Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Similar documents
Pressure switch Type KP

Pressure switch KP. Data sheet

for for Industrial Refrigeration

Pressure controls, Type KP

Pressure switches and thermostats, types KP and KPI

Pressure switch, Differential pressure switch RT

Pressure switch, Differential pressure switch RT

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet

INSTRUCTIONS. KP R9748 KP 61, 62, 63, 68, 69 vapor charge KP 71, 73, 75, 77, 79, 81 adsorption charge (cross ambient)

CI-tronic Reversing contactor Type RCI

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Circuit Breakers Type CTI 25M, CTI 45MB

Switching relay CT-IRE with 1 c/o (SPDT) contact

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V

ZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Disconnect Switches. Safe Switching and Disconnecting

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Classification Enclosure rating Input voltage Type of

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

Motor protection relays

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection

Zelio Control-modular measurement and control relays 1

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

TeSys contactors From 115 to 2750 A

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XB4BW73731B5 green flush/red projecting illuminated doubleheaded pushbutton Ø22 1NO+1NC 24V

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Room Temperature Controller

RTU500 series Data Sheet Power Supply CP-E 24/2.5

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

Micro Contactor MA Series

QUINT-PS/ 1AC/24DC/20/CO

XB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Three-phase monitoring relay

Electronic timer CT-ERD.12

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

93 SERIES. Timed socket for 34 series 93.68/93.69

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

Thermistor motor protection relay CM-MSS.21

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Miniature Circuit Breakers for Railway Applications

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

TeSys IEC Contactors and Overload Relays

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

PRODUCT SPECIFICATION. PC Board Relays. Series.

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

K1B004TLH cam switch - 1 pole A - screw mounting

Non-communicating room controllers

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

XB4BL Main. Device short name. Fixing collar material. Shape of signaling unit head. Contacts type and composition

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Model Number Structure

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

ZB5FG09 flush mounted selector switch head key pos stay put

Series A19A/A19B/A19D. Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Electronic timer CT-ARS.11

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Ultra Slim Relays 24

PHOENIX CONTACT Features

OsiSwitch Limit Switches Innovation through modularity

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Transcription:

Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or installed in the control circuit of DC motors and large AC motors. The KP Thermostats are used for regulation, but can also be seen in safety monitoring systems. They are available with vapour charge or with adsorption charge. With vapour charge the differential is very small. The KP Thermostats with adsorption charge are widely used to give frost protection. Features Wide regulating range Can be used for deep freeze, refrigeration and air conditioning plant Welded bellows elements mean increased reliability Small dimensions. Easy to install in refrigerated counters or cold rooms Ultra-short bounce times. This gives long operating life, reduces wear to a minimum and increases reliability Standard versions with changeover switch. Possible to obtain opposite contact function or to connect a signal Electrical connection at the front of the unit. Facilitates rack mounting Saves space Suitable for alternating and direct current Cable entry of soft thermoplastic for cables from 6 to 14 mm diameter Extensive and wide range Approvals CE-marked in accordance with EN 60947-4/-5 for sale in Europe China Compulsory Certificate, CCC Underwriters Laboratories Inc., US UL GOST Ship approvals Germanischer Lloyd, GL (excluding KP 98) Registro Italiano Navale, RINA Bureau Veritas, France, BV (excluding KP 98) Lloyd s Register, LR (excluding KP 79, KP 81, KP 98) Russian Maritime Register of Shipping, RMRS Note: Marine Approvals do not cover KP 98 dual thermostat. DKRCC.PD.CA0.C7.02 520H11317 1

Technical data Ambient temperature Switch -40 65 C (80 C for max. 2 hours). Single-pole, double-throw (SPDT) changeover switch. Contact load Alternating current Direct current AC1 =16 A, 400 V AC3 = 16 A, 400 V DC13: 12 W, 220 V control current solid / stranded 0.75 2.5 mm 2 Wire dimensions flexible, without ferrules 0.7 2.5 mm 2 flexible, with ferrules 0.5 1.5 mm 2 Tightening torque Rated impulse voltage max. 2 Nm 4 kv Pollution degree 3 Short circuit protection, fuse Insulation 16 A 400 V Enclosure 30/44 Cable connection Cable entry for cables 6 14 mm dia. A Pg 13.5 screwed cable entry can be used for 6 14 mm dia. cables. With 8 16 mm cables a standard Pg 16 screwed cable entry can be used. Enclosure IP30 to EN 60529 / IEC 529 This grade of enclosure is obtained when the unit is mounted on a flat surface or bracket. The bracket must be fixed so that all unused holes are covered. Contact systems KP temperature control KP 98 DKRCC.PD.CA0.C7.02 520H11317 2

Regulating range KP 61 KP 62 Vapour range KP 63 KP 68 KP 69 KP 62 Adsorption charge KP 71 KP 73 KP 75 KP 77 KP 79 KP 81 KP 98 OIL KP 98 OIL KP 98 HT KP 98 HT -50 0 50 100 150 200 C DKRCC.PD.CA0.C7.02 520H11317 3

Ordering Charge Type Bulb type Setting - range Differential t Reset Max. bulb temp. Lowest temperature Highest temperature Capillarytube length Code no. [ C] [ C] [ C] [ C] [m] Vapour 1 ) Adsorbtion 2 ) KP 61 A -30 15 5.5 23 1.5 7 aut. 120 2 060L110066 KP 61 A -30 15 5.5 23 1.5 7 aut. 120 5 060L110166 KP 61 B -30 13 4.5 23 1.2 7 aut. 120 2 060L110266 KP 61 B -30 15 5.5 23 1.5 7 aut. 120 2 060L110366 3 ) KP 61 B -30 15 5.5 23 1.5 7 aut. 120 2 060L112866 3 ) 4 ) KP 61 A -30 15 Fixed 6 Fixed 2 min. 120 5 060L110466 KP 61 B -30 15 Fixed 6 Fixed 2 min. 120 2 060L110566 KP 62 C 1-30 15 6.0 23 1.5 7 aut. 120 060L110666 KP 63 A -50 10 10.0 70 2.7 8 aut. 120 2 060L110766 KP 63 B -50 10 10.0 70 2.7 8 aut. 120 2 060L110866 KP 68 C 1-5 35 4.5 25 1.8 7 aut. 120 060L111166 KP 69 B -5 35 4.5 25 1.8 7 aut. 120 2 060L111266 KP 62 C 2-30 15 5.0 20 2.0 8 aut. 80 060L111066 3 ) 4 ) KP 71 E 2-5 20 3.0 10 2.2 9 aut. 80 2 060L111366 KP 71 E 2-5 20 Fixed 3 Fixed 3 min. 80 2 060L111566 KP 73 E 1-25 15 12.0 70 8.0 25 aut. 80 2 060L111766 KP 73 D 1-25 15 4.0 10 3.5 9 aut. 80 2 060L111866 3 ) KP 73 D 1-25 15 Fixed 3.5 Fixed 3.5 min. 80 2 060L113866 KP 73 D 2-20 15 4.0 15 2.0 13 aut. 55 3 060L114066 KP 73 D 1-25 15 3.5 20 3.25 18 aut. 80 2 060L114366 KP 75 F 0 35 3.5 16 2.5 12 aut. 110 2 060L112066 KP 75 E 2 0 35 3.5 16 2.5 12 aut. 110 2 060L113766 KP 77 E 3 20 60 3.5 10 3.5 10 aut. 130 2 060L112166 KP 77 E 3 20 60 3.5 10 3.5 10 aut. 130 3 060L112266 KP 77 E 2 20 60 3.5 10 3.5 10 aut. 130 5 060L116866 KP 79 E 3 50 100 5.0 15 5.0 15 aut. 150 2 060L112666 KP 81 E 3 80 150 7.0 20 7.0 20 aut. 200 2 060L112566 KP 81 E 3 80 150 Fixed 8 Fixed 8 max. 200 2 060L115566 KP 98 E 2 OIL: 60 120 OIL: Fixed 14 OIL: Fixed 14 max. 150 1 E 2 HT: 100 180 HT: Fixed 25 HT: Fixed 25 max. 250 2 060L113166 1 ) Bulb must always be placed colder than the thermostat housing and capillary tube. The thermostat will then regulate independent of ambient temperature. 2 ) Bulb can be placed warmer or colder than thermostat housing and capillary tube, but variations from 20 C ambient temperature will influence the scale accuracy. 3 ) With manual switch, not isolating switch. 4 ) Panel mounting model with top plate. DKRCC.PD.CA0.C7.02 520H11317 4

Ordering (continued) Thermostat bulb types A Straight capillary tube B ø9.5 70 mm remote air coil C C1: ø40 30 mm air coil C2: ø25 67 mm air coil (integral with thermostat) D D1: ø10 85 mm double contact remote bulb D2: ø16 170 mm double contact remote bulb Note! Cannot be used in sensor (bulb) pocket E E1: ø6.4 95 mm remote bulb E2: ø9.5 115 mm remote bulb E3: ø9.5 85 mm remote bulb F ø25 125 mm remote duct coil DKRCC.PD.CA0.C7.02 520H11317 5

Design Function Key sketch of KP thermostat KP thermostat 1 2 16 60-1032.10 3 7 8 4 1 2 60-296.16 1. Temperature setting spindle 2. Differential setting spindle 3. Main arm 7. Main spring 8. Differential spring 9. Bellows 12. Switch 13. Terminals 14. Earth terminal 15. Cable entry 16. Tumbler 17. Sensor 9 15 17 12 60-1033.10 17 60-904.12 17 60-272.12 Adsorption charge Vapour charge Adsorption charge Vapour charge The switch in the KP has a snap-action function and the bellows move only when the cut-in or cut-out value is reached. The design of the KP thermostats affords the following advantages: y high contact load, y ultra-short bounce time, y vibration resistance up to 4 g, in the range 0 1000 Hz, y long mechanical and electrical life. DKRCC.PD.CA0.C7.02 520H11317 6

Design Function (continued) KP thermostat, dual type 60-370.16 1. Temperature setting spindle, OIL 3. Main arm 5. Temperature setting spindle, HT 7. Main spring 9. Bellows 10. Capillary tube, OIL 11. Capillary tube, HT 12. Switch 13. Terminals 14. Earth terminal 15. Cable entry 16. Tumbler 17. Sensor (bulb) 18. Locking plate 60-421.13 Dual thermostat KP 98 is used to provide protection against excessively high discharge gas temperature and to ensure a suitable oil temperature in the compressor. To avoid the temperature of the hot gas exceeding the maximum permissible value during extreme operating conditions (low evaporating pressure, high condensing pressure, high suction vapour superheat) a KP 98 thermostat can be used on the high temperature side (HT). If the temperature of the hot gas becomes too high the refrigerant will break down and the compressor discharge valve will become damaged. The risk is greatest in refrigeration systems that operate on a high compression ratio (e.g. in systems with NH 3 or R22) and in applications with hot gas bypass. This unit has two separate thermostat functions. The HT sensor that controls the discharge gas temperature is fitted on the discharge tube immediately after the compressor. For larger compressors, the sensor can be built into the discharge line. The OIL sensor that controls the oil temperature is located in the compressor oil sump. Terminology Differential The differential is the difference between the make and break temperatures. A differential is necessary for satisfactory automatic operation of the plant. Mechanical differential (intrinsic differential) The mechanical differential is the differential set by the differential spindle. Operating differential (thermal differential) The operating differential is the differential the plant operates on. Operating differential is the sum of the mechanical differential and the differential produced by the time constant. Reset 1. Manual reset: Units with manual reset can only be restarted after the reset button has been activated. On min. reset units the set value is equal to the cut-out value for falling temperature. On max. reset units the set value is equal to the cut-out value for rising temperature. 2. Automatic reset: These units are automatically reset after operational stop. DKRCC.PD.CA0.C7.02 520H11317 7

Setting Thermostats with automatic reset Set the upper activating temperature on the range scale. Set the differential on the "DIFF" scale. The temperature setting on the range scale will then correspond to the temperature at which the refrigeration compressor will be started on rising temperature. The compressor will be stopped when the temperature has fallen in relation to the differential setting. Note that the differential depends on the range setting. Therefore, the differential scale must only be used as guideline. If with low stop temperature settings the compressor will not stop, check whether the differential is set at too high a value! Thermostats with minimum reset Set the stop temperature on the range scale. The differential is a fixed setting. The compressor can be restarted by pressing the Reset button after the temperature on the thermostat sensor has risen by a value equal to the fixed differential setting. Thermostats with maximum reset Set the stop temperature on the range scale. The differential is a fixed setting. The compressor can be restarted by pressing the Reset button after the temperature on the thermostat sensor has fallen to a value equal to the fixed differential setting. Charges 9. Bellows element 17. Sensor (bulb) 19. Capillary tube 1. Vapour charge Here the interdependence between the pressure and temperature of saturated vapour is utilized, i.e. the element is charged with saturated vapour plus a small amount of liquid. The charge is pressure-limited; a further increase in pressure after evaporation of all the liquid in the sensor (17) will only result in a small pressure increase in the element. This principle can be utilized in thermostats for low temperature, etc. where evaporation must be able to take place from the free liquid surface in the sensor (within the operating range of the thermostat), and where at the same time, the bellows must be protected against deformation when kept at normal ambient temperatures. Since the pressure in the element depends on the temperature at the free liquid surface, the thermostat must always be placed so that the sensor is colder than the rest of the thermostatic element. The evaporated liquid will recondense at the coldest point, i.e. the sensor. Thus, as intended, the sensor becomes the temperature-controlling part of the system. Note: When the sensor is coldest, the ambient temperature has no effect on regulating accuracy. 9. Bellows element 17. Sensor (bulb) 19. Capillary tube 2. Adsorption charge In this case the charge consists partly of a superheated gas and partly of a solid having a large adsorption surface. The solid is concentrated in the sensor (17) and it is therefore always the sensor that is the temperature-controlling part of the thermostatic element. The sensor can be placed warmer or colder than thermostat housing and capillary tube, but variations from 20 C ambient temperature will influence the scale accuracy. DKRCC.PD.CA0.C7.02 520H11317 8

Dimensions [mm] and weights [kg] 60-985.12 KP 61 81 Mounting holes (back of KP) 60-986.12 KP 98 Mounting holes (back of KP) Wall bracket Angle bracket D2: E2: E3: KP 73 KP 71 KP 77, KP 73 KP 75, KP 77, KP 98 D1: E1: F: KP 73 KP 73 KP 75 KP 79 KP 81 A: B: C1: KP 61, KP 61, KP 62, KP 63 KP 63, KP 68 KP 69 C2: KP 62 Net weight: KP 61 81: approx. 0.4 kg KP 98: approx. 0.6 kg DKRCC.PD.CA0.C7.02 520H11317 9

can accept no responsibility for possible errors in catalogues, brochures and other printed material. reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. and the logotype are trademarks of A/S. All rights reserved. DKRCC.PD.CA0.C7.02 520H11317 10