ES-762. Utility Metering Flow Computer with Multichannel Aux. Inputs & Totalizers

Similar documents
SUPERtrol II Flow Computer

EA403 FLOW COMPUTER West Stetson Avenue Hemet, CA USA

LEVELtrol-II Flow Computer

KESSLER-ELLIS PRODUCTS

Installation and Operating Manual for

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

LAUREL ELECTRONICS, INC.

VA11 FLOW COMPUTER. USA KROHNE Inc. 7 Dearborn Road Peabody, MA TEL.: FAX:

Trident and Trident X2 Digital Process and Temperature Panel Meter

NF770 Temperature Compensation Liquid Flow Computer

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Model FP-100 General Specification

Product Description. Contents. Fusion Series. New Information December 2003

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

923-ST1MANIFOLD-FC Flow Computer

SUPERtrol-I LE Flow Computer

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LBVR1718. Description. Features channel paperless recorder

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

Digital Indicator Solutions

NF760 Batch Controller

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

High Voltage DC Meter

LAUREL ELECTRONICS, INC.

Digital Panel Meters

HIGH-VOLTAGE DC METER

/8 DIN Universal Process Indicator

Conductivity Transmitters

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

clarity 3 Programmable Controller

MID approval no. DE-08-MI004-PTB004 Date of release

Comprehensive Modular Genset Controller

PD765 TRIDENT. Trident Series Process & Temperature Meters.

INDEX. INTRODUCTION PAGE DESCRIPTION KEP Company Overview 3 A brief history of our company.

dual-line 6-dIGIt process MeteR

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

C500 Series Data Sheet

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

PD765 TRIDENT. Trident Series Process & Temperature Meters.

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

7511 / / / 711 / / 731 / Preset 27

Flow Measurement SITRANS F US Clamp-on

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

INSTALLATION INSTRUCTIONS

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

UTM10 Series Ultrasonic Transit-time Flowmeters

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Scanner 2000 microefm

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Scanner 2000 Steam Mass Flow Transmitter

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Simplified information where and how you want it.

Micro Motion Model 7950 and Model 7951 Signal Converters

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

MIC-2 MKII, Multi-instrument DATA SHEET

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

/8 DIN Motorized Valve Controller

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

InteliLite MRS17 Click Here to Learn More

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

MPV. Process Panel Display. Dual-Line Rate and Total

MODCELL 2050R Single Loop Controllers

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

DTM Distributed Transmitter Monitor

DUAL-LINE TEMPERATURE METER

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Process & Temperature Digital Panel Meter

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

iologik 4000 Series (M) Modules

Dynamic Flow Computers, Inc Southwest Freeway, Suite 320 Stafford, TX Ph: (281) Fax: (281)

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers BATCH CONTROL. PRECISION DIGITAL CORPORATION SERIES

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

Thermo Scientific CM515 and HME900 Density Converter Electronics

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

Multi-Point Gas Detection and Control System

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

VersaMax Micro and Nano Technical Product Presentation

Product Data: Micro MV 100

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

Features and Benefits. Certifications

Family of Water Cut Analyzers

Transcription:

EZ Setup - Guided Setup for First Time Users Utility Metering of Steam and Heating or Cooling Water Energy Two Auxiliary 4-20mA Analog Inputs Four Auxiliary Pulse Inputs and Totalizers for Secondary Measurement of Total from other meters Menu Selectable Hardware & Software Features Internal Data Logging Isolated Pulse and Analog Outputs Standard RS-232 Port Standard, Provides Power for Modem RS-485 Modbus RTU ES-762 Internal Communication Card Option Supports: BACnet IP, BACnet MS/TP, Metasys N2, Modbus TCP, AB Ethernet IP, AB DF1, LonWorks* Windows Setup Software Supports Most Flowmeter Types Stacked DP Transmitters Supported Utility Metering Flow Computer with Multichannel Aux. Inputs & Totalizers DDE Server & HMI Software Available Remote Metering Solutions Optional - Attractive Wall Mount Enclosure Description: The ES-762 Flow Computer primarily satisfies the instrument requirements for a variety of flowmeter types in liquid, steam and heat applications. Multiple flow equations are available in a single instrument with many advanced features. Two auxiliary current and four totalizer inputs are provided for secondary measurements. The alphanumeric display offers measured parameters in easy to understand format. Manual access to measurements and display scrolling is supported The versatility of the Flow Computer permits a wide measure of versatility within the instrument package. The various hardware inputs and outputs can be soft assigned to meet a variety of common application needs. The user soft selects the usage of each input/output while configuring the instrument. Multichannel auxiliary inputs can gather other information from site. Applications Include: Steam Mass, Steam Heat, Chilled Water Only, Heated Water Only including Low DeltaT cutoff. The isolated analog output can be chosen to follow the volume flow, heat flow, mass flow, temperature, pressure, or density by means of a menu selection. Most hardware features are assignable by this method. The user can assign the standard RS-232 Serial Port for external data logging, transaction printing, or for connection to a modem for remote meter reading. A Service or Test mode is provided to assist the user during start-up system check out by monitoring inputs and exercising outputs. The system setup can also be printed. Specifications: Environmental Operating Temperature: 0 to +50 C Storage Temperature: -40 to +85 C Humidity : 0-95% Non-condensing Materials: UL, CSA, VDE approved Display Type: 2 lines of 20 characters Types: Backlit LCD. OLED and VFD ordering options Character Size: 0.2 nominal User selectable label descriptors and units of measure Keypad Keypad Type: Membrane Keypad with 16 keys Keypad Rating: Sealed to NEMA 4X / IP65 Enclosure Enclosure Options: Panel & Wall Mounting Styles Size: See Dimensions Depth behind panel: 6.5 including mating connector Type: DIN Materials: Plastic, UL94V-0, Flame retardant Bezel: Textured per matt finish Power Input The factory equipped power option is internally fused. An internal line to line filter capacitor is provided for added transient suppression. MOV protection for surge transient is also supported Universal AC Power: 85 to 276 Vrms, 50/60 Hz DC Power Option: 24 VDC (16 to 48 VDC) Power Consumption AC Power: 6.5 V/A DC Power: 300 ma max. * LonWorks protocol requires a different module assembly from the other available protocols. LonWorks is not field selectable. 990159 11/09/16

Flow Meter Types: Linear: Vortex, Turbine, Positive Displacement, Magnetic, GilFlo, ILVA, Ultrasonic, Mass Flow and others Square Law: Orifice, Venturi, Nozzle, V-Cone, Wedge, Averaging Pitot, Target, Accelabar and others Multi-Point Linearization: May be used with all flowmeter types. Including: 16 point, UVC and dynamic compensation. Flow Inputs for Primary Flow Computations: Analog Input: Accuracy: 0.02% FS at 20 C Ranges Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC Current: 4-20 ma, 0-20 ma, 4-20 ma stacked, 0-20 ma stacked Basic Measurement Resolution: 16 bit Update Rate: 4 updates/sec Automatic Fault detection: Signal over/under-range, Current Loop Broken Calibration: Operator assisted learn mode Extended calibration: Learns Zero and Full Scale of each range Fault Protection: Fast Transient: 500 V Protection (capacitive clamp) Reverse Polarity: No ill effects Over-Voltage Limit: 50 VDC Over voltage protection Over-Current Protection: Internally current limited protected to 24VDC Pulse Inputs: Number of Flow Inputs: one Input Impedance: 10 k Ω nominal Trigger Level: (menu selectable) High Level Input Logic On: 2.5 to 30 VDC Logic Off: 0 to 2 VDC Low Level Input (mag pickup) Selectable sensitivity: 10 mv and 100 mv Minimum Count Speed: 0.25 Hz (to maintain rate display) Maximum Count Speed: Selectable: 0 to 50 khz Overvoltage Protection: 50 VDC Temperature, Pressure, Density, and Aux 3/4 Inputs The compensation inputs usage are menu selectable for temperature, temperature 2, pressure, density or not used. In addition, two auxiliary inputs are provided for secondary measurements. Calibration: Operator assisted learn mode Operation: Ratiometric Accuracy: 0.02% FS at 20 C (current input) Basic Measurement Resolution: 16 bit Update Rate: 2 updates/sec minimum Automatic Fault detection: Signal Over-range/under-range Current Loop Broken RTD short RTD open Reverse Polarity: No ill effects Over-Current Limit (current input) Internally limited to protect input to 24 VDC) Available Input Ranges (menu selectable) Current: 4-20 ma, 0-20 ma (4 inputs) Resistance: 100 Ohms DIN RTD (2 inputs) 100 Ohm DIN RTD (DIN 43-760, BS 1904): Three Wire Lead Compensation Internal RTD linearization learns ice point resistance 1 ma Excitation current with reverse polarity protection Temperature Resolution: 0.01 C Accuracy: 0.5 C Stored Information (ROM) Steam Tables (saturated & superheated), Fluid Properties: Water, or Generic with user entries of fluid properties User Entered Stored Information (EEPROM / Nonvolatile RAM) Transmitter Ranges, Signal Types Fluid Properties (reference density, expansion factor, specific heat, viscosity, isentropic exponent, combustion heating value) Units Selections (English/Metric) Secondary Totalizer Aux. Inputs: Input Type: Contact Closure / Pulse Number of Contact Closure / Pulse Inputs: four (4) Input Impedance: 4.7 k Ω nominal Trigger Level: High Level Input Logic On: 4 to 30 VDC Logic Off: 0 to 1 VDC Maximum Count Speed: 25 Hz Excitation Voltage: 5 VDC Overvoltage Protection: 30 VDC User defined: units, scaling, rollover limit, labels Uses: Cold Water, Natural Gas, Hot Water, Electric kw-hr

Excitation Voltage 24 VDC @ 140 ma (fault protected) Relay Outputs The relay outputs usage is menu assignable to (Individually for each relay) Hi/Lo Rate Alarm, Hi/Lo Temperature Alarm, Hi/Lo Pressure Alarm, Pulse Output (pulse options), Aux.3, Aux.4, Wet Steam or General purpose warning (security). Number of relays: 2 Contact Style: Form C contacts Contact Ratings: 240 V, 5 amp Analog Outputs The analog outputs are menu assignable to correspond to the Uncompensated Volume Rate, Aux.3, Aux.4, Mass Rate, Heat Rate, Temperature, Density, or Pressure. Number of Outputs: 2 Type: Isolated Current Sourcing (shared common) Available Ranges: 0-20 ma, 4-20 ma (menu selectable) Resolution: 16 bit Accuracy: 0.05% FS at 20 Degrees C Update Rate: 5 updates/sec Temperature Drift: Less than 200 ppm/c Maximum Load: 1000 ohms Compliance Effect: Less than.05% Span 60 Hz rejection: 40 db minimum EMI: No effect at 3 V/M Calibration: Operator assisted Learn Mode Averaging: User entry of DSP Averaging constant to cause a smooth control action Data Logging The data logger captures print list information to internal storage for approximately 5000 transactions. This information can be used for later uploading or printing. Storage format is selectable for Comma-Carriage Return or Printer formats. Isolated Pulse output The isolated pulse output is menu assignable to Uncompensated Volume Total, Heat Total or Mass Total. Pulse Output Form (menu selectable): Open Collector NPN or 24 VDC voltage pulse Nominal On Voltage: 24 VDC Maximum Sink Current: 25 ma Maximum Source Current: 25 ma Maximum Off Voltage: 30 VDC Saturation Voltage: 0.4 VDC Pulse Duration: User selectable Pulse output buffer: 8 bit Fault Protection Reverse polarity: Shunt Diodes Over-current Protected Over-voltage Protected Real Time Clock The Flow Computer is equipped with a battery backed non-volatile real time clock with display of time and date. Format: 24 hour format for time Day, Month, Year for date Listing: CE Compliant, UL, C-UL Pending Serial Communication The serial port can be used for printing, datalogging, modem connection and communication with a computer. Power is provided for KEP s MPP2400N (modem) communication accessory. RS-232: Device ID: 01-99 Baud Rates: 300, 1200, 2400, 9600 Parity: None, Odd, Even Handshaking: None, Software, Hardware Print Setup: Configurable print list and formatting, Compatible with external dataloggers. RS-485: Device ID: 01-247 Baud Rates: 300, 1200, 2400, 4800, 9600, 19200 Parity: None, Odd, Even Protocol: Modbus RTU (Half Duplex)

Internal Multi-protocol Communication Card Option FEATURES Internal communication card eliminates the need for external protocol converters. Supports: BACnet IP, BACnet MS/TP, Metasys N2, Modbus TCP, AB Ethernet IP, AB DF1, LonWorks* Easy to configure via the Web Interface. Dedicated internal LonWorks is also available Dedicated internal RS485 Modbus RTU is also available DESCRIPTION The multi-protocol communication card is an internal, high performance, Building Management System communication solution for the ST2 flow computer family. The card provides an instant interface, enabling the KEP flow computers to communicate with multiple BMS protocols, including: BACnet MS/TP BACnet IP Modbus TCP Metasys N2 AB DF1 AB EtherNet/IP LonWorks* CONFIGURATION Use a web browser to locate the internal web page and configure the settings. The detailed settings vary with the different communication protocols. Only one communication port/protocol can be used. A web browser is also used to configure the site specific settings for each instrument Fig 1 Top view of multi-protocol card installed on ES762 mother board Quad Digital Input (ES762 only) RS-232 Ethernet RS-485 Fig 2 Rear view of ES762 case. Communication ports are available for RS-485 and Ethernet * LonWorks protocol requires a different module assembly from the other available protocols. LonWorks is not field selectable.

Configuration Parameters 1 Submit 50000 Submit 47808 Submit COV_Disable Submit - Submit Remove Add Sample screen shot of web interface configuration

Standard Dimensions Terminal Designations 3.43 (87) START STOP 0.28 (7.2) TOTA 1 GRAND 6 RATE 2 SCROLL 7 5.67 (144) RATE 147.43 TOTA 267395.749 PRE 1 3 PRE 2 8 TEMP 4 DENS 9 6.18 (157) PRINT 5 TIME 0 Dotted Line Shows Optional Bezel Kit GP M CLEAR HELP 2.83 (72) 6.15 (156) 0.5 (13) MENU ENTER FLOW IN Vin (+) Iin (+) AUX - 3 DC OUTPUT PULSE IN Iin (+) - - - - - - - - - - TEMPERATURE IN Iin (+) COMMON RTD EXCIT (+) RTD SENS (+) RTD SENS (-) Iin (+) AUX - 4 PRESSURE (TEMP 2) Iin (+) IN RTD EXCIT (+) RTD SENS (+) RTD SENS (-) PULSE OUTPUT (+) PULSE OUTPUT (-) ANALOG OUTPUT 1 (+) ANALOG OUTPUT 2 (+) ANALOG OUTPUT COMMON (-) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RLY1 RLY2 17 NO 18 COM 19 NC 20 NC 21 COM 22 NO POWER IN DC (+) DC (-) AC LINE AC LINE 23 24 Terminal Layout 0.4 (10) 5.43 (138) Panel Cutout Dimensions are in inches (mm) Wall Mount ( W mounting option) Dimensions 7.3 (184) 2.34 (59.5) 0.75 (19) 9.4 (238) 8.4 (213.4) 1.06 1.10 1.10 1.10 1.10 (27) (28) (28) (28) (28) 0.472 (12) 0.59 (15) Security Tag Provisions 5.7 (145) 0.385 (9.8) 2.68 (68) 4.13 (105) 2.33 (59) 0.75 Conduit Knockouts (5 places) 1.10 1.10 1.10 1.10 (28) (28) (28) (28) 7.8 (198) 0.63 (16) CN-2 TB-3 TB-4 optional optional DB-9 5 4 3 2 1 9 8 7 6 RS-232 TB-1 1 2 3 4 5 6 Quad Digital Input 1 2 3 4 RS-485 1 2 3 4 5 6 7 8 9 10111213141516 171819202122 2324 Main Terminal Block Ordering Information Ex: ES762ST2 L 1 1 P 13 TB QDI Series: ES762ST2 = Utility Metering Flow Computer Display Type: L= LCD O= OLED V= VFD Input Type: 1= 85 to 276 VAC 3= 24 VDC (16 to 48 VDC) Network Card: 1= RS485/Modbus (standard) 3= COM CARD with Multi-Protocol Specify protocol (example: 3 BAC/IP) BAC/IP = BACnet IP BACMS/TP = BACnet MS/TP MOD/IP = Modbus TCP/IP METASYS/N2 = Metasys N2 ABDF1 = AB DF1 ABETH/IP = AB EtherNet/IP 4= COM CARD with LonWorks Protocol Specify protocol (example: 4 LONWORKS) Factory configuration of network card settings Mounting: P= Panel Mount *N= NEMA 4 Wall Mount (see NEMAtrol & MS811) *W= NEMA 12/13 Wall Mount w/ Clear Cover Options: 13 = Superchip; 2 relay, Positive heat only (standard) TB= RS485 Terminal Block standard for Panel Mount (P) and NEMA4 Wall (N) Mounting Styles QDI=Quad Digital Input Accessories: OPC/DDE Server for RS232 Port available, see EX5-UCOND-NA00 OPC/DDE Server for Modbus Suite available, see EX5-MDBUS-NA00 Modem Available, see MPP-56KN and MPP-2400N Serial printer available, see P20, P220, P295 Ethernet Port Server available, see IEPS Ethernet Port Server Modbus TCP available, see ADAM4572 RS-422/485 to RS-232 Communication Adapter available, see CA285 RS232 Extender Cable: P/N=13220-<length in inches>