Installation, Operation & Maintenance Instructions / Technical Document

Similar documents
Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

MAXIMA+ Series Rotary Level Indicator

FOR LIQUIDS AND SOLIDS

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

MAXIMA + Series ROTARY LEVEL CONTROL

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

User's Guide. Phase Sequence and Motor Rotation Tester Model

User Guide. Control Box. RoscoLED TM.

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-X4ME1 2M E2K-X4ME2 2M

V E1B Snap-in I/O Module

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

V E2B Snap-in I/O Module

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

User's Guide. Extech AM A AC Analog Clamp Meter

Thread length (overall length)

Thread length (overall length) material

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

MTP INSTRUCTION MANUAL

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

Solid State Relays with Failure Detection Function

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

S82S (3/7.5-W Models)

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Number of input channels

KOBOLD TDA Series Digital Temperature Transmitter

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Model NPN output PNP output Standard. configuration

User's Guide. Model High Precision Quad Output DC Power Supply

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

Global Water Instrumentation, Inc.

OZONE SWITCH Model OS-6. OS-6 Features

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

LS 5000 series Vibration Level Switch for liquids

Operating Instruction

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Inductive Proximity Sensor

PMDX-105 Quad Isolator Board

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

LCI User Manual mantracourt.com

Mini Digital Multimeter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Installation Guide MODELS 522 / 526. Pressure Transducers TOLL FREE FAX Web Site.

User s Guide. 600A AC Clamp Meter. Model 38387

V-9939B MICROPHONE ADAPTER

CMSA-100 Manual. Cinema Media Server Automation

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

V E2B Snap-in I/O Module

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Operating instructions. Switching amplifier DN0210 DN / / 2015

SLA Battery Capacity Analyzer

iconverter 2-Module Power Chassis

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

V E1B Snap-in I/O Module

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

NPN output. 200 mm. Type Cable length Model Remarks

Instruction Sheet Board Style Low Water Cutoff

D-Pack 6 Classic ORDERCODE 50315

KOBOLD PDA Series Digital Pressure Transmitter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

EZ-LIGHT SP Series Signal Light

Operating Instructions for Vibrating Level Switches. Model: NVI

PIM-Mini Pulsed Current Source Operation Manual

SP6R Level Controller Operation Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

TETRIS 2500 High Impedance Active Probe. Instruction Manual

I/O SIGNAL CONDITIONER

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

RAYMAPB. Power Supply and Terminal Box for Marathon MM/MR/FA/FR Sensors. Manual Addendum. Rev. A 06/

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

OPERATION MANUAL MODEL TT-LP

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Transcription:

Installation, Operation & Maintenance Instructions / Technical Document Model VHL Mini Vibrating Fork Point Level Sensor for Liquids Thank you for purchasing the Model VHL Mini Vibrating Fork Point Level Sensor for Liquids from BlueLevel Technologies. We sincerely appreciate your business and strive to make your experience with us and our products uniquely positive. This document contains information necessary to ensure a safe and successful installation. PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE PROCEEDING and comply with the section on page 3 of this document pertaining to SAFETY to ensure proper operation of the equipment and personnel safety. Before discarding the shipping container, please inspect it thoroughly and verify that all parts are accounted for. If you have any questions please do not hesitate to contact us on our website at www.blueleveltechnologies.com, by email bluelevel@blueleveltechnologies.com or by phone at 330-523-5215 or by fax at 330-523-5212. 1

Contents Safety Terms & Symbols 3 Mechanical Installation 5 Instrument Function 7 Electrical Connections 10 Setup 15 Maintenance 16 Technical Data 17 Dimensions 19 Our Commitment 21 Standard Warranty 22 2

Safety Terms & Symbols WARNING: Warning statements identify conditions or practices that could result in injury or loss of life. Risk of electrical shock exists. CAUTION: Caution statements identify conditions or practices that could result in damage to this product or other property. Safety Summary General Safety CAUTION: It is important that all instructions within this manual be followed to ensure proper operation of the equipment and safety of operating personnel. The product should be installed, commissioned and maintained by qualified and authorized personnel only. Install according to installation instructions and comply with all National and Local codes. Use electrical wire that is sized and rated for the maximum voltage and current of the application. Electrical Shock Caution Some Model VHL Mini Vibrating Fork Point Level Sensors for Liquids can be powered with HIGH VOLTAGE. No operator serviceable parts are inside. All servicing is to be performed by qualified personnel. Each Model VHL Mini 2-Wire AC sensor is provided with a protective conductor wire (green/yellow) which shall be terminated to earth ground potential (see Connections). Maintenance Power to all circuits must be disconnected before conducting any investigation, setup or maintenance of the unit. 3

Safety Summary Cont d. Electromagnetic Compatibility (EMC): The Model VHL Mini vibrating fork point level sensor for liquids was tested and found to comply with standards for electric shock and electromagnetic compatibility for CE marking. This product complies with the following regulations of the EC: Directive 93/68/EEC (CE Mark) Directive 2006/95/EC (LVD) Directive 2004/108/EC (EMC) Directive 2002/95/EC (RoHS) Directive 2002/96/EC (WEEE) The product has been tested according to the following standards: IEC 61010-1:2010 IEC 61326-1:2005 All test reports and documentation can be obtained from BlueLevel Technologies, Inc. located in Sterling, IL. 4

Mechanical Installation Prior to installation handle the Model VHL Mini in a careful manner to prevent any mechanical damage. Prevent Damage If side mounting the VHL Mini vibrating fork point level sensor then positioning of the fork tines is required so that the forks are vertical. Use Teflon sealing tape on the threaded process connection to seal the threads and position the fork tines appropriately using the mark Ο on the hex nut above the process connection. Low Viscosity Fluids In applications where the fork tines are easily freed from the process medium any mounting shown in Figure 1 is possible. High Viscosity Fluids In applications where the tines are not easily freed from the process medium, side or horizontal mounting is recommended. Figure 1: Mounting Arrangements 5

Mechanical Installation Cont d. For pipe mounting the fork tines must be parallel to the flow of the fluid. Pipe Mounting The switching point and the switch differential depends on the density of the liquid and the mounting orientation (side/horizontal or top/vertical). Switching Point and Differential for Water at +77⁰F (+25⁰C) (dimensions shown in mm, divide by 25.4 to convert to inches) 6

Instrument Function Introduction: The Model VHL Mini is a vibrating fork style point level sensor for liquids of high quality design and ergonomics, which provides reliable indication of the presence and absence of a wide range of liquids. The Model VHL Mini is an instrument that can be used for either High or Low level detection with output suitable for switching low current loads or as input to a PLC or other type of control system. Principle of Operation: The Model VHL Mini uses a mechanical resonance system. The mechanical element is excited and kept in resonance by the sensor s electronic circuitry. An electrical signal is applied to a piezoelectric crystal at the natural resonant frequency of the mechanical system. This electrical excitation causes physical deformation of the crystal, which inturn creates the probe element vibration. When no fluid is present around the probe, the vibration exists. With fluid present and surrounding the probe element, the vibration is dampened and detected by the electronic circuitry. This results in a change in the output and local LED indication. Application or Use: Model VHL Mini vibrating fork point level sensors are used to detect the presence and absence of a variety of fluids with a minimum density of 0.7 Specific Gravity or 0.7 g/cm 3 (0.7 kg/dm 3 ). Operating Conditions Temperature and Pressure play a factor in the performance and operation of the Model VHL Mini vibrating fork point level sensor for liquids. The charts shown in Figure 2 illustrate the relationship between the Pressure and medium (liquid) Temperature, as well as the relationship between the medium and ambient temperatures of the two primary versions of the Model VHL Mini level sensor. 7

Instrument Function Cont d. Pressure (P T) as a Function of Temperature (T M) for All Versions (⁰C shown) Temperature Limits DC versions (T A ambient and T M medium in ⁰C) and Load Current (I L) Temperature of AC Versions, Ambient (T A) and Medium (T M) Temperatures (shown in ⁰C) Figure 2: Pressure [P T] as a Function of Temperature [T M] and Temperature Limits 8

Instrument Function Cont d. Response Time It is important to understand the time it takes for the Model VHL Mini sensors to respond when immersed and when getting free from the process fluid. The time to respond when immersed is generally fixed to 0.5 seconds. However, the response time when getting free is a function of the viscosity of the fluid. Refer to the diagram in Figure 3. Figure 3: Response Time Diagram (when getting free); Response Time Vs. Viscosity Output Mode LED Indication The Model VHL Mini vibrating fork point level sensor incorporates a bi-color LED for local indication of output state. After proper mechanical and electrical installation, and checking to ensure the Model VHL Mini level sensor is operational, you can confirm proper operation using the BlueLevel Technologies test magnet (magnet end of BlueLevel screwdriver included) and the sensor LED (bi-color; red and green). For further information refer to Setup section. 9

Electrical Connections Electrical Precautions: Refer to Safety Summary section on pages 3 and 4 of this manual before beginning electrical connections. Observe all government regulations regarding equipment in hazardous locations. For all models, ensure that the power source is disconnected before installing or servicing the unit. Permanently Connected Equipment: Disconnecting devices shall be included in the system installation. In installations where multiple circuits are used, individual disconnects are required. Disconnects shall be within close proximity of the equipment, accessible to operators, and marked appropriately as being the disconnect for the associated circuit. Assure all disconnect ratings are appropriately sized for the circuit protected (Refer to Technical Data section). Protective Earth Ground: Each AC powered Model VHL Mini unit is provided with a protective conductor wire which shall be terminated to the local earth ground potential to eliminate shock hazard. Select a wire size that can carry in excess of the sum of the maximum amperage of all circuits. 10

Electrical Connections Cont d. 2-Wire AC Versions: DO NOT POWER UP THE DEVICE WITHOUT A LOAD CONNECTED IN SERIES WITH THE UNIT AND WITHOUT PROPER GROUNDING! The 2-wire AC version is provided with a 4 wire cable. Only one of either the BLACK or BROWN wires will be used (not both) as this is dependent upon whether the application is to use the Model VHL Mini as a HIGH-level limit switch or as a LOW-level limit switch. Refer to wiring diagram shown in Figure 4. Refer to Setup section for additional information regarding output state and wiring Mode (High or Low) HIGH LEVEL Mode Limit Switch LOW LEVEL Mode Limit Switch Figure 4: 2-Wire AC Versions Wiring Diagram (High and Low Level) 11

Electrical Connections Cont d. 3-Wire DC Versions: The 3-wire DC versions are typically used for either the input to a PLC or for engaging the coil of an external relay. Wiring diagrams are shown for both applications, Relay (Figure 5) and PLC (Figure 6) and for wiring as NPN or PNP output types. NPN Wiring as HIGH LEVEL Mode Limit Switch NPN Wiring as LOW LEVEL Mode Limit Switch Figure 5a: Wiring for DC (NPN) Versions in Applications with Relay 12

Electrical Connections Cont d. PNP Wiring as HIGH LEVEL Mode Limit Switch PNP Wiring as LOW LEVEL Mode Limit Switch Figure 5b: Wiring for DC (PNP) Versions in Applications with Relay 13

Electrical Connections Cont d. PNP Wiring as HIGH LEVEL Mode Limit Switch PNP Wiring as LOW LEVEL Mode Limit Switch Figure 6: Wiring for DC Versions in Applications with PLC 14

Setup Before placing the Model VHL Mini level sensor in operation check and verify the connection of wiring and mechanical installation and understand the intended use (High or Low Level Limit Switch) and output action that you require. The operation of the Model VHL Mini vibrating fork point level sensor is summarized as follows in the below table (U TAP = Power Supply Voltage): Operational Test Correct operation of an installed Model VHL Mini vibrating fork point level sensor for liquids switching circuit can be tested and verified with the test magnet supplied (at end of BlueLevel Technologies screwdriver included in instruction package). Moving the test magnet in front of the mark on the cover of the housing the device will perform a switching action (LED will change color) 15

Maintenance In some instances the sensor probe may require occasional cleaning to remove surface deposits. This should be carried out gently without damaging the vibrating section of the Model VHL Mini vibrating fork point level sensor. Do not hit the Model VHL sensor to remove any material build-up. Do not use any banging to effect the cleaning if ever necessary. 16

Technical Data GENERAL Medium Pressure: 588psi (40bar) (see diagram on page 8) Probe Lengths: Short 2.72 (69mm) Standard 4.92 (125mm) Long 7.87 (200mm) Extended Lengths >7.87 (200mm) up to 118 (3m) Wetted Parts Materials: 316Ti (DIN 1.4571) Stainless Steel Medium Temperature: See diagrams on page 8 Ambient Temperature: See diagrams on page 8 Liquid Density: 0.7 S.G. (0.7g.cm 3 ) Liquid Viscosity: 10,000 cst (mm 2 /s) Response Time: When Immersed 0.5sec When Free 1.0sec (see Figure 3 on page 9) Output Mode Indication: Bi-Color LED (Red/Green) Operation Test: Output can be changed by test magnet Materials: 17

Technical Data Cont d. 2-WIRE AC VERSIONS Electrical Connections: Housing Protection: High/Low Mode Setting: Output: Supply Voltage: Power Consumption: Voltage Drop (switched-on): (switched-on state) Electrical Protection: Current Load: Maximum Continuous Minimum Continuous Maximum Impulse Residual Current (switched off): 3-WIRE DC VERSIONS Electrical Connections: Housing Protection: High/Low Mode Setting: Output: Output Protection: Supply Voltage: Power Consumption: Voltage Drop (switched-on): (switched-on state) Electrical Protection: Current Load: Maximum Continuous Residual Current (switched off): Integral prewired cable (4 conductors); 3m Length IP68 Wiring selectable 2-wire AC for serial connection with load 20-255VAC, 50/60Hz Load Dependent <10.5V Class I (appliance class) 350mA AC-13 (IEC Utilization Category) 10mA @ 255V, 25mA @ 24V 1.5A for 40msec <6mA Integral prewired cable (4 conductors); 3m Length IP68 Wiring selectable Field selectable PNP/NPN transistor switch Reverse polarity, overcurrent and short-circuit protected 12-55VDC <0.6W <4.5V Class III (appliance class) I max = 350mADC / U max = 55VDC See diagram on page 8 <100μA 18

Dimensions Short Probe Version Dimensions shown in mm, convert to inches by dividing by 25.4. Connector top shown not yet available. Prewired top shown in top right corner. BSP Threaded connection not yet available. Consult factory. 19

Dimensions Cont d. Standard, Long and Extended Probes Dimensions shown in mm, convert to inches by dividing by 25.4. BSP threaded connection not yet available. Consult factory. 20

Our Commitment Stands Golden Parachute: Each BlueLevel Technologies Model VHL Mini vibrating fork point level sensor for liquids is backed by our Golden Parachute support program. If you are the initial purchaser and purchased the product directly from BlueLevel Technologies, this provides you with added assurance. The Golden Parachute support program gives the initial purchaser 90 days to evaluate the product. Within this time frame if you are not satisfied for any reason, call us and request a Golden RMA, providing your order details and serial number on the unit, and then return the unit and request a replacement or a credit to your account for the cost of the equipment as shown on your invoice from BlueLevel Technologies. In addition, Model VHL Mini products are covered by our industry-leading 2- year limited warranty. Consult our Warranty statement for details. 21

Standard Warranty Each BlueLevel Technologies Model VHL Mini vibrating fork point level sensor product is backed by our industry-leading 2-year limited warranty. Should you experience a problem with one of our products deemed by our factory to be a product failure covered by our warranty, for a period of 2-years from the date of shipment we will repair the unit at our factory or provide you with a replacement unit or sub-assembly at our discretion. A return authorization number must be obtained from a BlueLevel Technologies customer service technician BEFORE returning any unit. Refer to the below details for more information. Details: We warrant BlueLevel Technologies products to be free from defects in workmanship and materials when operated under normal conditions and in accordance with nameplate characteristic limits. Products must be installed and maintained in accordance with BlueLevel Technologies installation, operation and maintenance instructions. Users are responsible for the suitability of the products to their application. There is no warranty against damage resulting from misapplication, improper specifications, or other operating conditions beyond our control. Claims against carriers for damage in transit must be filed by the buyer. This warranty shall be in effect for a period of twenty-four months from the date of shipment. THIS WARRANTY SHALL BE IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BlueLevel Technologies will repair or replace, at its option, any product which has been found to be defective and is within the warranty period, provided that the product is shipped, with previous factory authorization, freight prepaid, to the factory in Rock Falls, Illinois, U.S.A., or to the nearest service station. BlueLevel Technologies is not responsible for removal, installation, or any other incidental expenses incurred in shipping the products to or from BlueLevel Technologies. BlueLevel Technologies liability under this warranty shall be solely limited to repair or replacement of the products within the warranty period, and BlueLevel Technologies shall not be liable, under any circumstances, for consequential or incidental damages, including, but not limited to, personal injury or labor costs. Under no circumstances will BlueLevel Technologies be responsible for any expense in connection with any repairs made by anyone other than the factory or an authorized service station, unless such repairs have been specifically authorized in writing. 22

23

3778 Timberlake Drive, Richfield, OH 44286 Ph: 330-523-5215 Fx: 330-523-5215 www.blueleveltechnologies.com bluelevel@blueleveltechnologies.com Copyright 2012 BlueLevel Technologies, Inc. Form 1502 Printed in USA 12/12 24