T80 Universal Transmitter S80 Intelligent Sensors

Similar documents
INSTRUCTION MANUAL MODEL T80 UNIVERSAL TRANSMITTER T80 IMC13

Model T28 Transmitter

INSTRUCTION MANUAL M ODEL T80 U NIVERSAL T RANSMITTER. T80 IM Rev. F

Intrinsically Safe Temperature Concentrator System

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet

Signet ph/orp Transmitter * *

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

+GF+ SIGNET ph/orp Transmitter Instructions

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Cole-Parmer Instrument Company

IPM650 Intelligent Panel-Mount Display

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

Neon pr. ph/ ORP measurement. Applications. Description

Handheld Water Quality Meters 100 Series

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

Solutions to the Most Challenging Environments

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water

SMART SENSORS. Water quality sensors with built in digital & analog microtransmitters

Range. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable

INSTRUCTION MANUAL MODEL TC80 TOTAL CHLORINE ANALYZER MODEL DC80 DECHLORINATION ANALYZER. TC80 IM Rev. C

Microprocessor ph/orp Controller

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Economical Rugged Series M1300K

Benchtop Multi-parameter Water Quality Meter

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

Control and automatic dosing

INSTRUCTION MANUAL. Portable ph and ph/ise Meters. Models 210Aplus 230Aplus 250Aplus 290Aplus

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Intelligent SUNTEX EC4110(RS) Conductivity Transmitter

Description, continued

Temperature/Process Controllers Manual

IXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board.

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet

OPERATING INSTRUCTIONS FOR LXT-220. Dissolved Oxygen Controller DANGER

FLXA202/FLXA21 2-Wire Analyzer HART Communication. Functions Available via HART Communication...4. DD Menu Structure for ISC Meter Functions

SX90 Process Controller

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

Dissolved Oxygen Meter Kit DOK. Instruction Manual

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

User Manual. Thermo Scientific Orion Star A320 Series

Analyzer/Sensor to measure UV Spectral Absorbance

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Operations Manual EcoSense ph100a

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

and Multiparameter Meters

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK


B: Boiler Condensate Conductivity

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

ph/orp CONTROLLER PH/ORP800 INSTRUCTION MANUAL

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

From lab to production, providing a window into the process. Universal Input Indicator Start-up Guide. Operating Manual.

Signet 9900 Transmitter

WK7200. Water Quality Test Kit USER S MANUAL

Operating Instructions. DIN Rail Transmitter M100 DR

Handheld Water Quality Meters 100 Series

Safety. 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

PT2 / ST2 PROCESS TRANSMITTER SYSTEM

Model Q46F/82 Direct Fluoride Monitor

ezeio Controller and the 2400-A16 input expansion.

Handheld Water Quality Meters 100 Series

Integrated Instruction Manual WP 600 Series Meters

Plug & Play Analytical Solutions Making Basic Measurements Easy

HI5221 & HI5222. ph/mv/ise/temperature Bench Meters INSTRUCTION MANUAL

Operating Instructions

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no:

4801P ph/orp controller

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

CII: Current Input, Isolated

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors. Stratos

Modbus Communications Board

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)

Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01

ph and Electrochemistry

INSTRUCTION MANUAL ORP-METER MODEL COR-01

Table of Contents. Chapter 1 Introduction General Information... 1 Meter Packing List... 2

CDTX-45T Portable Toroidal Conductivity Meter

Control instruments GUARDIAN 2 - GUARDIAN 3

DTM Distributed Transmitter Monitor

About Suntex. Online Measurement and Control. Portable and Laboratory Instruments. ISO 9001: 2000 Certificated since 2001

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

Modbus Communications Board

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

Simplified information where and how you want it.

VAT series controller and transmitter. Manual

Transcription:

T80 Universal Transmitter S80 Intelligent Sensors Presented by: January 2012 ELECTRO-CHEMICAL DEVICES

T80 Universal Transmitter One Transmitter for Multiple Measurements ph ORP Dissolved Oxygen All Specific Ions Conductivity Resistivity Turbidity

T80 Universal Transmitter Easy to Use Membrane Switch Navigation Simple Menu Structure Soft Key Menu Choices Easy to read 2 ¾ x 1 ½ LCD Display

T80 Universal Transmitter Inputs: Any S80 Intelligent Sensor Any standard ph sensor with solution ground using the optional T80 input card. Outputs: 4-20 ma MODBUS RTU on 24 VDC and 110/220 VAC instruments Optional HART 7 Optional 3 Alarm Relays Power requirements: Loop Powered 24 VDC @ 250 mw minimum 110/220 VAC

S80 Intelligent Sensors New but Familiar Digital Communication with Transmitter Sensor Type Serial Number Process Variable Temperature Calibration Data Waterproof, IP68 rated Industrial Detachable Cable Connection

S80 Intelligent Sensors 6 Point Advantage 1. Intelligent Sensor 2. Common Configuration for all Measurements 3. Application Specific Cartridges 4. Economic and Easily Replaceable Cartridges 5. Submersible and Retractable designs 6. Application Specific Materials of Construction

Three Home Screens Data Screen Process Variable % 4-20 ma range Temperature mv Screen T80 Home Display Raw mv signal from the sensor % 4-20 ma range Temperature Graphical Screen 3 choices, Line, Bar, Gauge Process Variable % 4-20 ma range

T80 Main Menu Press any Key Twice, except the Screen Key, within 1 second to enter the Main Menu CAL = Calibration CONFIG=Configuration CONFIG=Configuration INFO = Information SIM = Simulation HOLD = Output Hold Function Toggles ON/OFF Freezes the 4-20 ma and alarm relays

T80 Calibration New Sensor? YES-Erases all 3 Calibration registers NO-Saves to top register Auto Calibration Two point Cal Automatically recognizes the Calibration Solution Standardize Single point adjustment Manual User entry of the Offset and Slope for sensor Temperature Temperature Adjustment

T80 Auto Calibration The Easy to use T80 prompts the user through the calibration. Press AUTO and Cal 1 and the T80 waits for a stable reading and then Suggests the value of the Calibration Standard Accept the value (YES)or enter a different value (NO) Continue to the next solution (YES) or end the calibration (NO).

T80 Auto Calibration The 2 nd standard solution is suggested when the sensor stabilizes Accept the value or enter a different one The Calibration Offset and Slope values are displayed Press OK to exit the Calibration Mode and Exit to leave the Menu Save the Changes to return to the Main Display

T80 Manual Calibration Manual Calibration allows the Offset and Slope to be entered manually Test an electrode in the shop and install it and enter the Cal Data in the field Enter the PV value, Press mv and enter the associated mv value Accept the entry and enter the slope value Accept the Slope, press OK, Exit and Save the changes

Configure Transmitter LCD Display Contrast C/ F OUTPUT 4-20 ma, Relays SERIAL T80 Configure MODBUS or HART addresses PASSWORD Set Level and Password Configure Sensor Type of Sensor, ph, ORP Temp Compensation, %/ C Isopotential point

Display Set Up C or F Slider for Contrast Time Out for Back Light Soft Keys -Text or Icons Line, Gauge or Bar Graphs Line graph duration 1 minute, 15 minutes, 1 hour, 12 hours, 1 day, 2 days Tag -52 characters Tag On-Displays Tag in Home screen Pop Up Turns press twice screen ON/OFF Configure the Display

Configure Outputs -4-20 ma Set The 4-20 ma RANGE Default setting is the range of the sensor Select 4 ma/20 ma, enter value HOME, EXIT, SAVE Calibrate the Output Transmitter sends out 4 ma signal Enter measured value press OK Transmitter sends out 20 ma signal Enter measured value and press OK Repeat as needed Choose 4-20 ma Fault Condition 3.5 ma 22 ma Disable, none

Configure Outputs - Relays 3 Relays SPDT,form 1C, 250 VAC, 5 Amp resistive maximum Choose Relay function Alarm Set Point Fault Failure Alarm Disable Inactivates relay and removes Icon from Home Display Configure Alarm set point Set Point ON value Set Point OFF, determines whether Hi/Lo set point Delay Times, Amount of time the PV must stay above or below set point before activation

Hold, Serial, Password Output Hold Sets the Hold Time Out Function Serial Configuration Address (MODBUS + HART ) Baud (MODBUS only) Format (MODBUS only) Format (MODBUS only) Password Protection Choose Level Enter 4 character password, case sensitive Master Password in Manual

INFO T80 Transmitter Transmitter INFO Serial #, revision levels, Hardware Software T80 Configuration Relay configurations 1-3 4-20 Configuration

INFO S80 Sensor Sensor INFO Process Variable, serial #, Firm ware revision Sensor s Range Calibration Logs Logs 1 3 Offset & Slope

System Simulate T80 generates a signal equivalent to the PV signal Enter Fixed Value Ramp ( then ) Cycles the Range from the low value to the high value and back. Adjustable cycle time Triggers Relays and varies 4-20 ma Out Simulation - System

Simulation Relays & 4-20 ma Relay Simulation Puts the Relays under manual control Choose Relay and turn it ON or OFF 4-20 ma Simulation Enter ma value for T80 to output That completes the Menus, CAL, CONFIG, INFO and SIM

Wiring and Power Board Color Code and Connection type embossed into the protective Circuit Board cover 110/220 VAC Power Board AC In 24 VDC Out Optional preamp for mv+, mv-, TC, TC, SG input

T80 Universal Transmitter One Transmitter for All Measurements Loop Powered, 24 VDC or 110/220 VAC Options HART 7 or MODBUS RTU With or without 3 Alarm Relays

Model T80 Part Number Guide Model T80- Transmitter Part Number Guide Input 10 S80 Sensor, ph, ORP, pion, Conductivity, Resistivity, Turbidity and galvanic Dissolved Oxygen 20 Optical DO and Amperometric ppb DO Sensors (Triton DO8 and DO9 sensors) 30 Internal Digital Converter/Preamp Power Supply -0 Loop Powered Transmitter -1 24 VDC Powered Transmitter -2 110/220 VAC powered Transmitter Alarm Relays 0 No Relays 1 (3) Form 1C, 250 V 5A relays Output 0 4-20 ma output and MODBUS RTU 1 HART 7 Mounting Hardware Model T80-10 -2 1 1-01 -00 No Mounting Hardware -01 Universal Mount -02 Panel Mount -03 Handrail Mount -04 Sunshield Vertical Rail Mount -05 Sunshield Horizontal Rail Mount

S80 Intelligent Sensors Noise free digital Communication Calibrated sensors, Plug and Play Easy Maintenance IP68 Waterproof Detachable Cable The same Electrode Cartridges, Fittings and Hardware as the S10 and S17 sensors

Electro-Chemical Devices Thank You, Goto www.ecdi.comfor Data Sheets/ Instruction Manuals/ Presentations/ Press Release Packages For over 30 years Electro-Chemical Devices (ECD) has been a recognized leader in industrial process instrumentation: Liquid analytical sensors, controllers, transmitters, analyzers and electrodes. Electro-Chemical Devices 1681 Kettering Irvine, CA 92614 Phone: +1-949-336-6060 +1-800-729-1333 Fax: +1-949-336-6064 email: sales@ecdi.com web: www.ecdi.com