USB/PPI Programming Cable Driver Procedure. Setting Guideline

Similar documents
USB/PPI+ Programming Cable Driver Procedure. Setting Guideline

Windows 8 / 7 CONTENTS. USB to RS-422 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

Windows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

USER S MANUAL. MULTiCOM-4. USB to #4 RS-232 Serial COM Multiport. Doc No: MULTiCOM-4-UM-001

INTRODUCTION...1. Under Windows 98SE... 2 Under Windows ME... 6 Under Windows Under Windows XP...10

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

3.1 I-7560 Pin Assignment and Specifications: Introduction

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

RS-422/485 PCIe Card

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

Product Manual. USB 2.0 to Serial High- Speed RS-232 Industrial Adapter. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-COM-M

TC-UR24. USB to Serial port Adapter

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

USB to RS-422 / 485. US USB To Serial Operation Manual

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

USB to Serial Converter manual

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

Commercial Grade USB to RS-422/485 Adapter User's Manual

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

Quick Installation Guide TU-S9

USB485 USB to RS485 Converter Card

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

Introduction. 1 available USB type A (downstream) port. Windows 98, Windows ME, Windows 2000, Windows XP,

FX-USB-AW/FX3U-USB-BD. USER'S MANUAL USB Driver Installation Edition

1. Introduction. 2. Installation INSTALLATION INSTRUCTIONS: MCD USB MODULE

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI.

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

Dot Matrix Indicator Programming

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

Revision History Revision Date Version Pages Description

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

Hardware : USB-Parallel Printer Cable Software : Driver software. User s Manual

MeshConnect ISP / WNA (ZIC2410USB-WNA-1) User Guide

TRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual

Serial 2-Port ExpressCard

Industrially Isolated USB to Serial Adapter User s Manual

USR-TCP Hard version: V2.0 File version: V

PCI Express 16-Port Serial I/O Cards

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

USER S MANUAL USB TO Serial Adapter

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M

User s Manual Printed Sep Rev 1.2

PIN Pad: Installation

FREQUENCY DRIVES ADJUSTABLE SERIES 9000 AF DRIVES. SVLoad Application. Loading Application and Option Software. Instruction Sheet

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

Product Manual. USB to RS232 TTL CMOS Adapter Cable with Terminal Block. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-232TTLMOS

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications

USER MANUAL for USB Data Link

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

Registering Your D1 with the System (Windows 2000)

PC Adapter CN USER MANUAL

Software Manual Virtual COM for Ethernet Driver / Configuration Tool

USB TO RS232 * 2 cable Installation & User s Manual

6 foot USB to RS-232 Serial Adapter DB-9 Male, FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MM

AR-B9014/AR-B9016/ AR-B9018 Manual Version 1.0

DirectPort-USB USB-Serial Converters User Guide

ECOTRONS CAN USB CAN Bus. Support Windows XP, Windows 7 and Windows 10. CAN baud rate can be set anywhere between 5 Kbps and 1 Mbps

INTRODUCTION...1. I. Install the driver of USB TO IRDA Adapter... 2 Under Windows 98se/Me...2 Under Windows 2000/XP...9

PCI Express 4-Port Industrial Serial I/O Cards

JUNE 2000 IC136C. USB Card

USB to RS-485/RS-422 Interface Converter. User Manual

Assigning COM Port Numbers to the Serial Ports of a USBto-Serial

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

Data setting software MEXE02

8051 Basic Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

USB RS485/RS422 Converter INTRODUCTION USB-i485 USB-i485 SPECIFICATIONS USB-i485 USB-i485 NOVUS AUTOMATION 1/8

! Hardware: USB-Serial adapter, USB type A to type B cable. Software: USB-Serial driver on CD-ROM

USB to Serial Quick Installation Guide

2-Port Serial 550-Value Quick Installation Guide

EcotronsCAN User Manual

4-port USB to RS232 Adapter FTDI Cable. Product Manual. Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI.

USB Serial Converter

Cyber I/O PCI Quick Installation Guide

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

PI Scanner User Guide

PCI Serial Adapter Card

USB to Serial Converter User s Guide

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

Troubleshooting No Drive Icon of DVD CAM Appears on PC

EZSCREEN ThruTouch Touch Film. User s Guide

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

Version 2.4

Cover. MATWorX Installation Guide NWA ISSUE 2.1

DMM4020, DMM4040, and DMM4050 Connectivity Installation Manual

17 Hatidhar st. Ra anana 43665, Israel Fax: Tel: UDEC-1. Universal Debug Center User Manual & Quick Start

Wireless M-Bus Suite for Panasonic Evaluation Boards. Quick Start Guide

Cyber PCI I/O Quick Installation Guide

USB Keyboard and Mouse Console Switch User Manual

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

USB to Serial Adapter Driver Installation Manual

Transcription:

USB/PPI Programming Cable Driver Procedure Setting Guideline Introduction 2 Functions....3 System requirement. 4 The setting of driver procedure. 5 The deletion of driver procedure.9 How to change COM setting..10 Setting of Step 7-MicroWin 12 About Long Distance Communication 14 Notes and Troubleshoot..15 1/16

Introduction USB/PPI programming cable simulates USB port as traditional serial port (usually COM3), which enables existing programming software(step 7-MicroWin) to communicate through simulated traditional port and PLC devices. The working power of this cable is from USB port,not provided by the communication port of PLC.The LED of the adapter indicates the sending and receiving status of data. USB/PPI is applied to Siemens S7-200 PLC,NOT support hot plug.for the industry scene of strong interference and easily destroying communication port,pls choose optoelectronic isolated USB/PPI+ programming cable. USB/PPI principle and figure structure: PIN Signal Description 3 RxD/TxD+ Data signal B(RS485+) 8 RxD/TxD- Data signal A(RS485-) 5 GND GND Pin signal definition 2/16

Functions Support Windows2000/Windows XP Support STEP7 Micro/WIN V3.2 and higher Fully compatible with USB V1.1 and USB CDC V1.1 Power supply by USB main line.current:about 50mA. Baud rate: 300bps ~ 1Mbps Support long distance communication up to 2000m Working temperature -20~+75'C Length 3 meters.color:black One pc supports one USB programming cable only 3/16

System requirement Please make sure your PC is IBM PC compatible and has the following system requirements before using the USB programming cable. Intel is compatible with 586DX4-100MHz CPU or higher A standard USB port (4-pin A plug) Operating system is Windows2000 or Windows XP 4/16

The setting of driver procedure Please set the driver procedure according to the following steps: 1. Turning on PC power that will connect the USB programming cable and make sure the USB port working well. 2. Put the USB programming cable into USB port and Windows will detect the device and help to add new hardware and jump to new device setting. Insert the driver CD and click next to continue, or select the driver on the hard disk. If Windows does not show find new hardware, please click Universal Serial bus controllers in the hardware list of device manager, and choose the USB device with question mark. Click the right key of mouse and operate to update driver procedure. If insert the driver CD,you should select the recommended item and click Next 5/16

If the driver is saved on the hard disk, you should select the second item and click Next. You can find the driver on the WIN folder. 3. Windows will detect the setting information, and load the driver to 6/16

install. 4. Continue to set up, copy the driver procedure files to your hard disk by Windows. 5. When Windows appears Completing the Found New Hardware Wizard, click finish to end setting up. 6. After setting up, please make sure the "port (COM and LPT)" of "Start \ 7/16

Settings \ Control Panel \ system \ hardware \ Device Manager" appears "CP2101 USB to UART Bridge Controller(COMx)". This COMx is the COM message of the USB programming cable. From then on, as long as you insert the programming cable, the COM port will appear. You just have to choose this COM port in application software such as programming software or communication software. 8/16

The deletion of driver procedure Deleting driver procedure is to discharge source of COM port so that other device can be used. When driver procedure has error, it should be deleted and reset up. Please delete the driver procedure as follows: 1. Unplug the USB programming cable from you PC. 2. Choose USB Serial Converter Drivers from "Add or Delete Programs in operation panel, and click the Change/Remove button. 9/16

How to change COM setting 1. Delete the driver procedure of all USB to UART products to discharge COM port source, and reset up USB programming cable driver procedure. The device manager will display the cable address COM3. 2. In Windows 2000/XP the COM slogan can be changed directly. Please double click COM port device that is need changing in the device manager, and the device attribute information window will appear. Choose port setting as the picture shows. Click "Advanced" button, and the advanced setting information window will appear. Set the COM port to the serial number you want and click "OK" button to complete. 10/16

11/16

Setting of Step 7-MicroWin Open the main windows form(step7-microwin), click Set PG/PC Interface of the left view and will appear PG/PC setting window. 1.Double click PC/PPI cable(ppi) to open COM port and PPI port parameter setting dialog box. 2.Click Local Connection to set COM port parameter, choose correctly 12/16

COM port in the device manager after install the driver, and set the transmission rate as 9600bps or 19200bps,which is both OK, then the USB/PPI will adapt the baud rate automatic. 13/16

About Long Distance Communication For USB/PPI, the largest communication distance is up to 2000m at the communication speed of 9600bps. It needs to splice 120ohm terminal resistance between 3 and 8 pin on the RS485 port(db9 Male) to eliminate signal reflection. But requires one PFB-G for each PLC. 14/16

Notes and Troubleshoot 1. If the USB programming cable could not be detected when opening the PC, or some other outstanding issues occur, please replug it again. 2.USB to UART is plug and play USB device. When data are being transmitted, please don t disconnect it. 3. Sometimes when Windows System failures or outstanding issues when plug or unplug the USB cable occur, please restart the computer and PLC. 4. USB/PPI cable don t support USB interface in the Step7-MicroWin,so you should choose COM port. 5. If the COM port with * symbol in the software,such as *COM3,it indicates this COM port is at fault,pls exit programming software and then replug the USB port or reinstall the USB driver. 6. It doesn t support 187.5Kbps baud rate. 15/16

Rejection provision This document is to provide information, and the contents will not be noticed when revising. Because of the direct or indirect loss or errors caused by revised document, will not be the responsibility of the manufacturer. 16/16