The Indicator with 3 Limit Contacts

Similar documents
Englisch. Operating Manual. Temperature controller 2-, 3-point- and continuous R ba_ma_r11xx-10_60-ma1-xx

Instruction Manual. Instrument Amplifier HE 017

GIR 230 TC Version 1.1

SX90 Process Controller

Tempco Instruction Manual

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Safety Temperature Limiter TT-STL 50

signo 727 SSI operating instructions

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

JUMO Quantum PID100/PID200/PID300

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

JUMO STB/STW Safety temperature limiter, Safety temperature monitor as per DIN EN 14597

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

DINALOG A 144 x 36 A1400 Light-Strip Indicator

LCI Load Cell Junction Box with Fault Monitor

Operating Instructions

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

is then retained absolutely without interruption.

Compact universal controllers

Alarm Unit DG 3200 Control And Monitor Standard Signals

LCI User Manual mantracourt.com

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

VR660 / A200R Programmable Modular Controller System

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Intrinsically Safe Barriers

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Elotech Standard Protocol. for Single R8200 SC

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

APPLICATIONS. Furnaces and ovens Burners and boilers Weighing and batching Process control Plastics processing... DESCRIPTION

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Multizones Temperature Controller Series: R2400, R2500, R4000

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Operating instructions. Standstill monitor A / / 2011

Mini position indicator

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

itemp TMT180 Technical information

Intrinsically safe batch controller Batching Master 110i

Trident and Trident X2 Digital Process and Temperature Panel Meter

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

PHOENIX CONTACT - 12/2007

Electronic Temperature Controller. Instruction Manual Version

Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

JUMO itron 04/08/16/32 Compact microprocessor controllers

Process Indicator PA308

Speed Controller ZSU A01

EY-EM : Remote I/O module, ecolink

Extruder Controls ExtruVision S

Controller. Application Example Climate chambers, dryer, heat threating plants, sterilisers, packing machines, food application, laboratory

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

PROGRAMMABLE DISPLAYING TRANSDUCER / LIMIT SWITCH PMO 2100 / 4100 for temperature, current, voltage, pressure, strain gauge, rotation speed, flow rate

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Compact Universal Controllers

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

LAUREL ELECTRONICS, INC.

SINGLE-CHANNEL PROCESS INDICATOR series 8001

PD765 TRIDENT. Trident Series Process & Temperature Meters.

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Bedienungsanleitung. DAL-101x800S Thermoelement Typ K, B, S, N, E, T, R, L, J

Modular Panel Meter Series EDM 35

User manual DATA RECORDER SRD-99

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Temperature Controller E5C4

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

DPR 100 A/B Analog Scales

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Analog display for resistance current

531K. Process Display Temperature display for Pt100 and Ni100 RTD's. Installation and Operating Manual

EWCH 485 Electronic Pulse Counter

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

UNIVERSAL TEMPERATURE INDICATOR 2 TECHNICAL SPECIFICATIONS

Non-communicating room controllers

PGR-3200 MANUAL INSULATION MONITOR

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Operating Instructions VEGAMET 381

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

Data sheet Video Recorder LINAX A303

Model Number Structure

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Transcription:

A 1200 The Indicator with 3 Limit Contacts Format: Installation depth: 96x48 mm (1/8-DIN) 122 mm Description and Operating Manual ELOTECH Industrieelektronik GmbH Verbindungsstrasse 27 D 40723 HILDEN FON +49 2103 / 255 97 0 FAX +49 2103 / 255 97 29 www.elotech.de Email: info@elotech.de Manual A1200-E Release: 1.02 Elotech GmbH age 1/12

Contents Type code age 2 Connection diagram 3 Technical data 4 Display and keyboard 5 Operating levels, general 6 Configuration level 7 Operating level 10 Error displays 11 Installation instructions 11 lease read this operating manual carefully before starting up. Observe the installation and connecting instructions. Disclaimer of liability: We have checked the contents of the document for conformity with the hardware and software described. Nevertheless, we are unable to preclude the possibility of deviations so that we are unable to assume warranty for full compliance. Type Code A 1200 - x - y - 00 - z 1: ower supply: 230 VAC 2: ower supply: 115 VAC 3: ower supply: 24 VAC 5: ower supply: 24 VDC, +/-25% 1: with 3 limit contacts 2: with 3 limit contacts and process output 0/4-20mA 0: Sensor: t100, Fe-CuNi(L), Type J, NiCr-Ni (K), t10rh-t(s), 0-20mA, 4-20mA Manual A1200-E Release: 1.02 Elotech GmbH age 2/12

Connection diagram ower supply N L DC+ DC- OUT 1 OUT 2 OUT 3 9 8 7 6 5 4 3 2 1 27 26 25 24 23 22 21 20 k1 - + OUT 4: process output; 0/4 20mA t100 / RTD, 2-wire connection: jumper from terminal 24 to terminal 25 TC: 26(+); 25(-) + - 0-20mA: terminal 27(+), 25(-) 4-20mA: terminal 27(+), 25(-) 0-10VDC:terminal 27(+), 25(-); (Option) It is not permitted to connect the grounds of the sensor- and process-output with each other. OUT1 = Relay OUT2 = Relay OUT3 = Relay OUT4 = Switches on setpoint S1 Switches on setpoint S2 Switches on setpoint S3 Analogue process value output 0/4...20mA. Function of contact k1: k1: open = Adjustment lock only via "Software Code" k1: closed = Adjustment locked (according to the chosen software code) Manual A1200-E Release: 1.02 Elotech GmbH age 3/12

Technical Data Input Thermocouple: Input t100 / RTD: Input 0/4...20mA: Built-in internal compensation point and protection against sensor breakage and incorrect polarity. Re-calibration not required for a line resistance of up to 50 Ohms. Calibration accuracy: < 0,25% 2 or 3-wire connection possible. Built-in protection against sensor breakage and short circuit. Max. permissible line resistance by 3-wire connection: 80 Ohms Sensor current: < 0,5 ma Calibration accuracy: < 0,2 % Load max. 10 Ohm. Linear error: < 0,2 % Influence of the ambient temperature: < 0,01 % / K Setpoint selection (k1): Ext. potential-free contact, switching voltage appr. 24 V DC, max. 1 ma. Selection between S1 (main setpoint) and S2. Control outputs: - Relay (UR appr.), max. 250 VAC, max. 3 A (cos-phi = 1) rocess output: -OUT 4: 7-Segment-Display: Data protection: CE-Mark ower supply: Connections: Equivalent to the choosen range. 0/4...20 ma Load max. 500 Ohms Linearity: < 1,5 % Delay time: app. 2 secs. rocess: 10 mm red, Set: 10 mm red EAROM Tested according to 2004/108/EC Electr. safety EN 61010-1 EMC for industrial areas EN 61326-1 Standard: 230 V AC. ± 10 %, 48...62 Hz. Others possible. See Type Code. Appr. 5VA. Screw terminals (UR appr.). rotection mode I 20 (DIN 40050), Insulation class C. ermissible operating conditions: Operating temperature: 0...50 C / 32...122 F Storage temperature: -30...70 C / -22...158 F Climate class: KWF DIN 40040; Equivalent to annual average max. 75 % rel. humidity. No condensation. Casing: Format: 96 x 48 mm (DIN 43700). Installation depth 122 mm anel cutout: 92 +0,8 mm x 45 +0,6 mm Material: Noryl, self-extinguishing, non-drip, UL 94-V1 rotection mode: I 20 (DIN 40050), I 50 front side Weight: app. 380g Subject to technical improvments! Manual A1200-E Release: 1.02 Elotech GmbH age 4/12

Display and Keyboard Display ROCESS Display 2 : rocess Value : While standard operation: Selected physical unit or no display LED 1: Output OUT1 LED 2: Output OUT2 LED 3: Output OUT3 arameter key Adjustment of chosen parameter (e.g. setpoint) to higher or lower values. E.g. setpoin adjustment. Short operation: single-step adjustment Longer operation: quick-scanning When the parameter adjustments have been altered but not entered with the E-key, the display will flash bright/dark. E Confirmation and storage of the pre-selected values The display will shortly show a light chain as a control of this function. To return to the process-display: press E appr. 2 sec.. Sets the parameter back to the originally stored value. Any alterations made to the parameters, that are not confirmed (E-key) within 30 seconds, will not be accepted and the parameter will return to the process value display. Manual A1200-E Release: 1.02 Elotech GmbH age 5/12

Operating Levels The operation of the controller is divided into 2 levels. Two seconds after switching on the unit, the controller will automatically be in the operating level. press and appr. 3 sec. ower: Operating Configuration on Level Level E rocess Value SEn S1 S3 OFSt Back into operating level: - ress E appr. 3 sec. or - after 30sec. automatically Operating level rocess- and setpoint value will be displayed simultaneously. Within the operating level the setpoints and the alarm value can be adjusted by pressing the " " / " " - keys. Every adjustment has to be quit by pressing the E - key. All parameters within the operating level can, in succession, be displayed by pressing the - key and adjusted by pressing the " " / " " - keys. Configuration level Enter this level by pressing the and E -key appr. 3 sec. simultaneously. In the configuration level the sensor type, the sensor range, the switching behaviour of the relay outputs OUT1 OUT3 can be pre-selected. This primary information has to be entered before taking the instrument into operation. The display of each single parameter within the configuration level, and their adjustment, are made in the same way as within the operating level. After either pressing the E - key for approx. 3 second, or waiting for a period of approx. 30 seconds, the unit will automatically return to the operating level (display of process value). Manual A1200-E Release: 1.02 Elotech GmbH age 6/12

Configuration Level ress and E -key appr. 3sec.. Display arameter Display "rocess" 2 Sen Sensor selection 1 C t 100, -50,0...100,0 C 1 F t 100, -58,0...212,0 F 2 C t 100, -100...200 C 2 F t 100, -148...392 F 4 C t 100, 0...400 C (ex works) 4 F t 100, 32...752 F 8 C t 100, 0...800 C 8 F t 100, 32...1472 F L4 C T/C Fe-CuNi (L), 0...400 C L4 F T/C Fe-CuNi (L), 32...752 F L8 C T/C Fe-CuNi (L), 0...800 C L8 F T/C Fe-CuNi (L), 32...1472 F J8 C T/C Fe-CuNi (J), 0...800 C J8 F T/C Fe-CuNi (J), 32...1472 F n1 C T/C NiCr-Ni (K), 0...1200 C n1 F T/C NiCr-Ni (K), 32...2192 F S1 C T/C t10rh-t (S), 0...1600 C S1 F T/C t10rh-t (S), 32...2912 F 0-20 Current-Input 0...20mA 4-20 Current-Input 4...20mA If the Sensor selection is changed, the following parameters will be reset (setting in brackets) and need to be re-adjusted: All Setpoints (set to OFF); all switching hysteresis values (Sh); process offset value (OFF) The following parameters are only valid for standard signal inputs (0...20mA, 4...20mA). The difference between the bottom end of the display range and the top end must amount to a minimum of 100 units and a maximum of 2000 units. By adjustment of one of the above parameters, the other in this case will automatically follow. ra.s decimal points 0; 1; 2 (ex works: 1) ra.hi display range top end ra.lo... 9999 (ex works: 100,0) ra.lo display range bottom end -1999... ra.hi (ex works: 0,0) Out4 rocess value output OFF no process value output selected r. 0 0...20mA process value output r. 4 4...20mA process value output Option: process value output Sc.Hi higher range limitation valid for analogue process value output, if Out4 = r.0 or r.4 (20mA value) Adjustment range: Sc.Lo... top range (ex works: 400) Sc.Lo lower range limitation valid for analogue process value output, if Out4 = r.0 or r.4 (0/4mA value) Adjustment range: bottom range... Sc.Hi (ex works: 0) The difference between Sc.Lo and Sc.Hi must be a minimum of 25% of the sensor range. unit selectable physical unit shown in the lower display 2 ( e.g. : C, F, bar, volt, A, OHM, rot, rm, MA, %, SEC, HZ... ) Manual A1200-E Release: 1.02 Elotech GmbH age 7/12

Display arameter Display "rocess" 2 Configuration of the switching behaviour of the relais OUT1, OUT2, OUT3 corresponding to the setpoints S1, S2, S3. The relais are switching like limit contacts. The limit contacts are adjusted and displayed as absolut setpoint values. Switching behaviour: Configuration: limit value off on 2 on off 5 process on: Relay "activated" off: Relay "not active" lease note: In case of sensor error the alarms will react in the same way as range override. C.S1 Configuration setpoint S1 2 Switching behaviour of relay 1: off - on 5 Switching behaviour of relay 1: on - off C.S2 Configuration setpoint S2 2 Switching behaviour of relay 2: off - on 5 Switching behaviour of relay 2: on - off C.S3 Configuration setpoint S3 2 Switching behaviour of relay 3: off - on 5 Switching behaviour of relay 3: on - off Manual A1200-E Release: 1.02 Elotech GmbH age 8/12

Display arameter Display "rocess" 2 1 Sh switch-point hystereses OUT 1 Adjustment range: 10% of the selected measuring range. With or without decimal point, depending to the selected range. Sh = 1,0 Sh = 1,0 on on off off -1,0-1,0 Switching point S1, S2 or S3 Switching point S1, S2 or S3 2 Sh switch-point hystereses OUT 2 3 Sh switch-point hystereses OUT 3 Adjustment range: 10% of the selected measuring range. With or without decimal point, depending to the selected range. Adjustment range: 10% of the selected measuring range. With or without decimal point, depending to the selected range. OFSt process value offset -999... OFF...1000 K (ex works: OFF) -99,9... OFF... 100,0 K -9,99... OFF... 10,00 K This parameter serves to correct the input signal, e.g. for: - the correction of a gradient between the measuring point and the sensor tip, - the line resistance balancing of 2-line RTD (t100) sensors and - correction of the control devition when using - or D-action. If for example the offset value is set to +5 C, th en the real temperature measured by the sensor (when process is balanced) is 5 C less than the setpoint and the displayed process value. LOC Adjustment lock OFF no adjustment lock (ex works) C parameter and configuration levels locked ALL all parameters locked All parameters that have been locked with LOC can be selected and read, but not altered. This adjustment cannot be changed if the external contact K2 is closed. 1200 EL.xx Control number No function. End of configuration level Manual A1200-E Release: 1.02 Elotech GmbH age 9/12

Operating Level Display arameter Display "rocess" 2 rocess (process) and physical unit (display 2) S1 Setpoint 1 Limit contact value OUT1 (ex works: OFF) OFF = OUT1 not active S2 Setpoint 2 Limit contact value OUT2 (ex works: OFF) OFF = OUT2 not active S3 Setpoint 3 Limit contact value OUT3 (ex works: OFF) OFF = OUT3 not active The range of adjustment is dependant on the sensor range. Manual A1200-E Release: 1.02 Elotech GmbH age 10/12

Error displays Display Cause ossible remedy ra.lo Lower range has been reached Reduce limit, if need be ra.hi Upper range limit has been reached Increase limit, if need be LOC arameter has been locked Unlock, if need be Er.Hi Top range end has been exceeded, Check sensor and cable sensor defect Er.Lo Bottom range end has been exceeded, Check sensor and cable sensor defect Er.SY System error Extinguish error signal by pressing the E -key. Check all parameters. If the error signal continues please send the instrument back for examination. Installation Instructions Make certain that the devices described here are used only for the intended purpose. They are intended for installation in control panels. The controller must be installed so that it is protected against impermissible humidity and severe contamination. In addition, make sure that the permitted ambient temperature is not exceeded. The electrical connections must be made according to the relevant locally applicable regulations. If using a thermocouple sensor, the compensation cables must be laid directly to the controller terminals. Transducers must be connected only in compliance with the programmed range. Transducer cables and signal lines (e.g. logic or linear voltage outputs) must be laid physically separated from control lines and mains voltage supply cables (power cables). To keep the CE-conformity it is nessesary, to use for sensor- and low voltage signal lines shielded cabels. Spatial separation between controller and inductive loads is recommended. Interference from contactor coils must be suppressed by connecting adapted RC-combinations parallel to the coils. Control circuits (e.g. for contactors) should not be connected to the mains power supply terminals of the controller. IMORTANT: Before operation, the unit must be configurated for its intended purpose (e.g. sensor type and range, switching point/setpoint adjustment etc.). lease see Configuration Level. Manual A1200-E Release: 1.02 Elotech GmbH age 11/12

Manual A1200-E Release: 1.02 Elotech GmbH age 12/12