Bruker NMR Topspin Manual

Similar documents
DCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015

Vanderbilt Small Molecule NMR Center

Routine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer

DCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751)

Quick Guide to Topspin

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin.

NMR Data Acquisition and Processing Procedure

DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400

NMR Spectrometer Crib-Sheet

Running Multiple Experiments on the Same Sample Automatically. (multizg, spooler/queue, iconnmr)

Welcome to the NMR Center

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR

Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12

TopSpin 1.3 patch level 10. DPX 200, DPX 300 and DRX 500. Windows XP

ONE DIMENSIONAL NMR SPECTROSCOPY. DPX 200 and DPX 300

Bruker Topspin NMR Training Manual

UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

Basic Procedure 1D NMR Data Collection

Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 DISCLAIMER

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400

On Artemis and Cronus, make sure you are adjusting the db scale and not the watts

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500

NMR Spectroscopy with VnmrJ. University of Toronto, Department of Chemistry

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Guide for Basic 1D NMR Spectroscopy

Bruker Avance 400 MHz Instructions

NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation

North Carolina State University Department of Chemistry Varian NMR Training Manual

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

1D and 2D Experiments Step-by-Step Tutorial

NMR Training VNMRJ 4.2A/VNMRS 400

Acquiring Data in VnmrJ 4.2A

Processing data with Bruker TopSpin

NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington XWINNMR 3.5 TRAINING NOTES. 08/8/2005 rajan paranji

c. Saturday and Sunday: 10 minute time blocks and unlimited time.

PINMRF. Bruker Avance / AV NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy

Agilent VnmrJ 3.2. Quick Start Guide

Varian Solution NMR Procedure

Bruker AVANCE III HD 400 MHz Spectrometer Operation

Delta V5 operation. Widetron Technologies Corp. Wu, Chung Ying. Progress through Synergy

NMR Users Guide Organic Chemistry Laboratory

VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS

Troubleshooting Acquisition Related Problems

NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington TOPSPIN 2.1 TRAINING NOTES

Varian Solution NMR Automation Procedure (VNMRS Machines running VNMRJ 4.2 under Red Hat Enterprise 5.1)

CONTENTS 1D EXPERIMENTS D EXPERIMENTS APPENDIXES... 83

2 Dimensional NMR User s Brief Guide

TOCSY 15. Goto. Introduction Pulse Sequence Diagram AVANCE User s Guide Bruker 167

Fitting NMR peaks for N,N DMA

General Information for Automated Inova 500 MHz NMR (Indy)

PROCESSING 2D SPECTRA USING VNMRJ JB Stothers NMR Facility Materials Science Addition 0216 Department of Chemistry Western University

Varian Solution NMR Automation Procedure

Intermediate Microsoft Word 2010

KJM Proton T1 Spectra on the AVI-600 and AVII-600. Version 1.0

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

EQNMR Facility Rules of Use

MNova Version Installation Instructions.

See XwinNMR Acquisition Manual, Sections 1.4, 1.5 (see list of acquistion parameter descriptions starting , pg. A-39), 1.6

KJM NMR processing everywhere with Windows Remote Desktop and TopSpin 3.5 at nmr-server.uio.no. Windows Server Version 1.

Bruker OminiFlex MALDI-TOF Mass Spectrometer Operation Quick Start

TopSpin is the successor to a program called XWinNMR, which appeared in the mid- 90s (I believe) and was used to run Bruker spectrometers until it

USER MANUAL FOR BASIC NMR ACQUISITION AND OPERATION OF BRUKER DPX400 and AV400 SPECTROMETERS

67 Series Spectrophotometer PC Software

Creating Postcards in Microsoft Publisher

Windows XP. A Quick Tour of Windows XP Features

ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW

Instructions for 1 H-, 13 C-, 19 F-, and 31 P-Spectra on the Varian Mercury-Vx-300

Open Office Calc (Spreadsheet) Tutorial

1. Move your mouse to the location you wish text to appear in the document. 2. Click the mouse. The insertion point appears.

MALDI Software Users Guide (simplified version)

Clip Art and Graphics. Inserting Clip Art. Inserting Other Graphics. Creating Your Own Shapes. Formatting the Shape

DDX-R Quick Start Guide

Walkup NMR. Varian NMR Spectrometer Systems With VNMR 6.1C Software. Pub. No , Rev. A0800

EXCEL 2007 TIP SHEET. Dialog Box Launcher these allow you to access additional features associated with a specific Group of buttons within a Ribbon.

MestReC Cheat Sheet. by Monika Ivancic, July 1 st 2005

DataStudio Starter Manual

Open Access Manual for Superusers

PINMRF. Varian 300 MHz NMR Spectrometers Training Guide for Basic 1D NMR Spectroscopy

Create a unit using United Streaming and PowerPoint. Materials: Microsoft PowerPoint, Internet access, United Streaming account

ENVI Tutorial: Introduction to ENVI

T 1 Relaxation Measurement: The Inversion-Recovery Experiment (Using IconNMR) Revised

File Management Tutorial

Processing With Topspin

= 3 + (5*4) + (1/2)*(4/2)^2.

FOCUS. Image Based Automatic Shimming Using B 0 Gradients. Installation and Users Guide Version 0.9

Basic 1D Processing. Opening Saved Data. Start the VnmrJ software. Click File > Open.

FaxFinder Fax Servers

VnmrJ Walkup. Varian, Inc. Inova and MercuryPlus NMR Systems With VnmrJ 2.2D Software Pub. No , Rev. A 0808

Introduction to Windows

TOPSPINPLOT(XWINPLOT)

IconNMR Operating Procedures

TopPoint User's Guide

Easy Match QC Lesson 9. Setting Up a Print Job

Lab Assignment #1: Introduction to Creo ME 170

Installing TopSpin 4

The Trackball First make sure your hand is in the correct position on the trackball.

Document Imaging User Guide

Tricking it Out: Tricks to personalize and customize your graphs.

Transcription:

Bruker NMR Topspin Manual Topspin is an icon driven software package. This means that instead of reading words and typing commands in the software most of the things will be carried out by clicking icons on the screen. If you have used Bruker software where you typed in commands these will still work. A list of the icons and their functions are attached at the end of these instructions. If you are not sure what an icon does pass the mouse over an icon and you will be given a written hint. Starting the Bruker NMR software After you log into the computer click on the on the Topspin icon or click on the file button on the top menu bar, go down to BRUKER and click on Topspin Setting up the Experiment Before you start collecting any data it is imperative that you create a new file to contain your data. Start by clicking file and then new (you could also type new or edc on the command line). A window will open into which you should type a new FILENAME and enter an EXPNO. If you wish to change the type of experiment you can do this now by changing the selections in the window ie. solvent and experiment type from the lists supplied. If you wish to make an exact copy of the current parameters click the button to use the current parameters or if the button is not present go to the top of the experiments list and choose use current parameters. This will create a file containing exactly the same parameters as the experiment that you were in when you started to create the new file. Click save when you are finished. When the new experiment opens check the parameters by clicking on the Acqupar tab along the top of the window. Before you continue you should type getprosol or click the icon at the top of this window that looks like a partially filled NMR tube. This updates the probe head parameters. You should also check the nucleus to be sure that the instrument is going to collect the type of experiment that you want. If these are the proper parameters than you can continue, however, if you wish to change the type of experiment you must call up a new parameter set. This can be done by typing rpar. A list of parameter sets will then appear. There are two lists that can be chosen which can be seen by choosing source in the upper right hand corner. The one that ends in par contains all of the parameter sets that come with the instrument. The one that ends in user contains only the ones that have been modified to work on the current system. After choosing the correct directory click on the experiment that you want to carry out. Click copy all. A short cut to do this is to type rpar, the parameter set name (if you know what it is) followed by all ie. rpar proton all. The parameters that were picked can now be modified if necessary. Parameters can be entered in three different ways. The easiest way is to type in the parameter acronym, a space and the new value ie. ns 16. If you wish to change a parameter but, wish to see what the current value is before you change it just type the parameter pneumonic and a return. A box will then open containing the value for that parameter. You can then change the value or leave it unchanged. If

you do not know the parameters pneumonic you can go to the specific parameter tab at the top of the spectral window (AcquPar, acquisitions; ProcPar, processing) and change it there. Putting your sample in the instrument For the AVIII-400 Next to the keyboard on the desk is a key pad that will be used for many of the manipulations that you will be doing. To insert your sample press the upper left hand gray button that says lift. When the standard sample is ejected from the instrument replace it with your sample that has been set to the correct depth with the depth gauge and then press the same button again to insert your sample. For all other instruments To eject or insert your sample type ej or ij respectively. You could also turn on the bsms display by clicking on the bsms icon on the top menu or by typing bsmsdisp. This will open the bsms display window which will give you access to many of the functions necessary to manipulate your sample including insertion and ejection of your sample, spinning, locking and shimming. Clicking on the lift button will eject your sample. Clicking on it again will insert it. Check spin icon at the bottom of the wind to see if your sample is spinning. Type ro on or ro off to start or stop the rotation (spinning) respectively. Auto-Sampler: If you put your sample under the lift mechanism you can type ij insert or ej for eject. If you put the sample in a different position type sx xx where xx is the location of the sample. Locking and shimming: Open the lock display window by clicking on the lock icon or by typing lockdisp. To lock the sample type lock which will bring up a list of the known solvents. You can then click on the appropriate solvent name. If you know what the solvent name is in the software you can just type lock followed by the solvent name and the instrument will then automatically lock the solvent. The success of this procedure can be determined by looking to see if the line in the lock window is now about half way up the screen. If it is not you may want to bring up a good set of stored shims. This can be done by typing rsh which will cause a list of stored shims to appear. Click on a shim set for the specific probe that is in the instrument and has the most recent date and then just repeat the locking procedure. Gradient shimming All of the Bruker solutions instruments have automatic gradient shimming. This can be started by typing topshim or clicking on the shim button that you may have on the menu bar. Tuning the probe:

Automatic Probe (ATM) Tuning This can be done is two ways, totally automatic or manually. Automatic probe tuning is started by typing atma. This will take about at one minute or longer and will give satisfactory results. If you want to tune the probe yourself go into the manual mode by typing atmm. A window will open as shown below. Click the appropriate buttons to put the dip at the center and as close to the bottom at possible. When you are finished click file and exit. Collecting and Processing the 1D Data (for all systems) Before you can collect the data you must set the receiver gain for an optimum value. This is done by typing rga. When this is finished you can start the data collection by typing zg. When the data has been collected it must be transformed it by typing efp. This adds a line broadening factor, Fourier transforms the data and then adds some phase parameters. You should then see your spectrum on the screen. The spectrum can be manipulated with the icons on the top panel.

If you wish to see the spectrum before the experiment is finish you can type tr to transfer the data from the console computer to the desktop for Fourier transform. If you wish to stop the experiment you can type stop. If you do type stop before your experiment is completed than all data remaining in the console computer will be discard causing you to lose all, or any of your remaining data. If you wish to stop the experiment but keep the data up to that point you must type tr first to transfer the data before typing stop, or you can type halt which will complete the current scan, transfer the data and then do a stop. Phasing Automatic phasing is done by typing apk. If the phase is still bad click the phase icon on the top menu which will open a menu bar. Put the mouse on 0 in the menu bar, hold down the left mouse button and move the mouse up and down to fix the phase of the tallest peak in the spectrum. When this peak is correctly phased, move the mouse to the 1 and adjust the phase of the other peaks. When you are finished click the save and return icon. Baseline Correction Sometimes the baseline is not flat or is not located at the zero position. This can affect the integration. If you wish to correct this problem type absn to automatically correct it. Spectral Manipulations Expansions: You can expand the spectrum on the screen by moving the cursor to where you wish to start your expansion then hold the left mouse button. Drag the cursor across the screen and let go at the point where you want to end the expansion. For more information on the icons see the attached sheets. Integration:

Click the integration icon on the top menu bar to open a new integration menu. Click the integration icon (just to the right of the yellow icon) so that it turns green. Pick the areas that you want to integrate by holding down the left mouse button and dragging the cursor across the area of interest and letting go of the mouse button. When you are finished click the save and return icon. Peak Picking: To pick the peak locations click the proper icon on the top menu bar. This will open a peak picking menu bar. Using the left mouse button draw a box over the peaks that you want to pick being sure that the bottom of the box stays above the baseline. The bottom of the box will be the minimum intensity of the picked peaks and the top of the box will be the maximum intensity (only peaks the fit within the box will be picked). Click the save and return icon when you are finished with this process. Plotting the spectrum Once you are satisfied with your data it can be printed. This instrument uses a special graphics program for this purpose. The best way to start this program is to type plot (AMX-400) or clicking the plot tab above the spectrum (all other Bruker instruments). This will start the program with your spectrum in the middle. There are four areas on the spectrum 1) spectrum, 2) parameters, 3) Bruker logo and 4) text. You can choose the portion of the spectrum that you want to work on by putting the mouse in that area and pressing the right mouse button. A box will appear around the area with green squares on the border. Manipulating the spectrum When you highlight a specific area a box will appear on the left side of the page. You can use the information in this box to manipulate your data. Each area will have a different set of things that you can do to manipulate what is on the printout. Print the spectrum when you are finished When you are finished be sure to replace the standard sample in the magnet.

Saving Data to Your Prism Account from the NMR s Anytime that you wish to transfer your data you must be in a terminal window. This can be opened on the Bruker instruments by clicking the right mouse button in the window. A menu will appear. Click terminal. A terminal window will open. You now need to be in the directory that contains your data.to get there type: For AVIII-400 (c3po) cd /opt/topspin3.0/data/your user name/nmr For AVIIIHD-500 (chewie) cd /opt/topspin3.2/data/your user name/nmr For all other Bruker instrument cd /opt/topspin3.5pl5/data/your user name/nmr You can check if your data is there by typing ls which will list the files in the current directory. To transfer the data type the command below: scp -r < filename><your gatech email address>@scp.prism.gatech.edu: The filename is the name of the data file that is in your directory. Be sure to type in the name exactly as it appears in your directory. The email address is your personal Georgia Tech email address on the Georgia Tech prism computer. The : (colon) at the end of the line is very important so do not forget to put it in. You will then be asked to enter your password. This is your email password and not the NMR password. While that data is being transferred you will see some information going across the screen indicating the transfer. If you do not see these lines it might mean that you forgot to put the : (colon) after the line. After the data is transferred you can remove the data from the hard disk or you can leave it until you are sure you have properly transferred your data. If you wish to remove your data you can type the following on your data directory: rm -r filename If you want to remove all of your NMR files then use the following command which contains the wildcard character * which means any characters of any length. rm -r abc* The * can be used to remove any specific group of files. This will remove all files that begin with abc.