Lightning and surge protection for single-family houses

Similar documents
Surge protection for LED mast lights

Surge protection for gutter heating systems

Surge protection for telecommunication connections

Surge protection for frequency converters

Lightning and surge protection for electromobility

White Paper Surge protection for gutter heating systems

Application-optimised DEHNshield Combined Arrester

White Paper. Lightning and surge protection for free field PV power plants. Contents

Lightning and surge protection for yachts

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

Overvoltage Protection Devices

POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment

White Paper Lightning and surge protection for rooftop photovoltaic systems

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

DEHN protects Photovoltaic Systems.

DEHN tests and analyses DEHN Test Centre.

Overvoltage Protection Devices

wietap wietap Overvoltage Protection Tensions running high

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Lightning and surge protection for intelligent transformer substations

Overvoltage Protection Devices

R3&A Limited, Cobourg, ON

Overvoltage Protection Devices

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

Overvoltage Protection Devices

APPLICATION PROPOSAL. Lightning and Surge Protection SV55/E/0112

DEHN protects Smart Power Grids.

BLITZDUCTOR XTU Universal lightning current / surge arrester

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

DEHNsecure protects Direct Current Applications.

DEHN protects Photovoltaic Systems.

PT 3-PB-ST. Extract from the online catalog. Order No.:

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

DEHN protects Biogas Plants.

Surge Protection Devices and Surge Protection Kit

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Coordinated Surge Protection

White Paper. Lightning and surge protection for wind turbines. Contents

INFORMATION TECHNOLOGY SYSTEMS

Surge Protection Devices Ex9UE2

Lightning and Surge Arresters

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

SPD Catalogue. SPD Catalogue. for AC applications

Retrofitting sewage plants with lightning and surge protection measures

LIGHTNING PROTECTION FOR ROOFTOP PV PLANTS LIGHTNING & SURGE PROTECTION SYSTEM

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Company Profile Surge Protective Devices

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Catalogue valid as of January 1,

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester

DEHN protects Photovoltaic Systems

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Lightning & Surge Protection for Wind Turbine Systems

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Lightning Current Equipotential Bonding SPDs

NEW surge protective devices

Surge protection for transceiver systems

Surge Protective Device

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Surge Protection for Low Voltage Power Systems

Surge protection selection aid

Surge Protection Main Catalogue 2014/ New Products.

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

ETITEC - Lightning and Surge Arresters

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

Lightning and surge protection for wind turbines

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

BETA Protecting Overvoltage Protection Devices

Lightning and Surge Arresters

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

160 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

VAL-CP-3S-350. Extract from the online catalog. Order No.:

Making the Right Choices In Lightning & Surge Arrestors Some Basics:

Deploying surge protective devices (SPDs) in photovoltaic systems. Technical Information

Surge protection selection aid

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

6/2 Product overview. 6/3 Lightning arresters, type 1. 6/5 Combination surge arresters, type 1 and type 2. 6/7 Surge arresters, type 2

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

OPTIMISED LUMINAIRE PROTECTION

L*W*H:120*65*35.5 L*W*H:152*133*48 L*W*H:220*143*48 L*W*H:360*280*132 for 1ph 5A~10A for 1ph 10A~16A for 1ph 20A~45A for 1ph 50A~120A/200kA

Surge Protection for Surveillance Systems

Surge Protection Devices Type 1+2

BS th Edition wiring regulations Furse overview

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

OPTIMISED LUMINAIRE PROTECTION

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

High Performance Network Isolator

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

Overvoltage Protection for low-voltage supplies

Lightning and Surge Protection for PV Systems

NTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/

RTU500 series Data Sheet Power Supply CP-E 24/2.5

A.3 Lightning and surge voltage protection

Transcription:

Lightning and surge protection for single-family houses White Paper Contents Benefits of protecting an antenna by means of an isolated LPS instead of earthing the antenna Protection of the heat pump / compressor by means of shielding / earthing Combined arresters protect in case of nearby lightning strikes and form the basis for the external lightning protection system www.dehn-international.com

Lightning and surge protection for single-family houses White Paper PV modules MS ~ M M SEB SDB TC NT BC MEB BW HP H/C HP connection to the building s EB Figure 1 Surge protection for a single-family house with isolated lightning protection system of an antenna Single-family houses increasingly use renewable sources of energy (sun / wind) for hot water collectors, photovoltaic modules and small wind turbines. While small wind turbines are currently not often installed, solar energy with an insolation of 1100 to 1300 kwh/m 2 /year already ensures a high yield all over Germany. An increasing share of electricity meanwhile comes from small distributed solar power stations. While solar hot water collectors directly heat the boiler water (BW) via heat exchangers, a photovoltaic system generates electrical energy which can be used in many different ways. For example, this energy can be used to cover the daily energy demand of an air source heat pump (HP) which is supplied by the energy storage system (batteries) of the photovoltaic system or the grid of the distribution network operator during night time. In this case, a separate measuring device for the air source heat pump is not required. It is advisable to install a combined arrester downstream of the measuring device (M) (Figures 1 and 2). Be it the energy management of a bivalent (heating / cooling (H/P)) air source heat pump or the KNX scene control of the lighting / shutter system while on holiday, a gateway, which is controlled by the telephone or broadband cable (BC), is always required. The worldwide web which is taken for granted today can only be used if the DSL modem or the DSL router is not destroyed by surges which spread through the telephone or broadband cable. Also in these cases, a combined arrester can avoid destruction (Figures 1 and 2). However, not only conducted impulse currents, but also lightning strikes can cause surges. If no external lightning protection system is installed on a single-family house and lightning hits the antenna mast, the same physical conditions occur as in case of a single-family house with external lightning protection system. The potential of the earth electrode rises and surges are injected into the single-family house. This cannot be prevented by earthing the antenna mast according to the standard and establishing equipotential bonding for the coaxial shields. Therefore, it is advisable to use DEHNcon-H to protect the satellite system of a single-family house without external lightning protection system from direct lightning strikes (Figure 1). If the risk for a single-family house without external lightning protection system has been significantly reduced by an appli- 2

Lightning and surge protection for single-family houses White Paper PV modules MS ~ SEB M M SDB TC NT BC MEB BW H/C HP HP connection to the building s EB Figure 2 Surge protection for a single-family house with external lightning protection system cation-optimised combined arrester, adequate air-termination systems and down conductors leading to the earth-termination system are required to ensure efficient external lightning protection. The DEHNcon-H conductor, which is routed up to the earth electrode, is then connected to the metallic gutter (Figure 2). No. in Fig. 1 and 2 Protection for Surge protective device Part No. * Observe optional accessories Table 1 Power supply system (TN-S system) Power supply system (TT system) Surge protective devices for a single-family house DEHNshield DSH TNS 255 DEHNshield DSH TT 255 941 400 941 310 Telephone DEHNbox DBX TC 180 922 210 Broadband cable DEHNgate DGA GFF TV 909 705 Coaxial cable of the multiswitch (MS) DEHNgate DGA FF TV 909 703 Power supply of the multiswitch (MS) DEHNcord DCOR L 2P 275 900 430 d.c. input of the inverter DEHNcube DCU YPV SCI 1000 1 M 900 910 * Power supply and LAN PC DEHNprotector DPRO 230 LAN 100 909 321 Power supply and coaxial TV cable DEHNprotector DPRO 230 TV 909 300 3

Lightning and surge protection for single-family houses White Paper If additional surge protective devices (Figures 1 and 2) are installed, it is assumed that the a.c. connection of the inverter and the heat pumps are located in the protected volume (about 5 m) of the supply-side combined arrester and that the cables leading to the compressor are shielded. The compressor housing / foundation must be connected to the earthtermination system by means of a lightning current carrying 16 mm 2 copper conductor. 4

White Paper: Surge protection for frequency converters DEHNshield DSH TT 255 (941 310) Application-optimised and prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TT 255 Dimension drawing DSH TT 255 Application-optimised and prewired combined lightning current and surge arrester for TT and TN-S systems ("3+1" circuit). DSH TT 255 Part No. 941 310 SPD according to EN 61643-11 / IEC 61643-11 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Nominal a.c. voltage (U N ) Max. continuous operating a.c. voltage (U C ) 230 / 400 V (50 / 60 Hz) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (I total ) 50 ka Specific energy [L1+L2+L3+N-PE] (W/R) 625.00 kj/ohms Lightning impulse current (10/350 µs) [L-N]/[N-PE] (I imp ) 12.5 / 50 ka Specific energy [L-N]/[N-PE] (W/R) 39.06 / 625.00 kj/ohms Nominal discharge current (8/20 µs) [L-N]/[N-PE] (I n ) 12.5 / 50 ka Voltage protection level [L-N]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability [L-N]/[N-PE] (I fi ) Follow current limitation / Selectivity 25 ka rms / 100 A rms no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg Temporary overvoltage (TOV) [L-N] (U T ) Characteristic Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 440 V / 120 min. withstand 1200 V / 200 ms withstand Operating temperature range (T U ) -40 C... +80 C Operating state / fault indication green / red Number of ports 1 Cross-sectional area (L1, L2, L3, N, PE, 9) (min.) Cross-sectional area (L1, L2, L3, N, PE, 9) (max.) 1.5 mm 2 solid / flexible 35 mm 2 stranded / 25 mm 2 flexible For mounting on 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 4 module(s), DIN 43880 Approvals KEMA, VDE, UL 480 g Customs tariff number 85363030 GTIN 4013364131798 1 pc(s) 5

White Paper: Surge protection for frequency converters DEHNshield DSH TNS 255 (941 400) Application-optimised and prewired type 1 and type 2 spark-gap-based combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TNS 255 Dimension drawing DSH TNS 255 Application-optimised and prewired combined lightning current and surge arrester for TN-S systems. DSH TNS 255 Part No. 941 400 SPD according to EN 61643-11 / IEC 61643-11 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Nominal a.c. voltage (U N ) Max. continuous operating a.c. voltage (U C ) 230 / 400 V (50 / 60 Hz) 255 (50 / 60 Hz) Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (I total ) 50 ka Specific energy [L1+L2+L3+N-PE] (W/R) 625.00 kj/ohms Lightning impulse current (10/350 µs) [L, N-PE] (I imp ) 12.5 ka Specific energy [L,N-PE] (W/R) 39.06 kj/ohms Nominal discharge current (8/20 µs) [L/N-PE]/[L1+L2+L3+N-PE] (I n ) 12.5 / 50 ka Voltage protection level [L-PE]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability a.c. (I fi ) 25 ka rms Follow current limitation / Selectivity no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg Temporary overvoltage (TOV) [L-N] (U T ) Characteristic 440 V / 120 min. withstand Operating temperature range (T U ) -40 C... +80 C Operating state / fault indication green / red Number of ports 1 Cross-sectional area (L1, L2, L3, N, PE, 9) (min.) Cross-sectional area (L1, L2, L3, N, PE, 9) (max.) 1.5 mm 2 solid / flexible 35 mm 2 stranded / 25 mm 2 flexible For mounting on 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 4 module(s), DIN 43880 Approvals KEMA, VDE, UL 525 g Customs tariff number 85363030 GTIN 4013364133563 1 pc(s) 6

White Paper: Surge protection for frequency converters DEHNcord DCOR L 2P 275 (900 430) Visual fault indication Compact design For use in flush-mounted systems, cable ducts and flush-type boxes Surge arrester for all installation systems; compact design. Basic circuit diagram DCOR L 2P 275 Dimension drawing DCOR L 2P 275 DCOR L 2P 275 Part No. 900 430 SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II Nominal a.c. voltage (U N ) 230 V (50 / 60 Hz) Max. continuous operating a.c. voltage [L-N] (U C ) 275 V (50 / 60 Hz) Max. continuous operating a.c. voltage [N-PE] (U C ) 255 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 5 ka Max. discharge current (8/20 µs) (I max ) 10 ka Total discharge current (8/20 µs) [L+N-PE] (I total ) 20 ka Voltage protection level [L-N] (U P ) 1.5 kv Voltage protection level [L-N] at 3 ka (U P ) 1 kv Voltage protection level [L-N] at 1.5 ka (U P ) 0.85 kv Voltage protection level [N-PE] (U P ) 1.5 kv Follow current extinguishing capability [N-PE] (I fi ) 100 A rms Response time [L-N] (t A ) 25 ns Response time [L/N-PE] (t A ) 100 ns Max. mains-side overcurrent protection 16 A gl/gg Short-circuit withstand capability for mains-side overcurrent protection (I SCCR ) 25 ka rms Temporary overvoltage (TOV) [L-N] (U T ) Characteristic 335 V / 5 sec. withstand Temporary overvoltage (TOV) [L-N] (U T ) Characteristic 440 V / 120 min. safe failure Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 1200 V / 200 ms withstand Operating state / fault indication green / red Number of ports 1 Operating temperature range (T U ) -40 C... +80 C Connecting wires 1.5 mm 2, length: 200 mm Enclosure material thermoplastic, red, UL 94 V-2 Place of installation indoor installation Degree of protection of installed device IP 20 59 g Customs tariff number 85363010 GTIN 4013364157286 1 pc(s) 7

White Paper: Surge protection for frequency converters DEHNcube DCU YPV SCI 1000 1M (900 910) Prewired multipole surge arrester with IP 65 degree of protection for photovoltaic systems Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage caused by d.c. switching arcs (patented SCI principle) Easy and fast implementation of surge protection measures since no space is required in a separate insulating enclosure Basic circuit diagram DCU YPV SCI 1000 1M Multipole surge arrester with three-step d.c. switching device for PV inverters with one MPP input. Dimension drawing DCU YPV SCI 1000 1M DCU YPV SCI 1000 1M Part No. 900 910 SPD according to EN 50539-11 type 2 Max. PV voltage (U CPV ) 1000 V Short-circuit withstand capability (I SCPV ) 1000 A Total discharge current (8/20 µs) (I total ) 40 ka Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE ] (I n ) 12.5 ka Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (I max ) 25 ka Voltage protection level (U P ) 4 kv Voltage protection level at 5 ka (U P ) 3.5 kv Response time (t A ) 25 ns Operating temperature range (T U ) -35 C... +80 C Operating state / fault indication green / red Number of ports 1 Cross-sectional area (min.) 2.5 mm 2 solid / flexible Cross-sectional area (max.) 6 mm 2 solid / flexible Place of installation outdoor Degree of protection IP 65 with pressure compensating element Cover transparent cover with product label of enclosure grey Number of cable entries 3x Ø3-7 mm Enclosure dimensions (w x h x d) 94 x 94 x 81 mm Approvals KEMA 426 g Customs tariff number 85363030 GTIN 4013364155046 1 pc(s) 8

White Paper: Surge protection for frequency converters DEHNbox + DBX TC 180 (922 210) Powerful protection for telecommunication interfaces Suitable for wall mounting, IP 65 Installation in conformity with the lightning protection zone concept at the boundaries from 0 A 2 and higher Basic circuit diagram DBX TC 180 Dimension drawing DBX TC 180 Compact combined arrester in a surface-mounted plastic enclosure for protecting information technology interfaces, particularly telecommunication connections and devices such as analogue telephone, ISDN and xdsl (VDSL2-tested). Fast connection of one pair without tools and integrated strain relief for the connecting cable. Cut-off frequency up to 250 MHz ensures maximum transmission performance in case of high-frequency signal parts. DBX TC 180 Part No. 922 210 L Nominal voltage (U N ) Max. continuous operating d.c. voltage (U C ) Max. continuous operating a.c. voltage (U C ) Nominal current at 45 C (I L ) D1 Total lightning impulse current (10/350 µs) ( I imp ) D1 Lightning impulse current (10/350 µs) per line ( I imp ) C2 Total nominal discharge current (8/20 µs) ( I n ) C2 Nominal discharge current (8/20 µs) per line ( I n ) Voltage protection level line-line at 1 kv/µs C3 (U p ) Voltage protection level line-pg at 1 kv/µs C3 (U p ) Voltage protection level line-line for I imp D1 (U p ) Voltage protection level line-pg for I imp D1 (U P ) Series resistance per line Bandwidth line-line (100 ohms) (f G ) Capacitance line-line (C) Capacitance line-pg (C) 180 V 180 V 127 V 0.75 A 7.5 ka 2.5 ka 15 ka 7.5 ka 250 V 550 V 300 V 550 V 1.8 ohms 250 MHz 20 pf 10 pf Operating temperature range (T U ) -25 C... +40 C Degree of protection IP 65 Cross-sectional area of the signal lines, solid 0.2-1.5 mm 2 Cross-sectional area of the signal lines, flexible 0.25-1.5 mm 2 Cross-sectional area of the earth terminal 0.25-2.5 mm 2 Dimensions (L x W x H) Enclosure material 93 x 93 x 55 mm polycarbonate Test standards IEC 61643-21 / EN 61643-21 Customs tariff number 85363010 GTIN 4013364158214 grey 138 g 1 pc(s) 9

DPRO 230 TV (909 300) White Paper: Surge protection for frequency converters Surge protective device for TV, radio or SAT applications with a m F socket to IEC plug adapter included For installation in conformity with the lightning protection zone con DPRO 230 TV (909 300) DEHNprotector DPRO 230 TV (909 300) Surge protective device for TV, radio or SAT applications with a modern design F socket to IEC plug adapter included For installation in conformity with the lightning protection zone concept at the boundaries Basic circuit dia Surge protective device for the power and antenna side of TV, radio or S child lock. C2 Nominal discharge current (8/20 µs) Basic line-shield circuit diagram (PE) (IDPRO Surge protective device for the power and antenna side of TV, radio or SAT receivers. With visual operating state and fault indication and integrated n) 230 TV child lock. Surge protective device for the Voltage power protection and antenna level line-shield side of (PE) TV, at radio 1 kv/µs or SAT C3 (U p) receivers. With visu child lock. Insertion loss 0-2400 MHz Protection of the data side Operating temperature range (T Protection of the data side U) Degree of protection DPRO 230 TV Part No. Part No. 909 300 Earthing via B Enclosure material Max. continuous operating d.c. voltage (U C ) Max. continuous operating d.c. voltage (U C) 60 V C2 Nominal discharge current (8/20 µs) line-shield (PE) (I n ) C2 Nominal discharge current (8/20 µs) line-shield (PE) (I 5 ka n) Test standards Voltage protection level line-shield (PE) at 1 kv/µs C3 (U p ) Voltage protection level line-shield (PE) at 1 kv/µs C3 (U p) 600 V Insertion loss 0-2400 MHz Protection of the power side Insertion loss 0-2400 MHz 1.5 db Operating temperature range (T U) Operating temperature range (T U ) -25 C... +40 C Degree of protection Part No. Degree of protection SPD according IP 20 to EN 61643-11 / IEC 61643-11 Nominal a.c. voltage (U F socket / F socket N) Earthing via protec Max. continuous operating a.c. voltage (U C) Earthing via Enclosure material protective conductor connection th Nominal load current a.c. (I L) Enclosure material thermoplastic, Nominal discharge UL current 94 V-2 (8/20 µs) (I n) Test standards Total discharge pure white current (8/20 µs) [L+N-PE] (I total) IEC Test standards wave / EN 61643-21 (U oc) IEC Combination 61643-21 Protection of the power side Protection of the power side SPD according to EN 61643-11 / IEC Voltage 61643-11 DPRO protection 230 level TV [L/N-PE] (U p) Combination wave [L+N-PE] (U oc total) Part No. Voltage protection level [L-N] (U p) Part No. Nominal a.c. voltage (U N) Response 909 time 300 [L-N] (t A) SPD according to EN 61643-11 / IEC 61643-11 Response type 3 time / class [L/N-PE] III (t Max. continuous operating a.c. voltage (U C) A) Nominal a.c. voltage (U N ) Nominal load current a.c. (I L) Max. mains-side overcurrent protection 230 V (50 / 60 Hz) Max. continuous operating a.c. voltage (U C ) Short-circuit withstand capability for mains-side overcurrent Nominal discharge current (8/20 µs) protection (I 255 n) V (I (50 SCCR) / 60 Hz) Nominal load current a.c. (I L ) Total discharge current (8/20 µs) [L+N-PE] Temporary (I 16 overvoltage total) A (TOV) [L-N] (U T) Characteristic Nominal discharge current (8/20 µs) (I n ) Combination wave (U oc) Temporary overvoltage (TOV) [L-N] (U 3 ka T) Characteristic Total discharge current (8/20 µs) [L+N-PE] (I total ) Combination wave [L+N-PE] (U oc total) Temporary overvoltage (TOV) [L/N-PE] (U T) Characteristic 5 ka Voltage protection level [L-N] (U p) Temporary overvoltage (TOV) [L/N-PE] (U T) Characteristic Combination wave (U oc ) 6 kv Voltage protection level [L/N-PE] (U Temporary p) overvoltage (TOV) [L+N-PE] (U T) Characteristic Combination wave [L+N-PE] (U oc total ) Response time [L-N] (t A) Fault indication 10 kv Voltage protection level [L-N] (U p ) Response time [L/N-PE] (t A) Operating state 1.25 indication kv Voltage protection level [L/N-PE] (U p ) Number of ports Max. mains-side overcurrent protection 1.5 kv 1 For mounting on Response time [L-N] (t A ) Short-circuit withstand capability for mains-side 25 ns overcurrent protection (I Test standards SCCR) Response time [L/N-PE] (t A ) 100 ns Temporary overvoltage (TOV) [L-N] (U T) Characteristic 33 Max. mains-side overcurrent protection Customs 16 A gl/gg tariff number or B 16 A Temporary overvoltage (TOV) [L-N] (U T) Characteristic 440 Short-circuit withstand capability for mains-side overcurrent GTIN Temporary overvoltage (TOV) [L/N-PE] (U protection (I SCCR ) T) Characteristic 335 1 ka rms Temporary overvoltage (TOV) [L/N-PE] (U T) Characteristic 44 Temporary overvoltage (TOV) [L-N] (U T ) Characteristic Temporary overvoltage (TOV) [L+N-PE] 335 V / (U 5 sec. withstand T) Characteristic 1200 V Temporary overvoltage (TOV) [L-N] (U T ) Characteristic Fault indication 440 V / 120 min. safe failure Temporary overvoltage (TOV) [L/N-PE] (U T ) Characteristic Operating state indication 335 V / 120 min. withstand Temporary overvoltage (TOV) [L/N-PE] (U T ) Characteristic Number of ports 440 V / 5 sec. withstand Temporary overvoltage (TOV) [L+N-PE] (U T ) Characteristic For mounting on 1200 V + U REF / 200 ms safe failure earthed socket out Test standards Fault indication red indicator light Operating state indication green indicator light Customs tariff number Number of ports GTIN 1 For mounting on earthed socket outlets according to DIN 49440/DIN 49441 Test standards EN 61643-11 Customs tariff number 85363010 GTIN 4013364117723 Protection of the data side Part No. Surge protective device for TV, radio or SAT applications with a modern design F socket to IEC plug adapter included For installation in conformity with the lightning protection zone concept at the boundaries from 2 3 a Max. continuous operating d.c. voltage (U C) 234 g 1 pc(s) 10

DPRO 230 LAN100 (909 321) White Paper: Surge protection for frequency converters Surge protective device for Ethernet components (1000 BASE- Shielded Cat 5e patch cable (1.5 m) included For installation in conformity with the lightning protection zone c DEHNprotector DPRO 230 LAN100 (909 321) Basic circuit dia Combined surge protection for the power side and data input for prote It meets the requirements for channel class D in accordance with EN 5 With visual operating state and fault indication and integrated child loc Surge protective device for Ethernet components (1000 BASE-T) with an elegant design Shielded Cat 5e patch cable (1.5 m) included Protection of the data side For installation in conformity with the lightning protection zone concept at the boundaries from 2 3 Part and No. highe Basic circuit diagram DPRO 230 LAN100 Combined surge protection for the power side and data input for protecting LAN components. Combined Protection surge protection of Max. for all continuous the pairs power for operating side Ethernet and data d.c. voltage input pin for assignment. (Uprotecting C) LAN components. Protec It meets the requirements for channel class D in accordance with EN 50173 and is thus It suitable meets the requirements for 1000 Lightning Base-T for channel impulse (Gigabit class current D in Ethernet). accordance (10/350 µs) with per line EN D1 50173 (I imp) and is thus suitable for 1 With visual operating state and fault indication and integrated child lock. With visual operating state C2 and Nominal fault indication discharge and current integrated (8/20 µs) child line-line lock. (I n) Protection of the data C2 side Nominal discharge current (8/20 µs) line-pe (I n) Protection of the data side C2 Total nominal discharge current (8/20 µs) (I n) DPRO Part No. DPRO 230 Voltage LAN100 protection level line-line for I n C2 (U p) Part No. 909 Voltage 321 protection level line-pe for I n C2 (U p) Max. continuous operating d.c. voltage (U Q C) Voltage protection level line-line at 1 kv/µs C3 (U p) Max. continuous operating d.c. voltage (U C) Lightning impulse current (10/350 µs) per line D1 (I imp) 58 Voltage V protection level line-pe at 1 kv/µs C3 (U p) C2 Nominal discharge current (8/20 µs) line-line (I n) Lightning impulse current (10/350 µs) per line D1 (I imp) 1 ka Cut-off frequency (f G) C2 Nominal discharge current (8/20 µs) line-pe (I n) C2 Nominal discharge current (8/20 µs) line-line (I n) Operating temperature range (T C2 Total nominal discharge 30 current A (8/20 µs) (I U) n) Degree of protection C2 Nominal discharge current (8/20 µs) line-pe (I n) Voltage protection level 2.5 line-line ka for I n C2 (U p) Voltage protection level line-pe for I C2 Total nominal discharge current (8/20 µs) (I n C2 (U p) n) 10 Pinning ka Voltage protection level line-line at 1 kv/µs C3 (U p) Voltage protection level line-line for I n C2 (U p) 100 Earthing V via Voltage protection level line-pe at 1 kv/µs C3 (U p) Voltage protection level line-pe for I n C2 (U p) 500 Enclosure V material Cut-off frequency (f G) Voltage protection level line-line at 1 kv/µs C3 (U p) Operating temperature range 90 V(T U) -25 Voltage protection level line-pe at 1 kv/µs C3 (U p) Test standards Degree of protection 500 V Cut-off frequency (f G) shielded RJ45 so 120 Protection MHz of the power side Pinning 1/2 Operating temperature range (T U) -25 C... Earthing via +40 C protective c Part No. Degree of protection Enclosure material IP 20 thermo SPD according to EN 61643-11 / IEC 61643-11 shielded RJ45 socket /shielded Nominal a.c. RJ45 voltage socket (U N) Pinning Test standards 1/2, 3/6, Max. 4/5, continuous 7/8 operating a.c. voltage (U C) IEC 6164 Earthing via Protection protective of the conductor power Nominal side connection load current a.c. (I L) Enclosure material thermoplastic, Nominal UL 94 discharge V-2 current (8/20 µs) (I n) DPRO Part No. Protection pure white Total discharge of current the power (8/20 µs) side [L+N-PE] (I total) SPD according to EN 61643-11 / IEC 61643-11 typ Combination wave (U Test standards IEC 61643-21 / EN 61643-21 oc) Nominal a.c. voltage (U N) Part No. 230 Combination wave [L+N-PE] (U oc total) Max. continuous operating SPD a.c. according voltage (U C) to EN 61643-11 / IEC 61643-11 255 Voltage protection level [L-N] (U Protection of the power side Nominal a.c. voltage (U p) Nominal load current a.c. (I L) N) Voltage protection level [L/N-PE] (U Nominal discharge DPRO current 230 Max. (8/20 LAN100 continuous µs) (I operating a.c. voltage p) n) (U C) Response time [L-N] (t Part No. Total discharge current 909 (8/20 Nominal 321 µs) [L+N-PE] load current (I a.c. A) total) (I L) Response time [L/N-PE] (t SPD according to EN 61643-11 / IEC 61643-11 Combination wave type (U oc) 3 Nominal / class discharge III current (8/20 A) µs) (I n) Combination wave [L+N-PE] Max. Nominal a.c. voltage (U N) 230 V (50 Total (U mains-side overcurrent protection / 60 discharge oc total) Hz) current (8/20 µs) [L+N-PE] (I total) Voltage protection level [L-N] Short-circuit Combination (U withstand capability for mains-side overcurrent p) wave (U Max. continuous operating a.c. voltage (U C) 255 V (50 protection / 60 Hz) (I oc) SCCR) Voltage protection level [L/N-PE] Combination (U p) wave [L+N-PE] (U Nominal load current a.c. (I L) 16 Temporary A overvoltage (TOV) oc [L-N] total) (U T) Characteristic Response time [L-N] (t A) Voltage protection level [L-N] (U Temporary overvoltage (TOV) p) [L-N] (U Nominal discharge current (8/20 µs) (I n) 3 ka T) Characteristic Response time [L/N-PE] (t Voltage A) protection level [L/N-PE] (U Temporary overvoltage (TOV) [L/N-PE] p) (U T) Characteristic Total discharge current (8/20 µs) [L+N-PE] (I total) Max. mains-side overcurrent 5 Response kaprotection time [L-N] (t A) Short-circuit withstand capability Temporary for mains-side overvoltage overcurrent (TOV) [L/N-PE] (U T) Characteristic Combination wave (U oc) protection (I 6 Response kv time [L/N-PE] (t SCCR) Temporary overvoltage (TOV) A) [L+N-PE] (U T) Characteristic Combination wave [L+N-PE] (U oc total) Temporary overvoltage 10 (TOV) Max. kvmains-side overcurrent protection Fault [L-N] indication (U T) Characteristic 335 V / Short-circuit withstand capability for mains-side overcurrent Voltage protection level [L-N] (U p) Temporary overvoltage 1.25 (TOV) Operating protection kv [L-N] (U T) state Characteristic indication 440 V / 12 (I SCCR) Temporary overvoltage (TOV) Voltage protection level [L/N-PE] (U Number [L/N-PE] of ports (U T) Characteristic 335 V / 1 p) 1.5 Temporary kv overvoltage (TOV) [L-N] (U T) Characteristic Temporary overvoltage (TOV) For [L/N-PE] mounting (U T) on Characteristic 440 V / Response time [L-N] (t A) 25 Temporary ns overvoltage (TOV) [L-N] (U T) Characteristic Temporary overvoltage (TOV) Test [L+N-PE] standards (U T) Characteristic 1200 V + U RE Response time [L/N-PE] (t A) Fault indication 100 Temporary ns overvoltage (TOV) [L/N-PE] (U T) Characteristic red Max. mains-side overcurrent protection Operating state indicationtemporary overvoltage (TOV) [L/N-PE] (U B 16 A T) Characteristic Customs tariff number gree Short-circuit withstand capability for mains-side overcurrent Number of ports Temporary overvoltage (TOV) [L+N-PE] (U T) Characteristic GTIN protection (I SCCR) For mounting on 1 Fault ka indication rms earthed socket outlets a Temporary overvoltage (TOV) [L-N] (U T) Characteristic Test standards Operating state indication E 335 V / 5 sec. withstand Number of ports Temporary overvoltage (TOV) [L-N] (U T) Characteristic Customs 440 tariff V number / 120 min. For mounting safe failure on Temporary overvoltage (TOV) [L/N-PE] (U T) Characteristic GTIN 335 V / 120 min. Test standards withstand 40 Temporary overvoltage (TOV) [L/N-PE] (U T) Characteristic 440 V / 5 sec. withstand Temporary overvoltage (TOV) [L+N-PE] (U T) Characteristic Customs tariff number 1200 V + U REF / 200 ms safe failure Fault indication GTIN red indicator light Operating state indication green indicator light Number of ports 1 For mounting on earthed socket outlets according to DIN 49440/DIN 49441 Test standards EN 61643-11 Customs tariff number 85363010 GTIN 4013364126152 DPRO 230 LAN100 (909 321) Surge protective device for Ethernet components (1000 BASE-T) with an elegant design Shielded Cat 5e patch cable (1.5 m) included For installation in conformity with the lightning protection zone concept at the boundaries from 222 g 1 pc(s) 11

White Paper: Surge protection for frequency converters DEHNgate DGA FF TV (909 703) Frequency range for analogue and digital TV, also suitable for reverse LAN channels Arresters of type FF and GFF with integrated measuring output Three types for adapted use in conformity with the lightning protection zone concept at the boundaries from 0 A 2 (combined lightning current and surge arresters of type GFF), 0 A 1 (lightning current arresters of type GF) and 1 2 (surge arresters of type FF) Basic circuit diagram DGA FF TV Dimension drawing DGA FF TV DGA... TV are arresters with F connection for remote supply protect 75 ohm satellite and broadband cable systems and fulfil the high shielding requirements of class A according to EN 50083-2. They allow space-saving installation in all common TV and satellite applications and are available as lightning current arresters, surge arresters as well as combined lightning current and surge arresters with integrated measuring output for testing installations. DGA FF TV Part No. 909 703 _ Max. continuous operating d.c. voltage (U C ) Nominal current (I L ) D1 Lightning impulse current (10/350 µs) (I imp ) C2 Nominal discharge current (8/20 µs) (I n ) Voltage protection level for I imp D1 (U P ) Voltage protection level for I n C2 (U P ) Voltage protection level at 1 kv/µs C3 (U P ) Frequency range Insertion loss 5-862 MHz typ. Insertion loss 862-2400 MHz typ. Insertion loss 2400-3000 MHz typ. Return loss Return loss (47-2400 MHz) Return loss test socket (5-47 MHz) Test socket connection loss Shield attenuation 5-300 MHz Shield attenuation 300-470 MHz Shield attenuation 470-1000 MHz Shield attenuation 1000-2400 MHz Characteristic impedance (Z) 24 V 2 A 0.2 ka 1.5 ka 230 V 300 V 60 V d.c. / 5-3000 MHz 1.2 db 1.4 db 2 db 14 db 18 db (-1.5 db/octave) 18 db 20 db 85 db 80 db 75 db 55 db 75 ohms Operating temperature range (T U ) -40 C... +80 C Degree of protection (if lines are connected) IP 30 For mounting on Earthing via Enclosure material 35 mm DIN rails acc. to EN 60715 or wall mounting F socket / F socket DIN rail or screw connection metal bare surface Test standards IEC 61643-21 / EN 61643-21 Approvals Accessories GOST 2x F plugs Customs tariff number 85363090 GTIN 4013364085664 233 g 1 pc(s) 12

White Paper: Surge protection for frequency converters DEHNgate DGA GFF TV (909 705) Frequency range for analogue and digital TV, also suitable for reverse LAN channels Arresters of type FF and GFF with integrated measuring output Three types for adapted use in conformity with the lightning protection zone concept at the boundaries from 0 A 2 (combined lightning current and surge arresters of type GFF), 0 A 1 (lightning current arresters of type GF) and 1 2 (surge arresters of type FF) Basic circuit diagram DGA GFF TV consisting of DGA GF TV and DGA FF TV Dimension drawing DGA GFF TV consisting of DGA GF TV and DGA FF TV DGA... TV are arresters with F connection for remote supply protect 75 ohm satellite and broadband cable systems and fulfil the high shielding requirements of class A according to EN 50083-2. They allow space-saving installation in all common TV and satellite applications and are available as lightning current arresters, surge arresters as well as combined lightning current and surge arresters with integrated measuring output for testing installations. DGA GFF TV Part No. 909 705 H_ Max. continuous operating d.c. voltage (U C ) Nominal current (I L ) D1 Lightning impulse current (10/350 µs) (I imp ) C2 Nominal discharge current (8/20 µs) (I n ) Voltage protection level for I imp D1 (U P ) Voltage protection level for I n C2 (U P ) Voltage protection level at 1 kv/µs C3 (U P ) Frequency range Insertion loss 5-862 MHz typ. Insertion loss 862-2400 MHz typ. Return loss (5-8 MHz) Return loss (8-47 MHz) Return loss (47-2400 MHz) Return loss test socket (5-47 MHz) Test socket connection loss Shield attenuation 5-300 MHz Shield attenuation 300-470 MHz Shield attenuation 470-1000 MHz Shield attenuation 1000-2400 MHz Characteristic impedance (Z) 24 V 2 A 2.5 ka 10 ka 230 V 300 V 60 V d.c. / 5-2400 MHz 1.7 db 1.9 db 10 db 14 db 18 db (-1.5 db/octave) 18 db 20 db 85 db 80 db 75 db 55 db 75 ohms Operating temperature range (T U ) -40 C... +80 C Degree of protection (if lines are connected) IP 30 For mounting on Earthing via Enclosure material 35 mm DIN rails acc. to EN 60715 or wall mounting F socket / F socket DIN rail or screw connection metal bare surface Test standards IEC 61643-21 / EN 61643-21 Approvals Accessories GOST 2x F plug Customs tariff number 85363090 GTIN 4013364105706 283 g 1 pc(s) 13

www.dehn-international.com/partners Surge Protection DEHN + SÖHNE Hans-Dehn-Str. 1 Tel. +49 9181 906-0 Lightning Protection GmbH + Co.KG. Postfach 1640 Fax +49 9181 906-1100 Safety Equipment 92306 Neumarkt info@dehn.de DEHN protects. Germany www.dehn-international.com www.dehn-international.com/partners designations of products mentioned in the white paper being at the same time registered trademarks are not especially marked. So if there is no marking of or this does not mean that the type designation is a free trade name. Neither it can be seen whether patents or utility models and other intellectual and industrial property rights are available. We reserve the right to introduce changes in performance, configuration and technology, dimensions, weights and materials in the course of technical progress. The figures are shown without obligation. Misprints, errors and modifications excepted. Reproduction in any form whatsoever is forbidden without our authorisation. activsense, BLITZDUCTOR, BLITZPLANER, DEHN, DEHN Logo, DEHN schützt, DEHNbloc, DEHNfix, DEHNgrip, DEHNguard, DEHNport, DEHNQUICK, DEHNrapid, DEHNshield, DEHNsnap, DEHNventil, HVI, LifeCheck, Red/Line are protected by German Trade Mark, by Community Trade Mark (EU) and/or in other countries.