSI:86 Thermal overload protection ANSI:49 Temperature monitoring ANSI:38/49T H2 detection H5 detection Programmable stages ANSI:99 Programmable curve 6 controlled + 2 monitored objects 8 programmable stages Trip circuit supervision ANSI:74 Circuit breaker monitoring Relay self-monitoring Tripping context Event recording Disturbance recording Fault locator 21FL Local control on single-line diagram Local control with I/O keys Local/Remote control 2 function keys Custom logic (logic equations) Mobile application Web-server Programmable switchgear interlocking Switchgear CT supervision CT/VT supervision ANSI:60 Trip circuit supervision ANSI:TCS Reactive energy Short circuit fault reactance Earth fault reactance RMS active power RMS reactive power RMS apparent power Cos φ Tan φ Power angle Voltage interruption Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Voltage phase to earth Voltage phase to phase Voltage zero sequence Voltage positive sequence Voltage negative sequence Voltage ratio of negative and positive Current 2nd, 15th harmonics with THD Voltage 2nd, 15th harmonics with THD Phasor diagram of currents or voltages Condition monitoring CB wear Frequency Active power Power factor Active energy Reactive power Apparent power DNP3 2

Modbus RTU IEC 60870-5-101 IEC 60870-5-103 DeviceNet Profibus DP SPAbus Complementary Setting 4 Cybersecurity Local signalling Display resolution Display type Software name Connections - terminals Password protection Port hardening 8 LEDs programmable 4 LEDs 128 x 64 pixels LCD Easergy SmartApp ESetup Easergy Pro virtual simulation test Screw removable Environment IP degree of protection IP54 conforming to IEC 60529 Operating altitude 2000 m Protective treatment Conformal coating Standards IEC Ambient air temperature for operation -40...60 C Ambient air temperature for storage -40...70 C Relative humidity 0...95 % without condensation Height 169.5 mm Width 170 mm Depth 205 mm Product weight 3.5 kg maximum Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1741 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Product environmental Available End of life manual 3

Connections and Schema Functional View 4

Dimensions Drawings Base Unit Dimensions A B With screw connector 214 mm/8.43 192 mm/7.6 With ring-lug connector 226 mm/8.90 204 mm/8.0 5