Date Topic Release Notes Terminal Drying Unit TDNR * Nov 22, 2013 Bug fix Relevant for production only No

Similar documents
MT-SICS. Reference Manual. METTLER TOLEDO Standard Interface Command Set MT-SICS 0 version 2.2x MT-SICS 1 version 2.2x

MT-SICS. Reference Manual for

Operating instructions. METTLER TOLEDO Differential weighing software with LC-BCR Bar-Code Reader for G balances

Subset for HB43 MT-SICS. Reference Manual for

Operating Instructions. Moisture Analyzer HC103

Operating Instructions

Operating Instructions

X2 Series Balances. Innovative Functional Solutions

Operating instructions. METTLER TOLEDO MultiRange Application software IND690-Sum.

Operating Instructions

CITO2 Installation & User Instructions

Operating Instructions. Precision and Analytical Balances ML-T

Pre-installation Guide. Collect v1.0 Technical Installation Guide

Fluke Energy Analyze Release Information

TA Instruments New Features in ITCRun TM Software

R Series Balances. Innovative Technology - Even More Possibilities

XA 4Y Analytical Balances

FormToolXP Operating Instructions

LxT Version October LxT Version December LxT Version January 2014

DatabICS Manual. Employee Letter. DatabICS manual ICS Software Tool

6165 MONEY COUNTING SCALE

User s Guide. Setup+ / Webserver Configuration Tools

Compact Weighing Systems

1 Purpose. 2 New features. Release Notes tiamo 2.4

Label Flow Release Notes

AmegaView Software Release Notes

ABBYY Recognition Server 4 Release 6 Release Notes

DatabICS Manual. Employee Letter. DatabICS manual

Understanding printer messages

User Manual. Computer Program Pomiar Win. Version: 4.0.X. Manual number: ITKU A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS

Compact Weighing Systems

AS X2 Analytical Balances

Software Manual R Index 1

Firmware Revision History and Upgrade Instructions

X2 Series Balances. Innovative Functional Solutions

RMS Monitoring Software System Operation

Release Type: Firmware Software Hardware New Product. VIA Connect PRO Yes N/A

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual

Copyright ANRITSU. All rights reserved.

Security Escort Central Console Software. Table of Contents. Release Notes. Security Systems

CellAdvisor TM JD720C Cable and Antenna Release Notes for Version

Version Date Features Bug Fixes. Improved external backlighting control.

Software Update Notification

Operating instructions METTLER TOLEDO BD balances

DeltaLINK 3 Release Notes

What's new in LogTag Analyzer 2.7

Defender Multifunctional Bench Scale for Standard Industrial Applications. Washdown Bench Scales. Standard Features:

Quick Guide. bpro Retail scale

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

QSpec Software Update Notification

Security Escort Central Console Software. Table of Contents. Release Notes. Security Systems

Explosion Proof Weighing System

PS R2 Precision Balances

BALANCES BOECO BYY.A MODELS LABORATORY EQUIPMENT 18 BALANCES

Scan Station 710/730 Release Notes:

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

R Series Balances. Innovative Technology - Even More Possibilities

Moisture Analysis Balances

HI 6600 series Quick Start Guide

Microplate Absorbance Reader Labtech LT-4500

SATA DVD/CD Duplicator Controller User s Manual

Reference Manual. MT-SICS Interface Commands for Moisture Analyzers HX/HS/HC. Excellence Plus

TA Instrument Explorer. Getting Started Guide

Updating the operating system and BONGO (MCU) firmware

SensorConnect Changelog. Updated:

4-1. This chapter explains HMI settings.

DBT-120 Bluetooth USB Adapter

CHEMINSTRUMENTS DYNAMIC SHEAR TESTER MODEL DS-1000 OPERATING INSTRUCTIONS

NewClassic Balances. NewClassic ML Precise Results Compact and Portable Affordable for all Budgets. A Smart Choice for Basic Weighing

Pioneer. Analytical and Precision Balances

Release Type: Firmware Software Hardware New Product. VIA Connect PRO Yes N/A

User Manual PDUTracker

The Economical Choice of Balance for Routine Weighing Applications

-Direct.com FG-3000 Digital Force Gauge Operation Manual

2015/09/24. M-Touch

STANDARD OPERATING PROCEDURE AA SERIES AA-160 PRECISION BALANCE

Prisma Public Manifest

User Manual. ICS466x Explosion proof weighing solution

Installation and Configuration User's Guide

4-1. This chapter explains HMI settings.

TESSERA PROCESSOR 1.3.0

RMS Monitoring Software System Operation

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Reference Manual. MT-SICS Interface Commands for Moisture Analyzers HX / HS. Excellence Plus

Wireless laser barcode collector User's Guide DC8050= wireless barcode collector scanner & wireless data collector

GlossTools. Instruction Manual ZGM 1110 ZGM 1120 ZGM 1130

Power Consumption Measuring Software. This user's manual explains how to operate the Power Consumption Measurement Software.

Weigh Modules. Maximum Precision for Automation Fast, Flexible, Easy to Integrate

AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples

Operating Manual. Version 7.3.4

R&S AVBrun Sequencer Software. Release Notes. Firmware Version Release Notes. Broadcasting

Track & Trace. Comprehensive PCE Software Suite. From Sensor to ERP and from Carton to Pallet

Operating instructions. Comparator Balances AX64004, AX32004, AX16004

REFERENCE GUIDE. Copyright 2008 ComAp s.r.o.

Release Type: Firmware Software Hardware New Product. VIA Connect PRO Yes N/A

MEASUREMENT UTILITY SOFTWARE FD-S2w

AG01 Run Quick Guide V1.0

Code Reader 900FD Configuration Guide

Operating Instructions. EasyDirect Pipette Asset Management EasyDirect PAM

TA Instruments New Features in TAM Air Assistant TM and TAM Assistant TM Software

Transcription:

METTLER TOLEDO Mettler-Toledo GmbH Laboratory Weighing Address Im Langacher 44, 8606 Greifensee, Switzerland Phone +41-44-944 36 36 Fax +41-44-944 31 90 E-mail support.labtec@mt.com Release date Sep 20, 2017 Firmware Release Chart Halogen Moisture Analyzer HX204 Date Topic Terminal Drying Unit TDNR * Sept 20, 2017 Bug fix See release notes on Annex 2.22 2.22 1.40 No update needed Jan 26, 2017 Bug fix See release notes on Annex 2.21 2.21 1.40 No Jan 23, 2017 FW update & bug fix See release notes on Annex 2.20 2.20 1.40 No Oct 15, 2015 Bug fix See release notes on Annex 2.13 2.13 1.31 No Dec 19, 2014 Bug fix See release notes on Annex 2.12 2.12 1.30 No Sept 30, 2014 Bug fix See release notes on Annex 2.11 2.11 1.30 No July 1, 2014 FW update & bug fix See release notes on Annex 2.10 2.10 1.20 No Nov 22, 2013 Bug fix Relevant for production only 2.02 1.10 No Nov 07, 2013 Bug fix Fixes for SmartCal test display 2.01 1.10 No Nov 01, 2013 Dec 19, 2012 FW update & bug fix FW update & bug fix A4/Letter print outs, network connectivity, PDF reports, automatic SmartCal normalization, RHT sensor, SOC delay, AutoMet, FreeFactor. Bug Fixes. MT-SICS commands, acoustic feedback, new export functions. Improved test measurement, step drying and FW upgrade process. Bug Fixes. 2.00 1.10 No 1.20 1.10 No July 26, 2012 Bug fix Fixes in Russian and Japanese translations 1.10 1.00 No April 18, 2012 Initial Version HX204 1.00 1.00 No The information contained in this document has been collected to the best of our knowledge and represents the latest update. Company name: Mettler-Toledo GmbH Date: September 20, 2017 Laboratory Weighing Function: Head of SPG Moisture Signature: Y. Appoldt * For TDNR (type definition number) update, please contact your service technician. Page 1 of 5

Terminal Firmware V2.22, Drying Unit Firmware V1.40 ANNEX 2.22 New in firmware version 2.22 More details in event log Fixed defects in firmware version 2.22 Startup problems due to corrupted database (e.g. after FW update, factory reset) See V2.20 Terminal Firmware V2.21, Drying Unit Firmware V1.40 ANNEX 2.21 Fixed defects in firmware version 2.21 In terminal firmware V2.20 the door button was deactivated during the SetupWizard See V2.20 Page 2 of 5

Terminal Firmware V2.20, Drying Unit Firmware V1.40 ANNEX 2.20 General Notes USB WiFi Adapter should be removed for FW update/downgrade New in firmware version 2.20 Connectivity o WiFi Support: connect to a network through WiFi o MT-SICS over network: Send MT-SICS commands through WiFi or Ethernet o Gutenberg strip printer support: connect RS-P5x printers o USB Barcode reader support Compliance o Method versioning: Changes in methods are now visible in the results: results obtained with previous versions are greyed out. o Method selection: Methods can be activated/deactivated for each user o Configurable strip printout: User can customize what information is shown on the strip printout o "More data" section: Method parameters are also shown o Repeatability test: Guided test functionality with possibility to print the result (strip only) SmartCal enhancements: o Test temperature can be chosen in the testing menu o Testing temperatures can be deactivated for users Varia o Setup wizard o Instrument tutorial o Enhanced shortcut management: Dedicated menu for managing shortcuts o Screen saver o Enhanced date/time information on exports and printouts o Enhanced speed for data transfer with LabX direct Fixed defects in firmware version 2.20 SmartCal: o Erroneous control limit message when customer temperature is used in SmartCal test Weight test/adjustment: o FACT history is now correctly listed under weight adjustment history o Cancel button while taring in weight test/adjustment (internal/external) is now working properly Print / export: o PDF reports: results in the table cannot deviate from the graph o Support for auto export and auto print enabled at the same time (Fix of Known issues V2.13 and V2.12) o Print button is now disabled if no results are available o Prefix for export of results can now be removed Varia: o Improved handling of long IDs and names (containing special characters) o Creation of duplicate IDs is no longer possible in ID management o Popup messages now contain unambiguous messages o Instrument stops working if terminal crashes, this was not always the case in previous versions Exporting more than 150 results in PDF summary report might lead to error - If a high number of results are being exported to one PDF summary report there is a possibility that a memory error message pops up. The device needs to be rebooted in order to operate again leading to loss of the report. Workaround: Split results by using result filters in order to export max. 150 results to one PDF summary report. Page 3 of 5

Terminal Firmware V2.13, Drying Unit Firmware V1.31 ANNEX 2.13 Test Weight Range (Change is applicable for legal for trade instruments only) - Tare functionality adapted in weight test mode according requirements for legal for trade instruments. Improvement internal calibration - In previous versions it was possible that a user executed an internal calibration that was not performed but prematurely aborted (error message Unstable weight. The test has been aborted. ). This issue is fixed. See V2.12 Terminal Firmware V2.12, Drying Unit Firmware V1.30 ANNEX 2.12 SW Stability improvements - Software 2.12 brings significant improvements with 'sensor connection lost' and stability issues. Crash when both auto print and auto export are enabled - The unit can crash when both A4 auto printing and auto export as pdf are enabled simultaneously. Workaround: Only one of those options can be enabled or export to CSV when auto printing to A4 is active. Page 4 of 5

Terminal Firmware V2.11, Drying Unit Firmware V1.30 ANNEX 2.11 Sensor Connection Lost Error - In previous software versions it was possible that the sensor would disconnect from the terminal, this issue has been significantly improved in SW version 2.11 Identification Management - Entering and automatic deletion of identifications is now possible without administrator access rights. Language Support - Exported CSVs are now optimized for opening in Excel (Languages other than English). CSV files can now be opened in Excel by double clicking and the characters are displayed correctly. - A4 pdf reports in Chinese are now smaller (file size) and are exported faster Networking - All network related settings are now correctly reset after a factory reset of the device Reboot after disconnected printer - The issue where occasionally attempting to print an A4 pdf report of a weight test or adjustment the unit will reboot if the printer becomes suddenly disconnected from the device has been solved Terminal Firmware V2.10, Drying Unit Firmware V1.20 ANNEX 2.10 Auto Delete - A new feature that will automatically delete the oldest measurement data on the device once a certain limit (stored records) is reached. - This feature will be automatically activated upon updating to SW revision to 2.10 (or later) from a version older than 2.10. Sensor Lost Error - In previous software versions it was possible that the sensor would disconnect from the terminal, this issue has been improved in SW version 2.10 Color printer support & fixes - OKI C531dn A4 color printer supported - Letter format now supported - Optimized report printing (colors of graphs previously printed too weak etc.) Temperature test 0.1 C - For temperature tests and adjustments temperature values are presented in 0.1 C increments. Temperature Test Range - The test temperature can now be selected in the range of 50 C and 200 C Test Weight Range - The range of supported weights for the external weight test is now between 0.1 g and 201 g. - Overload tolerance when testing at capacity is opened to that an overload error is avoided when testing with weights slightly larger than capacity SmartCal lot number saved - The SmartCal test lot number is now shown in results in all printouts and exports RHT Sensor ID saved -The RHT-Sensor ID is now shown in results in all printouts and exports Progress Indication - A progress indication in percent is now shown in all instances where a busy indicator is shown (e.g. software update, data export and delete operations) Miscellaneous features and performance optimizations - Various performance, stability, and usability enhancements Page 5 of 5