RCM Room Command Module New Style

Similar documents
TM-2100 Series Room Command Module

TM-2100 Series Room Command Module

TC-8900 Controller Units with PM-8900 Power Modules

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Field selectable application type and room module series, via dip-switches on controller

TC-9102 Terminal Controller

MODEL 2000T Initial Draft

LX Series Remote Input/Output (I/O) Controller

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

DX-9100 Digital Controller, Version 2

FX Input/Output (I/O) Modules XM07 and XM14

FX06 Field Controller

FXVMA Variable Air Volume (VAV) Box Controller

Medium User Interface (MUI) Version 3

LN Series Remote Input/Output (I/O) Modules

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

LONWORKS Compatible DX-9200 Digital Controller

VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications

Extended Digital Controller

Packaged Fresh Air Unit With Tracer LCI-I

Series A19A/A19B/A19D. Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

CTR21, CTR22, CTR23, and CTR24 Wall Modules

FX14 Field Controller

Excel 10 W7751B,D,F VAV II Controllers

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Allure EC-Smart-Comfort Series

Allure EC-Smart-Comfort Series

Room unit with PPS2 interface

TAC Xenta 121-FC Programmable Fan Coil Application

LX Series Application-Specific Controllers

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

N2 Dialer Module. Features and Benefits

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

CORRIGO R10. LonMark Functional Profile: Chilled Ceiling Controller Corrigo R10 LonWorks Interface: LonMark Chilled Ceiling Controller

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Stryker Lon Configurable Controllers

Field Advanced Display

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

P216 Series Condenser Fan Speed Controller

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

P216. Condenser fan speed controller. Product bulletin. Features

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

Room unit with PPS2 interface

Satchwell MicroNet. Building Management System MicroNet 50 Series

T7560A1036 Digital Wall Module

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

C7110C1001A / C7110D1009A WALL MODULES

S66 Series Electronic Fan Speed Control

Excel 12 INTEGRATED ROOM CONTROL SOLUTIONS: FCU + LIGHT + SUNBLIND

TAC Xenta 121-HP Programmable Heat Pump Application

KITS AND ACCESSORIES. Prodigy LonTalk MODULE KIT INSTALLATION INSTRUCTIONS FOR LONTALK MODULE KIT (54W27) USED WITH ENERGENCE ROOFTOP UNITS.

Room unit with PPS2 interface

Network Control Engine Catalog Page

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NEUROLOGIC RESEARCH CORPORATION MODEL 1160 INITIAL DRAFT INDOOR TEMPERATURE NETWORK TRANSMITTER

Smart Equipment Controls (SEC)

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

Excel 12 INTEGRATED ROOM CONTROL SOLUTIONS: FCU + 4 LIGHTS FEATURES GENERAL PRODUCT DATA. Excel 12

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

HE-6800 Series Humidity Transmitters with Temperature Sensor

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Product and Application Description

DP DP2500 DP0250

Installation- & user instructions

Software Application wrf08_03 (Lighting, Blinds, Air-Conditioning Control) For model WRF08 T6 T8 T5 T6 T7 T8. Messwert Value

T7560A,B,C Digital Wall Module

Modular Room Control (MRC) Series Expansion Board

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

Room unit with PPS2 interface

MODEL 1600 FEATURES DESCRIPTION WIRING AND INSTALLATION NETWORK DISPLAY

PCM2001N Software Users Guide Version 1 Draft 3 Mar. 2004

MicroTech 2000 Water Source Heat Pump Unit Controller Protocol Information

LX Series Free Programmable Controllers

Excel 12 INTEGRATED ROOM CONTROL SOLUTIONS: FCU + LIGHT + SUNBLIND

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Excel 12 INTEGRATED ROOM CONTROL SOLUTIONS: FCU + LIGHT

BA/BS4S Temperature Sensor Installation & Operating Instructions

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. January 2005

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. September 2001

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

SmartX Living Space Sensors

UCU Room Display. Operation Modes. Features. Applications DATASHEET

LN Series Communicating Sensors

Metasys N1 Network Integration

Lab and Central Plant Controller

T7560A,B,C Digital Wall Module

FX05 Controller. FX05 Controller. Features and Benefits Compatible with standard BAS protocols. LON and N2Open plug-in comm.

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Stryker Lon Configurable Controllers

VA-748x Electric Valve Actuators

Input/Output Module (IOM) Series Catalog Page

FX Tools Express Software Package

Manual PCD7.L611 room controllers LON

Room Temperature Controller

Transcription:

LONWoRKS Compatible Controllers Manual Product Bulletin Issue Date 08 2005 RCM Room Command Module New Style The newly styled RCM Room Command Module is designed for use with LONMARK compliant space comfort controllers such as the TCU fan coil unit and VMA variable air volume box controllers from Johnson Controls. An LCD display, dial and pushbutton on the front of the module allow the room occupant to view and adjust the space temperature and fan speed. The module will automatically request the temporary occupied (bypass) mode when the dial or pushbutton is moved during unoccupied or standby periods. The RCM connects directly to the LONWORKS network and complies with the LONMARK interoperability guidelines for sharing data with other LONMARK compliant network devices. It is available with FTT-10 free topology transceivers or LPT11 link power transceivers, for a twistedpair physical network configuration. Figure 1: RCM Room Command Module Features and Benefits Compact display for space comfort data using standard symbols One dial and one button for all parameter changes Multiple configuration options to enable or disable display and override functions Override functions can be reset and disabled from the network All options set by LONMARK configuration properties LONMARK Space Comfort Controller Command Module Profile Option for LPT11 LONWORKS network transceiver Display is back lighted with time out Easy to read and understand -- independent of user language. Simple and intuitive to use. Can be customized for different applications office areas, hotel rooms, for example. Remote override of user access from a central control station. Configured with any LONWORKS compatible network tool. Interoperates with other LONMARK certified devices. Ease of installation -- only two wires to connect for network and power. Suitable for dimly lit locations. 2004 Johnson Controls, Inc. 1 Order No. MN-LCC-202

E nvironmental and Comfort Data for the Occupant The room command module can be configured to normally display one of the following values: The maintenance symbol on the display can be configured to indicate one of the following: Space temperature Space temperature setpoint When the occupant is adjusting the set point dial, the setpoint is always displayed. If the connected controller controls a fan, the occupant can also view: Fan speed (off, low, medium. high) Fan mode (AUTO or manual OFF) Alarm condition from the controller Condensation on chilled ceiling pipes Temperature sensor failure When the controller is not in occupied mode, the display can be set to a slow blink cycle. Moving the dial or pushbutton will set the controller into temporary occupied mode and the display will go steady. When the controller is in OFF mode, because a window is open for example, the temperature display area will show OFF. C ontrolling Comfort and the Environment The room command module can also be configured to allow the occupant to adjust or override operating parameters of the connected controller. Set point adjust The set point of the controller can be adjusted for a warmer or cooler temperature within the range of ± 3 C (± 5.4 F) or to a specific temperature within a range of values such as 12 to 28 C or 54 to 82 F, as specified in the configuration properties, using the dial on the face of the module. Fan speed manual override The user can press the fan pushbutton to change the fan speed. The actual fan status is shown by the speed bars and the AUTO symbol disappears to confirm a manual override condition. When the fan is stopped in the manual mode, the OFF symbol appears. Pressing the pushbutton until the AUTO symbol appears cancels a manual override and restores automatic fan speed control according to the room temperature and setpoint. Temporary occupancy button Outside of the normal occupancy periods, in the evening or on the weekend for example, one touch on the dial or pushbutton will give the occupant comfort conditions for a set period of time. If desired, the display can be configured to slowly blink when the controller is not in occupied or temporary occupied mode. Centralized lock-out and reset With a command over the network from a central control station, all user override functions can be locked out and manual overrides reset. 2 Product Bulletin RCM Room Command Module

C onfiguration Options for Customized Control Depending on the use of the room or the type of building, the requirements for display and override will vary. The RCM has the following configuration options for these different applications. Enable space temperature display Set point as absolute or warmer/cooler Enable fan speed display and override Enable unoccupied display blink Adjust temporary occupancy period Select temperature units ( C or F) Adjust back light time out Enable maintenance symbol In a standalone application, a user-owned apartment, for example, all features might be enabled. In an office environment with centralized monitoring and control, only the display options may be enabled. In a hotel room functions may be limited to temperature set point and fan speed adjust with an automatic return to default settings when the room is vacated. LON Net A LON Net B TCU RCM LON WORKS Network Variable Bindings nvospacetemp nvispacetemp nvofanspeedcmd nvosetptoffset nvooccmancmd nvieffectoccup nviunitstatus nvifanspeedcmd nvisetptoffset nvioccmancmd nvoeffectoccup nvounitstatus RCM_NVs.cdr Figure 2: Typical Network Bindings between RCM and TCU controller C onvenient Setup and Commissioning All setup parameters are available as LONMARK configuration properties and can be set by any LONWORKS compatible network tool. With the CommPro tool from Johnson Controls a record of all parameter changes can be stored in memory or on diskette and can be downloaded to multiple room command modules in one operation. As the controller is fully LONMARK compliant, it may be connected to any LONWORKS network segment using FTT10 or LPT11 transceivers and configured to communicate with a compatible space comfort controller on the network using any LONWORKS compliant network management tool. Once configured, commissioned, and connected to a network, the network inputs and outputs may be monitored and the inputs commanded from a Metasys operator workstation or other LONWORKS compatible supervisory device. The control variables and configuration parameters that are available for interoperability with other LONWORKS compatible devices on the network are listed in tables 1, 2 and 3. The typical network bindings between the RCM and a TCU controller are shown in Figure 2. Product Bulletin RCM Room Command Module 3

Table 1: RCM Network Variable Inputs Description SNVT Name SNVT Type Space Temperature Input nvispacetemp SNVT_temp_p Restricted Access nviuserlockout SNVT_switch Space Temperature Set Point Input nvisetpoint SNVT_temp_p Effective Occupancy Mode nvieffectoccup SNVT_occupancy Unit Status nviunitstatus SNVT_hvac_status Condensation Sensor nvicondensation SNVT_switch General Alarm nvigeneralstatus SNVT_switch Table 2: RCM Network Variable Outputs Description SNVT Name SNVT Type Set Point Output (absolute) nvosetpoint SNVT_temp_p Space Temperature Output nvospacetemp SNVT_temp_p (sends displayed temperature: either valid input from external sensor or value of internal sensor) Fan Speed Command nvofanspeedcmd SNVT_switch (auto, off, 1, 2, 3, or variable) Set Point Offset nvosetptoffset SNVT_temp_p Manual Occupancy Mode Request nvooccmancmd SNVT_occupancy SNVT: Standard Network Variable Type Refer to LONMARK Interoperability Guidelines for further details. 4 Product Bulletin RCM Room Command Module

Table 3: RCM Configuration Properties Description SCPT Name SNVT Type Send Heartbeat cpsndhrtbt SNVT_time_sec Minimum Send Time cpminouttm SNVT_time_sec Receive Heartbeat cprcvhrtbt SNVT_time_sec Temperature Sensor Offset cpoffsettemp SNVT_temp_p Location Label cplocation SNVT_str_asc Space Temperature Set Point High Limit cpsetpointhigh SNVT_temp_p Space Temperature Set Point Low Limit cpsetpointlow SNVT_temp_p Temporary Occupied Time cpbypasstime SNVT_time_min Fan Configuration cpfanconfig Set Point Configuration (space temperature set point as absolute or offset [± 3 C]) Enable Space Temperature Display (defines if space temperature is shown) Temperature Units (temperature display and set point units C/ F) Enable Unoccupied Mode Blink (defines if display blinks in unoccupied and standby modes) cpsetptconfig cpsptempdisplay cptempunits cpunoccblink Default Absolute Set Point (on start-up) cpdefaultsetpt SNVT_temp_p Default Restricted Access Status (on start-up) cpdeflockout SNVT switch Enable Lockout All (defines if Restricted Access also clears and locks out bypass mode) cplockoutall Back Light Time Out cpbacklighttime SNVT_time_sec Enable Maintenance Symbol cpmaintenance SNVT: Standard Network Variable Type SCPT: Standard Configuration Property Type : User Configuration Property Type Refer to LONMARK Interoperability Guidelines for further details. Product Bulletin RCM Room Command Module 5

O pen Communications and Interoperability with LONWORKS The LONWORKS communication capability of the room command module means that it can be used with a LONWORKS compatible controller and integrated into a LONWORKS network in your facility. LONWORKS is an open standard for field communications, and interoperability with other LONWORKS compatible devices is assured by the LONMARK Interoperability Guidelines. Using the LONWORKS technology in the Johnson Controls Metasys system allows you to integrate third party controllers and devices into a facility-wide management system. E ase of Installation The room command module has a separable base with wiring terminals. The base is installed first and the power and network wiring can be completed and checked before installing the electronic circuits that are located in the room module cover. This procedure provides the easiest and safest way to install the control system and avoids accidental damage to the electronic circuits when being mounted in the room on the construction site. A full range of wall and panel mounting kits are available for the room command module. 6 Product Bulletin RCM Room Command Module

Product Bulletin RCM Room Command Module 7

S pecifications RCM Room Command Module New Style Product Codes AD-RCM3205-0 Room Command Module with FTT-10 Transceiver, 24VAC Power Supply Ambient Operating Conditions AD-RCM4205-0 AD-RCM1200-8900 Room Command Module with LPT11 Link Power Transceiver RCM Service Cable 24VAC or link power from LONWORKS network (see Product Codes above). 24VAC power (FTT-10): 24VAC ±15%, 50/60 Hz at 40 ma Link power (LPT11) requires 50 ma application current at +5 VDC. 0 to 50 C / 32 to 122 F 10 to 90% RH noncondensing (and max. 30 C / 86 F dew point) Ambient Storage Conditions -20 to 70 C / 0 to 160 F 10 to 90% RH noncondensing (and max. 30 C / 86 F dew point) Terminations Terminal block with screw terminals in base for 1.5 mm 2 / 14 AWG (max.) wires. Temperature Sensor Display and Controls Communications Interface NTC Thermistor 0 to 50 C / 32 to 122 F; 10 Kohms at 25 C / 77 F; Accuracy better than ± 0.5 C / ± 0.9 F with a resolution of 0.1 C / 0.2 F. Suitable for residential and commercial office environments only. LCD display with 3 digits and 6 symbols. Dial and pushbutton. FTT-10 (Free Topology) or LPT11 (Link Power) Transceiver for LONWORKS network (see Product Codes above). Network Variable Interface LONMARK Space Comfort Control Command Module Profile (Reference 80.90) Mounting Housing Dimensions (H x W x D) Shipping Weight Standards Compliance Agency Listings Direct surface mount. Plastic base for surface mount with wiring conduits, recessed wall box and panel mounting kits available on request. Material: ABS + polycarbonate, self-extinguishing VO UL94. Protection: IP30 (IEC529) 80 mm x 80 mm x 35 mm / 3.15 x 3.15 x 1.4 inches 0.2 kg / 7 oz. CE Directive 89/336/EEC: EN 50081-1/EN61000-6-3, EN 50082-2/EN61000-6-2, FCC Class A LONMARK Certification (Pending) UL916 and CUL Listed (Pending) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products, and reserves the right to change or supplement the contents of this publication. Metasys is a registered trademark of Johnson Controls. LONWORKS and LONMARK are registered trademarks of the Echelon Corp. Johnson Controls International, Inc. Headquarters: Milwaukee, Wisconsin, USA European Distribution Centre: Westendhof 3, D-45143 Essen, Germany European Factories: Essen (Germany), Leeuwarden (The Netherlands) and Lomagna (Italy) www.johnsoncontrols.com Branch Offices Principal European Cities. Printed in Germany 8 Product Bulletin RCM Room Command Module