Time Counters mini "h", DC Version

Similar documents
Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Incremental Encoder with Hollow Shaft

Process displays For current and voltage

Faults on the system Proximity switch connection technology:

Pulse counters, electromechanical

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Analog Voltage Combination Module

Encoders without bearings - incremental Magnetic sensing, through hollow shaft max. ø180 mm pulses or 128 sinewave cycles per turn

Output Voltage* (nom.)(adjustable)

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

Kuhnke Technical Data. Contact Details

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Output Voltage* (nom.)(adjustable)

02/11/2015

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Kuhnke Technical Data. Contact Details

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

E-STOP relays, safety gate monitors

AI561 Analog Input Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

masterelectronics.com onlinecomponents.com

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Micro Contactor MA Series

General information. Display. Supply voltage. Input current. Encoder supply. Output current

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data

PRODUCT SPECIFICATION. PC Board Relays. Series.

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

20 General technical data XI/ON

General information. Display. Supply voltage

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

signo 727 SSI operating instructions

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

DI561 Digital Input Module

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

Temperature Controller E5C4

iologik 4000 Series (M) Modules

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Slim Industrial Relay Type RSLM Electromechanical

Screw terminal panels, Relay output boards, connection cables

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

EM2020 Selectable AC transducer A (UK)

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

SITOP in the SIMATIC Design

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

SRT2-ROC08, SRT2-ROC16

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

E-STOP relays, safety gate monitors

General information. Display. Supply voltage

02/11/2015

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

E-STOP relays, safety gate monitors

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

H2C Motor Timers will be Discontinued March 2013; Replace with H3CR-A8E Solid-state Timer

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

SUBJECT TO CHANGE WITHOUT NOTICE

Expansion Module HZS 541-1S

E-STOP relay, safety gate monitor

Relays & Sockets RR Series Power Relays. Part Number Selection

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

JUMO mtron T Measuring, Control, and Automation System

Inductive Proximity Sensor

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

08/07/2015

DC562, digital input/output module,

DI572 Digital Input Module

Amplifiers, Counters, Timers & Controls

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

E-STOP relay, safety gate monitor

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

E-STOP relays, safety gate monitors

MHAP HDmag. Features

E-STOP relays, safety gate monitors

Transcription:

Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable and washable versions available Protection class IP 65 7-digit, 0... 99 999.99 h Supply voltage Vop acc. to order information, tolerance + 10 % Power consumption approx. 30 mw Residual ripple < 1 % Operating temperature - 10... + 60 C Storage temperature - 40... + 70 C El. connection versions.0 solder pins,.7 and.8 wiring posts 0.6 mm Mounting versions.0 on PCB,.7 with wiring posts,.8 with catch spring Mounting position horizontal figure wheel shaft Protection class (DIN 4050) IP 66, versions.7 and.8 only at front, connections IP 00 Shock stability > 3500 m/s 2 acc. to IEC 068-2-27 Weight approx. 10 g Time error with disable per switching cycle 0.488 ms Type 0633.0 + 1 3 5 2 - Type 0633.7/0633.8 + 1 2 6 7 - Disable-Eingang input Disable-Eingang input + VDC 0V + VDC 0V Activation: The counter is connected to 0 V and + VDC. The counter is switched off by connecting Pin 2 with Pin 7 or Pin 3. 214 Components 2003/2004 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Technical data Type 633-DC Type 633.0 Typ 633.8 Time counters/ Timer relays ORDER INFORMATION Counter Accessories Current consumption Type 633.0 Type 633.7 Type 633.8 Voltage Ohm during pulse Ord. code Ord. code Ord. code 5 VDC 140 35 ma 0 633 031 0 633 731 0 633 831 12 VDC 720 17 ma 0 633 032 0 633 732 0 633 832 24 VDC 1140 9 ma 0 633 033 0 633 733 0 633 833 Flying lead 150 mm red 1 634 008 1 634 008 Flying lead 150 mm black 1 634 007 1 634 007 Components 2003/2004 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS 215

Type 633-DC Miniature Time Counter for 35 mm DIN Rail Attachment Miniature size Screw terminal connection Suitable for switch cabinet installation Snap-on attachment for 35 mm DIN rail 7-digit, 0... 99999.99 h Supply voltage V op acc. to order information, tolerance + 10 % Current consumption during pulse voltage 35 ma 5 VDC 17 ma 12 VDC 9 ma 24 VDC Residual ripple < 1 % Operating temperature 0... + 60 C Storage temperature - 40... + 70 C Protection class (DIN 4050) IP 10 Shock stability > 3500 m/s 2 acc. to IEC 068-2-27 Weight approx. 40 g Time error with disable 0.488 ms per switching cycle connection without disable 1 = + VDC 2 = 0V with disable 1 = + VDC 4 = 0V 2 = disable ORDER INFORMATION Time counter for supply voltage 5 VDC 0 633 531 Time counter for supply voltage 12 VDC 0 633 532 Time counter for supply voltage 24 VDC 0 633 533 216 Components 2003/2004 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS

Time Counter mini "h", AC Version Type 633-AC Miniature dimensions Quiet operation Protection class IP 65 6-digit, 0... 99999.9 h Supply voltage Vop acc. to order information, tolerance + 10 % Power consumption 24 V 0.08 VA, 115 V 0.56 VA, 220 V 1 VA Operating temperature - 10... + 50 C Storage temperature - 25... + 70 C Humidity 75 %, without condensation El. connection depending on version screw terminal connection for cables up to 2.5 mm 2 or 250 mm long connecting cable, AWG 28 or AMP 2.8 x 0.8 mm Mounting with clamping frame Mounting position horizontal figure wheel shaft Protection class (DIN 4050) Version.8: front IP 66, connections IP 40 (touchproof) Shock stability 800 m/s 2 (6 ms) acc. to IEC 068-2-27 Noise level approx. 40 db (distance 25 cm) Time counters/ Timer relays VAC M Components 2003/2004 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS 217

Type 633-AC Technical data Screw terminals Connecting cable AMP connector ORDER INFORMATION Counter Voltage Screw Connecting terminals cable 24 V 50 Hz 0 633 811 0 633 821 115 V 50 Hz 0 633 813 0 633 823 115 V 60 Hz 0 633 814 0 633 824 220 V 50 Hz 0 633 815 0 633 825 Other voltages on request Accessories panel frame 24x36 mm (insert dimensions 22 x 36 mm) Ordering code 1 405 674 218 Components 2003/2004 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS