SCADAPack 530E 535E. remote Programmable Automation Controller

Similar documents
SCADAPack 350E 357E. Smart Remote Terminal Unit

SCADAPack 312E 313E 314E

SCADAPack 330E 333E 334E 337E

SCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com

SCADAPack 312E 313E. Smart RTUs for water

SCADAPack Smart RTU

SCADAPack ES. Smart RTU

SCADAPack ES. Smart RTU

SCADAPack 32. Smart RTU

SCADAPack 330E 334E. Smart RTU

5502 Differential Analog Input Module

5403 and 5404 Digital Input Modules

SCADAPack 50. Wireless Remote Data Logger

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

SCADAPack. I/O Expansion & Communication Modules

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CONTROL MICROSYSTEMS Input/Output (I/O) Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

CONTROL MICROSYSTEMS and 5601A Input/Output (I/O) Module. Hardware Manual

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

TM241CE24T controller M IO transistor PNP Ethernet

SCADAPack E 5405 Digital Input Hardware Manual

General information. Display. Supply voltage. Input current

TM241CE24U controller M IO transistor NPN Ethernet

CONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

General information. Display. Supply voltage. Input current

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

TM241CE40R controller M IO relay Ethernet

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

TM241CE24T controller M IO transistor PNP Ethernet

TM258LF42DT compact base M I/O - 24 V DC - CANopen

General information. Display. Supply voltage

TM241CE40T controller M IO transistor PNP Ethernet

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM241CE40R controller M IO relay Ethernet

General information. Display. Supply voltage

TM221M16R controller M IO relay

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current

SCADAPack E Input/Output Module Hardware Manual. Version: Date: August 2017

TM258LD42DT4L compact base M I/O - 24 V DC

TM241CE40R controller M IO relay Ethernet

TM258LD42DT4L compact base M I/O - 24 V DC

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

iologik E1200H Series

SCADAPack Modbus multivariable transmitter

General information. Display. Supply voltage. Input current

TM241CEC24R controller M IO relay Ethernet CAN master

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

General information. Display. Supply voltage

TM251MESC controller M251 Ethernet CAN

SCADAPack E I/O Module Hardware Manual (337E Only) Version: Date: August 2017

RTU32S RTU32S Series Small Compact Utility RTU

TM221CE40R controller M IO relay Ethernet

RTU32S RTU32S Series Small Compact Utility RTU

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Features and Benefits. Certifications

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

SCADAPack FlowStation 110. Pump station controller

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

TM241C40U controller M IO transistor NPN

TM221ME32TK controller M IO transistor PNP Ethernet

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

Features and Benefits. Certifications

Trio Q. Licensed UHF Ethernet and Serial data radio. QR450 Half Duplex

TM241C24T controller M IO transistor PNP

iologik 2500 HSPA/GPRS/WLAN Series

TM241CE24T controller M IO transistor PNP Ethernet

NTX Series Product Comparison

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SCADAPack E Input/Output Module Hardware Manual. Version: March 2016

TM221CE40R controller M IO relay Ethernet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

CONTROL MICROSYSTEMS. SCADAPack 100 Controller. Hardware Manual

TM221M32TK controller M IO transistor PNP

5OOO Series. Expansion & Communication Modules. Product Selection Guide. Expansion. Communication CONTROL MICROSYSTEMS

Features and Benefits. Certifications

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

TM221CE24R controller M IO relay Ethernet

LMC058LF42 compact base - 42 I/O - 24 V DC supply

CONTROL MICROSYSTEMS. TeleSAFE Micro16 Controller. Hardware Manual

TM241C40R controller M IO relay

General information. Display. Supply voltage. Input current

TM241CE40R controller M IO relay Ethernet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM221M16TG controller M IO transistor PNP spring

FEATURES DESCRIPTION FEATURES

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Transcription:

SCADAPack 530E 535E remote Programmable Automation Controller

1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet presents the first two models of that new range, the SCADAPack 530E and the SCADAPack 535E. The ARC Advisory Group has defined the rpac as a whole new way to look at remote site automation. An rpac combines the power of a PAC with the versatility of an RTU. The SCADAPack 500E rpac is a platform that dramatically increases performance (execution speed, connectivity, number of remote/ local I/O), adheres to open standards, and can operate in the harsh demands of a remote environment. SCADAPack 500E provides: Open standard telemetry protocols such as DNP3 level 4 with Security Suite (Secure Authentication and/or Data Encryption) and IEC 60870-5-101/-104 Open standard industrial protocols such as Modbus RTU, Modbus TCP and DF1 Open standard IEC 61131-3 programming environment Data concentrator for any DNP3, Modbus or DF1 devices Up to 29 active SCADA masters, up to 100 remote/local slave devices and up to 100 remote DNP3 devices in peer-to-peer mode Remote management suite (ability to amend configuration, modify programs and update firmware remotely, using open standard DNP3) Up to 515 internal digital/analog inputs/outputs 1ms resolution time-stamped digital inputs, 30ms sampled analog inputs with 16-bit ADC 3 Ethernet and 4 Serial ports, 1 embedded 3G modem, 1 USB device port for configuration 1 USB host port for external storage (memory stick up to 32GB) Tool-free DIN rail mounting system Withstands 15g acceleration IP2x terminal blocks Operation from 40 to +70 C ( 40 to +158 F) Compact form factor

Specifications 2 Controller Processor Memory Event Logging Capacity (events) Database Capacity (points) Data Concentrator capacity (points) Data Concentrator capacity (devices) File System Typical Storage Communications Serial Ports: Serial1, Serial2 Serial Ports: Serial3, Serial4 Embedded Wireless Serial Protocols Ethernet Ports: Eth1, Eth2, Eth3 IP Protocols Master - Slave capability USB Device USB Host General Logic control General characteristics SPEAr 1380 32-bit dual-core Cortex A9 microcontroller, up to 600MHz 128MB NAND FLASH, 128MB DDR3 RAM Non-Volatile RAM CMOS SRAM with lithium battery retains contents for 2 years with no power 40,000 (this number decreases if the database is greater than 10,000 points) Up to 20,000 (this number decreases if the event pool is above 7,000 events) Approximately 15,000 Approximately 100 Internal: 10 MB; External: 32 GB (on optional memory stick) RS-232 port, 8-pin modular RJ45 jack, full or half duplex with RTS/CTS control and operator interface power control, supports baud rates up to 115,200 bps. Rated to ±15kV (IEC 61000-4-2, Air Discharge) static protection RS-232 port, 8-pin modular RJ45 jack, full or half duplex, or RS-485 port, 2-wire, half-duplex, supports baud rates up to 115,200 bps In RS-232 mode, rated to ±15kV (IEC 61000-4-2, Air Discharge) static protection The controller board is fitted with Socket Modem support, for future use DNP3 level 4 slave/master and peer-to-peer, IEC 60870-5-101 slave, Modbus slave/master, DF1 master 8-pin modular RJ45 jack, 10/100 Mbps UTP (10/100Base-T), transformer isolated DNP3 level 4 in TCP Master/Slave, UDP Master/Slave and peer-to-peer, IEC 60870-5-104 Slave, Modbus/TCP Server, Modbus/TCP Client, Modbus RTU in TCP Client NTP Client/Server, Telnet Server, FTP Server, BOOTP Server, Can simultaneously report to up to 29 independent masters (3 in DNP3, 2 in IEC 60870-5-5-101/104, 20 in Modbus TCP and 4 in Modbus RTU ) and connect to up to 100 remote devices in DNP3 peer-to-peer. As a data concentrator it can manage up to 100 local or remote DNP3 slaves, and up to 100 local slaves communicating with Modbus RTU, Modbus TCP or DF1 serial. USB 2.0 compliant B -type receptacle, for local configuration USB 2.0 compliant A -type receptacle, supports USB devices up to 32GB (specific memory sticks supported) IEC 61131-3 SCADAPack Workbench programming suite (LD, ST, FBD & SFC) I/O terminations Dimensions Packaging Environment SCADAPack 530E: 11-pole connector, 0.0810...3.31mm 2 (28...12 AWG), solid or stranded SCADAPack 535E: 5, 6, 7, 9, 11-pole connectors, 0.0810...3.31mm 2 (28...12 AWG), solid or stranded SCADAPack 530E: 150.5mm (5.93 ) wide, 134.8mm (5.31 ) high, 74.9mm (2.95 ) deep SCADAPack 535E: 150.5mm (5.93 ) wide, 182.3mm (7.18 ) high, 86.5mm (3.41 ) deep Corrosion resistant zinc-plated steel with black enamel paint -40 C (-40 F) to 70 C (158 F) operating, -40 C (-40 F) to 85 C (185 F) storage 5% RH to 95% RH, non-condensing Shock & Vibration IEC 60068-2-27 (tested up to 15g), IEC 60068-2-6 Warranty 3 years on parts and labor

Specifications 3 Power Supply Rated Voltage General characteristics 12...30 Vdc, 5W typical. Limit voltage: 11.5...32 Vdc; turn on voltage: 10...11.5 Vdc; turn off voltage: 9...10 Vdc Maximum Power SP530E + 4 x 6601 expansion IO modules + USB: 8.7W Power Requirements SP530E (Controller) 3.7 W SP535E (Controller with integrated IO) 4.8 W 6601 (Expansion IO) 1.1 W USB (5V at 100mA) 0.6 W Serial port (5V at 250mA) 1.5 W For analog output power requirements see the Analog Output specifications. Certifications EMC and radio frequency Voltage input General safety UL 508 Power Consumption (W) 530E 535E 535E + 6601 535E + 2 x 6601 535E + 3 x 6601 11.5V 3.0 4.1 5.2 6.3 7.4 13.8V 3.0 4.1 5.2 6.3 7.4 24V 3.4 4.5 5.6 6.7 7.8 30V 3.7 4.8 5.9 7.0 8.1 FCC 47 CFR Part 15, Subpart B ICES-003 Issue 5 August 2012 CE and RCM markings Hazardous locations ccsaus Non incendive Electrical Equipment for use in Class I, Division 2, Groups A, B, C and D IECEx/ATEX Class I, Zone 2

Specifications 4 Controller board (530E and 535E) Digital Inputs Digital Output Digital and Analog Inputs/Outputs 2, 12 24 Vdc Turn on voltage: 8 Vdc (minimum), Turn off voltage: 4 Vdc (maximum) Over-voltage tolerance: 150% sustained over-voltage without foreseeable damage DC input current: 0.4 ma at 12 Vdc, 0.8 ma at 24 Vdc Time stamping: 10 ms Ground return connected to Chassis Ground 1, Sinking MOSFET output, rated 30V, 0.5A, ground return connected to Chassis Ground Internal power monitor Power input - analog input and low indication, onboard lithium battery - low indication Internal temperature monitor Controller temperature range -40 C +75 C (-40 F...+167 F) I/O board (535E and 6601 standalone module) Analog Inputs 6, dipswitch-configurable to 4...20 ma, 0...20 ma, 1...5 V, or 0...5 V Uni-polar, differential, voltage or current Resolution: 24-bit ADC (16-bit over the measurement range) Accuracy: ±0.1% of full scale at 25 C (77 F), ±0.2% over temperature range Isolation: 250 Vac isolation from channel to channel and from rpac logic and chassis Input Resistance: 250 Ω or 800 kω in current/voltage configurations Under range: 4...20 ma measures to 0 ma Common Mode Rejection: -80dB (50/60Hz) 30 ms sampling rate Analog Outputs 2 (optional), 0...20 ma, 4...20 ma, voltage output may be accomplished with external precision resistor Uni-polar Resolution: 12-bit over 0...20 ma range Accuracy: ±0.15% at 25 C, ±0.35% of full scale over temperature range Response Time: less than 10 µs for 10% to 90% signal change Power Supply: 12 30 Vdc, external Power (Current) Requirements: 10 ma plus up to 20 ma per output Isolation: transformer, 500 Vdc maximum to RTU logic and chassis Load Range: 12 Vdc: 0 475Ω, 24 Vdc: 0 1075Ω, 30 Vdc: 250 1375Ω Logic End-Of- Scan to Signal Update Latency: less than 10 ms (typically 5...8 ms) Status & Reporting: Open Loop status, output value poll Controls: Direct Operate, Select Before Operate Digital Inputs 16, 12 24 Vdc Turn on voltage: 9 Vdc (minimum), Turn off voltage: 4 Vdc (maximum) Over-voltage tolerance: 150% sustained over-voltage without foreseeable damage DC input current: 0.9 1.2 ma at 12 Vdc, 2.1 2.4 ma at 24 Vdc Time stamping: 1 ms Sequence of Events Isolation: in 2 groups of 8. Isolation from RTU logic and chassis: 1000Vac/1500Vdc Digital Outputs 8, relays (2 Form C, 6 Form A) Form C: SPDT, separate Normally Open/Normally Closed/Common Form A: Normally open, one common Isolation: 500 Vac minimum to RTU logic Maximum Switching Voltage: 30 Vdc or 25 Vac Maximum Switching Load: 60 W or 50 VA (2A) Status & Reporting: Individual relay pole feedback to software, output state poll Controls: Direct Operate, Select Before Operate, Trip/Close, Latch, Pulse Counter Inputs 8, shared with digital input channels 1 to 4: 0 1.5kHz, 5 to 8: 0 150Hz. Additional I/O I/O Expansion Supported modules: 6601 external module Maximum number of modules per unit: SCADAPack 530E: 16 (*) SCADAPack 535E: 15 (*) (*): to reach this limit, additional power supply modules are required

Model 5 SCADAPack 530E/535E Model TBUP530 TBUP535 E A B C D Select: Controller SCADAPack530E, 32-bit controller, Dual Core SCADAPack535E, 32-bit controller, Dual Core, comes with additional I/O Select: Platform SCADAPack E Firmware (Configuration Software included), executes two IEC 61131 kernels, Workbench required Select: SCADA Security None AGA-12 Encryption for DNP3 (Security Administrator application required) DNP3 Secure Authentication SAv2 (Security Administrator application required) DNP3 Secure Authentication with AGA-12 (Security Administrator application required) Select: Protocol Option 5 DNP3 Serial/IP mstr/slave/peer-to-peer, IEC 60870-5-101/104 Slave, Modbus RTU/TCP mstr/slave, TCP/IP, DF1 mstr Select: License Option 6 Full DNP3 Data Concentrator License, Multiple DNP3 Master License (up to 3 Masters) A Select: Analog Inputs P530: None P535: adds 6, shipped selectable as 0-20mA or 4-20mA B P535 only: adds 6, shipped selectable as 0-5V or 1-5V A Select: Digital Inputs/Outputs P530: 2 Digital Inputs (12/24V), 1 Digital Output (open collector) B P535: 16 Digital Inputs (12/24V) and 8 Dry Contact Relay outputs (6 Form A, 2 Form C) 0 None Select: Analog Outputs 1 P535 only: 2 channel Analog Output option, shipped selectable as 0-20 ma or 4-20mA, external DC supply 0 None S U Select: Integrated Communication Interfaces Select: Certifications With FCC, UL508, CE marking and RCM Adds ccsaus Nonincendive Electrical Equipment for use in Class I, Division 2, Groups A, B, C and D X Adds IECEx/ATEX Class I, Zone 2 I/O Expansion Modules (Supported by SCADAPack 530 & 535 Controllers only) Part No. TBUX297583 TBUX297584 TBUX297585 TBUX297586 I/O expansion and distributed architecture Expansion Modules (complete the following part numbers with S, U or X depending on certification required) Model 6601-20mA, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/4-20mA) Model 6601-5V, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/1-5V) Model 6601-20mA, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/4-20mA), 2 A/O (external DC supply) Model 6601-5V, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/1-5V), 2 A/O (external DC supply) 1. Depending on the options chosen (with or without the future socket modem), SCADAPack 535E embedded DC supply can power either two (2) or four (4) 6601 IO expansion modules. When more 6601 IO expansion modules are required in any of these two configurations, then it is necessary to use one of our power supply extensions (one unit can power up to 8x 6601 modules). 2. SCADAPack 535E can be used as a Remote I/O master, managing up to 15 SCADAPack ES slave units: SCADAPack 535E automatically downloads the corresponding configuration into these slave devices (which is very useful when replacing devices, as the operator does not have to do any firmware setting). Schneider Electric Telemetry & Remote SCADA Solutions 415 Legget Drive, Suite 101, Kanata, Ontario K2K 3R1 Canada Direct Worldwide: 1 (613) 591-1943 Fax: 1 (613) 591-1022 Toll Free within North America: 1 (888) 267-2232 www.schneider-electric.com 2014 Schneider Electric. All Rights Reserved. Schneider Electric is a trademark and property of Schneider Electric SE, its subsidiaries and affiliated companies. All other trademarks are the property of their respective owners - September 2014 Part Number TBULM08038-04 v028 Document number 0100BR1432