Auto-Transfer Rack Power Distribution Unit

Similar documents
Instruction Manual. Rack PDU XP Series. geistglobal.com

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Instruction Manual Rack In-Line Power Measurement Unit. L Series

Instruction Manual Rack Power Distribution Unit. J, VHV Series

Instruction Manual. Rack PDU BRE and VRTE Series. geistglobal.com

Instruction Manual. Rack PDU BR, SP, SVR, VRT, NSV, and VSS Series. geistglobal.com

LVN5200A-R2, rev. 1, Hardware Installation Guide

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

SAFETY WARNINGS AND GUIDELINES

HDMI and USB KVM Extender

Zebra RW 420 Mobile Battery Eliminator Kits

elise 3 embedded linux server including safety instructions

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

2 Mesa Ethernet Dock User s Manual

3M RFID Tracking Pad Model 770

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

Unity 100-watt Bridgeable Power Amp

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

SB Channel Soundbar with Built-in Subwoofer

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

ShoreTel IP Phone 655. Quick Install Guide & Warranty

Safety and Radio-Frequency Interference

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Switched Rack Power Distribution Unit

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MONOPRICE. Blackbird 4x4 HDMI Matrix/Extender with 4 Receivers. User's Manual P/N 21905

Instruction Manual. Rack PDU J, VHV, and MJ Series. geistglobal.com

Installation Guide DRAFTMF4100

MONOPRICE. Blackbird HDMI Bi-Directional Switch. User's Manual P/N 24280

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

KP7 Keypad Quick Install Guide

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Solarflare X2522 network adapter Quick Start Guide

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

WIRELESS BLUETOOTH BOOMBOX

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

User Manual. Per Port Monitoring Models

Plug-in wireless speaker

USER GUIDE. Laptop Charger NS-PWLC591/NS-PWLC591-C. Before using your new product, please read these instructions to prevent any damage.

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

OVERVIEW. *Press and release. *Hold for 5 seconds. *Charging port

IFS NS P/4S GE-DSSG-244 GE-DSSG-244-POE Quick Installation Guide

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

PM Series Power Meter

IPS-800/1600-D20 Series

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

WTI Part No Rev. H. VMR Series. Managed Power Controllers. NPS Series. Network Power Switches. User's Guide

Emotiv Insight User Manual. Revision 1.0 June 2015 Emotiv Inc, 2015

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CSM200 Expansion Tray

SANnet II Family Safety, Regulatory, and Compliance Manual

Handset Charging Rack OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Ultra Slim Multimedia Keyboard (KB3100MF)

PD-6506, PD & PD-6524

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Fail-Safe Power Redundancy

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

iconverter 2-Module Power Chassis

Installation Job Aid for VSP 4850GTS

MONOPRICE. Blackbird 4K HDMI 1x8 Splitter/Extender. User's Manual P/N 18787

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

Media Conversion Rack-Mount Chassis AT-MCR12. Installation Guide Rev. A

Installation Job Aid for VSP 4450GTX-HT- PWR+

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

IP7 -SS40. IP Paging Amplifier. Reference Manual

Controller Specifications

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

Installation Job Aid for Ethernet Routing Switch 3600 Series

MODEL: VSP735. Compliance. About this Guide. Parts Checklist. FCC part 15. Industry Canada

USER MANUAL. Elo Touch Solutions 2D Barcode Scanner Peripheral

MONOPRICE. Blackbird 4K 2x7 HDBaseT Splitter Kit. User's Manual P/N 24178

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

G5 PDU Installation Guide

Stage Rack Installation Guide

AT-GS950/16 AT-GS950/24

High Power over Ethernet Midspans PD Port Model PD Port Model

Installation Job Aid for Ethernet Routing Switch 5900 Series

NCH-1000 (Multiple Breaker Types) Installation Instructions

Instruction Manual Environmental Monitoring Unit. GRSMINI-P, GRSMICRO, GRSMINI163 Firmware Version 3

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

HD40H(X) Performance Series Camera. User Guide

DATALOCKER H100 ENCRYPTED HARD DRIVE. User Guide

Transcription:

Auto-Transfer Rack Power Distribution Unit geistglobal.com

2 Auto-Transfer Rack Power Distribution Unit Table of Contents Part I Specifications 3 1 Overview... 3 2 Environmental... 3 Tem perature... 3 Hum idity... 3 Elevation... 3 3 Electrical... 3 4 Receptacle... Ratings 3 5 EMC Verification... 3 Part II Installation 5 1 Instructions... 5 2 Guidelines... 5 Part III Mounting 6 Part IV Optional Local Monitoring 7 1 Power... Meter 7 2 Current... Meter Part V Service/Tech Support 1 Service... and Maintenance 2 More Technical... Support Part VI Table of Figures 9 Part VII Revision History 9

Specifications 1 Specifications 1.1 Overview 3 The AT Series Auto-Transfer Power Distribution Units (PDUs) provide automatic transfer switching from primary (Source A) to secondary (Source B) in the event of primary source failure. The PDU automatically transfers back to the primary source when it becomes available. Front mounted LED s indicate availability of power at Source A and Source B. AT Series Auto-Transfer PDUs can optionally be configured with a Geist Current Meter that provides local monitoring and display of each output circuit current. 1.2 Environmental 1.2.1 Temperature Operating: Storage: 10 C (50 F) min -25 C (-13 F) min 45 C (113 F) max 65 C (149 F) max 1.2.2 Humidity Operating: Storage: 5% min 5% min 95% max 95% max (non-condensing) (non-condensing) 1.2.3 Elevation Operating: Storage: 1.3 0 m (0 ft) min 0 m (0 ft) min 2000 m (6561 ft) max 15240 m (50000 ft) max Electrical See nameplate for unit ratings. 1.4 Receptacle Ratings NEMA 5-15R or L5-15R NEMA 5-20R or L5-20R NEMA 6-20R or L6-20R IEC-320 C13 IEC-320 C19 1.5 125 Volts, 15 Amp 125 Volts, 20 Amp 250 Volts, 20 Amp 125/250 Volt, 15 Amp (per Receptacle Bank) 125/250 Volt, 20 Amp EMC Verification This Class A device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and

4 Auto-Transfer Rack Power Distribution Unit (2) this device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment. FCC and Canadian ICES-003 requirements for units with Current Monitoring Meter: The ferrite core shipped with the unit must be placed around the Ethernet cable close to the PDU.

Specifications 2 Installation 2.1 Instructions 5 1. Using appropriate hardware, mount PDU to rack (see Mounting section for additional instructions). 2. Plug PDU into de-energized, Phase Synchronized branch circuit receptacles. 3. Connect devices into PDU s output receptacles. It is recommended that the devices are turned off until all devices are connected to PDU 4. Turn on branch circuit for Source A to energize PDU. 5. Turn on branch circuit for Source B. 6. Power on devices. Sequential power up is recommended to avoid high inrush current. 2.2 Guidelines Warning: Source power must be Phase Synchronized, high voltage potential may result in relay failure when sources are not Phase Synchronized. Some loads may pull high inrush current when switching power sources. Do not overload ATS to prevent relay failure and tripping branch circuit protection. If the PDU is installed in a cabinet the ambient temperature of the rack should be no greater than 45 C. Install the PDU such that the amount of airflow required for safe operation of equipment is not compromised. Mount the PDU so that a hazardous condition is not achieved due to uneven mechanical loading. Follow nameplate ratings when connecting equipment to the branch circuit. Take into consideration the effect that overloading of the circuits might have on overcurrent protection and supply wiring. The PDU relies on the building installation for protection from over-current conditions. A certified overcurrent protection device is required in the building installation. The overcurrent protection device should be sized according to the PDU s nameplate ratings and local/national electrical codes. Reliable earthing of rack-mount equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit. The PDU must be connected to an earthed socket-outlet. The PDU is intended for Restricted Access Locations only and only qualified service personnel should install and access the PDU. For pluggable equipment, install the PDU so that the input plug or appliance coupler may be disconnected for service. Sequential power-up of devices powered by the PDU is recommended to avoid high inrush current. Caution: Disconnect all power cords before servicing. The PDU is intended for use with TN or TT power supply systems

6 3 Auto-Transfer Rack Power Distribution Unit Mounting Flush Mount Brackets (FM) Using flush mount brackets, attach PDU to rack as shown Adjustable Mount Brackets (AM) Using adjustable mount brackets, attach PDU to rack as shown

Mounting 7 23" Conversion Mounting Brackets (23-RM) Using conversion mounting brackets, attach 19 PDU to 23 rack as shown 4 Optional Local Monitoring 4.1 Power Meter The Geist PM-1 power meter is a low-power, high accuracy meter capable of measuring true RMS Current, Voltage, Power, and Power Factor. These values are individually shown on an easy to read, 4-digit LED Display, which continuously scrolls through the four different measured values. Each one of these displayed parameters is defined below. The Power Meter will automatically begin cycling through the displayed values when the PDU is connected to AC Mains power. Current: PDU output current draw measured in true RMS Amps Voltage: PDU output voltage measured in true RMS Voltage Power: PDU output power measured in Watts referred to as real or active power Power Factor: Ration of real PDU output power to apparent PDU output power

Auto-Transfer Rack Power Distribution Unit Power Meter Display 4.2 Current Meter The Geist CM-1 current meter is a low-power, high accuracy meter capable of measuring true RMS Current. The value of current is continuously shown on an easy to read, 4-digit LED Display. The Current Meter will automatically begin to display value of output current when the PDU is connected to AC Mains power. Current Meter Display 5 Service/Tech Support 5.1 Service and Maintenance No service or maintenance is required. Do not attempt to open the PDU or you may void the warranty. No serviceable parts inside. It is recommended that power be removed from the unit before installing or removing any equipment. 5.2 More Technical Support Email: support@geistglobal.com Or contact your distributor. Americas 1 630 4445

Service/Tech Support 9 Europe and Middle East From within the UK 045 026 353 From abroad +44 45 026 353 Asia 6 English +1 630 4445 (US number) Chinese +6 755 663 9505 Table of Figures Flush Mount Brackets (FM)... 6 Adjustable Mount Brackets (AM)... 6 23" Conversion Mounting Brackets (23-RM)... 7 Power Meter Display... Current Meter Display... 7 Revision History Revision Date Notes Approved By 1.0 2/17/2011 Original Published Version BP 1.1 6/22/2012 Changed Logo and web address SR 2.0 7/25/2014 Changed EM40 Display Page and company s name QN 3.0 1/31/2017 Removed EM and PM3 meter information SC