Q.uick Start Guide: How to Configure the Q.station Data Logger

Similar documents
Q.uick Start Guide: How to configure the test.con Data Logger in a Q.gate-IPT or Q.pac-ECT

2015 Gantner Instruments Inc.

Q.brixx station 101. Base Unit with Test Controller. Most important features:

Q.brixx station 101. Base Unit with Test Controller. Most important features:

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

2015 Gantner Instruments Inc.

Q Series - Q.station 101 Test Controller

2015 Gantner Instruments Inc.

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

e.series IMPROVING RENEWABLE ENERGY TECHNOLOGY Intelligent Solutions for Wind Turbine Performance Measurement

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

Data sheet CPU 115 (115-6BL02)

e.reader Vers.-Nr. 01

Application Note For FTP in FlexiPanels and FlexiLogics Series HMI/PLCs

Web-enabled DAQ System

DRIVER STATION v1.0 UTILITY LOADER Created: 22DEC2008 FIRST DRIVER STATION UTILITY LOADER RE-IMAGE INSTRUCTIONS

BLUE LOG XM / XC. Quick Start Guide. Version

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

User Guide. BrightAuthor Release 2.0. BrightSign HD110, HD210, HD210w, HD410, HD810, HD1010, and HD1010w. COMPATIBLE WITH

Data sheet CPU 315SB/DPM (315-2AG12)

Stand Alone 512 channels DIN-DMX Interface

Data sheet CPU 315SB/DPM (315-2AG12)

HD Ovi Digital Clock WiFi Hidden Camera. User s Guide WHEN YOU NEED TO KNOW.

Using ECOpartner results in cost saving, energy savings, energy-use awareness, enhanced patterns of energy use, and conservation.

CMX18 FEATURES A 18-SLOT 3U PXI EXPRESS CHASSIS

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet VIPA CPU 115DP (115-6BL22)

ALMEMO Measuring Instruments

Intech Micro 2400-A16-SD

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted

Docking Station DS-U4WEB with web server version 1 Instruction Manual

AirWay Wireless Signal Transceiver

BLUE LOG X-SERIES. Quick Start Guide. Version

CP ADVANCED. Function

Introduction to Electronics Workbench

Stand Alone SLIM-DMX Interface

Data sheet VIPA CPU 214PG (214-2BE03)

Using the Synergy Controller s FTP Server

Data sheet CPU 315SN/NET (315-4NE12)

Specification for temperature sensor calibration setup

Data sheet CPU 315SN/NET (315-4NE12)

Computer Architecture CS 355 Busses & I/O System

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

Data sheet VIPA CPU 214NET PG (214-2BT13)

Lecture 7: Ethernet Hardware Addressing and Frame Format. Dr. Mohammed Hawa. Electrical Engineering Department, University of Jordan.

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

CONTROL SYSTEMS. MultiBasic Blue MultiBasic MultiClassic MultiPro. Overview. Execution TA. Execution FL. Type

Q.series Intelligent Solutions for Measurement and Test Automation

Verizon One Talk DECT IP Phone

Orifice Flow Meter

xlogic! CPU Built-in Ethernet

1900AC. Digital TV box. User Manual.

Docking Stations DS-U1, DS-U2, DS-U4, DS-U4-WL and DS-U Adjustment and configuration procedure for the analog inputs

Section 1 Establishing an Instrument Connection

testo easyheat Configuration and Analysis software Instruction manual

MS6174 Data Adaptor (USB type) Software Manual

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

SENSA DMX CONTROLLER KIT SAP code Pre-wired DMX Controller kit for DIN rail mounting

PanelView Plus 6 Terminals to 1500

icex-cmtm General specs and Installation guide

1:15 Standalone USB Duplicator and Eraser - for USB Flash Drives

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

PQM4000 and PQM4000 PQM4000RGW. Class A DIN 192x144 power quality analyzer for CTs. Class A certified in compliance with IEC/EN :2015 Ed.

Table of Contents Surveillance Center Overview...3 Log...30 Live Camera Panel...31 Live Camera Panel Explained I...32

ECE 341 Final Exam Solution

Official Publication Date: 12/18/2018 Official Expiration Date: Until Next Release

DataLab PC. Industrial PC-compatible computer. (models DataLab PC 1200, DataLab PC 1000, DataLab PC 800, DataLab PC 610, DataLab PC 600)

Using the Synergy Controller s FTP Server

STANDALONE INTERFACE USB-DMX DIN V 1.6.1

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

SignApps Express User Manual

eth1000_large.jpg Using ICC ETH-1000 EtherNet/IP Interface with Mitsubishi iq PLC

DIN-RAIL EXPANDER int-iors_en 10/14

Switched LANs A Set of Local Area Networks Interconnected by Switches

LP32. Package Content: Small package + 1 USB cable + 1 USB to DMX Interface (3 Pin XLR)

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Expanding the Basic GL7000 Configuration

AN6DMX V1.0 User manual Components on board: Electrical: Features of firmware: Mechanical: FACE SIDE

[LGZ USB USER MANUAL]

Conettix ITS-D6686-INTL

TENVIS Technology Co., Ltd. User Manual. For H.264 Cameras. Version 1.0.0

Trend II CPAP and APAP. Quick Setup Guide

Token Ring and. Fiber Distributed Data Interface (FDDI) Networks: Token Ring and FDDI 1

Drulo Control Operating Instructions. Version and higher

Weilekes Elektronik GmbH Am Luftschacht Gelsenkirchen Germany Tel: Fax:

DATA ACQUISITION Hints and Tips

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

XIV. XV. XVI. XVII. Manufacturer reserves the right to change the contents of this manual without notice.

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

Data logger systems from ROTRONIC

DATA LOGGER MODELS DL-1080/1081

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

testo Comfort Software Basic 5 Instruction manual

Accelerometer Mouse: Hardware Description

Level monitoring system NT 2000 / 3500 series Selection list

THE WORLD OF WEATHER DATA

Get Connected with USB on RX62N RX62N USB

MINIMAT-EC-Servo Screwdriver Spindles

Transcription:

Q.uick Start Guide: How to Configure the Q.station Data Logger Purpose: This document is used to provide a thorough understanding of how to configure and utilize the logging capabilities of a Q.station (DIN rail mount or Q.brixx version). Items Required: - Q.station with adequate power supply (Q.brixx-station is supplied with an AC to DC power adapter) - PC with a licensed version of test.commander installed - Ethernet cable Procedure: 1. Assemble hardware together (Q.station + measurement modules). 2. Power on hardware and connect Ethernet cable between PC and Q.station. 3. Start test.commander. Create a new project. 4. In the empty project, right-click on the mouse and select Add Online Controllers. 5. All controllers on the same network will be displayed, highlight the controller to connect to and click OK.

6. When the controller is successfully added to the project, the following window will appear: 7. The Q.station and attached measurement modules will be displayed in the project work space: 8. Configure the channels (type, scaling, etc): real and virtual channels. 9. Adjust the number of desired buffers/sample rates: Double-click on the Q.station, Sample Rate > Count. By default, there is 1 x buffer used (maximum: 4). 10. Modify each buffer: - Customize the name of each buffer. - Modify the sample frequency (buffer #1 must have the highest sample frequency). - Modify the buffer size (the combined buffer size for all buffers can be a max of 200 MB). - Buffers 2-4 can be synchronized internally (use internal clock) or external (digital input on Q.station). - Click OK to apply settings.

11. In the main project space, assign which channels (real and virtual) belong to a certain buffer. You should only use one buffer rate per UART (it is always possible to have multiple logging rates use a single buffer). This is performed using the Sample Rate column: 12. Highlight the Q.station and click on the Logger Configuration button.

13. The Logger Configuration window will appear. 14. It is possible to add or delete a logger: A maximum of 20 x loggers can be created in a single Q.station. 15. For each logger, select the data source, logger type, logger name, and logger status: - Data Source: select the buffer in which the channels to save are located. Select one of the configured buffers. - Logger Type: select between continuous, triggered, or event-based. - Logger Name: provide a name for each logger. The data files will include this name in the file. - Logger Status: activated or deactivated. 16. Select the channels to save within the logger. Only channels within the selected buffer can be saved within that logger. 17. Other arithmetic channels can be added to any of the available variables. Right-click on the variable and select the type of arithmetic channel to add. - Empty arithmetic - Statistical data - Minimum, maximum, average, and standard deviation

18. Double-click on the new virtual variable to modify its equation. 19. The logger type will determine the available triggering options. 20. Logger Type: Continuous. With this type it is possible to select the logging rate of the logger and the size of a single file.

The logging rate can be set in seconds or Hz: The size of a single file can be set in seconds, data sets, or bytes: 21. Logger Type: Triggered. With this type it is possible to select the logging rate. It is also possible to assign start and stop trigger conditions; the channel(s) must be selected from within the same buffer. Pre and/or post trigger data can also be added.

The logging rate can be set in seconds or Hz. The size of a single file can be set in seconds, data sets, or bytes; additionally the pre and/or post trigger data can be set in either seconds or data sets. 22. The possible condition arguments: - < : less than - <= : less than or equal to - > : greater than - >= : greater than or equal to - == : equal -!= : not equal 23. Logger Type: Event-based. With this logging type it is possible to start logging based on an event. A pre-trigger is optional, while the event length can be specified in seconds, data sets, and bytes. The size of a single file is specified by number of events.

24. For all 3 x logger types, the storage type can be chosen: Default: automatic drive slection. For more information regarding the other options, see section 7.4.2 in the Q.station manual. This option determines how and in what sequence writing occurs to the destinations. 25. The destination for each logger can be chosen next. Either internal memory of the Q.station, SD card, or USB port. 26. It is possible to also send data to the following destinations: a network drive, FTP server, or via E-mail. How to configure these destinations are explained in separate guides that can be found on the Gantner Instruments website: www.gantnerinstruments.com/library.html

27. Make sure to save the settings in the Logger Configuration window by clicking the OK button. 28. Since a lot of changes have been made to the project settings and logging settings, these need to be updated to the controller. Notice a red star appears next to the Q.station. Click on the Write Project (Update) button to perform the update. 29. After the update is performed the Q.station starts logging immediately (if continuous is selected) or waits for the trigger conditions to occur. Files in the storage destination (i.e. USB drive, SD card, etc.) are saved as.dat files and can be opened using test.viewer. 30. Multiple data files can be appended together using test.viewer: File > Append File 31. Single or appended files can be saved into other formats: File > Save As