NMR Spectroscopy with VnmrJ. University of Toronto, Department of Chemistry

Similar documents
VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400

VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS

Agilent VnmrJ 3.2. Quick Start Guide

VnmrJ Walkup. Varian NMR Spectrometer Systems With VnmrJ 1.1D Pub. No , Rev. 0604

North Carolina State University Department of Chemistry Varian NMR Training Manual

NMR Training VNMRJ 4.2A/VNMRS 400

NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation

NMR Spectrometer Crib-Sheet

c. Saturday and Sunday: 10 minute time blocks and unlimited time.

Bruker Avance 400 MHz Instructions

General Information for Automated Inova 500 MHz NMR (Indy)

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751)

Vanderbilt Small Molecule NMR Center

VnmrJ Walkup. Varian, Inc. Inova and MercuryPlus NMR Systems With VnmrJ 2.2D Software Pub. No , Rev. A 0808

Varian Solution NMR Procedure

Walkup NMR. Varian NMR Spectrometer Systems With VNMR 6.1C Software. Pub. No , Rev. A0800

Varian Solution NMR Automation Procedure (VNMRS Machines running VNMRJ 4.2 under Red Hat Enterprise 5.1)

NMR Users Guide Organic Chemistry Laboratory

Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 DISCLAIMER

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin.

PROCESSING 2D SPECTRA USING VNMRJ JB Stothers NMR Facility Materials Science Addition 0216 Department of Chemistry Western University

Instructions for 1 H-, 13 C-, 19 F-, and 31 P-Spectra on the Varian Mercury-Vx-300

IMSERC NMR MANUAL 02: Basic Processing of Varian 1D NMR Data

Quick Guide to Topspin

PINMRF. Varian 300 MHz NMR Spectrometers Training Guide for Basic 1D NMR Spectroscopy

Bruker NMR Topspin Manual

DCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015

MNova Version Installation Instructions.

Varian Solution NMR Automation Procedure

Bruker Topspin NMR Training Manual

Routine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer

Frequently Asked Questions (FAQ)

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR

Agilent VnmrJ 3.2 Automation

Delta V5 operation. Widetron Technologies Corp. Wu, Chung Ying. Progress through Synergy

Bruker AVANCE III HD 400 MHz Spectrometer Operation

NMR Data Acquisition and Processing Procedure

Troubleshooting Acquisition Related Problems

DCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015

Nicolet is50 FTIR User s Booklet

UC DAVIS NMR FACILITY VNMRJ SHORT MANUAL FOR VARIAN/AGILENT NMR SPECTROMETERS

Acquiring Data in VnmrJ 4.2A

MestReC Cheat Sheet. by Monika Ivancic, July 1 st 2005

DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400

Open Access Manual for Superusers

Basic 1D Processing. Opening Saved Data. Start the VnmrJ software. Click File > Open.

CHEMISTRY DEPARTMENT Category Work Instruction

EQNMR Facility Rules of Use

TOCSY 15. Goto. Introduction Pulse Sequence Diagram AVANCE User s Guide Bruker 167

NMR Spectroscopy with VNMRJ & EZ NMR

Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12

Gemini-300, Manual Operation (version 1.0, 4Feb95) 1

ONE DIMENSIONAL NMR SPECTROSCOPY. DPX 200 and DPX 300

T 1 Relaxation Measurement: The Inversion-Recovery Experiment (Using IconNMR) Revised

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy

Processing data with Bruker TopSpin

VNMRJ 2.1B Quick overview and BioPack features

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

VnmrJ 3.2: Industry-Leading Software for NMR Spectrometers

Basic Procedure 1D NMR Data Collection

CSImage Tutorial v August 2000

DCIF NMR Training Guide Varian Mercury 300 MHz Last Update

15. HOMONUCLEAR COSY

1. Log in at the RESLOG terminal by entering your code and select the instrument you want to use.

Fitting NMR peaks for N,N DMA

Varian NMR Instructions - 1D. Department of Chemistry NMR Facility University of Minnesota

Galaxie Photodiode Array Software

UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X

CONTENTS 1D EXPERIMENTS D EXPERIMENTS APPENDIXES... 83

Automation. User Guide Pub. No Rev. A 01/22/10

Vnmrj 3.1 New and improved features

On Artemis and Cronus, make sure you are adjusting the db scale and not the watts

1D and 2D Experiments Step-by-Step Tutorial

Before you get started, make sure you have your section code since you ll need it to enroll. You can get it from your instructor.

ADVANCED DATA PROCESSING

IconNMR Operating Procedures

SIVIC GUI Overview. SIVIC GUI Layout Overview

Quick Start Guide to nmrpipe Processing of 15 N-HSQC data

How to analyze complex NMR signals through spin simulation/iteration

Chemical Shift Perturbation Tutorial

Agilent EZChrom Elite. PDA Analysis

Modify Panel. Flatten Tab

Using HyperChem for CH 463. Chun Park

University of Minnesota Nano Fabrication Center Standard Operating Procedure

Work with RSS Feeds. Procedures. Add an RSS Text Object CHAPTER. Procedures, page 7-1

Controlling the Drawing Display

Galaxie Report Editor

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

TopSpin 1.3 patch level 10. DPX 200, DPX 300 and DRX 500. Windows XP

Make a Map. 1) Log in to BrainPOP as a student or teacher. 2) Visit a topic page and click the MAKE A MAP button.

Operating Procedure for Horiba Raman Microscope

Running Multiple Experiments on the Same Sample Automatically. (multizg, spooler/queue, iconnmr)

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

Welcome to the NMR Center

Autodesk Inventor Design Exercise 2: F1 Team Challenge Car Developed by Tim Varner Synergis Technologies

DCIF FAQ: Frequently Asked Questions Varian Last Update (2/21/2005)

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

SystemVue 2011 Fundamentals (version ) LAB EXERCISE 1. SystemVue Basics

NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington XWINNMR 3.5 TRAINING NOTES. 08/8/2005 rajan paranji

Transcription:

NMR Spectroscopy with VnmrJ University of Toronto, Department of Chemistry

Walk-up interface 1 Logging in 1 Starting VnmrJ 1 Inserting sample into the magnet or sample changer 1 Enter sample information 1 Experimental Protocol Tabs 2 Select Experiments from the Experimental Protocol Tabs 2 Changing acquisition parameters 2 Submit Study Queue 3 Submit another sample 3 Follow progress of spectra 3 Data saved automatically 3 Processing 1D data 3 Load FID 3 Spectra Display tools (from Varian) 4 Command line 5 Using the mouse 5 Expansions 5 Display 5 Manually phasing the spectrum 6 Referencing a peak 6 Baseline correction 6 Integrating 6 Threshold 7 Plotting spectra 7 Log out 7 Online help 7 Advanced topics 8 Manual locking 8 Gradient shimming 9 Shimming 9 August 21, 2006 5:31 PM

Walk-up interface Logging in Log into Solaris. You will have your own username and password. Do not use another person s username and password and do not share your username and password. Shared accounts will be deleted. Starting VnmrJ In Solaris, click on the VnmrJ icon in the CDE bar: Inserting sample into the magnet or sample changer Use clean NMR tubes The optimal solvent height is 4 cm; use about 750 µl of solvent in a 5-mm tube For best shimming, the sample should be free of undissolved particulate material Filter the sample, if necessary, through glass wool or celite Put the sample part-way into the spinner then position in the depth gauge Take care not to break the tube when putting into the spinner If the solvent height is shorter than recommended, pull the tube up to centre the sample on the middle line Turn the eject air on by pressing the Eject button (Start tab, Study page) The air should be on: Do not proceed if the eject air does not turn on! Put the sample into the magnet upper barrel. It should float at the top now On the Varian 400, do not touch or rotate the carousel sample changer Click Insert: The sample drops in a controlled manner into the magnet Enter sample information Put the sample information into the study. Go to the Start tab, Study page: Enter sample identification in the sample field; this will be used in the name of the saved FID Do not use characters other than a-z, A-Z, 0-9, hyphen, underscore and space Enter Notebook and Page, if desired Select the solvent from the popup menu Check Find z0 and Gradient Shim for automatic lock and shim For manually locking and shimming, go to the section Advanced Topics 1

Experimental Protocol Tabs Select experiments from the Experimental Protocol tabs: Std1D: One dimensional experiments Proton, Carbon Homo 2D: Two dimensional homonuclear experiments COSY, ROESY Hetero 2D: Two dimensional heteronuclear experiments Ghsqc, Sel1D: One dimensional selective excitation experiments Roesy1d Dosy 2D: Two dimensional diffusion experiments Select Experiments from the Experimental Protocol Tabs Select each experiment by single clicking on the Experiment protocol button Multiple experiments can be run on the same sample by clicking on the desired experiments Queued experiments are shown in the Study Queue underneath the Experiment protocol buttons Experiments are run in the order queued The order may be changed by dragging to re-arrange Experiments can be deleted by dragging to the Trash icon Changing acquisition parameters Double-click on the time field in the Study Queue of the experiment you want to customize All changes must be made before the sample is submitted Click on the Acquire tab and select the Default page: Experimental Protocols Study Queue Change the number of scans depending upon the concentration of the sample and how long you want the experiment to run The Show Time button shows the amount of time the experiment will take to run Change the spectral width to include the peaks expected On the Varian 400, peaks outside this range do not appear at all! On the Unity, Mercury and Gemini spectrometers, peaks outside this range will appear out of phase and folded into the opposite side of the spectrum Change the relaxation delay if accurate integration is required Double the delay and compare relative integration there should be no change if the delay is sufficient 2

Submit Study Queue Click the Submit button to start the experiment The experiments run in the background and shown only when finished The red Stop button in the Acquire tab stops the experiment in progress After the experiment is finished, dragging the Study Queue to Trash deletes the data! Submit another sample Another sample can be submitted after the first one is done If there is no sample changer, the samples have to be ejected and inserted manually before submitting Follow progress of spectra Double click on the time field of the experiment while the experiment is running Click on Transform all in the Default page of the Process tab Data saved automatically The data is saved automatically, using the format Date-samplename-experiment-number For example, 20060224-mysample-Proton-001 For automatic 2D processing and plotting do not change the FID names Processing 1D data Load FID To load a FID, drag the file from the File Locator to the Graphics canvas: Completed experiments from the Study Queue can also be dragged to the Graphics canvas Processing is done automatically 3

Spectra Display tools (from Varian) Cursor or Box Box Changes to the box mode with two cursors. Cursor Changes to the cursor mode with one cursor Expand or full display Expand Expands the area between the cursors Full Displays the full area Set integrals The first click displays the integral function buttons and selects partial integral display The second click displays the No Integral and Clear Resets buttons Full integral Displays all integral regions Integral resets Opens interactive integral reset mode The left mouse button defines an integral reset at the current mouse position The right mouse button removes an integral reset closest to the current mouse position The middle mouse button adjusts the vertical scale No Integral Turns off display of the integral Integral Lvl/Tlt Opens interactive zero- and first-order baseline correction mode Display Scale Displays a frequency scale under the spectrum in units specified on the Display page, usually ppm Grab and Move Opens the interactive spectral windowing mode Use the left mouse button to adjust the start of the display and move the display left or right Use the right mouse button to adjust the width of the display Threshold Toggles the display of a horizontal cursor The left mouse button positions this cursor at the mouse arrow position The middle mouse button adjusts the vertical scale Phase 4

Opens the interactive phasing mode Use the left mouse button for coarse adjustment Use the right button for fine adjustments See Phasing the spectrum, below Refresh Redraws the Graphics canvas. Return Returns to the last menu Command line To type commands, pull down the command line: Using the mouse The three mouse buttons control the cursors and the vertical height of either the spectrum or the integrals The left mouse button controls the left cursor and moves the right cursor if in box mode The right mouse button controls the right cursor (the delta) The middle mouse button controls the vertical scale of the spectrum (if No Integral is selected) If an integral is displayed (the middle value says is), the middle mouse button scales the integral Expansions When both vertical cursors are shown clicking the expand button expands the horizontal scale between the cursors When one cursor is shown the expand button becomes the full button and shows the entire spectrum in the horizontal dimension Display Click the Autoscale button to scale the tallest peak into the screen Click Full Spectrum to see the full spectrum horizontally 5

Manually phasing the spectrum Click on the Phase icon Click on the right-most peak with the left button and keep the mouse button pressed Phase that peak by dragging the mouse up and down, with the button pressed The left button is coarse and the right button fine adjust Phase only the right hand peak Click on the left-most peak and phase as you did for the right hand side Phase the left hand peak Referencing a peak Select a peak by centering the cursor on peak In the Default page of the Process tab, choose one of Reference By Solvent or By TMS or Click Find nearest line then put value in Reference cursor to Select ppm first if your are referencing to a value in ppm (like 7.26 ppm) Baseline correction For linear baseline correct click the DC Correct button.the edges of the spectrum as displayed must be flat. For non-linear baseline correct (when the baseline is curved), integrate all peaks (Find Integral button does this automatically) then click BC Correct. Integrating Click on the Set Integrals tool, then Integral Resets Integrate spectrum by: Left click cuts the integral Right click removes the cut nearest the click Select the Integration page in the Processing tab 6

Put cursor over integral trace Click Set Integral Value Click Display Normalized Integrals Threshold Click on the Threshold button Left click to adjust the threshold to intersect with the peaks to be picked Plotting spectra Select the Plot page of the Process tab Click Automatic plot page OR click as desired: Plot Spectrum Plot Spectrum Scale Plot Text Select one of Plot Peak Frequencies: On Peaks As a List None Plot Integrals Plot Normalized (integral values ) Plot Page Note: Plot Page prints those options previously clicked Log out Exit from VnmrJ (Utilities menu>exit) In Redhat Linux: Select the Actions>Log Out in the top menu In Solaris: Click Exit in the CDE bar Do NOT use Switch Operators if you logged into Solaris or Redhat Use Switch operators on the Sample Changer computer Online help Online help is available from the Help menu in VnmrJ Firefox is launched and a searchable help is shown in the browser Select Liquids in the menu: 7

Advanced topics Manual locking Find the resonance of the deuterated solvent by scanning z0: Click the Find z0 button to rapidly find the resonance (not available on Gemini or Unity) The Message window shows the new value of Z0: Select the Lock page in the Start tab Click Lock Scan button to turn on the lock display Set Lock Phase, Lock Gain and Lock Power appropriately (refer to values by the spectrometer) Keep the lock power low: a change of 6 in the lock power should result in a change of factor of 2 in the lock level. Decrease the lock power by 6. If the lock level is not ½ of the starting value, the lock power is too high. Turn the lock off Scan z0 to find the resonance exactly If you did not use find z0, the sine wave indicates the distance from resonance The yellow line should be maximum and the blue line minimum Drag the z0 slider or use ±10 or ±100 button Using the mouse: Right click increases by the value shown on the button Left click decreases by the value shown on the button Middle click changes the value shown on the button between 1, 10 and 100 8

Turn the Lock on, adjust the Lock Gain and Lock Power so the lock level is between 50 and 90. Click Lock Scan button to turn off the lock display Before Locking After Locking Gradient shimming Use gradient shimming when possible. Click on the Gradient Shim button. When the shimming has finished, the Message window (bottom right) will show a message: Shimming Select the Shim page under the Start tab: On the Varian NMR System 400, there are 24 shims. On the Varian Mercury and Gemini spectrometers, there are 14 shims. The Varian Unity, Mercury and Gemini spectrometers have Z1C and Z1 and Z2C and Z2 The Varian NMR System 400 does not have Z1C and Z2C Z1C is 50 Z1, Z2C is 50 Z2 On the Varian Mercury and Gemini spectrometers, use Z1C and Z2C Spin the sample when shimming Z1 to Z6 (usually Z1C and Z2C or Z1 and Z2 are used) Do not spin the sample when shimming any shim that has X or Y components (not routinely used) The lock level is represented by a clock The hour hand (shorter hand) represents the lock level, from 0 to 100 The minute hand (longer hand) is used to see the lock change as the shims are changed The lock level is shown the middle of the clock Clicking the blue dot shows the highest level of the lock level The lock should not be saturated (with too much power) Decreasing the lock level by 6 should change the lock level by a factor of 2 Using the mouse buttons: 9

Right click increases by the value shown on the button Left click decreases by the value shown on the button Middle click changes the value shown on the button between 1, 10 and 100 Iteratively shim: Change Z1 by +10 or -10. If the lock level increases, continue in that direction If the lock level decreases, go the opposite direction Continue changing Z1 until the lock level is maximized Some solvents (methanol, acetone) have a very slow response, so change the shims slowly wait until the lock level stops changing before clicking the shim button Change Z2 by +10 or -10 and continue in the direction that increases the lock level until the lock is maximized If the lock level reaches 100, decrease the lock gain and continue Return to Z1 and maximize the lock level, then use Z2 to maximize the lock level Iterate between Z1 and Z2 until the lock level is maximum, use ±1 as necessary If the lock level reaches 100, turn down the lock gain and continue Adjust the lock phase if a large change is made to either Z1 and Z2, the lockphase may be needed to be changed several times during shimming 10