Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Similar documents
Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Redundancy unit CP-A RU

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Power supply CP-E 24/10.0 Primary switch mode power supply

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Messaging module CP-C MM

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Power supply CP-C 24/5.0

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Power supply CP-C 24/5.0

Thermistor motor protection relay CM-MSS.11

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Electronic timer CT-ARS.11

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.21

Electronic timer CT-ERD.12

Thermistor motor protection relay CM-MSS.31

Thermistor motor protection relay CM-MSS.41

Electronic timer CT-ERS.21

Electronic timer CT-AHD.22

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.41

Accessories for pluggable interface relays CR-P Sockets

Contact protection relay

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 07/2006

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

Three-phase monitoring relay

Accessories for pluggable interface relays CR-U Pluggable function modules

QUINT-BUFFER/24DC/24DC/40

Pluggable interface relays CR-P Pcb relays

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

STEP-PS/1AC/24DC/1.75

Output Voltage* (nom.)(adjustable)

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Rhino PSM Power Supplies. Operating Instructions

PHOENIX CONTACT - 01/2007

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Output Voltage* (nom.)(adjustable)

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

QUINT-PS-3x AC/24DC/10

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Pluggable interface relays CR-M Miniature relays

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

DC561, digital input/output module,

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS AC/24DC/10

AI561 Analog Input Module

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Industrial Power Supplies

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

DX561 Digital Input/Output Module

Power Supply HARTING pcon

Industrial Power Supplies

DC562, digital input/output module,

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

DI572 Digital Input Module

AO523 Analog Input Module

Industrial Power Supplies

ABB i-bus KNX HCC/S Heating/cooling circuit controller

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

Extract from the online catalog

ABB i-bus KNX BCI/S Boiler/Chiller Interface

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

TU531, TU532 Terminal Unit

DI561 Digital Input Module

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

AO561 Analog Output Module

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

BUFFER MODULE SHORT-FORM DATA MARKINGS

Power Supply HARTING pcon

Transcription:

Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range) The CP-B 24/20.0 serves to ensure a shortterm uninterrupted power supply system with a voltage of 24 V DC by buffering the load in case of power loss. The buffer module features a new technology of storing energy by using ultra-capacitors which entirely obviate the need for maintenance and exempt deep discharge in comparison to batteries. The energy storage can be expanded with additional extension modules for longer buffering times and is therefore utmost adaptable. 2CDC 271 003 S0010 Characteristics Buffer module for supporting the supply system in case of mains failure Rated input voltage 24 V DC Rated output voltage 24 V DC Rated input current 20 A Rated output current 20 A Typical charging time < 135 s at 100 % load current Typical buffering time > 15 s at 100 % load current 2 relay contacts, normally open, INPUT OK and BUFFER STATUS status signal 1 relay contact, change-over, status signal 4 LEDs for indication of operational states 1 control signal input for specifical switch off, SHUT-DOWN Expandable with up to 2 extension modules CP-B EXT.2 Maintenance free Temperature resistant No deep discharge Order data Buffer module Type Rated input voltage Input voltage range Rated output voltage Rated output current Order code CP-B 24/20.0 24 V DC 23.4-27.4 V DC 24 V DC 20 A 1SVR 427 060 R2000 Accessory Type Rated voltage Voltage range Order code CP-B EXT.2 24 V DC 0-26.4 V DC 1SVR 427 065 R0000

Functions Operating controls and terminals 1 Signalling SHUT-DOWN+, SHUT-DOWN-: Input signal terminals INPUT OK, BUFFER STATUS, : Signalling contact terminals 1 2 Input terminals IN, IN, IN : Input voltage terminals 2CDC 271 003 S0010 2 3 4 3 Indication of operational states OPERATION: Buffer module in operation (standby or buffering) INPUT OK: Input voltage applied BUFFER STATUS, : details see table LEDs, status information and fault messages on page 4 4 Output terminals OUT, OUT, OUT : Output voltage terminals EXT+, EXT-: Connection terminals for extension module Application In most areas of energy management and automation technology power supply systems have to be highly reliable. Often batteries are used for supporting the supply system in case of mains failures. Batteries have limited lifetimes depending on environmental parameters and, therefore, have to be maintained regularly, which causes efforts and costs. Using the latest ultra-capacitor technology, ABB offers an innovative and completely maintenance-free new product for buffering the 24 V DC supply at 20 A in case of interrupted mains on the primary side of the power supply. The CP-B 24/20.0 buffer module provides an ultra-capacitor buffered energy storage for power supply units. It ensures a short-term uninterrupted power supply system. In case of power loss, the energy stored in the capacitors guarantees that the load is continually provided, depending on the load current, up to several hundred seconds. Additional extensibility In order to ensure a longer uninterrupted power supply, the energy storage can be easily extended with up to 2 additional extension modules. Example of application L N CP-C 24/20.0 max. 20 A IN IN CP-B 24/20.0 EXT+ EXT+ EXT- EXT- CP-B EXT.2 OUT OUT max. 20 A buffered unbuffered load 1... load n load 1... load n 2CDC 273 010 F0210 2 - Buffer module CP-B 24/20.0, ultra-capacitor based Data sheet

Operating mode A power supply has to be connected to the buffer module s terminals IN and IN. Once the input voltage has been applied, the buffer module starts loading its ultra-capacitors. Having achieved an energy level greater than 80 % of the nominal capacitance, the LED BUFFER STATUS glows. Regardless of the energy level, the buffer module provides the according output voltage after having applied the minimum charging potential on the input side for about 2 s. In case of interrupted mains on the primary side of the power supply the buffer module guarantees that the load connected to terminals OUT and OUT is continually provided. In order to display the interrupted supply on the primary side the LED INPUT OK turns off while the capacitors are being discharged. When the energy level drops below 30 % of the nominal capacitance, the LED BUFFER STATUS turns off. The LED indicates faults due to overvoltage at the internal capacitors as well as overcurrent at the output. The messaging relays INPUT OK, BUFFER OK and are coupled with the correspondent LED which glows while the according relay is energized. Important operating features To trigger a safe shut-down of connected loads, a 24 V DC control signal can be applied to the terminals labelled SHUT-DOWN+ and SHUT-DOWN-. This effects that buffered loads can be switched off in a defined state. Furthermore the shut-down can be used if a specific energy level of the capacitors has to be conserved. Its advantage is that a subsequent charging of the capacitors can be shortened. For applications where higher currents are needed for a short time (e.g. energization of contactors), the buffer module is able to provide double of its rated output current for 1.5 s. To use this feature, completely charged capacitors are required. Decommissioning To put the buffer module out of operation, the power supply has to be turned off. Subsequently the buffer module continues to supply the load until the capacitors are discharged. In order to circumvent the subsequent buffering operation and the discharge of the capacitors, the module can be directly switched off by activating the shut-down without buffering. All LEDs turn off immediately. Functional interaction of power supply and buffer module in charging operation The buffer module s ultra-capacitors require a minimum charging potential, which has to be provided by the power supply. The minimum charging potential is necessary to charge the capacitors or to preserve the energy level in case of fully loaded capacitors. The charging process and the charging time of the buffer module depend on the input and the load current. Having buffered and unbuffered loads connected to the power supply result in a split up of its provided current into parallel divided circuits (see Example of application on page 2). In order to use the maximum available current provided by the power supply, the buffer module acts as a variable load. The module decreases its load, if the rated input current of the buffer module would cause the power supply to cut the output voltage down (load limiting function) or to perform a slow lowering of the output voltage, resulting in an input voltage lower than the specified minimum charging potential. In this way the buffer module ascertains the fastest possible charging process according to the power supply used. Note: It is highly recommended that loads which do not need an uninterrupted supply are connected directly, in parallel to all buffered loads, with the power supply. Buffering such loads would only reduce the buffering time which is load dependent. Therefore loads should be selected as small as necessary in order to achieve high buffering times. Years 60 50 40 30 Note: The capacitor s life span depends on the temperature exposed to as shown in the figure below as well as on the load current. The end of the life span is reached, when its capacitance drops below 70 % of its nominal capacitance. Using the buffer module continuously at its specified maximum applicable temperature, the expected product lifetime is approximately 5 years. 20 10 0 10 20 30 40 50 60 70 Temperature [ C] 2CDC 272 031 F0210 Capacitor s life span over temperature Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based - 3

SHUT-DOWN + Indication of operational states LEDs, status information and fault messages Operating state INPUT OK OPERATION LED green LED green Input voltage applied V V Device in operation (input voltage applied or internally supplied -- V by using energy stored in capacitors) Charging process (energy stored in capacitors > 30 and < 80 % ) V V BUFFER STATUS LED green LED red -- -- -- -- -- -- Energy stored in capacitors > 80 % (while charging) V V V -- Energy stored in capacitors < 30 % (while discharging) OFF V OFF V Capacitors discharged (load no longer supplied, only internal supply is maintained) Overvoltage at internal capacitors, overcurrent at output, overvoltage at input terminal OFF V -- V -- V -- V Capacitors discharged or shut-down activated OFF OFF OFF OFF -- = not relevant Installation The device must be installed by qualified persons only and in accordance with the specific national regulations (e.g. VDE, etc.). The CP-B 24/20.0 is a chassis-mounted unit. It is maintance-free and does not contain any integral setting elements and should therefore not be opened. If the buffer module is built into systems needing overvoltages for testing (e.g. EN 60204-1/ VDE0113 part1 19.4 voltage control), the module must be disconnected during the test. (Original text EN 60204-1: components, which are not dimensioned for the testing voltage must be separated during the testing.) Note: The device is completely maintenance free. The enclosure is sealed. DANGER! Components with high stored energy Danger to be electrocuted! Disconnect the system from the supply network and protect against switching on before any installation, maintenance or modification work. Discharge the buffer module completely. Do not introduce any objects into the unit and do not open the unit. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. Mounting position (B) 83.7 3.3" The device has to be mounted horizontally with the input terminals on the bottom. In order to ensure a sufficient convection, the minimum distance to the other modules must be not less than 80 mm (3.15 in) in vertical direction. Minimum distance in horizontal direction is not necessary. (A) (A) CP-B 24/20.0 SHUT-DOWN - INPUT OK BUFFER STATUS OPERATION INPUT OK BUFFER STATUS IN L - IN L - IN 192.5 7.58" OUT L - OUT L - OUT (B) EXT+ EXT- 187.8 7.4" 2CDC 272 026 F0010 4 - Buffer module CP-B 24/20.0, ultra-capacitor based Data sheet

Electrical connection The installation must be executed according to EN 60950 and possible applicable local standards. The input side is protected by an internal input fuse. IN IN IN Input voltage SHUT DOWN+ IN EXT+ EXT- OUT INPUT OK BUFFER STATUS SHUT DOWN- SHUT-DOWN+ SHUT-DOWN- INPUT OK INPUT OK BUFFER STATUS BUFFER STATUS IN IN IN OUT OUT OUT EXT+ EXT- 2CDC 272 022 F0010 OUT OUT OUT Output voltage INPUT OK Signalling contact (relay) BUFFER STATUS Signalling contact (relay) Signalling contact (relay) SHUT-DOWN Input control signal EXT+, EXT- Connection of the extension module CP-B EXT.2 Connection diagram 1. Connect the load to be buffered to the output terminals OUT and OUT. 2. Additional extension modules (CP-B EXT.2) are connected to the terminals EXT+ and EXT-. 3. The signalling contact INPUT OK can be used for external status analysis. In case of overload, the output current comprises the maximum current of the buffer module as well as the current of the power supply unit. The overload protection has to be realized externally. Rate the lines for the maximum output current or provide separate fuse protection. It is recommended to choose the wire size as large as possible in order to minimize voltage drops. Observe the polarity. The device is overload and open-circuit proof. Operation DANGER! High current Risk of electric arcs and electric shocks! Do not modify the installation (primary and secondary side). Intended use. CAUTION! Enclosure can become very hot depending on the operation conditions Risk of burns! In order to ensure sufficient air-cooling the distance to other devices has to be considered. Before start of operation the following must be ensured: 1. Connect electrical lines according to the specific national regulations for class of protection III. 2. Power supply cables and unit must be sufficiently fused. 3. A disconnection device has to be provided for the power supply to disengage unit and supply cables from supply mains if required. 4. Rate the output lines for the output current of the buffer module and connect them with the correct polarity. If the buffer module is entirely charged and works in the standby mode, there is no heating of the module. From the thermal point of view this can be compared with a switched-off device. The device is intended for use as a buffer module. Any other usage is not supported by the manufacturer. Other usage, improper installation or operation may impair safety and cause operational difficulties or destruction of the unit. Service The internal fuse is not user-replaceable. If the internal fuse blows, most probably the device is defective. In this case, an examination of the buffer module by the manufacturer is necessary. Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based - 5

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Supply circuit IN IN Rated input voltage U in 24 V DC Input voltage range 23.4-29 V DC Minimum charging potential 23.4 V DC Rated input current 20 A DC Inrush current limiting 35 A / 2 ms Transient overvoltage protection varistor / suppressor diode Internal input fuse (apparatus protection, not accessible) 30 A (FK2) Internal fuse capacitors circuit (not accessible) 30 A (FK2) Kind of input SHUT-DOWN control input rated voltage 24 V DC voltage range 6-45 V DC Indication of operational states Input voltage INPUT OK LED green Internal system voltage OPERATION LED green Energy storage level BUFFER STATUS LED green Fault status LED red details see table LEDs, status information and fault messages on page 4 Output circuits OUT OUT OUT Rated output power 480 W Rated output voltage U out 24 V DC Output voltage (buffer mode) 23.2 V DC Tolerance of the output voltage +2...-10 % Rated output current I r T a 60 C 20 A DC Peak output current (fully loaded capacitors required) T a 60 C 40 A DC (min. 1.5 s) Short-circuit protection (via internal 30 A fuse and external 25 A fuse) no continuous short-circuit stability Internal output fuse (not accessible) 30 A (FK2) Required external fuse 25 A slow acting Power failure buffering time load-dependent, min. 15 s at 100 % load Overload protection thermal protection Kind of output INPUT OK n/o contact BUFFER STATUS n/o contact c/o contact Contact material Ag + Au-clad Minimum switching voltage / Minimum switching current 5 V DC / 1 ma Maximum switching voltage / Maximum switching current 50 V AC / 1 A, 30 V DC / 0.5 A Mechanical lifetime 5 x 10 6 switching cycles Electrical lifetime 0.1 x 10 6 switching cycles Maximum fuse rating to achieve short-circuit protection n/o or n/c contact 1.0 A AC / 0.5 A DC 6 - Buffer module CP-B 24/20.0, ultra-capacitor based Data sheet

General data MTBF available on request Maximum internal power consumption 40 W Power consumption with unloaded output 1.6 W Energy storage (min.) 8000 Ws Typical charging time at load current 100 % 135 s 0 % 62 s Typical buffering time at load current 1) 100 % 15 s 50 % 30 s 25 % 60 s 10 % 150 s Efficiency greater than 90 % Duty time 100 % Dimensions see "Dimensional drawings" Weight net 2.2 kg (4.85 lb) Material of enclosure cover steel sheet powdered enclosure shell steel sheet powdered Mounting DIN rail (IEC/EN 60715), snap-on mounting Mounting position horizontal Minimum distance to other units horizontal not necessary vertical 80 mm (3.15 in) Pollution degree 2 Degree of protection enclosure IP20 terminal IP20 Protection class (IEC/EN 61140) III SELV / PELV (condition: power supply fulfills class III) 1) buffering time energy storage x 0.9 load current x 23.2 V Electrical connection (pluggable screw type terminals) Input circuit, output circuit Connecting capacity fine-strand with wire end ferrule with(out) plastic sleeve 0.25-4.0 mm² fine-strand without wire end ferrule 0.2-4.0 mm² rigid 0.2-4.0 mm² AWG 24-10 Stripping length 7.0 mm (0.28 in) Tightening torque max. 0.6 Nm (5.31 lb.in) Recommended screw driver Ø 3.5 mm (0.14 in) Signalling circuit Connecting capacity fine-strand with wire end ferrule without plastic sleeve 0.25-1.5 mm² fine-strand with wire end ferrule with plastic sleeve 0.25-0.5 mm² fine-strand without wire end ferrule 0.14-1.5 mm² rigid 0.14-1.5 mm² AWG 28-16 Stripping length 7.0 mm (0.28 in) Tightening torque max. 0.25 Nm (2.21 lb.in) Recommended screw driver Ø 2.5 mm (0.10 in) Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based - 7

Environmental data Ambient temperature operation -40...+60 C (-40...+140 F) storage -40...+60 C (-40...+140 F) Vibration, sinusoidal based on IEC/EN 60068-2-6 1.6 mm, 2-17.62 Hz; 2 g, 17.62-500 Hz, 20 cycles Shock, half-sine based on IEC/EN 60068-2-27 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face Standards / Directives Standards EN 50178, IEC/EN 60950 1, IEC/EN 62040-2 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kv / 8 kv radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz) electrical fast transient / burst IEC/EN 61000-4-4 Level 3, 2(1) kv / 5 khz surge IEC/EN 61000-4-5 Level 1, 0.5 kv conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3, 10 V (150 khz-80 MHz) voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 buffered by ultra-capacitors Interference emission EN 61000-6-4 high-frequency radiated DIN EN 55011 B/C1 high-frequency conducted DIN EN 55011 B/C1 Technical diagrams Temperature behavior I out [A] 20 Normal application (up to 50 % buffer mode, 5 charging and discharging cycles in direct series) 15 10-40 -20 0 20 40 60 Continuous charging and discharging in direct series. As this is not typical of a real application, this should be considered as theoretical indication T a [ C] 2CDC 272 030 F0210 Characteristic curve of the temperature at rated load 8 - Buffer module CP-B 24/20.0, ultra-capacitor based Data sheet

Dimensions in mm and inches IEC/EN 60715 TH 35-7.5 TH 35-15 192.5 7.58" 198.0 7.80" 187.8 7.4" 195.3 7.7" 215.8 8.5" 83.7 3.3" 2CDC 272 009 F0017 CP-B 24/20.0 (pluggable screw type terminals included in delivery) IEC/EN 60715 TH 35-7.5 TH 35-15 92.5 3.64" 99.8 3.93" 112.4 4.43" 121.2 4.77" 126.2 4.97" 60.0 2.36" 2CDC 272 010 F0017 Accessory CP-B EXT.2 Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based - 9

Further documentation Document title Document type Document number Electronic relays and controls Catalog 2CDC 110 004 C02xx CP-B 24/20.0 Instruction sheet 1SVC 427 062 M0000 CP-B EXT.2 Data sheet 2CDC 114 080 D0201 CP-B EXT.2 Instruction sheet 1SVC 427 063 M0000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Power supplies. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Power Supplies. 10 - Buffer module CP-B 24/20.0, ultra-capacitor based Data sheet

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 114 081 D0201 Rev. H (09.06.2017) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved