Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Similar documents
Rhino Redundancy Module PSM24-REM360S. Operating Instructions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Rhino PSM Power Supplies. Operating Instructions

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable)

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power supply CP-C 24/5.0

PHOENIX CONTACT - 07/2006

MINI-PS AC/10-15DC/8

Industrial Power Supplies

Industrial Power Supplies

QUINT-BUFFER/24DC/24DC/40

Power supply CP-E 48/1.25 Primary switch mode power supply

Redundancy unit CP-A RU

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TRIO-DIODE/12-24DC/2X10/1X20

Industrial Power Supplies

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Power supply CP-E 24/10.0 Primary switch mode power supply

QUINT-PS-3x AC/24DC/10

STEP-PS/1AC/24DC/1.75

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Industrial Power Supplies

BUFFER MODULE SHORT-FORM DATA MARKINGS

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Industrial Power Supplies

Redundancy Module QUINT-DIODE/40

QUINT-PS AC/24DC/10

PHOENIX CONTACT - 01/2007

Industrial Power Supplies

Universal Power Supplies

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TEP 100WIR Series, 100 Watt

Power supply CP-C 24/5.0

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

ETD-BL-1T-OFF-CC- 10S

Bulletin 1606 Switched Mode Power Supplies

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Simple but elegant look and ease of installation make it ideal for various industrial applications.

Electronic timer CT-AHD.22

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Electronic timer CT-ERD.12

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Installation Instructions

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

FLEX Ex Spring Clamp Terminal Base

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

TEP 75WI Series, 75 Watt

MMA-15 series. 15W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs. Universal 90 to 264VAC Input

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

CliQ II Buffer Module 24V 20A / DRB-24V020AB

MC 11 EB-2 Power supply cabinet with external bus, AC version

PanelView Plus/VersaView CE Terminals and Display Modules

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

QUINT-PS/24DC/48DC/ 5

RT4B-110V/12A RECTIFIER

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Enclosed Power Supplies

AI561 Analog Input Module

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

QUINT-PS/ 1AC/24DC/ 5

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

RT4F-110V/25A RECTIFIER

PMT. Safety Standards. Model Number:

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

CliQ II Buffer Module 24V 40A / DRB-24V040ABN

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

CompactBlock Guard I/O EtherNet/IP Safety Modules

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Zelio Control-modular measurement and control relays 1

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

S8VE (60/90/120/180/240-W Models)

MINI MCR-SL-CVS NC

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Transcription:

Rhino Buffer Module PSM24-BFM600S Operating Instructions

RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts or voltage dips of up to ten full 50 Hz cycles (200ms at 25 amps). During this buffer period, no deterioration of the 24 VDC output voltage will occur. This buffer module is an ideal and cost effective alternative to a battery-based backup system for many applications. The buffer module consists of a large bank of capacitors. When the power supply is switched on, the buffer capacitors will be charged. This will take approximately 30 seconds. An opto-coupler signal indicates the "READY" condition. When a power failure occurs, the capacitor bank is discharged, maintaining the output of the buffer module at its nominal voltage. This condition is indicated by a "POWER FAIL" signal. The hold-up time is typically 200 ms at 25 amps and 4 seconds, typically, at 1.2 amps. After 4 seconds, the buffer device will switch off the output voltage. The operation modes of the module are also indicated by an LED on the front panel. The greatest advantage of this buffer solution is that it is fully maintenance free, and its storage capability does not deteriorate over the lifetime of the product. A PSM power supply must be connected to the load as well as to the PSM24-BFM600S module. The buffer module is in parallel to the output voltage of the PSM power supply, and charges its internal hold-up capacitors during normal operation. The charge current (<0.6 A) is taken from the power supply output itself (charging time 30 sec max). The output voltage is monitored, and if it drops below an adjusted threshold, the PSM24-BFM600S will switch off. The stored energy in the hold-up capacitors is used to keep the output voltage at the threshold level. The quiescent current is 100 ma typ (typ 2.5 W). The output voltage of the PSM power supply must be one volt higher than the threshold level adjusted by the potentiometer. The threshold level can be adjusted in two different ways: Option 1: At the factory, the PSM24-BFM600S is charged and then discharged with no load, giving the operator approximately 4s to set the threshold level. Option 2: (Less accurate) Turn the PSM24-BFM600S potentiometer fully clockwise and connect the PSM24-BFM600S to a DC supply or the PSM power supply unit set to the correct level (22.5 V for 24 VDC output voltage use). Turn the Buffer potentiometer counter-clockwise until the charging LED starts flashing Green/Red. The PSM24-BFM600S is a built-in unit. The mounting position must fulfill the requirements for fireproof enclosures, according to UL60950 IEC/EN 60950 or other appropriate national standard. The relevant UL regulations or equivalent national regulations must be observed during installation.the PSM24-BFM600S is designed for mounting on a DIN rail (DIN EN 50022-35x15/7.5).The output voltage of the PSM24-BFM600S is protected against short circuit and open circuit conditions. The module is not protected against reverse input polarity. Warning The PSM24-BFM600S built-in module is designed especially for use in process automation and other industrial applications. Components with dangerously high voltage and high stored energy are located in the device; however, these are inaccessible. Failure to properly maintain the PSM24-BFM600S can result in death, severe personal injury or substantial property damage. The PSM24-BFM600S should be installed and put into operation by qualified personnel only. The corresponding national regulations (e.g. UL, ANSI, VDE, DIN) must be observed. The successful and safe operation of this module is dependent on proper storage, handling, installation and operation. The potentiometer to adjust the output voltage must be actuated using only an insulated screwdriver, because accidental contact may be made with parts inside the power supply carrying dangerous voltages. Caution: Risk of electrical shock and electrical discharge. Only qualified and trained personnel should open the PSM24-BFM600S or the power supply. Do not open the PSM24-BFM600S or the power supply until at least 5 minutes after complete disconnection of the main power. Electrostatic sensitive device. In case of non-observance or exceeding the limiting value mentioned in these instructions, the function and electrical safety can be impaired and can destroy the PSM24-BFM600S and/or the power supply. Danger: Never work on the PSM24-BFM600S or power supplies if power is applied! Before installation ensure that the main switch is switched off and locked out. Touching of any live components or improper usage of PSM24-BFM600S or power supply can result in severe injury or death. Warning: To minimize the risk of potential safety problems, follow all applicable local and national codes regulating the installation and operation of this equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Failure to follow all applicable codes, or exceeding the limiting value can impair the function and electrical safety and destroy the power supply. Serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication to be suitable for your particular application, nor do we assume any responsibility for your product design, installation or operations. Before operating Read these operating instructions carefully and completely. Check that the input wiring is sufficiently protected and is the correct size. Check that the output wiring is rated for the maximum output current, and connected with the correct polarity. Verify that sufficient cooling is assured. Caution: The temperature of the housing can become very high, depending on the ambient temperature and load. 2 1-800-633-0405

Installation Assembly A sufficiently strong DIN rail, such as DN-R35S1, must be used. Observe the correct mounting position for optimal cooling performance. A minimum free space of 80 mm [3.15 in.] is required above and below the PSM24-BFM600S; leave a minimum space of 50 mm [1.97 in.] (which allows air convection) on each side. The air temperature, as measured 10 mm [0.39 in.] below the device, must not exceed the specified values in these instructions. The power derating above ambient temperatures of 40 C is the same as specified for the PSM power supplies. To attach PSM24-BFM600S to the DIN rail, hook top part of clip on DIN rail, then push down and inward until you hear a clicking sound. To remove the device, pull the latch of the clip using an insulated flathead screwdriver. When the clip has cleared the bottom DIN rail, remove the screwdriver from the recess. Lift the module off the DIN rail. Wall mounting or chassis mounting can be achieved by use of the optional mounting bracket, PSM-PANEL1. Remove the DIN clips by removing the screw and place the mounting brackets in the same place as the DIN clips. Use the countersink screws included with the wall mounting kit to attach the mounting brackets to the PSM24-BFM600S (tightening torque 0.8-0.9Nm). Connecting Cable Allow only qualified personnel to install the module. The device is equipped with a COMBICON connector. This reliable and easyto-assemble connection method provides a quick connection of the module. Input (Connector J1 pin 1 & pin 2) The connection is made by using the Vin and +Vin connections (connector J1 pin 1, pin 2, pin 3 and pin 4) as well as protective earth (connector J1 pin 5) following local codes and regulations. Choose correct wiring size from the Connections and Terminal Assignment table below.to achieve a reliable and shockproof connection, strip the connecting ends as listed in the following table. If flexible wires are used, terminate them using ferrules. Connections and Terminal Assignment Solid or Stranded Wires Torque Device Terminals Function Stripping mm 2 AWG Nm Length mm PSM24-090S PSM24-180S PSM24-360S PSM24-600S Protective earth conductor 0.5 to 2.5 24 to 12 0.5 to 0.6 7.0 + & - Input voltage (24 VDC) 0.5 to 2.5 24 to 12 0.5 to 0.6 7.0 Protective earth Conductor 0.5 to 2.5 24 to 12 0.5 to 0.6 7.0 + & - Output voltage (24 VDC) 1.0 to 2.5 18 to 12 0.5 to 0.6 7.0 Protective earth Conductor 1.0 to 4.0 18 to 10 0.5 to 0.6 7.0 + & - Output voltage (24 VDC) 2.0 to 2.5 12 to 10 0.5 to 0.6 8.0 Signaling (Connector J2 pin 3, pin 4, pin 5 and pin 6) The output Active is for enabling monitoring of the functions when the PSM24-BFM600S is in operation. This signal is monitored by measuring the input voltage at the input pins, and is provided by an open collector opto-coupler which can handle 10 ma maximum (see also connector J2 pin 3 and pin 4). The output Ready provides the signal when the PSM24-BFM600S is ready to provide the current (connector J2 pin 5 and pin 6). The Ready signal is provided by an open collector opto-coupler which can handle 10 ma. It is monitored by measuring the PSM24-BFM600S voltage level at the capacitors. Status LED The Status LED indicates the status of the PSM24-BFM600S module and provides visual confirmation of the function. LED Green LED Red LED Changing from Green to Red LED Green pulsing Status LED Function Normal operation, PSM24-BFM600S is ready to provide a current of 25 A max Input voltage on PSM24-BFM600S is lower than the adjusted threshold level PSM power supply is charging the PSM24-BFM600S module PSM24-BFM600S is providing output current, discharging of PSM24-BFM600S Inhibit Function The PSM24-BFM600S unit provides an Inhibit function by use of pin 1 and pin 2 at connector J2 to control the PSM24-BFM600S module. To switch off the PSM24-BFM600S, a voltage level between 5 VDC and 28 VDC is applied on connector J2 pin 1 (Inhibit GND) and connector J2 pin 2 (Inhibit +). The device is ready to provide the output current for the requested buffer time at zero voltage or a voltage level between 0 VDC and 1 VDC between J2 pin 1 (Inhibit GND) and pin 2 (Inhibit +). www.automationdirect.com 3

Compliance to UL508C The PSM24-BFM600S is a built-in device. To comply with UL 508C it must be installed in a cabinet with minimum dimensions of 400 mm (width) x 500 mm (height) x 200 mm (depth). Operating Temperature Ranges and load derating: Operating temperature ranges and load derating depend on the PSM power supply connected to the PSM24-BFM600S. Please see operating temperature range and load derating values listed in the operating instructions for the applicable PSM power supplies. Technical Specifications Part Number PSM24-BFM600S Input Specifications Input Buffer Time * Voltage Output **Max. Output Range Current 24 VDC power supply Load dependent 200 ms @ 25 A, 4 s @ 1.2 A load *Output voltage adjustable,** Maximum current at Vout nom. 22 VDC to 28 VDC 25.0 A (600 W) Buffer Module Function Diagram and Connector Positions Output Specifications Output Voltage Adjustable Range with Potentiometer Ripple and Noise (20MHz Bandwidth) At V in nom and I out max Parallel Operation 1 2 3 4 5 6 22 to 28 VDC 200 mv peak-to-peak max 2 devices possible J2 PSM Inhibit J2.2 J2.1 J1.1 J1.2 J1.3 Discharge Charge J1 J2 Pin 1 + Vin Inhibit GND Pin 2 + Vin Inhibit + Pin 3 - Vin Active GND Pin 4 - Vin Active Signal Pin 5 FG Ready GND Pin 6 Ready Signal Load J1.4 Volt adjust Active J2.4 J2.3 Voltage Detection Voltage Detection J2.6 J2.5 Ready J1 1 2 3 4 5 Buffer Time vs Load Power (typical values) 600 550 500 450 400 [W] Power Load 350 300 250 200 150 100 50 4 0 0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 3.25 3.5 3.75 4 4.25 Time [s] 1-800-633-0405

General Specifications General Specifications Electromagnetic Compatibility In correspondence to connected units (no internal switching device) Buffer Voltage Adjustable, >1 V below input voltage, min. 22 VDC. Operating Voltage Range 22 to 28 VDC Charging 0.6 A max/30s max Buffer Time 200 msec typical @ 25A max load 4.0 sec maximum @ 1.2 A load Input 24 VDC Output Power Max 25.0 A (600 W) Status Signals Buffer Active, Buffer Ready (Opto-coupler output), dual-color LED for status indication Inhibit Input Opto-coupler input: supply between 5 VDC and 28 VDC to Inhibit Dimensions HxWxD = 54.0 mm (2.43 in.) x 110.0 mm (4.33 in.) x 110.0 mm (4.33 in.) Signal Output Ratings 10 ma @24 VDC Operating (ambient): -25 C to + 70 C max (-13 F to 158 F). Above +40 C(104 F) load derating Storage (non-operating): -25 C to + 85 C max (-13 F to 185 F). Temperature Temperature drift: 0.02%/K. Cooling: convection, no internal fan Reliability, Calculated MTBF In accordance with IEC 61709 350,000 hours Humidity 95% (non-condensing) relative humidity maximum Isolation According to IEC/EN 60950, UL 60950, UL 508C, EN50178, EN61558-2-8, EN60204 Output Regulation Input variation: 0.5% maximum. Load variation (10 to 100%): 0.5% maximum Output Voltage Ripple 100 mv peak to peak typical (20 MHz bandwidth), (200 mv peak-to-peak maximum at Imax) Dual color LED Green: normal operation Red: Input voltage low Status Indicator Red-to-Green: charging Pulsing Green: discharging Remote ON/OFF 2-pin connector. J5 pin 7 and pin 8 connect via a switch Device off Vibration IEC 60068-2-6: 3 axis, sine sweep, 10-55 Hz, 1g, 1 oct/min Shock IEC 60068-2-27: 3 axis, 15g half sine, 11ms Enclosure Rating IP20 (IEC 529) Enclosure Material Aluminum (chassis) / zinc plated steel (cover) Mounting Snap-on with self-locking spring for 35mm DIN rails per EN 50022-35x15/75, or wall mount with bracket Connection Pluggable screw terminals (plugs included) General Specifications Safety Standards Specification Standard Document Number Safety Class Degree of electrical protection Class 1 IEC 536 Electromagnetic Compatibility (EMC), Emissions EMC, Emissions Corresponds to connected units ( no internal switching device) Electromagnetic Compatibility (EMC), Immunity EMC, Immunity Corresponds to connected units ( no internal switching device) Pollution Degree 2 n/a Un Note: All specifications are valid at nominal input voltage, full load and +25 C after warmup time, unless otherwise stated. Dimensions Unit: mm (inches) www.automationdirect.com 5