GE Intelligent Platforms PAC8000 RTU

Similar documents
MTL8000-2/x Series Modular I/O

GE Intelligent Platforms. Wellhead RTU Solutions

Achieving Optimal Returns from Wellhead Operations

GE Intelligent Platforms. High-Performance Automation Solutions for a Connected World

PAC8000 Hybrid controller (8521-

Oil & Gas. GE Fanuc Intelligent Platforms

Ovation Compact Controller

Madrid, 25 y 26 de mayo de 2015 ABB Automation Days Wireless Instrumentation

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

WIRELESS REMOTE ASSET MONITORING & CONTROL

Intrinsically Safe Temperature Concentrator System

General. Remote I/O A4/1.

PAC BI-DP BIM and 8701-CA-BI Carrier

Modicon M580 MUCH MORE than a PLC. the first epac!

GE Intelligent Platforms

Control IT S800 I/O System

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

Unlock the full potential of your automation architecture.

QUALITROL QTMS Transformer Monitoring System

Providing the missing piece in your Condition Based Monitoring platform

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

HART Products. ICP Electronics Australia Pty Ltd Overview P 6-1

S900 Remote I/O System Intrinsic safety in the field ABB

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

How Emerson s I/O on Demand Is Changing the Automation Infrastructure

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

New concept in automation: epac. November 2015

Automation systems. Scalable performance for every requirement

M-series Intrinsically Safe I/O

ControlEdge RTU Process Controller Product Information Note

Sustain.Ability Honeywell Users Group EMEA. Adriano Canale How Universal I/O Can Help Save Design Cost and Project Execution Time

M-series MQ Controller

Product Specifications

M-series Profibus DP Series 2 Plus Interface Card

remote I/O future inside

Innovation for system integration

Unlock the full potential of your automation architecture. Automation control solutions based on Modicon Quantum Ethernet I/O

Electrical Demand Specification (Reference SOP: )

MicroNet TMR Control System

Remote monitoring and display solutions

Modicon M580 The World First epac

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

Scout-S Station Controller

M-series Profibus DP Series 2 Plus Interface Card

M-series MQ Controller

DeltaV SD Plus Controller

FOUNDATION Fieldbus Fieldbus Basics

M-series MX Controller

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

S-series Profibus DP Interface Card

Recorders for all applications

ELECTRONIC AND CONTROL PROCESS DEVICES. reliability. professionalism. Company Profile.

POINT I/O Family. Chapter. Overview

Tracy Dye, CPAC Rome, March 21 24, Miniature Sample Handling and Analytical Techniques Workshop NeSSI Generation 2

expertise beyond controls Vanguard Series 5

Solutions for Oil and Gas

remote I/O future inside

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

Your Global Automation Partner. The Full Range for Industrial Ethernet

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

Ovation Ethernet Link Controller Module Data Sheet

M-System s. 17 years of successful sales, 480,000 total units sold! selectable. Mixed Signal. Mixed Signal. Compact, Mixed Signal

Connect Different Protocols It s Quick, Easy, and Reliable

Breaking the Limits of Analog Technology. Key attributes of the technology that makes FOUNDATION fieldbus suitable for process control

Ethernet Network Redundancy in SCADA and real-time Automation Platforms.

Wireless Field Data Backhaul

DeltaV Safety Instrumented System (SIS) with Electronic Marshalling

Summit Virtual Chassis Design and Installation Guide

Backplane. Allen-Bradley. System integration. Backplane

SICAM AK 3. Flexible automation for all applications. Automation, telecontrol and communication for large data volume.

M-series DeltaV Controller Interface for PROVOX I/O

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Automation, Ethernet & Wireless Solutions

Compact Control Builder AC 800M and S800 I/O ABB

Partnering for Success. Pepperl+Fuchs and Honeywell Enhancing Performance and Transparency

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

5OOO Series. Expansion & Communication Modules. Product Selection Guide. Expansion. Communication CONTROL MICROSYSTEMS

How to choose an Industrial Automation Controller: White Paper, Title Page WHITE PAPER. How to choose an Industrial Automation Controller

Eagle Logic Solver (ELS) SPECIFICATION DATA SIL-2 Rated Fire & Gas System

Series Specialty PLCs

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Ruchiman Priatna (Control Technology) Freelance The easy-to-use distributed control system

S-Series DeltaV Controller Interface for PROVOX I/O

Pipeline Unit/Station Control. Combining Unit and Station Control into Siemens PCS 7. Application Brief

Joe Bastone 27 September EXPERION PKS ORION The Future of Automation is Here

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

Foundation Fieldbus optimized for FPSO - CAPEX. Jonas Berge, Emerson Process Management

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

Introduction to RTU Controllers

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

HART Temperature Transmitter for up to SIL 2 applications

M-series Foundation Fieldbus I/O

Transcription:

GE Intelligent Platforms PAC8000 RTU

A ruggedized, reliable RTU PAC8000 Remote Terminal Unit (RTU) thrives in the desert heat of the Arabian Peninsula and the arctic cold of Siberian oil fields delivering quality, reliability and safety for your success. With increasing pressure to improve operational performance, meet environmental specifications and overcome rising energy costs, oil and gas operations must efficiently and securely monitor and control entire processes across local and remote locations. You need a partner that understands your business and can deliver the expertise and capabilities to drive results. The PAC8000 RTU solution from GE Intelligent Platforms enables you to easily monitor, diagnose and maintain your utility assets even in the most hazardous environments. Access to timely and accurate mission-critical information from fixed assets such as oil and gas wells, compressor stations, pipelines, fluid storage tanks and utility meters, can eliminate critical gaps in your oil and gas operations, resulting in higher productivity and long-term growth. Benefits Designed by experienced process engineers, PAC8000 RTU is simple to use and delivers significant cost savings and value: Tough environmental specifications from 40 to +70 degrees Celsius continuous operation; 10 years of service in Class G3 corrosive environments Inherent reliability - redundant CPU, power supplies, communications Easy maintainability - hot replacement and automatic configuration Integrated intrinsic safety (optional) Integrate optionally with SafetyNet TUV certified to SIL 2 Scalability from 8 to 1024 I/O Extensive diagnostics for remote health monitoring Minimum cost field mounting Low cost of ownership PAC8000 RTU

Ensuring continuous operations In the unlikely event of failure, PAC8000 RTU maintains your operations with robust redundancy capabilities and flexible communications options. Firmware updates In keeping with its ability to maintain operations on a continuous basis, a redundant PAC8000 RTU can receive a firmware upgrade. Controller redundancy Redundant controllers can be used for critical applications whereby the redundant controller pair operates in parallel, checking status multiple times through the processing loop and enabling the backup controller to continuously monitor the health of the Master controller. It ensures a rapid and bumpless transfer to the standby controller. Network redundancy PAC8000 RTU has two high-speed Ethernet ports to provide communication security. Each port can be connected to an independent LAN, which is continuously monitored for its integrity. If the primary port detects a network failure, traffic is immediately switched to the other LAN to maintain full communication. Communication protocols DNP3 over Ethernet Modbus TCP over Ethernet Modbus RTU Serial Each controller has two serial ports that can be configured as a Modbus Master to control and obtain information from Modbus Slaves. The serial ports can also be configured as a Modbus Slave, accepting write commands from Modbus Master devices and providing information on its data registers. Executable programs The control programs are held in nonvolatile memory and can be restored automatically after power cycling of the controller. A new control program can be downloaded to a controller while the existing program is still operating. When the download is complete, the controller will automatically switch to the new control program without interruption to the operation of the plant. Failsafe and automatic cold start The RTU supports fault tolerant communications to the Control Room SCADA; however, in the unlikely event that the communications are lost, the RTU can either continue to operate autonomously or adopt a user-defined safe state. If the RTU continues to operate, data will be logged for transmission once communications have been restored. In the event of power loss, it will perform a cold restart, which restores the program(s) and assumes a predefined status. Controllers can also be configured to perform a warm start if RTU power is temporarily lost during a brownout. www.ge-ip.com/pac8000rtu

Powerful features With PAC8000 RTU, you can meet demanding oil and gas applications while gaining a sustainable competitive advantage. PAC8000 RTU in your system PAC8000 RTU is designed for use in the harshest environments, operating over a temperature range of -40ºC to +70ºC, and it is resistant to 30g shock, 5g vibration and G3 corrosive environments. Each PAC8000 RTU controller node can address up to 64 I/O modules, which, depending upon the number of channels per module, can provide up to 1024 I/O points at a single node! A node can consist of a mixture of analog and discrete modules providing maximum flexibility to system designers. HART passthrough PAC8000 RTU can pass smart HART information from field devices to a distant PC workstation, allowing you to readily interface to asset management software applications to remotely manage the HART information contained in your HART-based field instruments. Hazardous area operation PAC8000 RTU is designed to operate in Class I, Division 2 and Zone 2 hazardous areas and can control I/O modules that have field wiring extending into the more hazardous Division 1, Zone 1 and Zone 0 areas. I/O modules I/O modules transfer signals to and from field instruments. Input modules receive signals from transmitters and sensors and convert them into a digital form for presentation to the controller, while output modules receive commands from the controller and transfer them to actuators. There are a wide range of modules, including types for low-level instrumentation, AC mains and intrinsically safe signals. I/O modules typically have 4, 8 or 16 field channels. A small footprint with a packing density of 3-6mm per channel allows for installations where space is a premium. Field terminals Field terminals provide the interface between the I/O modules and the field wiring, including fusing and loop-disconnect as options. A mechanical keying system prevents an I/O module from being inadvertently connected to the wrong type of field terminal. Mounting onto the module carrier, one to each I/O module, field terminals are clamped firmly by the I/O module to form an electrical and mechanical assembly of high integrity and may be replaced in service without removing carriers or disturbing the operation of other modules.

Carriers Carriers form the RTU s physical and electrical backbone by providing a mounting to support and interconnect the controller, power supplies, I/O modules and field terminals, and carry the address, data and power lines of the internal Railbus. They provide termination points for the LAN and field wiring cable shields and can also distribute bussed field power to the I/O modules; I/O module carriers are available to support four or eight I/O modules. System power supplies System power supplies are available for the node to convert local AC or DC supplies to power the node and provide field power for I/O modules. Power supplies can be optionally redundant and any failures are flagged. GE s innovative bussed field power scheme for distributing field power avoids complex wiring at the field terminal and minimizes the carrier wiring. Affordable intrinsic safety Our expertise is built into the front end of IS I/O modules for direct connection to hazardous area field wiring. This means no external barriers or isolators, no additional wiring and no extra cost. All you pay for is the integrated IS I/O module. Integrated power supplies Power for IS I/O modules is derived from integrated, modular power supply units, which can each supply between 8 and 20 I/O modules, depending on the I/O type and mix. Optional power supply redundancy is supported by means of an additional, redundant supply unit connected in an n+1 arrangement. In applications with mixed IS and non-is field wiring, the full facilities of the bussed field power regime are retained for the non-is part of the system. In nodes populated only with IS I/O modules, a separate system power supply module provides power for the Bus Interface Module and node services with redundancy capabilities. Versatility and tough design to meet your process I/O needs Oil and gas PAC8000 RTU is designed for the most remote places where oil and gas are found, and its wide temperature range means that it can be mounted outdoors on the plant anywhere in the world. Using redundant power supplies and network cables can increase system availability in these conditions further. Natural gas pipelines When I/O is installed in remote locations, it needs to be reliable and simple to maintain. PAC8000 RTU s I/O modules can be hotswapped on a live system. The configuration is backed up locally so no re-configuration is necessary even if several modules are removed and replaced at the same time. For more information about how PAC8000 RTU can deliver results for your business, visit www.ge-ip.com/pac8000rtu

PAC8000 RTU At the heart of PAC8000 RTU is a powerful, robust controller for advanced control strategies. Controllers Controls up to 64 sixteen-channel modules Redundant controllers with dual redundant Ethernet connections Wide range of protocols including Modbus over Ethernet Regulatory and IEC-61131-3 software execute concurrently providing both process and discrete control On-line configuration and reconfiguration I/O Modules Wide range of I/O for virtually any process signal, including HART Smart analog, thermocouple, RTD, potentiometer, high-speed counter, frequency and quadrature Suitable for safe-area, non-incendive and intrinsically safe applications Remote configuration and interrogation of smart devices Packing density: 3-6mm per channel Live hot swapping Keying stops modules from being fitted in the wrong position Isolation between I/O bus and field wiring Diagnostic services for each channel

Power Supplies (not shown) AC power or 24V dc input versions Supplies power for I/O and controllers Redundant power supply options Bus Interface Modules (not shown) Connects up to 32 sixteen-channel modules Carriers Tough polycarbonate base protects against shock and vibration Choice of four module, eight module and Node Services versions Cable ground and shield terminals along front edge Reliable no active components so there is nothing to fail Replacement modules are configured automatically, so maintenance is simplicity itself Field Terminals Unique, removable terminals for fast wiring and field replacement Optional fuses and disconnects no interposing terminals required Direct termination for field wiring Field power routed to terminals no daisy chaining at the field terminals Integral tagging system

GE Intelligent Platforms Contact Information Americas: 1 800 433 2682 or 1 434 978 5100 Global regional phone numbers are listed by location on our web site at www.ge-ip.com/contact www.ge-ip.com/pac8000rtu 2010 GE Intelligent Platforms, Inc. All rights reserved. *Trademark of GE Intelligent Platforms, Inc. All other brands or names are property of their respective holders. 10.10 GFA-1149B