RM5G Series Simple Version Operation Manual

Similar documents
Firmware Manual - EC Series Drives

VARIABLE FREQUENCY DRIVE. Operation Manual. RM6E1 series

VS mini J7 to J1000 Replacement Instructions

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

GV3000/SE AC Drive Quick Reference Version 6.06

Optidrive Applications Support Library

QUICK REFERENCE GUIDE

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

RoBoox AC Drive E100/E102 Series KW to 18.5KW E180 Series KW to 630KW

VFA7/VFP7 Parameter List (Ver315)

EQ5 SERIES Quick Start Guide for Constant Torque Applications

Quick Start Guide For GVX9000 AF Drives

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Step 1: Choose the Appropriate CPU Step 2: Make the Connections

Altivar 21 Programming and Operation Guide

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

8000m Series Compact Inverter User Manual

Tongta Inverter TDS-F8

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Optidrive Applications Support Library

INSTALLATION AND OPERATION MANUAL KBDF SERIES

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

Power Connections: Basic Wiring:

PowerFlex 400 AC Drive Guide Specification

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

Unidrive M400 (Frame 1 to 4) Quick Start Guide

INSTALLATION AND OPERATION MANUAL KBMK SERIES. Adjustable Frequency Drives for 1/8 HP thru 1 HP 3-Phase AC Motors Rated VAC, 50/60 Hz

Motor Controllers Variable Frequency AC Drives Type VariFlex 2 RVCF

SV9000 AF DRIVES SVReady User Manual. Pump and Fan Control Application

Easy To Use OEMS Take Note

User Manual. RS485 Option Board for SV-iS5/iH Series. LG Industrial Systems

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

SENSORLESS VECTOR CONTROL

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

MC Series Drives. Flexible, simple, rugged, robust!

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

PowerFlex 40 Sample Specification

CONTENTS. Contents. E5 Series Universal Variable Speed Drive Catalog. Product Introduction

Safety Instruction. This symbol indicates the possibility of injury or damage to property.

Specification Number: Product Name: FRENIC-Mega AC Drives for General Purpose Applications (½ - 150Hp at 230V and ½ Hp at 460V)

1336 PLUS II Quick Start Guide

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

SMVector Additional I/O Module Installation and Operation Manual

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

A drive dedicated to variable speed control for HVAC applications

Display / Adjustment Options VW3-A16101, VW3-A16102, VW3-A16103

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Inverter (VFD) Manual

Y07/1-01(V1.0) Goodrive20 Series Vector Control Inverter

3GV M Modbus RTU Register Map

Features and Benefits

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

Frequency Inverters. WJ200 Series. Compact Inverter. WJ200 Series

1. Introduction About the Vacon 5X drive Identifying the drive by model number Drive model numbers...7

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

F510 Fan & Pump AC Drive

E2 Modbus RTU Register Map

For additional PowerFlex 4M data and general drive information, refer to the following publications:

VS1MX AC Extreme Duty Microdrive

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Frequency Inverters WJ200 Series Compact Inverter

Installation, Operation and Maintenance Manual

Zenith DS9000 Dispensing System

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

WARNING UNINTENDED EQUIPMENT OPERATION

Instruction Manual. P3S2INST-01A February 2008 Part Number: R1 Copyright 2008 Electromotive Systems

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Installation & Operation Manual KBVF SERIES. Chassis / IP-20 AC Drives

AC Tech. Variable Speed AC Motor Drives. SCN Series Installation and Operation Manual

Mini Design Inverter. For applications which need tiny installation space. HNC Electric Limited

smd - frequency inverter 0.25 kw 4.0 kw

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive

Q9 ASD LOW VOLTAGE DRIVE

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

PowerFlex 700H Sample Specification

High-Performance Sensorless Vector Control Inverter User Manual

A510 Heavy Duty AC Drive

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

Table of Contents 1. Overview Installation...6

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Orientation F7 Drive Software Technical Manual

vacon nx ac drives brake chopper unit (bcu) application user s manual

DriveWare. User s Guide DriveConfig

SP500 AC Drive Installation and Operation Manual Version 3.1

Control Mode Application and Selection Guide

1-1 AC DRIVE OVERVIEW EXERCISE OBJECTIVE

AF-60 LP TM Micro Drive. Programming Guide

Transcription:

Grounding Power and Braking Motor Power Source RM5G Series Simple Version Operation Manual http://www.rhymebus.com.tw 2014.10.23 Edition Thank you for using RHYMEBUS RM5G series drive. For proper operations and safety purposes, please read complete manual carefully (enclose CD inside the box) or visit RHYMEBUS website: http://www.rhymebus.com.tw to download the operation manual. To prevent any possible dangers,only the qualified personnel may proceed with the installation. Please pay attention to the safety precautions marked with DANGER or CAUTION in complete manual before installation. DANGER CAUTION User may cause the casualty or serious damages if user does not abide by the instructions of the manual to execute the tasks. User may cause injuries to the people or damage the equipment if user does not abide by the instructions of the manual to execute the tasks. Terminals of Main Circuit R,S (L,N) Single-phase; sinusoidal power source input terminals. AC power source R,S,T input terminals Three-phase; sinusoidal power source input terminals. (L1,L2,L3) + U,V,W (T1,T2,T3) P(+), N - P +, N - P, N P, PR P(+), PR P +, PR P(+), P1 P +, P1 DC power source input terminals Drive outputs to motor terminals Dynamic brake unit terminal External brakingresistor terminal External reactor terminal External DC power source terminal. Only 2007 ~ 2015, 4007 ~ 4020 models have the terminal. Output three-phase variable frequency and voltage to motor. The terminalscan connect to dynamic braking unit(option). The terminals can connect to external brake resistor (option). The terminal can connect to DC reactor (DCL) for improving power factor. The default setting is connected by a jumper. PE(or G) Grounding terminal Ground the drive in compliance with the NEC standard or local electrical code. 1

Model: RM5G-1001/2-1PH~RM5G-1002-1PH ; RM5G-2001/2-1PH~RM5G-2002-1PH Model: RM5G-2001/2~RM5G-2005 ; RM5G-4001~RM5G-4005 RM5P-2001~RM5P-2005; RM5P-4002~RM5P-4007 2: Braking Resistor(option) Single-Phase connect to, terminal. Three-Phase connect to,, terminal. G PR P N Induction Motor RM5G U/T1 V/T2 IM W/T3 G Model: RM5G-2007 ~ RM5G-2015; RM5P-2010 ~ RM5P-2020; Model: RM5G-4007 ~ RM5G-4025; RM5P-4010 ~ RM5P-4030 Three-Phase, 50/60Hz AC Power Input 2:Braking Resistor (option) PR P(+) 1:DC Reactor(DCL; option) P1 RM5G/P Jumper N U/T1 V/T2 W/T3 Induction Motor IM Model: RM5G-2020 ~ RM5G-2040;RM5P-2025 ~ RM5P-2050; Model: RM5G-4030 ~ RM5G-4060; RM5P-4040 ~ RM5P-4075 1:DC Reactor(DCL; option) Jumper Three-Phase, 50/60Hz AC Power Input P(+) P1 RM5G/P N U/T1 V/T2 W/T3 Induction Motor IM Model(B Type): RM5G-2020B ~ RM5G-2040B;RM5P-2025B ~ RM5P-2050B; Model(B Type): RM5G-4030B ~ RM5G-4060B; RM5P-4040B ~ RM5P-4075B Three-Phase 50/60Hz AC Power Input 2:Braking Resistor(option) PR 1: DC Reactor(DCL; option) P(+) P1 RM5G/P Jumper N U/T1 V/T2 W/T3 Induction Motor IM 2

Model: RM5G-2050 ~ RM5G-2075;RM5P-2060 ~ RM5P-2100; Model: RM5G-4075 ; RM5P-4100 1:DC reactor(dcl; option) Jumper Three-Phase, 50/60Hz AC Power Input P(+) P1 RM5G/P N U/T1 V/T2 W/T3 Induction Motor IM Model(B Type): RM5G-2050B ~ RM5G-2075B; Model(B Type): RM5G-4075B;RM5P-4125B 2:Braking Resistor(option) Three-Phase, 50/60Hz AC Power Input PR P RM5G/P N U/T1 V/T2 W/T3 Induction Motor IM Model: RM5G-2100~RM5G2250; RM5P-2125~RM5P-2250 Model: RM5G-4100~RM5G-4600; RM5P-4125~RM5P-4700 1 DCL 1 ACL Jumper P + P1 NӨ Induction Motor Three-Phase, 50/60Hz AC Power Input RM5G/P U/T1 V/T2 W/T3 IM PE PE 1.RM5G-100HP/RM5P-125HP above drives: AC reactor (ACL) is the standard accessory; RM5G-175HP/RM5P-200HP above drives: DC reactor (DCL) is the standard accessory. Please remove the jumper between P1 and P terminal, when connecting the external DC reactor (DCL). Do Not remove the jumper, when DC reactor (DCL) does not be connected. 2.PR terminal is suitable for braking resistor and B Type Series of RM5G is optional (Example: RM5G-2020B, include braking resistor) 3

Output terminals Control circuit terminal Input terminals Control power Control Termianl Type Symbol Function Description P12/12V GND FWD REV X1 X2 X3 X4 X5 X6 Power terminal; Control Output DC+12V; Maximum supplied current is 20mA. device usage Common of analog input Common of power terminals(p12/12v) and analog input control terminals control terminals (Vin, Iin). Forward command Connect the FWD and COM terminals for forward terminal operation. (F_001=0,1,2) Reverse command Connect the REV and COM terminals for reverse operation. terminal (F_001=0,1,2) Connect the X1 and COM terminals and set the function input F_052. terminal 1 Default setting: Multi-speed level 1 command input terminal 2 input terminal 3 input terminal 4 input terminal 5 input terminal 6 COM Common of digital input controlterminals Vin Analog input terminal Input range: DC 0~10V Iin FM+ AM+ M- Ta1 Tb1 Tc1 Ta2 Analog input terminal Analog output terminals Common of analog output terminals output terminals (relay type) Connect the X2 and COM terminals and set the function F_053. Default setting: Multi-speed level 2 command Connect the X3 and COM terminals and set the function F_054. Default setting: Jog command Connect the X4 and COM terminals and set the function F_055. Default setting: Secondary accel/decel time command Connect the X5 and COM terminals and set the function F_056. Default setting: External fault command (thr) Connect the X6 and COM terminals and set the function F_057. Default setting: Reset command Common of digital input control signal terminals. (FWD, REV and X1 ~ X6) Input signal selection SW1: I position (current signal) SW1: V position (voltage signal) Input range: DC 4~20mA (2~10V) or DC 0~20mA (0~10V) The function is set by F_126. Voltage meterwith 10V full scale spec. (meter impedance: 10kΩ above) Maximum output current: 1mA Common of analog output terminals. N.O (contact a); The function is set by F_060 (default setting: Error detection). Capacity: AC250V, 0.5AMax, cosθ=0.3 N.C (contact b); The function is set by F_060 (default setting: Error detection). Capacity: AC250V, 0.5AMax, cosθ=0.3 Common terminal for Ta1, Tb1. N.O (contact a); The function is set by F_131 (default setting: Operation detection). Capacity: AC250V, 0.5AMax, cosθ=0.3 Common terminal for Ta2. The function is set by F_058, F_059. Capacity: DC48V, 50mAMax Tc2 Y1 output Y2 terminals CME (open collector type) Common terminal of Y1, Y2. 4

Description of Terminal and Wiring Diagram Shielded Wire Twisted-Pair P Shielded Wire RM5G Forward Reverse Input Terminal 1 Input Terminal 2 Input Terminal 3 Input Terminal 4 Input Terminal 5 Input Terminal 6 VR 1KΩ,1/4W Analog Input Setting (Default: DC 0~10V) P P P FWD 1 REV X1 X2 X3 SINK X4 SW2 X5 X6 SOURCE COM 12V Vin I Iin SW1 V GND 2 AM+ FM+ GND Ta2 Tc2 Output Terminal (Relay Type) Ta1 (AC 250V/0.5A COSθ=0.3) Tb1 Tc1 Y1 Y2 CME (+) (+) (-) Analog Output Terminal (DC 0~10V) Output Terminal (Open collector) (DC 48V/50mA) Analog Input Setting (Default: DC 4~20mA) 1.SW2: Voltage SINK / SOURCE selection; Board of Cooling Fan The input signal mode selection of multi-function input terminal(x1~x6), FWD/REV terminals. 2.SW1: I / V selection; I position: Iin-GND terminal is inputted with thecurrent signal.(default) V position:iin-gnd terminal is inputted with the voltage signal. 3.The analog input selection is set by F_126 (default: DC 2~10V(4~20mA)) Voltage Board of Cooling Fan RM5G-4075 / RM5P-4100 above models have the voltage selection board shown in above figure when removing the main circuit terminal cover of the drive. Please carefully select the jumper position according to the power source(actual power voltage level) to avoid the burnout of the fan or the overheating of the drive.(ex: When the power source is 460V, selecting the position from 380V to 460V) 5

Digital Type Keypad (KP-201C) for RM5G/P 1. ON: Primary frequency command is set by keypad or UP/DOWN terminal 2. OFF: Primary frequency command is set by multi-function input terminals 1. T.S: Indicate the status of terminals 2. Unit indicator Blinking: Under acceleration or deceleration ON: Constant speed OFF: Stop Drive start key 1. Enter function setting mode 2. Back to monitor mode Up/down key of changing functions and parameters 1. Enter parameter setting mode 2. Back to function setting mode 3. Switch monitor mode 1. Drive stops(cut off output frequency of drive) 2. Fault reset Operation of Keypad The operation of the digital keypad includes fault messages and three modes. The switching methods are shown as below figure: Monitor mode Function setting mode Parameter setting mode PROG PROG STOP RESET PROG Fault message *When the keypad is idle for three minutes at function setting mode or parameter setting mode, drive will switch back to the main display. The operation steps are shown as below table (by default setting) Operation Steps 1.Start the drive and enter the monitor mode. 2.Press PROG key and enter the function setting mode. Display 3.Press key and enter the parameter setting mode. 4.Press key and return to the function setting mode. 5.Press PROG key and return to the monitor mode. 6

Description of Monitor Mode There are eight displays can be selected in the monitor mode. Press to switch the display in accordance with below sequence under monitor mode. User can determine one of eight displays as the main display from function F_006 ( of Main Display). Please refer to the following illustrations: Enter monitor mode Display 1 (Output ) Display 2 ( Command) Display 3 (Output Voltage) Display 8 (Terminal Status) Monitor Mode Display 4 (DC Bus Voltage) Display 7 (Machine Speed(MPM)) Display 6 (Motor Speed(RPM)) Display 5 (Output Current) a. Select one of eight displays as the main display from function F_006 ( of Main Display). b. Determine one of eight displays as the main display according to the application. When the parameter of function is completed without pressing key, the drive will automatically switch back to the main display after 3 minute. 7

Parameter List Func. Name Description F_000 Drive Information F_001 F_002 F_003 F_004 F_005 F_006 F_007 F_008 Start Command Primary Command of STOP Key Validity Command of Command Auto-Storing of Main Display Machine Speed Ratio Digits of Decimal Value (Machine Speed) 0: Software version1: Drive model number 2: Drive running hours 3: Drive supply power time 4: Software checksum code 5: Reserved Start command Rotation direction command 0: FWD or REV terminal FWD or REV terminal 1: FWD terminal REV terminal 2: FWD, REV terminal 3: Keypad RUN key Forward direction 4: Reverse direction 0: command by analog signal via terminal. 1: command by keypad. 2: Motor speed (RPM) command by keypad. 3: Machine speed (MPM) command by keypad. 4: command by UP/DOWN terminal. 0: Start command by terminal, STOP key disabled. 1: Start command by terminal, STOP key enabled. 0: In the monitor mode, frequency command cannot be changed. 1: In the monitor mode, frequency command is changeable. 0: In the monitor mode, frequency command auto-storing disable. 1: In the monitor mode, frequency command auto-storing after 3 minutes. 8 Range of Setting Unit Default 0~4 3 0~4 1 0,1 1 0,1 1 0,1 1 Select 1 of 8 monitor modes as the main display. 1~8 1 Set the ratio of machine speed. This function determines MPM display value. Select the digits of decimal values displaying the machine speed. 0.00~ 500.00 0.01 20.00 0~3 0 Multi-speed Multi-speed Multi-speed Jog speed level 3 level 2 level 1 50.00 F_009 Primary Speed command (Note1) command command command OFF OFF OFF OFF 60.00 (Note2) F_010 Preset Speed 1 OFF OFF OFF ON 10.00 F_011 Preset Speed 2 OFF OFF ON OFF 0.00~ 0.01 20.00 F_012 Preset Speed 3 OFF OFF ON ON 400.00 Hz 30.00 F_013 Preset Speed 4 OFF ON OFF OFF 0.00 F_014 Preset Speed 5 OFF ON OFF ON 0.00 F_015 Preset Speed 6 OFF ON ON OFF 0.00 F_016 Preset Speed 7 OFF ON ON ON 0.00 F_017 Jog Speed ON X X X 6.00 F_018 Reference of The frequency corresponding to accel/decel time. Accel/Decel Time 0.01~ 400.00 0.01 Hz 50.00 (Note1) 60.00 (Note2)

Range of Func. Name Description Setting Primary The acceleration time of primary speed, preset speed F_019 Acceleration Time 4~7, and jog speed. Primary The deceleration time of primary speed, preset speed F_020 Deceleration Time 4~7, and jog speed. Acceleration Time F_021 Acceleration time of preset speed 1. of Preset Speed 1 Deceleration Time F_022 Deceleration time of preset speed 1. of Preset Speed 1 Acceleration Time F_023 Acceleration time of preset speed 2. of Preset Speed 2 0.0~ Deceleration Time F_024 Deceleration time of preset speed 2. 3200.0 of Preset Speed 2 Acceleration Time F_025 Acceleration time of preset speed 3. of Preset Speed 3 Deceleration Time F_026 Deceleration time of preset speed 3. of Preset Speed 3 Secondary Switch to ondary acceleration time by F_027 Acceleration Time multi-function input terminal. Secondary Switch to ondary deceleration time by F_028 Deceleration Time multi-function input terminal. Set S-curve for Set S-curve to slow the acceleration and deceleration F_029 0.0~5.0 Accel/Decel Time time at start and stop. F_030 Limitation of 0: Output voltage of V/F pattern is not limited. Output Voltage 1: Output voltage of V/F pattern is limited. F_031 F_032 Maximum Output Starting Maximum output frequency of drive. 9 Unit Default 15.0 (Note5) 0.0 0, 1 0 ~400.0 Hz 50.0 (Note1) 60.0 (Note2) Starting frequency of drive s output. ~10.0 Hz 0.5 F_033 The voltage corresponds to the output starting ~50.0 8.0 (Note3) Starting Voltage V frequency. 12.0 ~100.0 (Note4) 50.0 F_034 The frequency corresponds to the base voltage in (Note1) Base ~400.0 Hz V/F pattern. 60.0 (Note2) F_035 Base Voltage 220.0 The voltage corresponds to the base frequency in ~255.0 (Note3) V V/F pattern. 380.0 ~510.0 (Note4) F_036 V/F 1 at the first point of V/F pattern. 0.0~399.9 Hz 0.0 0.0~255.0 F_037 V/F Voltage 1 Voltage at the first point of V/F pattern. V 0.0~510.0 0.0 F_038 V/F 2 at the ond point of V/F pattern. 0.0~399.9 Hz 0.0 F_039 V/F Voltage 2 Voltage at the ond point of V/F pattern. 0.0~255.0 V 0.0 0.0~510.0 F_040 Vin Gain Analog input Vin gain ratio adjustment. 0.00~2.00 0.01 1.00 F_041 Vin Bias Analog input Vin bias ratio adjustment. F_042 F_043 Upper Limit Lower Limit The upper limit of output frequency= F_031(Maximum Output )*F_042-1.00~ 1.00 0.01 0.00 0.00~1.00 0.01 1.00 The lower limit of output frequency= F_031(Maximum 0.00~1.00 0.01 0.00 Output )*F_043

Func. Name Description F_044 F_045 F_046 F_047 F_048 F_049 F_050 F_051 F_052 F_053 F_054 F_055 F_056 F_057 Analog Output Signal (FM+) Analog Output Gain(FM+) Motor Overload Protection (OL) Filter Setting of Analog Input Signal Motor Rated Current Motor No-Load Current Motor Slip Compensation Number of Motor Poles Input Terminal (X1) Input Terminal (X2) Input Terminal (X3) Input Terminal (X4) Input Terminal (X5) Input Terminal (X6) 0: Output frequency 1: command 2: Output current 3: Vin analog input signal. 4: Iin analog input signal. 5: DC bus voltage. 6. Output voltage. Range of Setting Unit Default 0~6 0 Analog output gain ratioadjustment. 0.00~2.00 0.01 1.00 1: Overload protection for dependent cooling fan type motor:enabled(ol) 2: Overload protection for independentcooling fan type motor: Enabled(OL) Filter the analog input signal when the frequency command is controlled by analog input terminal. (F_002=0). 10%~150% of drive Set the value according to the motor rated current. rated current Current setting according to the motor s no-load condition. According to the load condition, set the motor slip compensation for motor running at constant speed. (0.0: off) 0~2 1 0~255 20 0~motor rated current A A According to the rated current of motor 1/3 motor rated current -9.9~10.0 Hz 0.0 Determinate the RPM display value of monitor mode. 2~10 2P 4P =0: UP/DOWN frequency command enter key =0: DC braking enable ±1: Jog command ±2: Secondary accel/decel time command ±3: Multi-speed level 1 command (at stop) 4 ±4: Multi-speed level 2 command =0: ±5: Multi-speed level 3 Current limit enable command ±6: Reset command 1 ±7: External fault =0: command(thr) of primary or ±8: Interruption of output ondary frequency command(bb) -16~ +16 command ±9: Coast to stop (Note 7) 2 (ON: ondary frequency command(fr) command) ±10: Speed tracing from the =0: maximumfrequency Stop command with 3-wire ±11: Speed tracing from start/stop circuit the setting (N.O; contact a) =0: frequency ±12: Holding command ±13: UP command ±14: DOWN command 7 Stop command with 3-wire ±15: Clear UP/DOWN start/stop circuit frequencycommand (N.C; contact b) ±16: Analog input source 6 selection 3 10

Func. Name Description F_058 F_059 F_060 F_061 F_062 F_063 F_064 Output Terminal (Y1) Output Terminal (Y2) Output Terminal (Ta1,Tb1) ±1: Operation command detection ±2: Constant speed detection ±3: Zero speed detection ±4: detection ±5: Overload detection(olo) ±6: Stall prevention detection ±7: Low voltage detection(le) ±8: Braking detection ±9: Restart after instantaneous power failure detection ±10: Restart after error condition detection ±11: Error detection 11 Range of Setting -11 ~+11 (Note 7) Unit Default Constant Speed Set the bandwidth of constant speed detection range. 0.0~10.0 Hz Detection Range 2.0 Set the bandwidth of frequency detection range. Detection Range 0.0~10.0 Hz 2.0 Set the frequency detection level of multi-function Detection Level output terminal. 0.0~400.0 Hz 0.0 Automatic Torque According to the load condition, adjust the output Compensation voltage of the V/F pattern. (0.0: off) Range 0.0~25.5 1.0 System Overload F_065 Detection (OLO) 1: Enable System Overload 0: Detection during constant speedonly F_066 Detecting 1: Detection during operation only 0: Drive keeps operation when the overload is Output Setting detected F_067 after System 1: Drive trips to protection when the overload Overload isdetected F_068 F_069 F_070 F_071 F_072 F_073 F_074 System Overload Detection Level System Overload Detection Time Stall Prevention Level at Acceleration When the output current of drive is larger than the levelwith the duration of F_069, the drive will trip to protection. When the output current of drive is larger than the level (F_068 * drive s rated current) with the duration, the drive will trip to protection. If stall is occurred during acceleration, the motor keeps running at constant speed. (200%: off) Stall Prevention While the stall is occurred during constant speed Level at Constant running condition, the prevention of stall is to Speed decrease the speed of motor.(200%: off) Acceleration Time Setting after Stall Prevention under Constant Speed Deceleration Time Setting for Stall Prevention under Constant Speed Stall Prevention Setting at Deceleration Set the acceleration time after stall prevention under the constant speed. Set the deceleration time at the stallprevention under the constant speed. 1: Enable F_075 DC Braking Level Set the current level of DC braking. 3 2 11 0,1 0 0,1 0 0,1 0 30%~200% of drive rated current ~10.0 30%~200% of drive rated current 30%~200% of drive rated current ~ 3200.0 ~ 3200.0 1% 160 1% 170 1% 160 15.0 (Note5) 15.0 (Note5) 0, 1 1 0~150% of drive rated current 1% 50

Range of Func. Name Description Unit Setting Time of DC F_076 Braking after Stop Set the time for DC braking after drive stopped. 0.0~20.0 F_077 F_078 F_079 F_080 F_081 F_082 F_083 Time of DC Braking before Start Operation at Instantane- ous Power Failure Set the time for DC braking before drive started. 0.0~20.0 0: Drive cannot be restarted 1: Drive can be restarted 2: Ramp to stop 3: Drive will re-accelerate again during ramp to stop interval, when the power is restored. Voltage Level of Ramp to Stop by Set the voltage of power source for ramp to stop. Power Failure When the auto-restart times of error conditions Auto-restart Times (OC,OE,GF only) reach the setting value, the drive Setting of Error must be restarted manually. Trip Switching Stop Mode Reverse Prohibition 0: disable The setting value is higher and the motor noise is lower. 0: Ramp to stop 1: Coast to stop 2: Coast to stop+ DC braking 0: Reverse rotation allowed. 1: Reverse rotation NOT allowed. 12 Default 0.5 0.0 0~3 0 150.0~ 192.0 300.0~ 384.0 V 175.0 (Note3) 320.0 (Note4) 0~16 1 0 0~6 1 (Note6) 0~2 0 0, 1 0 F_084 Jump 1 Avoid mechanical resonance point 1. 0.0~400.0 Hz 0.0 F_085 Jump 2 Avoid mechanical resonance point 2. 0.0~400.0 Hz 0.0 F_086 Jump 3 Avoid mechanical resonance point 3. 0.0~400.0 Hz 0.0 F_087 F_088 F_089 F_090 F_092 Jump Range Set the range of the jump frequency 1, 2, 3. 0.0~25.5 Hz 0.0 When the current is higher than the speed The Current Level of Speed Tracing tracingcurrent level, the output frequency will trace downward. 0~200% of drive rated current Delay Time before Speed Tracing Set the output delay time before the speed tracing. ~5.0 1% 150 The V/F Pattern of Set the percentage of V/F output voltage at the speed Speed Tracing 0~100% 1% 100 tracing. F_091 Error Record Display the latest 5 error records. 0: Parameters are changeable. Maximum frequency cannot exceed 120.0Hz. F_093 F_094 F_095 Parameter Setting Lock Automatic Voltage Regulation (AVR) Drive Overload (OL1) Power Source 1: Parameters are locked. Maximum frequency cannot exceed 120.0Hz. 2: Parameters are changeable. Maximum frequency can exceed 120.0Hz. 3: Parameters are locked. Maximum frequency can exceed 120.0Hz. 1: Enable 1: Thermal protection 2: Current limit overload protection 3: Both 1 and 2 enable The value of setting according to the actual power source. 0.5 0~3 0 0,1 1 0~3 3 190.0~ 240.0 340.0~ 480.0 V 220.0 (Note3) 380.0 (Note4)

Func. Name Description The drive accelerates to the holding frequency and F_096 Holding running at constant speed. F_097 F_098 F_099 F_100 F_101 F_102 F_103 Holding Time Interval Grounding Fault Protection (GF) External Indicator 1 External Indicator 2 External Indicator 3 V/F Pattern Subtracted of Deceleration at Power Failure The drive runs at holding frequency by constant speed and running the time interval. 1: Enable(GF) Select the monitor mode of external indicator 1 Select the monitor mode of external indicator 2 Select the monitor mode of external indicator 3 0:Linear. 1: Energy-saving mode (auto-adjust V/F pattern according to the load condition). 2: Square curve. 3: 1.7 th power curve. 4: 1.5 th power curve. When the power failure, drive will reduce the frequency level before ramp to stop. F_078 Operation at Instantaneous Power Failure =2 or 3 Deceleration Time Set a deceleration time down to the turning frequency F_104 1 of Ramp to Stop set in F_106. by Power Failure Deceleration Time Set a deceleration slope below the frequency set in F_105 2 of Ramp to Stop F_106 by Power Failure 13 Range of Setting Unit Default 0.0~400.0 Hz 0.5 0.0~25.5 0.0 0, 1 1 0~8 1 0~8 2 0~8 3 0~4 0 0.0~20.0 Hz 3.0 0.0~ 3200.0 0.0~ 3200.0 15.0 (Note5) 15.0 (Note5) Set the turning frequency level of ramp to stopwhen Turning F_106 the deceleration time is switched from F_104 setting 0.0~400.0 Hz of Ramp to Stop value to F_105setting value. 0.0 When the noise of analog input signal is Analog large,appropriately increase the dead band to F_107 0.00~2.55 0.01 Dead Band stabilize the frequency command. But adjusting this Hz 0.00 function will reduce the tuning linearity of input signal. F_108 Digital Input When the pulse width of digital signal is lower than Response Time setting time, the signal disabled. 5~16 1ms 10 F_110 ADJ4 Function Set the function of ADJ4switch of KP-202 keypad. 0~49 1 F_111 ADJ5 Function Set the function of ADJ5switch of KP-202 keypad. 0~49 20 F_112 ADJ6 Function Set the function of ADJ6switch of KP-202 keypad. 0~49 17 F_113 DIP1 Function Set the function of DIP1switch of KP-202 keypad. 0~15 8 F_114 DIP2 Function Set the function of DIP2switch of KP-202 keypad. 0~15 5 F_115 DIP3 Function Set the function of DIP3switch of KP-202 keypad. 0~15 3 F_116 DIP4 Function Set the function of DIP4switch of KP-202 keypad. 0~15 1 Pot Knob of F_117 KP-202 keypad Set the function of pot knob of KP-202 keypad. 0~49 0 Function

Func. Name Description F_118 F_119 F_120 F_121 F_122 F_123 F_124 F_125 F_126 F_127 F_128 F_129 F_130 F_131 F_132 0: Clear the UP/DOWN frequency command when UP/DOWN power failure. Memory 1: Save the UP/DOWN frequency command at F_121 when power failure. 0: 0.01Hz UP/DOWN 1~8: x0.05hz 9: 0.5Hz Resolution 10~250: xhz 1~5: Cntinuousaccel./decel. when the terminal is UP/DOWN Trigger activated with the duration (1 ~ 5 ). Mode 6: Edge trigger UP/DOWN Adjust UP/DOWN frequency by KP-201C keypad. Adjustment Secondary CommandSelectio n Analog Input Analog Input (Vin) Analog Input (Iin) Iin Range Analog Input Gain(Iin) Analog Input Bias(Iin) Analog Output Signal (AM+) 0: command by analog signal via terminal. 1: command by keypad. 2: command by UP/DOWN terminal. 0: Vin+Iin 1: Vin-Iin 2: Iin-Vin 3: Vin or Iin (switch by multi-function input terminal X1 ~ X6). 0: Analog input gain. 1: command. 2: Current limit level. 3: Analog input (Vin) can adjust output voltage of V/F pattern 0: Analog input gain. 1: command. 2: Current limit level. 3: Analog input (Iin) can adjust output voltage of V/F pattern 0: 4~20mA (2~10V). 1: 0~20mA (0~10V). Range of Setting Unit Default 0, 1 0 0~250 0 1~6 1 0.00~ 400.00 0.01 Hz 0.00 0~2 0 0~3 0 0~3 1 0~3 1 0,1 0 The gain ratio of analog input terminal Iin. 0.00~2.00 0.01 1.00 The bias ratio of analog input terminal Iin. 0: Output frequency. 1: command. 2: Output current. 3: Vin frequency command 4: Iin frequency command. 5: DC bus voltage 6: Output voltaga Analog Output Gain(AM+) The way of settings are same as multi-function output Output Terminal terminals setting.(f_058 ~ F_060) (Ta2/Tc2) -1.00~ 1.00 0.01 0.00 0~6 2 AM+ analog output adjustment ratio. 0.00~2.00 0.01 1.00-11~+11 (Note 7) 1 DC Braking Active frequency level of DC braking at stop. ~60.0 Hz 0.5 at Stop Monitor the setting value of current limit level F_133 Current Limit Level percentage. 14

Func. Name Description F_134 F_135 F_136 F_137 F_154 The color as Default Setting CLF: Clear fault records def60: Restore the default value of drive for 60Hz. def50: Restore the default value of drive for 50Hz. SAv: Save the setting value. Range of Setting Unit Default res: Restore the setting value. rd_ee: Read the parameters from drive to digital keypad Wr_EE: Write the parameters from digital keypad to drive 1: Paramerter cannot be changed after F8 locked, Parameter Display but it can display the setting value. of Parameter Lock 2: Paramerter cannot be changed after F8 locked, but it cannot display the setting value. 0~1 0 Parameter Lock Setting the password of parameter lock. Password Setting 0~9999 1 0 Parameter Lock Decording the password of parameter lock. Decoding Setting 0~9999 1 Default Setting CLF: Clear fault records def60: Restore the default value of drive for 60Hz. def50: Restore the default value of drive for 50Hz. SAv: Save the setting value. res: Restore the setting value. rd_ee: Read the parameters from drive to digital keypad(kp-201c) Wr_EE: Wr_EE: Write the parameters from digital keypad(kp-201c) to drive means the functions can be set during operation. 0 Note: 1. Default value of 50Hz. 2. Default value of 60Hz. 3. Specification of 200V series. 4. Specification of 400V series. 5. 0.5 ~ 5HP: 5 7.5 ~ 30HP: 15 40HP above: 30 6. RM5G series: When switching frequency setting exceeds 4, the drive must be de-rating or selecting higher capacity. RM5P series: When switching frequency setting exceeds 2, the drive must be de-rating or selecting higher capacity. 7.+: Represents a contact (N.O) -: Represents b contact (N.C) 15

Error Trip Messages of Drive Display Description Display Description (EEr) (OLO) EEPROM error System overload (AdEr) (thr) A/D converter error External fault (SC) Fuse open (PAdF) Keypad interruption during copy (LE1) Under voltage during operation (OH) Drive overheating (OC) (OL) Drive over current Motor overload (GF) (OL1) Grounding fault Drive overload (OE) Over voltage Warning Messages of Drive Display Description Display Description (LE) Power source under voltage (PrEr) Software fault (Err_00) (bb) Drive output interruption (Err_01) Err_00: Keypad cable trip.(beforeconnecting) Err_01: Keypad cable trip.(connected) (Fr) Coast to stop (dtf) Direction command error (db) Over voltage at stop (Wr_F) Different software version inter-copy 16