Voltage Sag Simulator

Similar documents
Voltage Dip-Proofing Inverter

Voltage Dip-Proofing Inverter

Voltage-Dip Proofing Inverters

Earth Continuity Monitor

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Q9 ASD LOW VOLTAGE DRIVE

SMARTONLINE E3 UPS SYSTEMS

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

RT4F-110V/25A RECTIFIER

ADJUSTABLE SPEED DRIVES. Q9 Series

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

SLI 15 INVERTER SERIES, 1500 W

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

RT4F-48V/50A-WAC RECTIFIER

407B 1/16 DIN Multi-Mode Timer

Voltage Sag Mitigation Methods 10/28/09 1:15 pm 2:00 pm

RT4F-120V/20A-WAC RECTIFIER

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

SE-701 MANUAL GROUND-FAULT MONITOR

ASCO 920 Remote Control (RC) Switches

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

RT12-240V/2.4kW Rectifier Specification

RT4B-110V/12A RECTIFIER

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Solid-state Timer H3YN

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

920 Remote Control (RC) Switches

Premium Online Series

Medium Voltage Metal-Enclosed Power Capacitor Banks

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

PACSystems RX3i IC695PSA140

405A Timer with Instantaneous Relay

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Quantum Chargers Enhanced AC Line Transient Immunity

Bus Bar Protection Relay B-PRO 4000

ECE 528 Understanding Power Quality. Paul Ortmann (voice) Lecture 23

Circuit Breaker Operation & its load calculations

Magnetically Actuated Safety Interlock Switches

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Medium Voltage Metal-Enclosed Harmonic Filter Systems

VLT 2800 DRIVE SPECIFICATIONS

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

Purpose of High Voltage Circuit Switchers

INSTRUCTION MANUAL FOR BREAKER FAILURE RELAY BE1-50BF. BE1-50BF BREAKER FAILURE RELAY Style No. XXX XXX XXXXX Serial No. HXXXXXXX

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Uninterruptible Power Supplies

IPS INTELLIGENT PUMP STARTER

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

D64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Series 230 Automatic Transfer Switch

T4HD: Installation Supplement R8.1.13

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Installation Manual for D244X Series 24-volt Power Supplies

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

2U/5U. AC + DC Power Solutions. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

Solid State Remote Power Controller E /627

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers

SM100. On-Line Switchgear Condition Monitoring

Product Specifications

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

NETRONICS HS3500 CONTROLLER

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

FEATURES DESCRIPTION FEATURES

DPM Digital DC Power Meter with Data logging capability. User Manual

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

Programmable laboratory power supplies direct from the manufacturer

SmartOnline 120V 1.5kVA 1.35kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Oversize Internal Batteries, Network Card Slot, LCD, USB, DB9

APL/UPL, 205/295 Series Magnetic Circuit Protectors

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Safety Standards. Model Number:

MiniEVR Electronic Voltage Regulator-Power Conditioner (MEVR)

PowerFlex 400 AC Drive Guide Specification

DEEP SEA ELECTRONICS PLC

SENTRY HPS / HTS COMMUNICATION PROTOCOL

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

Transcription:

For use with all DPI s & VDC s 120/208/240V 50/60Hz LEADERS IN VOLTAGE-DIP PROOFING

Contents Introduction to the DPI... 3 Theory of DPI operation... 3 Description -... 4 Operation... 5 Sag Simulation... 5 Variac Output... 8 Soak Test... 8 Simulated Sag Profile... 12 Sag Simulator Specifications... 13 Sag Simulator block diagram... 14 Controls & indicators... 14 Typical test setup... 15 Mechanical Outline... 16 Accessories... 17 Notes:... 19 Page 2

Introduction to the DPI The reliability of electrical power to industry is in general very high; nevertheless, brown outs and short power interruptions or voltage dips occur. These instabilities are caused by short circuits, lightning strikes on overhead power lines and heavy load switching. The duration of such faults is generally shorter than one second. Most plant can ride through such voltage dips by virtue of their mechanical and electrical inertia. However, this is not the case with electrically held-in contactors and relays that control the machinery. Contactors typically drop out from 5ms to 20ms after power is removed. Each short voltage dip now becomes a power failure and the plant must be restarted. This can be complicated, time-consuming and costly. TECHNOLOGIES VOLTAGE-DIP PROOFING INVERTERS are designed to maintain the switchgear control voltage during voltage dips, effectively keeping the plant connected. The stored electrical and magnetic energy is allowed to flow, supporting the mechanical inertia of the machinery. When the power is restored after a short voltage dip, the plant is still running at near synchronous speed, the inrush currents will be small and the stress to the system minimal. Historically, this problem has been addressed by using DC contactors, latched contactors and intelligent controls such as PLC s. These systems are complex and expensive and do not provide a solution for equipment already in existence. The current approach to this problem has been to employ intelligent control systems which provide a curative solution. In contrast, the Voltage-Dip Proofing Inverter, provides a preventative solution. Theory of DPI operation The VOLTAGE-DIP PROOFING INVERTER is designed to be maintenance free and highly reliable. It consists of a static switch in series with, and an inverter parallel to, the load. Energy is stored in a capacitor bank; the inverter block diagram is shown in Fig 1. Static Switch Inverter Supply Storage Capacitor Load Fig 1 Inverter Block Diagram Page 3

The STATIC SWITCH is robust and can withstand large current surges. It is ideally suited for contactor operation where high peak currents of short duration occur during energizing. The INVERTER is configured as a full bridge with overcurrent and short circuit protection. The output waveform is a square wave where the RMS and the peak voltage are the same as for a sine wave, as shown in Fig 2. V t Fig 2 Inverter stepped square wave output waveform This is important for circuits where magnetic devices, such as transformers and contactors (RMS voltage) are in circuit with electronic relays that derive their DC voltage from capacitor input filters (peak voltage). The computer grade CAPACITOR BANK operates under ideal conditions, being charged to working voltage but carrying no ripple current most of the time. During stand-by operation, the static switch supplies power directly to the load, the inverter is switched off and the capacitors are charged to the full operating voltage. The supply voltage is constantly monitored for deviations; should there be a deviation from Vnom which is greater than the preset value, the static switch is switched off and the inverter is activated. The switch-over is accomplished in less than 700µs. A 3.1 second timer, adjustable in increments of 100ms, starts timing the inverter out. Should the input voltage recover within the set time, the inverter supply is synchronized to the mains and the load is switched back to the supply, the capacitors are recharged in less than one second and the inverter is ready to compensate for the next voltage dip. If the input voltage does not recover within the set time the load is switched back to the supply regardless of the voltage level. Description - The Sag Simulator is intended to be used as a tool to evaluate the effects of momentary voltage sags and interruptions on industrial controls. When used in conjunction with a Voltage Dip-Proofing Inverter or a Voltage Dip Compensator and Bypass switch, it may be used to prove the effectiveness of the DPI or VDC as a solution for these power quality problems. The Simulator has two other useful functions that may be selected via the Function Select menu, Page 4

a Variac Output that enables direct output from the variac and a Soak Test function that may be used to perform repetitive testing. The Sag Simulator is designed for 120/208/240Vac operation. The main controls and their functions are listed below, refer to Fig 7 page 14 for their locations :- 1. A variac that is used to set the depth of an under voltage (sag) condition. 2. The sag level set by the variac is indicated on the LCD display. 3. A variable interrupt timer that is used to set the duration of the voltage sag and the point in the cycle at which it begins. Both variables are set using the programming keys and are indicated on the LCD display. Refer to the menu flow chart and programming key function table in Fig 3 p7 for Sag Simulation, page 8 for Variac Output and Fig 4 p11 for Soak Test. Operation Sag Simulation Follow the steps outlined below to set up and operate the Sag Simulator. Refer to Fig 3 on page 7 for information on menu layout and programming key functions. 1. Connect the supply, Voltage Dip-Proofing Inverter or Voltage Dip Compensator, Bypass Switch and load to the Sag Simulator as shown in Fig 8 page 15. 2. Set the variac to zero output and the Bypass Switch to Inverter Bypassed. 3. Switch on the power to the Sag Simulator; the display will show: SAG SIMULATOR AND SOAK TESTER SELF TEST PASSED! FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST Note: If an error message is displayed and the Simulator shuts down please refer to Error conditions at the end of this section on page 10. 4. Press the key to reach the Sag Simulator menu; the display will show: SAG SIMULATOR 1 START TEST 2 SET PARAMETERS 5. Press the key to reach the Start Test display; the display will show: START TEST VOLTAGE: 000Vac DELAY: 05.0ms DURATION: 1.000s Page 5

6. The Sag Depth may be adjusted using the Variac prior to performing the test. The value is shown on the Voltage readout. In this case preset values are used for Sag Delay (5ms) & Sag Duration (100ms). The simulator will store the values used for the last test and use them as the defaults for the next test. 7. Press the key to Start Test or press the key to return to the Sag Simulator menu. 8. To set the Sag Parameters to values different to the defaults navigate to the Sag Simulator menu, press the key to select Set Parameters then press the key to reach the adjustment menus. The Sag Depth is set using the variac and then the interrupt timer should be programmed to set the position and duration of the voltage sag to be generated. The three parameters are adjusted as follows :- 8.1 Set Sag Depth: At the Set Sag Depth Menu press the key to reach the Adjust Variac menu. Adjust the variac until desired voltage is indicated on the display. 8.2 Set Sag Delay position after a positive zero crossing: At the Adjust Variac menu press the key to select the Set Sag Delay menu. Press the key to program the Sag Delay value. Use the and keys to select the digit to adjust. The active digit will flash. Use the keys to increment or decrement the digit to the desired value. 8.3 Set Sag Duration: From the Set Sag Delay menu press key to select the Set Sag Duration menu. Press the key to program the Sag Duration value. Use the and keys to select the digit to adjust. The active digit will flash. Use the keys to increment or decrement the digit to the desired value. 9. Start Test: When the Sag Voltage, Delay and Duration have been set navigate back to the Sag Simulator menu by pressing the key. Press the key to reach the Start Test menu. At this point the variac may be used to readjust the sag voltage. The voltage setting will be indicated on the display. The supply voltage can be interrupted by pressing the key. The effect of the programmed sag can be seen on the unprotected load; one or more contactors or relays will drop out. The sag profile can be observed using a power monitor or an oscilloscope if these are available. The simulation can be tried with various settings (sag depth, delay and duration) as often as desired to pinpoint sensitive components in the control system. 10. Test with DPI or VDC in circuit: The Bypass Switch should now be set to Inverter in Circuit and the sag simulations repeated to evaluate the effectiveness of using the Voltage Dip-Proofing Inverter or Voltage Dip Compensator to harden the controls against momentary sags and interruptions. 11. Sync pulse output: A synchronization pulse is available at terminals 4 & 5. This pulse may be used to trigger an oscilloscope in order to display the sag profile. The output remains at zero volts until a sag is initiated at which time the output rises to 5 volts and remains at this level until the end of the sag duration period. The output then returns to zero volts. The sync pulse output is electrically isolated. Page 6

SELF TEST PASSED! Displays for 3 sec. FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST Power on error messages. SUPPLY FREQUENCY NOT 50 or 60Hz! SWITCH OFF AND ON TO RETRY. CURRENT OVERLOAD OR SHORT CIRCUIT! SWITCH OFF AND CHECK THE LOAD. SYSTEM FAILURE! PLEASE CONTACT SAG SIMULATOR AND SOAK TESTER. Displays for 3 sec. Power on - start. SAG SIMULATOR 1 START TEST 2 SET PARAMETERS SAG SIMULATOR 1 START TEST 2 SET PARAMETERS SET SAG DEPTH VOLTAGE: DELAY: DURATION: 154Vac 05.0ms 1.000s SET VOLTAGE: 154Vac SET THE SAG DEPTH BY ADJUSTING THE VARIAC SET SAG DELAY VOLTAGE: DELAY: DURATION: 154Vac 05.0ms 1.000s DELAY: 05.0ms SET POINT WHERE SAG STARTS AFTER A ZERO CROSSING SET SAG DURATION VOLTAGE: DELAY: DURATION: 154Vac 05.0ms 1.000s DURATION: 1.000s SET SAG DURATION Fig 3 Programming key function table & Sag Simulator menu flowchart. START SAG TEST VOLTAGE: DELAY: DURATION: 154Vac 05.0ms 1.000s >>> TESTING >>> VOLTAGE: DELAY: DURATION: 154Vac 05.0ms 1.000s Displays for duration of sag. Key Menu navigation Next menu right Next menu left Next menu above Next menu below Set value Next digit Previous digit Increment digit Decrement digit Page 7

Variac Output 1. Output direct from variac: At times it is convenient to have a variable AC supply available. The Sag Simulator can be programed to connect the variac output to terminal 3. In this mode the output voltage is set by the variac and is available continuously; the set value is indicated on the display. The output is overload and short circuit protected. To enable direct variac output navigate to the Function Select Menu. Select Variac Output and press the key. The display will show: FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST SET VOLTAGE: 000Vac VARIABLE OUTPUT DIRECT FROM VARIAC SET VARIAC TO 0Vac. DISCONNECT THE LOAD. SWITCH OFF THEN ON TO RESET. 2. To exit Variac Output mode first set the variac output to zero and disconnect the load. Then switch the Sag Simulator off and then on to reset to normal operation. Soak Test Follow the steps outlined below to set up and operate the Soak Tester. Refer to Fig 4 on page 11 for information on menu layout and programming key functions. 1. Connect the supply, Voltage Dip-Proofing Inverter or Voltage Dip Compensator, Bypass Switch and load to the Sag Simulator as shown in Fig 8 page 15. 2. Set the variac to zero output and the Bypass Switch to Inverter in circuit. 3. Switch on the power to the Sag Simulator; the display will show: SAG SIMULATOR AND SOAK TESTER SELF TEST PASSED! FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST Note: If an error message is displayed and the Simulator shuts down please refer to Error conditions at the end of this section on page 10. 4. Press the key twice to select Soak Test then Press the key to reach the Soak Test menu; the display will show: SOAK TEST 1 START TEST 2 SET PARAMETERS 5. Press the key to reach the Start Test display; the display will show: START SOAK TEST SET VOLTAGE: 000Vac INT SDUR EDUR STEPS 010 0100 1000 0200 Page 8

6. The Sag Depth may be adjusted using the Variac prior to performing the test. The value is shown on the Voltage readout. Stored values are used for : 6.1 INT - Interval between consecutive dips - initial default = 10 seconds 6.2 SDUR - Duration of the first test dip - initial default = 100ms 6.3 EDUR - Duration of the last test dip - initial default = 1000ms 6.4 STEPS - Number of steps between first dip & last dip - initial default = 200 6.4.1 Each step consist of a series of 20 dips. The first dip starts at zero crossing, the next dip is delayed by the period of the supply frequency divided by 20. Subsequent dips sweep through a complete cycle with increasing delays after zero crossing. 6.5 Note that the values shown above are factory settings for first use. When parameters are set up for a test the new values are stored and will become the default values for the next test. 7. Press the key to Start Test or press the key to return to the Soak Test menu. 8. To set the Soak Test Parameters to values different to the defaults navigate to the Soak Test menu, press the key to select Set Parameters then press the key to reach the adjustment menus. Five parameters may be adjusted as follows :- 8.1 Set Dip Interval: At the Set Dip Interval menu press the key to program the Dip Interval value. Use the and keys to select the digit to adjust. The active digit will flash. Use the keys to increment or decrement the digit to the desired value. 8.2 Set Start Dip Length (t Start) : At the Set Dip Interval menu press the key to select the Start Dip Length menu. Press the key to program the Start Dip length value. Use the and keys to select the digit to adjust. The active digit will flash. Use the keys to increment or decrement the digit to the desired value. 8.3 Set End Dip Length (t End): From the Set Start Dip Length menu press key to select the Set End Dip Length menu. Press the key to program the End Dip Length value. Use the and keys to select the digit to adjust. The active digit will flash. Use the keys to increment or decrement the digit to the desired value. 8.4 Set Number of Steps: From the Set End Dip Length menu press key to select the Set Number of Steps menu. Press the key to program the Number of Steps value. Use the and keys to select the digit to adjust. The active digit will flash. Use the keys to increment or decrement the digit to the desired value. 8.5 Set Sag Depth: The Set Sag Depth is set from the Start Soak Test Menu. Set Voltage will flash and the current sag level voltage will be displayed. Adjust the variac to the desired Sag Depth value. The value may be adjusted at any time during testing. Page 9

9. Start Test: When the parameters have been set navigate back to the Soak Test menu by pressing the key. Press the key to reach the Start Soak Test menu. Set Voltage will flash; use the variac to adjust the Sag Depth voltage (see 8.5 above). Start the Soak Test by pressing the key. The display will show: >>>SOAK TESTING >>> VOLTAGE: 000Vac TIME TO END: 000h00m DIP 00000 OF 00000 10. Stop or interrupt the test by pressing the key. The display will show: SOAK TEST STOPPED! SET UP NEW TEST? OR TESTING WILL RESUME IN 30 SECONDS. Press the key to stop the test and return to the Soak Test Menu. If no action is taken testing will resume in 30 seconds. 11. When the test is complete the total number of dips are displayed. SOAK TEST COMPLETE! TOTAL NUMBER OF DIPS 0000 Press the key to return to the Soak Test Menu. Start up error conditions 1. Error conditions: The simulator will perform a power on test to check the supply frequency and the load current. If the supply frequency is not 50 or 60Hz or if there is an overload then one of the error messages below will be displayed: SUPPLY FREQUENCY NOT 50 or 60Hz! SWITCH OFF AND ON or TO RETRY. CURRENT OVERLOAD OR SHORT CIRCUIT! SWITCH OFF AND CHECK THE LOAD. When an error condition is detected the simulator will shut down automatically and the error message will remain on the display. Check the test setup for the source of the problem. To reset the simulator switch the power off and then back on again. Page 10

SELF TEST PASSED! Displays for 3 sec. FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST TOTAL NUMBER OF DIPS TEST TIME: 001h06m # OF DIPS: 00200 INTERVAL: 0010s TOTAL TEST RUN TIME # OF STEPS:0010 TEST TIME: 001h06m # OF DIPS: 00200 SAG SIMULATOR AND SOAK TESTER. Displays for 3 sec. Power on - start. SOAK TEST 1 START TEST 2 SET PARAMETERS SOAK TEST 1 START TEST 2 SET PARAMETERS SET DIP INTERVAL # OF DIPS: INTERVAL: t START: 00200 010s 0100ms INTERVAL: 010s SET INTERVAL BETWEEN CONSECUTIVE DIPS SET START DIP LENGTH INTERVAL: t START: t END: 010s 0100ms 10000ms t START: 0100ms SET THE DURATION OF THE FIRST TEST DIP SET END DIP LENGTH t START: t END: # OF STEPS: 0100ms 1000ms 0200 t END: 1000ms SET THE DURATION OF THE LAST TEST DIP SET NUMBER OF STEPS t END: 1000ms # OF STEPS: 0010 TEST TIME: 001h06m # OF STEPS: 0010 SET NUMBER OF STEPS BETWEEN t START AND t END Fig 4 Programming key function table & Soak Tester flowchart. START SOAK TEST SET VOLTAGE: 000Vac INT SDUR EDUR STEPS 010 0100 1000 0200 Displays for duration of soak test. >>>SOAK TESTING >>> VOLTAGE: 000Vac TIME TO END: 000h00m DIP 00000 OF 00000 SOAK TEST COMPLETE! TOTAL NUMBER OF DIPS 0000 SOAK TEST STOPPED! SET UP NEW TEST? OR TESTING WILL RESUME IN 30 SECONDS. Displays for 30s. Key Menu navigation Next menu right Next menu left Next menu above Next menu below Set value Next digit Previous digit Increment digit Decrement digit Page 11

Simulated Sag Profile Supply V 300 200 Positive zero crossing Sag Depth 50% Sag Duration 60ms Sag Voltage 110Vrms 100 0-100 -200-300 Sag Delay 5ms Supply voltage - 220V 50Hz Sag Simulator output V Sync 5 0 10 20 30 40 50 60 70 80 90 100 Time ms Sync pulse output Terminals 4 & 5 0-5 Amplitude = 5V Duration = 60mS = Sag Duration 0 10 20 30 40 50 60 70 80 90 100 Time ms Fig 5 Profile of simulated sag output & sync pulse from simulator. Page 12

Sag Simulator Specifications AC INPUT SUPPLY Supply voltage: 120/208/240Vac 50/60Hz Maximum input voltage: +10% Full load current: 20A VARIAC CONTROL Variac range: Maximum power: Maximum continuous current: Maximum short term current for 3 seconds: Overload & short circuit protection: DIRECT VARIAC OUTPUT Variac range: Maximum power: Maximum continuous current: Overload & short circuit protection: 0-240Vac RMS 1200VA @ 120V / 2400VA @ 240V 10A 20A Yes 0-240Vac RMS 1200VA @ 120V / 2400VA @ 240V 10A Yes SAG DELAY TIMER Range: Setting: SAG DURATION TIMER Range: Setting: CONTROLS & INDICATORS Programming: Menu/parameter indication: SYNC PULSE OUTPUT Amplitude: Polarity: Electrically isolated output: Duration: 0.00 to 20.00 ms 0.01 ms steps 0.010 to 9.999 seconds 0.001 second steps Four push switches 4 x 20 LCD display 5V Positive Yes Equal to sag duration TEMPERATURE Maximum ambient working temperature: 45 C (113 F) HOUSING Construction: Extruded aluminium Height: 390mm (15.35in ) Width: 311mm (12.24in) Depth: 162mm (6.38in) Mass: 15kg (33lb) Page 13

Sag Simulator block diagram 5 Controls 4 4 x 20 Display Line Program Switches 1 Static Switch 1 3 Sync pulse Amplitude = 5V Duration = Sag duration Set sag level Supply Static Switch 2 Load Variac V Sag voltage Common 2 Fig 6 Sag Simulator block diagram Controls & indicators FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST 100 120 140 80 160 60 180 40 200 20 220 Line in (Supply) 0 240 Common Line Line out (Load) 1 2 3 4 5 Sync out 5V Fig 7 Controls & indicators Page 14

1 2 3 Connection to Inverter Inverter in Circuit Housed Bypass Switch Inverter Bypassed Line In (Supply 120/208/240V) Common line System Inverter OK Running Voltage-Dip Proofing Inverter Line in Common Line Line out (Supply) (Load) 1 2 3 Ground 1 2 Common Line In Line Out 1 2 3 Connection to Supply Line Out (Load) Common line 1 2 3 Typical test setup FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST Line in (Supply) Common Line Line out (Load) 1 2 3 Motor Control Centre or load under test B1 B2 B3 Stop Stop Stop Start Start Start Interlock Interlock Interlock C1 C2 C3 140 120 100 80 160 180 60 200 40 220 20 240 0 4 5 Sync out 5V Fig 8 Sag Simulator connection diagram. Page 15

Mechanical Outline Ø 8mm (0.31") 311mm (12.24") 298mm (11.73") FUNCTION SELECT 1 SAG SIMULATOR 2 VARIAC OUTPUT 3 SOAK TEST M6 60 40 80 SAG SIMULATOR MODEL SERIAL # 20 100 Line in (Supply) 0 Common Line 1 2 3 VOLTS POWER 120 240 140 220 160 Line out (Load) 180 200 4 5 Sync out 5V 162mm (6.38") 390mm (15.36") DATE MFG HZ 311mm (12.24") Fig 9 Dimensions of the Sag Simulator (in mm/inches) Page 16

Accessories Housed Bypass Switch 10A 1. Description Where no-break maintenance is required a by pass switch must be installed. It connects the supply directly to the load, "Bypass" position, and disconnects the power terminals of the inverter without interrupting the supply. When in "DPI" position the load is connected to the supply via the inverter. 2. Specifications Maximum Current : 10A Maximum voltage : 500Vac Enclosure : Extruded Aluminium Dimensions : Length : 143 (5.63); Width : 150 (5.90); Height : 140 (5.51) Mounting: 2 M6 holes Mass: 0.72kg (1.58lbs) For use with DPI models: DPI52S25-12 : DPI52S25-23 : DP52S50-12 DPI52S50-23 : DPI52L1K12 : DPI52L1K-23 3. Mechanical outline 31 (1.22) 1 2 3 22.0 (0.87) To DPI or VDC Line in 1 2 3 Common Line DPI Line out 50 (1.97) 110 (4.33) Line in (Supply) Common Line Bypass Line out (Load) 50 (1.97) 100 (3.94) To Supply 1 2 3 140 (5.51) 150 (5.90) 1 Note 1: Dimension units. Without brackets - mm. With brackets - inches. 2 3 22.0 (0.87) Note 2: Mounting holes 2 x 6 (0.25)Ø. 4. Ordering Stock No: 187 Description: Housed Bypass Switch 10A Page 17

Accessories Housed Bypass Switch 40A 1. Description Where no-break maintenance is required a by pass switch should be installed. It connects the supply directly to the load, "Inverter Bypassed" position, and disconnects the power terminals of the inverter without interrupting the supply. When in "Inverter in circuit" position the load is connected to the supply via the inverter. 2. Specifications Maximum Current : 40A Maximum voltage : 500Vac Enclosure : Extruded Aluminium Dimensions : Length : 173 (6.81); Width : 152 (5.90); Height : 142 (5.59) Mounting: 2 M6 holes Mass: 1kg (2.2lbs) For use with models: DPI52L2K12 : DPI52L3K23 : DPI52L3K12 : DPI52L4.5K23 3. Mechanical outline 32 (1.26) 1 2 3 26.5 (1.04) To DPI or VDC Line in 1 2 3 Common Line DPI Line out 60 (2.36) 110 (4.33) Line in (Supply) Common Line Bypass Line out (Load) 60 (2.36) 120 (4.72) To Supply 1 2 3 140 (5.51) 150 (5.90) Note 1: Dimension units. Without brackets - mm. With brackets - inches. 1 2 3 26.5 (1.04) Note 2: Mounting holes 2 x 6 (0.25)Ø. 4. Ordering Stock No: 163 Description: Housed Bypass Switch 40A Page 18

Notes: Rev. 1.3 November 6 th, 2003 : LPW Page 19

For use with all DPI s & VDC s 120/208/240V 50/60Hz Motor Control Centre Voltage-Dip Proofing Inverter B1 B2 B3 1 Static Switch 3 Stop Stop Stop Bridge Inverter Storage Capacitor Start Start Start Main Breaker 2 Bypass Switch Interlock Interlock Interlock Line Voltage Control Voltage C1 C2 C3 A typical DPI connection diagram LEADERS IN VOLTAGE-DIP PROOFING Measurlogic Inc. 2200 Chambers Road, Aurora, CO 80011, USA Tel:303-364-4368 Fax:425-799-4780 E-mail: info@measurlogic.com web: www.measurlogic.com