Series ST. User s Guide DIGITAL TORQUE TOOL TESTERS. .com. Series ST Torque Tool Testers. User s Guide

Similar documents
Series STA DIGITAL TORQUE TOOL TESTERS. User s Guide

User s Guide. Series CT CLOSURE TORQUE TESTER. User s Guide

Series CTA CAP TORQUE TESTERS. User s Guide

Digital Controllers Series DC MODEL DC4010 / ESMH-DC MODEL DC4020 / ESM-DC MODEL DC4030 / TSFM500-DC MODEL DC4040 / TSTM-DC.

MESURgauge Software. User s Guide

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

SMART FORCE AND TORQUE SENSORS. User s Guide

SMART FORCE AND TORQUE SENSORS. User s Guide

User s Guide. Model PTA PLUG & TEST TM ADAPTER

Premium Digital Force Gauges

Digital Torque Tester

HHTQ35 Digital Torque Gauges

DTT Series Digital Torque Testers User Manual

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide

Digital Torque Screwdriver

DTT-L Series Digital Torque Testers User Manual

Model 3i DIGITAL FORCE / TORQUE INDICATOR. User s Guide

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

Digital Torque Tester/Wrench

Digital Torque Wrenches

User s Guide. Series 2 DIGITAL FORCE GAUGES

User s Guide. Series TT02 TORQUE TOOL TESTERS

NOTES TABLE OF CONTENTS

PC 150. Digital Bench Scale. Operation Manual

TTC Series Torque Tool Tester Operation Manual

Digital Force Gauge INSTRUCTION MANUAL. Model: DS2

Model 8702 DP-CALC Micromanometer

3 Input Multiplexer Operation Manual

AWS-3000 Torque Display

Universal Force / Torque Gauge

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

CONTENTS CONTENTS AWS-4050 Guide

FA-2448 SIX POSITION Filter Wheel

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

MPT-250A SPECIFICATIONS AND OPERATING INSTRUCTIONS

Digital Measurement Metrology, Inc PRECISION IS OUR VISION

AWS-QC Torque Tester

Exposure Monitoring. Model 8560 INSPECTAIR CO 2. Meter. Operation and Service Manual , Revision B June 2006

PIM-Mini Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual

User s Guide. Series 3 DIGITAL FORCE GAUGES

FNet Repeater Installation & Operator s Instruction Manual

Series ST-H01-25 DIGITAL CAP TORQUE TESTERS. User s Guide

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10

AirPro Surveyor 2 Manual

INDEX WARRANTY CALIBRATION Checking Calibration 7.20 Field Calibration Adjustment 7.30 Special Calibraton

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

MTMDP Torque Display With Multiple Internal Transducers

Shop Fox Fence Kit Installation Instructions:

PC-150. DIGITAL BENCH SCALE Setup / Operation Manual

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

MTS-2000 USER S MANUAL

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

DICKSON MP100 DICKSON. Operation Manual. Applications. Product. Specifications. Product. Contents:

Analog Interface Unit Operation Manual

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

Biesemeyer Fence Kit Installation Instructions:

AUTOMATION. Operator s Manual PG10. Full Access. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications

Card Encoder. PC Software. User Manual Software OPW Fuel Management Systems Manual No. M Rev 2

1:4 DVI Splitter EXT-DVI-144N

ADW Series Torque Wrench Users Guide for Basic Model with Memory

MESURgauge Software. User s Guide

PRO Owner's Manual

CA-A480-A Elevator Controller. Reference & Installation Manual

DPN-4 Duo. User Manual. 4-Port Dual-Head Displayport KVM switch with USB 2.0 and Audio Sharing

TNP Digital Torque Meter Operation Manual

VELOCICALC Air Velocity Meter

Enhanced Mini-Chansim Model VCS-232

Force Test Stands Series ES. User s Guide

Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

MODEL 245 / 345 High Range

User s Guide. POWERVAR Single Phase Power Conditioners

HDMI to 3GSDI Converter

AD Leak Tester INSTRUCTION MANUAL 1WMPD

IDS-801 Series Compact Bench Counting Scale. User Manual

iconverter 2-Module Power Chassis

USB 2.0 LR 4-Port Extender

USB 2.0 LR Extender. EXT-USB2.0-LR User Manual.

PRO 360. Owner's Manual

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

Power Rack 58. EXT-PS5-8R User Manual.

Adjustable Timing Control PN 8680

Model 8732 IAQ-CALC TM Indoor Air Quality Meter

I/O Expansion Box Installation & Operator s Instruction Manual

SA SERIES Arlingate Lane, Columbus, Ohio (614)

ELECTRONIC TORQUE METER ETM OPERATION INSTRUCTION

Dual-Link DVI over 2CAT6 Extender

FTC-200 X-ray Tube Controller Users Manual

Model TA4 Torque Analyzer

INSTRUCTION MANUAL. Models: H100 Light Meter

Series E ERGONOMICS FORCE GAUGES. User s Guide

PCM Operation Manual. Pulsed Current Source. Fort Collins, Colorado Phone Fax

UET Series Torque Analyzer Operations Manual

Operations Manual EcoSense ph100

EA014 TORQUE CALIBRATION ADAPTER OPERATION MANUAL

TB-100 ControLynx Terminal Block

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Transcription:

Series ST DIGITAL TORQUE TOOL TESTERS.com Mark-10 Corporation has been an innovator in the force and torque measurement fields since 1979. We strive to achieve 100% customer satisfaction through excellence in product design, manufacturing and customer support. In addition to our standard line of products we can provide modifications and custom designs for OEM applications. Our engineering team is eager to satisfy any special requirements. Please contact us for further information or suggestions for improvement. We make a measurable difference in force and torque measurement Mark-10 Corporation 11 Dixon Avenue Copiague, NY 11726 USA 1-888-MARK-TEN Tel: 631-842-9200 Fax: 631-842-9201 Internet: www.mark-10.com Email: info@mark-10.com 32-1065 1106 7

DIMENSIONS in [mm] WARRANTY Mark-10 Corporation expressly warrants to its buyer for three (3) years from the date of delivery that the goods sold are free from defects in workmanship and materials. Mark-10 Corporation will, at its option, repair or replace or refund the purchase price of goods found to be defective. This remedy shall be the buyer s sole and exclusive remedy. Any modification, abuse, exposure to corrosive environment or use other than intended will void this warranty. This warranty is in lieu of all other warranties, including implied warranties of merchantability and fitness for an intended purpose. In no event shall Mark-10 Corporation be liable for any incidental and consequential damages in connection with goods sold or any part thereof. 8

SPECIFICATIONS Accuracy: ±0.5% of full scale ±1digit Sampling rate: 65/s Display update rate: 2.5/s in normal mode, 65/s in peak mode Safe overload: 150% of gauge capacity. Display shows ---- (dashes) above 110%. Outputs: RS-232: Baud rates between 300 and 9600 Mitutoyo: Standard Mitutoyo BCD output Connector: 9-pin D-type male Power: 9V battery or AC adapter Battery life: 30 hours of continuous operation Weight: 10 lb [4.5 kg] Capacity x resolution: ST12 12 x 0.01 lbfin, 140 x 0.1 kgfmm, 135 x 0.1 Ncm ST50 50 x 0.05 lbfin, 580 x 0.5 kgfmm, 570 x 0.5 Ncm ST100 100 x 0.1 lbfin, 1150 x 1 kgfmm, 1150 x 1 Ncm Thank you! Thank you for purchasing a Mark-10 Series ST Digital Torque Tool Tester. We are confident that you will get many years of service from this product. The ST can be used to test a number of different torque tools, including screwdrivers, wrenches, and others. To maintain normal functioning of the tester, avoid repetitive overloads and shock loads. Note that impact and air tools cannot be used with the ST. We hope that this will provide a comprehensive explanation of the ST s operation and sufficient detail on its specifications. However, if you have any other questions or concerns, our technical support and engineering teams will be eager to help you. Thank you again for your purchase and happy testing! TABLE OF CONTENTS UNPACKING AND SETTING UP... 2 LIST OF INCLUDED ITEMS... 2 OPTIONAL ITEMS... 2 CONTROLS... 3 DISPLAY... 3 POWER... 4 OPERATION... 4 CONFIGURATION... 5 CALIBRATION... 6 OUTPUTS... 6 SPECIFICATIONS... 7 DIMENSIONS... 8 WARRANTY... 8 7 1

UNPACKING AND SETTING UP 1. Carefully unpack the torque tester and check for any damage. Inspect the contents to ensure that you have received a tester complete with all accessories see List of included items below. 2. Place the tester on a firm, flat and level working surface free from vibration. If preferred, the ST can be secured to a work bench with the optional bench mounting bracket (see below). There are four tapped holes in the underside of the base to facilitate bench mounting. LIST OF INCLUDED ITEMS Quantity 1 Series ST Torque Tester 1 User s guide (this booklet) OPTIONAL ITEMS Item 1 Bench mounting bracket (optional) 1 AC adapter 1 Certificate of calibration ST001 bench mounting bracket This bracket allows the ST to be mounted at any angle. It includes mounting hardware. OUTPUTS RS-232 and Mitutoyo BCD outputs are available on the 9-pin male connector. Refer to Fig. 2 below for a pin diagram. 1 2 6 7 3 4 5 8 DB-9P Fig. 2 Pin diagram of output connector 9 1 RS-232 receive Input 2 RS-232 transmit Output 3 Mitutoyo request Input 4 Mitutoyo clock Output 5 Signal ground - 6 No connection 7 No connection 8 Mitutoyo ready Output 9 Mitutoyo data Output RS-232 The data transmission can be initiated by pressing the DATA button (see Fig. 2) or by an external device by sending ASCII "?" to the gauge. The gauge will respond by sending the current reading in either full or numeric format, depending on the configuration setting (see Section 3). Polarity sign indicates CW (+) or CCW (-) torque. The transmitted string has the following format: [POLARITY (SPACE OR -)][DATA][SPACE][UNITS (IF ENABLED)][CRLF] Mitutoyo BCD This output is useful for connection to data collectors, printers, multiplexers or any other device capable of accepting Mitutoyo BCD data. The transmission is initiated by the DATA button (see Fig. 3) or by the receiving device. Fig. 3 Press the DATA button to output torque data 2 6

AoFF - Automatic shutoff settings sub-menu no Disabled 1 1-minute automatic shutoff 5 5-minute " 10 10-minute 20 20-minute " " 30 30-minute " " init - Initial (default) settings sub-menu LBIN Pound-inch as default unit KGMM Kilogram-millimeter " " NCM Newton-centimeter " " CCW Real time display at turn on PEAK CW Peak clockwise display at turn on PEAK CCW Peak counterclockwise display at turn on CAL - Calibration sub-menu. See CALIBRATION section. CALIBRATION To properly calibrate the ST, application of a precise torque value equal to the full capacity of the tester in lbin (regardless of the displayed units) will be required. While holding PEAK, turn on power to the tester. Press PEAK repeatedly until CAL appears on the display and press POWER three times to select the calibration mode. At the null prompt, press ZERO. At the SPAn prompt, apply the calibration torque and press POWER. The display will show uuuu or nnnn if the calibration torque is insufficient or excessive, respectively. If this happens, the only way to terminate the calibration mode is by momentarily disconnecting the battery or connecting the AC adapter to the tester without plugging the other end into a wall outlet. This will stop the calibration procedure without making any changes to the previous calibration data. Successful calibration is indicated by done on the display. Press POWER to save the changes and resume normal operation. CONTROLS Series ST Torque Testers have four keys for controlling all functions: POWER Turns power on and off. Also used to select configuration menu items. PEAK Used to select Clockwise Peak, Counterclockwise Peak or Normal (real time) display mode. The actual peak readings are always captured and can be recalled at any time. Also used to step through configuration menu items. ZERO DATA DISPLAY Zeros any tare value (up to the full capacity of the gauge) and clears the peak readings stored in memory. Used to manually output the torque data point currently displayed. The display consists of a 4 1/2-digit section and several indicators. Their functions are listed below. LO BAT Low battery voltage indicator CW Clockwise torque indicator CCW Counterclockwise torque indicator CW PEAK CCW PEAK LBIN, NCM, KGMM Peak clockwise indicator Peak counterclockwise indicator Units of measurement (model dependent) - - - - (dashes) Overload (>110% of range) 5 3

POWER The tester can be operated by the included 9V non-rechargeable battery or by the included AC adapter. Battery life is approximately 30 hours. Do not use adapters other than supplied or instrument damage may occur. There are three levels of low battery voltage indication. At the first level the display shows a steady "LO BAT" indicating approximately one hour of charge remaining. The second level is indicated by a flashing "LO BAT" indicator. At the third level the whole display except the "LO BAT" indicator will flash for three seconds after which time the instrument will turn itself off. This prevents the instrument from working at voltages too low for reliable operation. To access the battery, remove the cover on the underside of the base by loosening the four screws. OPERATION Place the tool into the receptacle, as shown in Fig. 1 below, and gradually exert torque by hand until the desired status is achieved (ex. click, slip, etc.). Sudden torque application may produce incorrect readings. After the peak reading is registered, it can be transmitted to a printer, PC, or data collector for further processing or storage. For details, see the Outputs section. Fig. 1 Gradually exert torque to achieve accurate results CONFIGURATION Series ST torque testers have several features with programmable options allowing many user-specified choices. To enter the configuration menu, perform the following: 1. Turn off the tester 2. Press and hold PEAK 3. Turn on the tester 4. Release PEAK The version number of the internal firmware will be displayed for a short time followed by '232'. The following secondary functions of keys are used during the configuration process: POWER Used to select a menu choice PEAK Used to step through menu choices The following list shows all configuration options. Italics indicate factory settings. 232 - RS-232 settings sub-menu 232d Output Disabled 232E Output Enabled 300 300 baud 600 600 baud 1200 1200 baud 2400 2400 baud 4800 4800 baud 9600 9600 baud 7-1E 7 data bits, 1 stop bit, even parity 7-1o 7 data bits, 1 stop bit, odd parity 7-2E 7 data bits, 2 stop bits, even parity 7-2o 7 data bits, 2 stop bits, odd parity 7-2n 7 data bits, 2 stop bits, no parity 8-1E 8 data bits, 1 stop bit, even parity 8-1o 8 data bits, 1 stop bit, odd parity 8-1n 8 data bits, 1 stop bit, no parity 8-2n 8 data bits, 2 stop bits, no parity Ft F Ft n Full data (numeric + units) Numeric data only bcd - Mitutoyo BCD settings sub-menu bcdd bcde npol POL Output disabled Output enabled No polarity (absolute value) Data with polarity (+ for CW, - for CCW) 4 5