Tipping Point. Introduction. Bypass Switch Operation SOLUTION BRIEF

Similar documents
WHITE PAPER. Fail-Safe IPS Integration with Bypass Technology

Ixia Net Optics ibypass 1Gb Fiber

Introduction to Cisco ASR 9000 Series Network Virtualization Technology

Cisco FirePOWER 8000 Series Appliances

SINGLEstream Link Aggregation Tap (SS-100)

How to properly deploy, configure and upgrade the NAB

McAfee Network Security Platform

HP S1500 SSL Appliance. Product overview. Key features. Data sheet

Configuring Rapid PVST+

3299 Rack Mount. Product Highlights. Multifunctional BypassP 2 Segment. Switching Fabric

Ixia xbalancer. A Purpose-Built Load Balancer for 10G Networks. The Load Balancing Solution DATA SHEET. Highlights

The Conversion Technology Experts. Choosing a Fast Ethernet Media Converter

IXIA IBYPASS HD DATA SHEET PROBLEM: INLINE TOOLS ARE A SINGLE POINT OF FAILURE IN THE NETWORK

Deploying 10 Gigabit Ethernet with Cisco Nexus 5000 Series Switches

Configuring Rapid PVST+ Using NX-OS

Configuring High Availability (HA)

Network Security Platform Overview

Maximizing visibility for your

Cisco SCE 2020 Service Control Engine

IPS Device Deployments and Configuration

Configuring Interfaces

PowerConnect 'HOO_3RZHU&RQQHFW. Key Points. Product Description

Ixia xstream TM 10. Aggregation, Filtering, and Load Balancing for 1GbE/10GbE Networks. Aggregation and Filtering DATA SHEET

BROCADE ICX 6610 SWITCHES FREQUENTLY ASKED QUESTIONS

Concept Questions Demonstrate your knowledge of these concepts by answering the following questions in the space provided.

Juniper Virtual Chassis Technology: A Short Tutorial

Installing the IPS 4345 and IPS 4360

Overview of Ports and Interfaces

McAfee Network Security Platform

CIO Update: Security Platforms Will Transform the Network Security Arena

THE INVISIBLE UPGRADE: MOVING TO 1Gbps

Network Service Assurance

BT Connect Networks that think Optical Connect UK

Device Management Basics

Ref: C8-1G. The 8-Link Gigabit Copper TAP is a high density solution, providing 8 TAP links in a 1U rack space

Load Balancing with McAfee Network Security Platform

Data collected by Trend Micro is subject to the conditions stated in the Trend Micro Privacy Policy:

Designed, built, and tested for troublefree operation in extreme conditions

Interface Configuration Mode Commands

Enterasys K-Series. Benefits. Product Overview. There is nothing more important than our customers. DATASHEET. Operational Efficiency.

Ethernet Network Redundancy in SCADA and real-time Automation Platforms.

5.11 Parallelism and Memory Hierarchy: Redundant Arrays of Inexpensive Disks 485.e1

UNDERSTANDING SENETAS LAYER 2 ENCRYPTION TECHNICAL-PAPER

Configuring Interfaces

Device Management Basics

Redundancy and Fail-Over

Troubleshooting. Diagnosing Problems. Verify Switch Module POST Results. Verify Switch Module LEDs CHAPTER

Ixia Net Optics ilink Agg xstream

Product Overview. Features CHAPTER

Take Back Lost Revenue by Activating Virtuozzo Storage Today

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet

Understanding Layer 2 Encryption

IBM Europe Announcement ZG , dated February 13, 2007

ForeScout CounterACT Resiliency Solutions

Check Point 4800 with Gigamon Inline Deployment Guide

IntellaFlex Packet Aggregation Switching Solutions

Install your TPS 440T and 2200T security devices

TippingPoint. Amazon Web Services Microsoft VMware. TPS. TPS DVLabs ZDI

Configuring EtherChannels and Link-State Tracking

M10GxxBP Series Modular Tap Installation Guide

Cisco SFS 7008 InfiniBand Server Switch (96-port)

Configuring Rapid PVST+

WHITE PAPER. Monitoring Converged Networks: Link Aggregation

Product Overview. Switch Models CHAPTER

Product Overview. Send documentation comments to CHAPTER

VIRTUAL APPLIANCES. Frequently Asked Questions (FAQ)

Ethernet Port Configuration Mode Commands

Configuring Basic Interface Parameters

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

Data Sheet. DPtech IPS2000 Series Intrusion Prevention System. Overview. Series IPS2000-MC-N. Features

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Managing Latency in IPS Networks

Introduction to iscsi

Interface Configuration Mode Commands

Network Design Considerations for Grid Computing

S5 Communications. Rev. 1

Security is one of the biggest concerns today. Ever since the advent of the 21 st century, the world has been facing several challenges regarding the

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

T H E TOLLY. No September Dell PowerConnect 3348 vs. 3Com SuperStack 3

L01 - Basic Stratix Switch and EtherNet/IP Features in Converged Plantwide Ethernet (CPwE) Architectures

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

2015 Product Catalog

Fail safe LAN connectivity

Technical Document. What You Need to Know About Ethernet Audio

40 GbE: What, Why & Its Market Potential

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches

McAfee Network Security Platform

VCStack - Powerful Simplicity

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Objectives. Hexadecimal Numbering and Addressing. Ethernet / IEEE LAN Technology. Ethernet

Pass-Through Technology

Information About Topology

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

Product Overview. Introduction. Hardware Features CHAPTER

Value Added Services (VAS) Traffic Forwarding

CriticalConneX Series V-Line System

TOLLY. Nortel, Inc. Ethernet Routing Switch 5000 Series. Test Summary

Configuring Interface Characteristics

I/O Modules Overview. Before You Begin. I/O Module Options. ESD Requirements

Transcription:

Tipping Point Introduction TippingPoint Intrusion Prevention Systems (IPS s) are designed to the highest reliability standards so customers can deploy them in-band in their networks without worrying about adversely impacting the availability of mission-critical business applications. In fact, in a survey commissioned by TippingPoint and conducted by Infonetics Research in August 2008, respondents reported that more than 90 percent of all TippingPoint IPS appliances are deployed in-band, a strong indication of the reliability of TippingPoint devices. (In contrast, customers of IPS vendors Cisco Systems, IBM-ISS, and McAfee reported less than 70 percent in-band deployments.) However, no matter how reliable an IPS might be, there is not much it can do if it loses power. The IPS must be deployed in-band so it can intercept malicious traffic; if the IPS doesn t have power, no traffic can flow through the link, shutting down the network if redundant connectivity is not available. To remedy this situation, some IPS s have Zero Power High Availability (ZPHA) circuitry built in. This circuitry, often called a bypass switch, automatically opens the link when the unit does not have power, ensuring that network traffic can flow at all times. If an IPS does not include a built-in bypass switch, an external bypass switch may be used, and is recommended for most IPS deployments. In fact, an external bypass switch brings some additional value to the solution, because it also keeps the link traffic flowing if the IPS is removed for maintenance or redeployment, or if the IPS or one of its links fails. This paper looks at how an external bypass switch can increase application availability in an IPS deployment, and how such a solution can be installed and configured. In normal operation, the bypass switch routes all network traffic through the IPS, and the IPS performs its inspection and filtering function in its usual manner, exactly as if the IPS were directly in-band itself. The bypass switch, however, has the capability of bypassing the IPS and passing traffic directly through the link as shown in Figure 3. Figure 1: IPS deployed with an external bypass switch Figure 2: IPS functions as if in-band Bypass Switch Operation A bypass switch, whether internal or external to the IPS, is a device that is designed to provide a fail-safe connection for in-band equipment such as IPS s. As shown in Figure 1 for an external bypass switch, the bypass switch is installed in-band in the network link, and the IPS attaches to the bypass switch. Figure 3: Bypass switch takes IPS out-of- band Page 1

A Real-World Example Figure 4: TippingPoint 5000E IPS paired with a Net Optics Multi-Segment Bypass Switch One scenario in which the bypass switch will take the IPS out-of-band is if the IPS loses power, and therefore cannot process network traffic. For this reason, an external bypass switch is recommended if the IPS is not equipped with one internally. In addition, when an IPS is paired with an external bypass switch, the IPS can be removed from the link at any time; the bypass switch senses the absence of the IPS and instantly opens the network link to traffic flow. While the benefits of a bypass switch are evident, you may wonder whether you are simply replacing one risk with another, because the bypass switch is subject to failure as well. However, having a bypass switch in-band instead of the IPS itself has several advantages: The bypass switch, whether internal or external, ensures that link traffic continues to flow when no power is available A bypass switch is a much simpler device than an IPS, so it is much less likely to fail A bypass switch passes 100 percent of the network traffic, no matter how busy the link is; it never runs out of bandwidth and therefore never needs to be upgraded External bypass switches are often installed in critical links as permanent parts of the network infrastructure, so they never need to be removed from links, even when the security strategy or the network configuration changes A perfect companion bypass switch for TippingPoint 5000E and 2400E IPS s (which do not have internal bypass switches) is a Net Optics Four- Station Multi-Segment Bypass Switch. Both devices support four network links, and both can be ordered in configurations with all copper, all fiber, or half copper and half fiber ports. Both SX and LX fiber are supported. The two devices can be paired as shown in Figure 4. This configuration protects four critical network segments and occupies only 3U of rack space, 2U for the IPS and 1U for the Bypass Switch. For example, a TippingPoint 2400E appliance is often a good choice to protect four 1-gigabit-per-second network links if the links are less than 50 percent utilized. However, suppose that over time network usage grows and the 2-gigabit-per-second aggregate throughput capability of the 2400E becomes a bottleneck on the network. A properly managed network may function well at utilizations of 80 percent or more, so it may be possible to continue to meet service- level agreements without upgrading the network except that the IPS no longer has the bandwidth to handle all of the traffic. The most cost-effective solution may be to upgrade from a 2400E to a 5000E, which supports 5 gigabits per second of throughput. If the 2400E was deployed with a Multi-Station Bypass Switch, upgrading is a cinch. The cables are simply unplugged from the 2400E (the Bypass Switch automatically and transparently keeps the network traffic flowing), the 5000E is swapped for the 2400E in the rack, and the cables are plugged into the 5000E. As soon as the 5000E is powered up and is capable of passing traffic, the Bypass Switch automatically switches it in-band and the network is protected. There is no need to wait for a maintenance window or worry about impacting application traffic. Failover Operation Let s take closer look at how an external bypass switch keeps the traffic flowing. Page 2

The Net Optics Multi-Station Bypass Switch has three mechanisms for triggering a bypass, that is, for taking the IPS out-of-band. The mechanisms are power loss detection, link loss detection, and Heartbeat packet. Each of these mechanisms is described in the following sections. Power Loss Detection The Multi-Station Bypass Switch has dual redundant power supplies and ZPHA circuitry that detects loss of power. When the dual redundant power supplies are connected to independent power sources, total loss of power should be rare, because either power supply alone can power the unit. However, when both power sources fail, the ZPHA circuitry ensures that the Bypass Switch creates an open channel that enables network traffic to keep flowing while the Bypass Switch has no power. When power is restored, the Bypass Switch automatically comes back on-line and, if the IPS is detected to be present and functioning, restores the flow of network traffic through the IPS. The Tolly Group conducted independent tests on a Net Optics Bypass Switch (10/100/1000 copper model) in April 2008. They reported the time from a power fail condition on the Bypass Switch to when the network connection was re-established and traffic resumed flowing to be 0.82 seconds. Link Loss Detection The Multi-Station Bypass Switch monitors the links between its ports and the IPS. If a link is dropped, the switch immediately enters bypass on mode taking the IPS out-of- band and enabling traffic to flow unimpeded through the link. The Tolly Group induced this condition by unplugging one of the cables that connected the Bypass Switch to the IPS, and measured a failover time of 0.76 seconds. This test reflects the real-world scenario wherein the IPS is removed from the network for any reason, and demonstrates that application traffic keeps flowing when the IPS is simply unplugged and removed. A third method of triggering a bypass on condition is required for cases when the Bypass Switch remains powered and the links to the IPS remain up. An example of this scenario is when the traffic exceeds the capacity of the IPS, so that latencies through the IPS start to increase. To detect this type of condition, the Bypass Switch periodically sends small Heartbeat packets through the IPS to confirm that it is operational. The Heartbeat packets are sent out one port to the IPS, and the Bypass Switch expects to see the packet returned on the other port within a certain amount of time. If the packet does not arrive within the expected time window, the Bypass Switch assumes the IPS is having a problem and takes it out-of-band. (The Heartbeat packet is received by the Bypass Switch but it is never passed to the external network link.) The Tolly Group tested the Heartbeat packet mechanism by programming the IPS to filter the Heartbeat packet, so it would not be returned to the Bypass Switch. They determined that in this scenario, the failover time was less than one millisecond. Device Management TippingPoint IPS s are quick and easy to deploy. Fortytwo percent of TippingPoint customers in the previously referenced Infonetics Research survey reported installing the IPS in less than 30 minutes, and 76 percent in less than two hours. (For comparison, only 17 percent of IBM- ISS customers reported a two-hour or less set-up time.) In addition, two- thirds of TippingPoint customers said that only a light effort was required to configure the IPS filters, and only three percent said it took significant effort. Some customers may wish to adjust some of the Bypass Switch s configurable features for their application. Bypass Switch configuration is easily accomplished with a command-line interface (CLI) operating over an RS232 serial port. The Multi-Segment Bypass Switch has a separate RS232 port for each of the four segments, because the Bypass Switches that control the segments are completely independent from each other for added reliability and security. Page 3

The configurable features of the Bypass Switch include the following: Link Fault Detect (LFD) disables the remaining side of a full-duplex link when one side of the link fails, ensuring that the network can failover to an alternate path (if available) in a timely manner; the default setting for LFD is On Bypass Detect when in bypass on mode, Bypass Detect cycles the monitor ports through five seconds off followed by ten seconds on; the resulting alternating link status can trigger the attached IPS to send an alarm to a management system; Bypass Detect activates when the Heartbeat packet is not returned from the IPS device; the default setting of Bypass Detect is Off Fail Mode When the Fail Mode setting is open, the bypass on state of the switch is to open the network link and permit traffic to flow, as discussed previously; when the setting is closed, the bypass on state closes the network link so no traffic flows, enabling failover network settings to take effect; the default setting for Fail Mode is Open Figure 6: Bypass triggered by loss of link between the IPS and the Bypass Switch Figure 7: Operation of the Bypass Switch Heartbeat packet Figure 8: Net Optics Multi-Segment Bypass Switch Front Panel Figure 5: Bypass triggered by loss of power to the Bypass Switch In addition, 10/100/1000 copper-media ports can be configured to a fixed speed of 10, 100, or 1,000 megabits per second, and to full or half duplex mode. The default settings are automatic negotiation of link speed, and full duplex mode. The Bypass Switch s Heartbeat packet is also configurable. Besides the actual packet content, the interval between Heartbeat packets and the retry count may be configured. The default interval between Heartbeat packets is one second; it can be set from 1 to 254 seconds. The default retry count is three, meaning that the Bypass Switch takes the IPS out-of-band when three Heartbeat packets have failed to be returned. The retry count can be set from 1 to 254. The default Heartbeat packet configuration works well with Tipping Point 5000E and 2400E IPS s. Page 4

The status of the links and the bypass state of the Multi- Segment Bypass Switch can be viewed through the CLI. It is also shown with LEDs on the device s front panel. Each of the four independent switches has a pair of LEDs that show whether the state is bypass on (IPS out-of-band) or bypass off (IPS in-band). In addition, each port has two LEDs displaying the link state: a Link LED that indicates whether the link is present or not, and an Activity LED that flashes when data is passing through the port. For 10/100/1000 ports, the color of the Link LED also indicates the link speed, amber for 10 megabits per second, yellow for 100 megabits per second, and green for 1,000 megabits per second, as clearly explained with a key silkscreened on the panel. Finally, each of the four switches has a pair of LEDs indicating whether the two redundant power supplies are active or off. If remote management of the Multi- Segment Bypass Switch is desired, an inexpensive four-port RS232 terminal server can be obtained from any of a number of sources to enable access to the management ports over a network or over the Internet. Conclusion TippingPoint IPS s are designed for maximum reliability, with features such redundant configurability, link down synchronization, and hardware watchdogs. However, availability of business-critical applications can still be affected when an IPS loses power, of if it needs to be removed from a network link or upgraded to a new model. An external ZPHA or bypass switch ensures a higher level of application availability by guaranteeing that link traffic keeps flowing in all of these scenarios. A Net Optics Four- Station Multi-Segment Bypass Switch is an ideal companion for TippingPoint 5000E and 2400E IPS s because together they can protect four critical network links with as much as 5 gigabits per second of total traffic, with high reliability and the flexibility of being able to remove or upgrade the IPS s at any time, without risking the availability of critical business applications. Page 5