NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B

Similar documents
Next Generation Firewall

Next Generation Firewall

Next Generation Firewall

Stonesoft Next Generation Firewall. Hardware Guide Models 5201, 5205, Revision C

Next Generation Firewall

Stonesoft Next Generation Firewall. Hardware Guide Models 3201, 3202, 3205, 3206, 3207, 3301, Revision F

Next Generation Firewall

Dell Storage Center. Owner's Manual. SC9000 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

StoneGate SG-200 Appliance Installation Guide

Dell PowerEdge R630. Owner's Manual. Regulatory Model: E26S Series Regulatory Type: E26S001

Dell PowerEdge R230 Owner's Manual

Dell PowerEdge R620. Owner's Manual. Regulatory Model: E16S Series Regulatory Type: E16S001

Dell PowerEdge T330 Owner's Manual

Dell PowerEdge R230 Owner's Manual

Dell PowerEdge R430. Owner's Manual. Regulatory Model: E28S Series Regulatory Type: E28S001

Dell PowerEdge R630 Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Citrix NetScaler 10 Quick Start Guide: MPX 5500 Platform

Polycom RAS200A. Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide

Dell PowerEdge T430 Owner's Manual

Dell PowerEdge R430 Owner's Manual

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

GigaStor Upgradeable 2U. User Guide

DX 32xx and DX 36xx Quick Start

Dell PowerEdge T420 Systems Owner's Manual

Dell PowerEdge R320 Systems Owner's Manual

Dell EMC Storage MD1280 Enclosure Owner's Manual

Rack Mount LCD KVM Assembly. Installer/User Guide

McAfee Network Security Platform

DX Application Acceleration Platform Quick Start

Cascade Sensor Installation Guide. Version 8.2 March 2009

Hardware Guide. McAfee MVM3200 Appliance

HP BladeSystem c-class Enclosure Troubleshooting Guide

Dell PowerEdge R620 Owner's Manual

SSL-1030 SSL Appliance Installation Guide

IPS-1030 IPS Appliance Installation Guide

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Codian IP VCR IP VCR 2200 Series

Dell PowerEdge R920 System Owner's Manual

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

Installing the IPS 4345 and IPS 4360

RDX QuikStation System Components

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Dell PowerEdge R520 Owner's Manual

Dell Storage NX430 Network Attached Storage (NAS)

DNS-2608 Enterprise JBOD Enclosure User Manual

Cascade Express Installation Guide. Version 8.2 March 2009

Dell SC7020 Storage Controller Getting Started Guide

QUICK START GUIDE 7000 SERIES DEVICES

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

QUICK START GUIDE 7000 SERIES DEVICES. 3D7010/7020/7030 (Chassis: CHRY-1U-AC) 3D7115/7125, AMP7150 (Chassis: GERY-1U-4C8S-AC)

IPS Appliance Installation Guide

Dell EMC Data Domain Hardware Features and Specifications Guide

Back-UPS RS APC Back-UPS RS 800VA 120V Black

HPE Intelligent Power Distribution Unit Installation Instructions

User Manual - KVM Rear Kit Version

IPS-1302 Series. Appliance Installation Guide

Citrix NetScaler 9.3 Quick Start Guide: SDX 17550/19550/20550/21550 Platform

EATON 5S 850/1200/1600

Unified Office Gateway UMG Quick Installation Guide. Version: 1.0

Dell PowerEdge R330 Owner's Manual

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Toll Free: Tel: Fax:

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

FW-1300 Series. Appliance Installation Guide

Dell XPS 14z Owner s Manual

Preparing to Install the VG248

G3-APEX-ENT-32T. Apex technical specifications. Parts list

Dell SCv3000 and SCv3020 Storage System Owner s Manual

ReadiManager SE200. Getting Started Guide

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Integrated LCD KVM Switch. Installer/User Guide

Dell PowerEdge R710 Systems Hardware Owner s Manual

IndigoVision Enterprise NVR-AS 4000 Linux Appliance. Quick Start Guide

Polycom ReadiManager SE200 Getting Started Guide

Quick start guide for p5 520 ( )

USER GUIDE. For more information visit

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Allworx 24x Service and Troubleshooting Guide

dedicated KVM switch and rackmount screen technology User Manual CV-801 PS/2 DB-15 KVM Designed and manufactured by Austin Hughes

G3-GSP-2P100-8TSSD Hardware Installation

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

SSL Appliance Installation Guide

Manager Appliance Quick Start Guide

IPS265T / IPS275T. TimeIPS Server. Installation Guide

IBM Systems. Quick start guide for IBM System p5 505 ( )

Deploy the ExtraHop Discover 3100, 6100, 8100, or 9100 Appliances

LifeSize ClearSea Installation Guide August 2012

ReadyNAS OS 6 Rack-Mount Hardware Manual

Intelligent Time Code Distribution Amplifier IBU-160i. Operation and Maintenance Manual P/N: REV A

Sidewinder Control Center. Hardware Guide Models C1015, C2050, and C3000. Revision C

Label Printer QL-810W/820NWB. Quick Setup Guide (English)

Dell OptiPlex All-in-One. Stand Installation Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

MODEL NUMBER: B IP2

Installation Job Aid for Ethernet Routing Switch 3600 Series

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Transcription:

NGFW Security Management Center Appliance for Forcepoint Next Generation Firewall Hardware Guide Revision B

Contents Introduction on page 2 Find product documentation on page 2 Supported software on page 2 Front panel on page 3 Back panel on page 9 Precautions on page 10 Install the appliance on page 11 Perform maintenance on page 13 Introduction Thank you for choosing a Forcepoint NGFW Security Management Center Appliance (SMC Appliance). Familiarize yourself with the appliance ports and indicators and learn how to install the appliance safely. Find product documentation On the Forcepoint support website, you can find information about a released product, including product documentation, technical articles, and more. You can get additional information and support for your product on the Forcepoint support website at https://support.forcepoint.com. There, you can access product documentation, Knowledge Base articles, downloads, cases, and contact information. Supported software The SMC Appliance centrally manages Forcepoint Next Generation Firewall (Forcepoint NGFW) engines. The Management Server and a Log Server are integrated with the hardware and the operating system as a dedicated server appliance. The SMC Appliance supports these software versions: SMC Version 6.2 and later Forcepoint NGFW Supported engine versions depend on the SMC version. See the release notes for more information. 2

Front panel The front panel has several hard drives and ports. Figure 1: SMC Appliance front panel 1 2 3 4 5 6 7 8 1 Power button and power-on indicator light 2 NMI button 3 System identification button 4 VGA out 5 LCD panel buttons 6 LCD panel that displays the appliance ID, status information, and system error messages 7 USB port 9 Note: You can use the port either as a regular USB 2.0 port or for accessing integrated Dell Remote Access (idrac) features. 8 USB port (USB 2.0 compliant) 9 Hard drives Each hard drive has two indicators that show hard drive status and activity. 3

Figure 2: Hard drive indicators 1 2 1 Hard drive status indicator 2 Hard drive activity indicator The activity indicator is on when the hard drive is in use. Table 1: Status indicator colors for hard drives Status and color Flashes green twice per second Off Description Flashes when identifying the hard drive or preparing the hard drive for removal. The hard drive is ready for insertion or removal. Note: The hard drive status indicator remains off until all hard drives are initialized after the SMC Appliance is turned on. The hard drives are not ready for insertion or removal during this time. Flashes green, amber, then turns off Flashes amber four times per second Flashes green slowly Steady green Flashes green for three seconds, amber for three seconds, then turns off after six seconds Indicates that the hard drive is likely to fail soon. The hard drive failed. The hard drive is rebuilding. The hard drive is online. The hard drive rebuild stopped. 4

Front panel buttons There are several buttons on the front panel. Figure 3: Power, NMI, and system identification buttons on the front panel 1 2 3 1 Power button and power-on indicator light Press the power button to turn the SMC Appliance on or off. The indicator on the button shows if the power is on. 2 NMI button Used to troubleshoot the SMC Appliance software and SMC Appliance driver errors. Use the end of a paper clip to press the NMI button. CAUTION: Use this button only if instructed to do so by Forcepoint support. 3 System identification button Used to locate the SMC Appliance in a rack. When you press the button, the LCD panel on the front panel and the SMC Appliance status indicator on the back panel flashes until you press the button again. Press to toggle the system ID on and off. Note: If the SMC Appliance stops responding during POST, press and hold the button for more than five seconds to enter BIOS progress mode. To reset idrac (if it is not disabled in the idrac settings), press and hold the button for more than 15 seconds. Make sure that the system ID button is enabled in the idrac setup. LCD panel features The LCD panel allows you to view status information and messages about the SMC Appliance. You can use the LCD panel buttons to scroll the information that is shown in the LCD panel. The LCD panel provides information on the SMC Appliance and status and error messages to indicate if the SMC Appliance is operating correctly. For more information on error messages, see the third-party documentation at http://www.dell.com. 5

Figure 4: LCD panel buttons 1 2 3 1 Left Moves the cursor back in one-step increments. 2 Select Selects the menu item highlighted by the cursor. 3 Right Moves the cursor forward in one-step increments. During message scrolling: Press and hold the button to increase scrolling speed. Release the button to stop. Note: The display stops scrolling when you release the button. After 45 seconds of inactivity the display starts scrolling. The backlight color of the LCD panel indicates the status of the SMC Appliance. Table 2: LCD panel backlight colors Status Color Description On Blue Amber The LCD backlight is blue when the SMC Appliance is working correctly. When the SMC Appliance needs attention, the LCD backlight is amber. The LDC panel also displays an error code followed by descriptive text. Note: If the SMC Appliance is connected to a power source, the LCD panel backlight is amber regardless of whether the SMC Appliance is turned on or off. Off The LCD backlight turns off when the SMC Appliance is in standby mode. To turn the backlight on, press any of buttons on the LCD panel. Note: The LCD backlight remains off if LCD messages are turned off through the idrac utility, the LCD panel, or other tools. Using the Home screen Use the Home screen to view user-configurable information about the SMC Appliance. The Home screen is displayed during the normal operation of the SMC Appliance, when there are no status messages or errors. When the SMC Appliance is in standby mode, the LCD backlight turns off after a few minutes of inactivity, if there are no error messages. 6

Steps 1) To view the Home screen, press one of the three navigation buttons (Select, Left, or Right) on the LCD panel. 2) To navigate to the Home screen from another menu: a) Press and hold the navigation button till the up arrow is displayed. b) Navigate to the using the up arrow. c) On the Home screen, press the Select button to enter the main menu. The Setup menu Use the Setup menu to configure idrac settings, error message format, and default information displayed on the Home screen. The following options are available in the Setup menu. Note: When you select an option in the Setup menu, you must confirm the option before proceeding to the next action. Table 3: Setup menu options Option idrac Set error Set home Description Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain addresses. Two separate DNS entries are available. Select SEL to view LCD error messages in a format that matches the IPMI description in the SEL. This enables you to match an LCD message with an SEL entry. Select Simple to view LCD error messages in a simplified user-friendly description. For more information about error messages, see the third-party documentation at http://www.dell.com. Select the default information to be displayed on the Home screen. The View menu Use the View menu to view information on the status and settings of the SMC Appliance. The following options are available in the View menu. Note: When you select an option in the View menu, you must confirm the option before proceeding to the next action. 7

Table 4: View menu options Option idrac IP Error History MAC Name Number Power Temperature Description Displays the IPv4 or IPv6 addresses for idrac8. Addresses include DNS (Primary and Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet). View information on error situations on the SMC Appliance. Displays the MAC addresses for idrac, iscsi, or Network devices. Displays the name of the Host, Model, or User String for the SMC Appliance. Displays the Asset tag or the Service tag for the SMC Appliance. Displays the power output of the system in BTU/hr or Watts. You can configure the display format in the Set home submenu of the Setup menu. Displays the temperature of the system in Celsius or Fahrenheit. You can configure the display format in the Set home submenu of the Setup menu. 8

Back panel The back panel has ports and power supplies. Figure 5: SMC Appliance back panel 1 2 3 4 5 6 7 8 9 10 11 12 13 1 Serial port Note: Additional configuration is required to activate the serial console. See Knowledge Base article 14763. 2 Ethernet port 1 (not used) 3 idrac port for accessing integrated Dell Remote Access (idrac) features For more information about idrac, see the third-party documentation at http://www.dell.com. 4 P1 management port Configure this port as the main management interface when you configure the SMC Appliance. 5 P2 management port You can optionally configure this port as the secondary management interface when you configure the SMC Appliance. 6 VGA out 7 Ethernet port 2 (not used) 8 USB port (USB 2.0 compliant) 9 USB port (USB 3.0 compliant) 10 System identification port Use the system identification port to connect the system status indicator assembly through the optional cable management arm. 11 System identification button 12 Ethernet ports 3 and 4 (not used) 13 Power supplies 1 and 2 CAUTION: Do not replace power supplies. Only the manufacturer's qualified technician is allowed to replace and service power supplies. 9

The power supplies have a translucent handle. The color of the handle indicates the status of the power supply. Table 5: Status indicator colors for power supplies Status and color Green Flashing green Flashing amber Unlit Description A power source is connected to the power supply and the power supply is operational. The power supply firmware is being updated. There is a problem with the power supply. No power source is connected to the power supply. Precautions The precautions provide safety guidance when working with Forcepoint appliances and electrical equipment. Safety precautions Read the safety information and follow the procedures whenever you are working with electronic equipment. CAUTION: Forcepoint appliances cannot be serviced by end users. Never open the appliance covers for any reason. Doing so can lead to serious injury and void the hardware warranty. General safety Follow these rules to ensure general safety. Keep the area around the appliance clean and free of clutter. The appliance weighs approximately 19.9 kg (43.13 lbs) when fully loaded. When lifting the appliance, two people at each end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs. Use a regulating uninterruptible power supply (UPS) to keep your system operating if there is a power failure and to protect the appliance from power surges and voltage spikes. If you need to switch off or unplug the appliance, always wait at least five seconds before turning on or plugging in the appliance again. Operating precautions Do not open the power supply casing. Only the manufacturer's qualified technician can access and service power supplies. Keep the cover in place when the appliance is on to ensure proper cooling. Failure to adhere to this guidance could void your warranty. Additional safety information can be provided upon request. 10

Electrical safety precautions Follow basic electrical safety precautions to protect yourself from harm and the appliance from damage. Know the locations of the power on/off button and the emergency turn-off switch, disconnection switch, or electrical outlet for the room. If an electrical accident occurs, you can quickly turn off power to the system. When working with high-voltage components, do not work alone. Turn off the system and disconnect the power before removing or installing system components that are not hot-swappable. When working with electrical equipment that is turned on, use only one hand. This is to avoid making a complete circuit, which causes an electric shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards the tools come into contact with. Do not use mats designed to decrease electrostatic discharge as protection from electric shock. Instead, use rubber mats that have been designed as electrical insulators. The power supply cable must include a grounding plug and must be plugged into a grounded electrical outlet. Use only the cords supplied with the appliance. Install the appliance Prepare and install the appliance in your network. Rack-mount the SMC Appliance Use the rack-mounting kit included in the SMC Appliance delivery to install the appliance into a four-post 19-inch rack. Follow the rack-mounting instructions provided with the rack-mounting kit. You can use the rack-mounting kit included in the SMC Appliance delivery with most industry-standard rack cabinets. Use tie wraps to secure the cables from the SMC Appliance to the rack. Note: The rack-mounting procedure varies depending on the type of rack unit. If needed, see the documentation for your rack unit. The SMC Appliance has a 1U rack height and the following dimensions: Depth 60.7 cm (23.9 in.) Width 48.2 cm (18.97 in.) Height 4.28 cm (1.69 in.) Weight (maximum configuration) 19.9 kg (43.13 lbs) CAUTION: To avoid injury, do not attempt to lift the SMC Appliance by yourself. Always use two people to lift the SMC Appliance. 11

Connect the cables Connect the management network cable and power supply cables. Before you begin Mount the SMC Appliance in the rack. For network cables, the type of cable and network interface settings depend on the type of network. Use at least CAT5e-rated cables for gigabit networks. Network interfaces at both ends of each cable must have identical speed and duplex settings. These settings include the automatic negotiation: if one end of the cable uses autonegotiation, the other end must also use autonegotiation. Steps Note: Gigabit standards require interfaces to use autonegotiation fixed settings are not allowed at gigabit speeds. 1) Plug a management network cable into port P1 on the back panel of the SMC Appliance. 2) If you have configured the secondary management interface, plug a management network cable into port P2 on the back panel of the SMC Appliance. 3) Plug the power supply cables into the back panel of the SMC Appliance, then plug the other end of the cables into a power source. We recommend that you plug in both power supply cables to ensure that the SMC Appliance functions if one power supply fails. Use a UPS to ensure continuous operation and minimize the risk of damage to the SMC Appliance in the case of sudden loss of power. For a redundant power supply, connect each power supply cable on the SMC Appliance to a different UPS, so that the failure of one UPS does not cut power to both power supplies. 4) Connect the monitor and keyboard to the back panel or the front panel of the SMC Appliance. Note: The SMC Appliance supports only a USB-compliant keyboard. 5) Turn on the SMC Appliance. Next steps Continue the SMC Appliance configuration as described in the Forcepoint Next Generation Firewall Installation Guide, version 6.2 or later. 12

Configure idrac on the SMC Appliance Configure integrated Dell Remote Access (idrac) on the SMC Appliance to allow you to connect remotely to the SMC Appliance. Steps 1) While the SMC Appliance is starting, press F2 to enter the BIOS configuration screen. 2) Select idrac Settings, then press Enter. 3) Select Network, then press Enter. 4) Configure the Static IP Address, Static Gateway, and Static Subnet Mask fields, then press Esc. 5) On the idrac Settings screen, select User Configuration, then press Enter. 6) Configure a user name with administrator rights, set a password, then press Esc. 7) Select Yes, then press Enter to save the changes. 8) Connect a network cable to the idrac port on the back panel of the SMC Appliance. 9) Access the configured IP address from another computer. 10) Log on to idrac with the administrator credentials that you set. Perform maintenance The SMC Appliance might require maintenance for optimal performance. Only the manufacturer's qualified technician is allowed to service or replace most of the components in the SMC Appliance. You can perform the following maintenance tasks if instructed to do so by Forcepoint support: Replace a hard drive with a new hard drive provided by Forcepoint. See Knowledge Base article 12504. Re-image the SMC Appliance. See Knowledge Base article 12505. If you need to replace any other components or have any issues with the SMC Appliance hardware, contact Forcepoint support. Turn off the SMC Appliance If needed, you can turn off the SMC Appliance. Steps 1) Connect to the SMC Appliance command line. Use one of these options. Connect a keyboard to a USB port and a monitor to the VGA port, then press Enter. Connect to the IP address of the idrac port and start the virtual console on the Server Properties tab. 13

Connect using SSH. Note: Do not use SSH in FIPS mode. 2) Enter the logon credentials. The user name and the password are the ones you set for the SMC Appliance during the installation. 3) Enter the command sudo shutdown -P now to power down and turn off the SMC Appliance. 14

2017 Forcepoint Forcepoint and the FORCEPOINT logo are trademarks of Forcepoint. Raytheon is a registered trademark of Raytheon Company. All other trademarks used in this document are the property of their respective owners.