Installation Instructions

Similar documents
Installation Instructions

TOUCH TRACKER with Quad Splitter

Quick Reference Guide

E2460GS Oscilloscope Upgrade Kit

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

Digital Keypad Introduction

CDD Carbon Dioxide Transmitter

Perle MCR200 Installation Guide

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

PXL-250 Tiger Controller

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Installing and Removing SDRAM and DRAM

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

and Network Interface Modules Installation Instructions

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

CDD4 Duct Carbon Dioxide Transmitter

Contents. Chapter 1 Introduction to the CP-10. Keys and Functions Checking Software Version Technical Support...1-5

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

Contents. Chapter 1 Introduction to the CP-20. CP-20 Control Panel Technical Support Chapter 2 Executing Switches

TC-9102 Series Surface Mount Temperature Controllers

Series 3700 Screw Terminal Assemblies Installation Instructions

Figure 1. 6-Way JAMMA Switcher

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

300XAC. Quick Start Guide. Modular AC Power Source MODELS 310XAC, 320XAC, 340XAC, 360XAC

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Installation Instructions

EA500. Installation Instructions Transponder

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

E1135C PDU and Pod Upgrade Procedure

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

Connecting a Cisco Reader Module

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

CP150B Vandal & Weather Resistant Keypad Security Systems

CM X8 Matrix Switcher/ Controller

Quick Start Installation Guide

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

Installing the DX LCD Display

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

CM X6 Matrix Switcher

9212i INSTALLATION. Stand-Alone Keypad. Instructions

SC6540. Quick Start Guide

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

ADSDUIOB / ADSDUIOBW Mounting Base Indoor Installation

CDD4 Series Room CO2 Transmitter Installation Instructions

Multiple Digital Messaging Unit

Quick Start Installation Guide

Maintaining the Cisco Catalyst 5500 Multiswitch Router

KTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

TruPortal Dual Door Interface Module Quick Reference

AL168 Series Multi-Output Power Supplies

HYPOT III. Quick Start Guide

Installation OVERVIEW

Power Supply and Fan Module Installation

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Replacing the Power Supply

INSTALLATION TIPS AND MAINTENANCE Manual Number

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

LC1003A IP Security CCTV Connector Installation Guide

Routing Power and Signal Cables

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

TeamWork 400 and TeamWork 600 Kits Installation Guide

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 1.

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

THE CTB08D LIGHT CONTOLLER

M40e and M160 CIP Installation Instructions

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

PowerShield 8. Installation Manual

PM Series Power Meter

OilCop Component Wiring Installation Manual

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Tone Generator and Probe

Routing Power and Signal Cables

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

2000 Series e/em Style Keypad Installation and Programming Manual

Chapter 2. Installing the Chapter 2. Contents

Perle SMI Media Converter Installation Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

Installation and Operation

MegaPower CPU ADMPCPU

FDS / FDS-R / FDS-PS

Informer In Line Fluid Monitoring Package

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3.

KP2000E/EM Series Style Keypad

Transcription:

ADS32X Touch Tracker with Video Matrix Switcher Installation Instructions Parts Required Touch Tracker Installation Kit: Part Number 0351-0474-07 INSTL KIT, TOUCH TRKR, W/ 1 Description Qty Part No. CABLE ASSY,MDLR,14FT,8 COND,CROSS-P 1 6003-0047-01 SCR,THD CUT,M2.9X9.5,PHP,ST,Z,T1 1 5899-0004-102 ANCHOR,PLASTIC,W/O SCREW,8-10 2 2880-0083-01 SCR,TYP AB,PHP,CAD,#8X1" 2 2816-7634-44 CONN,PLUG,TUBLR,.200CTR,26-12AWG,1X 1 2109-0254-04 LUG,SPADE,CRIMP,INSUL,22-16AWG 3 2141-0002 CABLE,3COND,18AWG,CM 16.5 6002-0024-01 INTERCONNECT BOX,TOUCHTRACKER 1 0300-1000-01 CABLE ASSY,TOUCH TRACKER,INTFC TO Q 1 0650-0932-01 HOOD,D-SUB,9POS,EMI/RFI,.25 DIA CAB 1 2125-0007-02 CONN,D-SUB,PLUG,HSG,9POS,SSI 1 2130-0021-01 FERRITE CORE 1 2700-0023-01 QUICK REFERENCE GUID 1 8000-1674-01 TOUCH TRACHER STRAIN RELIEF INSTR 1 8000-1370-01 Installation Procedures W A R N I N G RISK OF ELECTRIC SHOCK! Disconnect AC Power. CAUTION ELECTROSTATIC SENSITIVE DEVICES! Follow proper handling procedures to prevent component failure. See Remote Switcher Location for procedures when the Video Matrix Switcher will be more than 4m (14 ft) from the EIMs. 1. Attach each EIM to a wall or other surface within 3m (10 ft) of its Touch Tracker controller. 2. Terminate the EIM that is at the end of the SensorNet network. See Figure 1 for the wiring diagram for a typical 2- controller AD32 system installation. For more information on the SensorNet network, see the SensorNet Network Guide (PN 8000-0970-01). 3. Attach the 3 spade lugs to one end of the 3- conductor cable, then attach the lugs to the EIM power transformer. 4. Connect the power transformer cable and the SensorNet data cable, and if required, the data cable to EIM #2, to the compression connector, and connect it to J3 on each EIM. 5. Wire the DB9 connector to the data cable. See the tables in Figure 1. Assemble the hood onto the DB9 connector. 6. Install the ferrite core onto the cable assembly, 2.54-3.81cm (1 in.-1.5 in.) from the connector (see Figure 2). 7. Connect the data cable to J1 on the EIM to the RS232 port 1 (primary) or port 2 (secondary) on the rear panel of the Video Matrix Switcher. 8. Connect a modular cable to J2 on EIM and to the Touch Tracker controller. 9. Plug each power transformer into a grounded, 3-wire receptacle. NOTE: If the keypad and backlighting do not illuminate when power is applied, unplug the power transformers, check all wiring connections, and repeat step 9. 10. Press Menu on the Touch Tracker keypad to calibrate the controller. 11. Using the Tracker Ball, page down the screen to the Calibration menu option. 12. Press the zoom button to select the Calibrate menu option if it is displayed on the top line of the LCD window, or press the focus button if it is displayed on the second line. 13. Perform the Tracker Ball operations displayed in the LCD window until Calibration Done appears in the window. 14. Press Menu to save the configuration and return to the Camera Control mode. 15. To configure the Touch Tracker controller as a primary or secondary unit, page down the screen to the Tog Primary/2nd menu option. 16. To select the Tog Primary/2nd menu option, press the zoom (top line) or focus (bottom line) button, as appropriate. 17. Press Next to toggle between using the Touch Tracker controller as the primary unit or as the secondary unit. 18. Press Menu to reset the Touch Tracker controller as a primary or secondary unit. The controller will reboot to the Camera Control Mode. 8000-1691-02. Rev. A (7 pages) AD32 1

Figure 1. AD32 Wiring Diagram J-Box P8 COLOR PIN Function Orange 1 Host A Yellow 2 Host B Orange 3 Auxiliary A Yellow 4 Auxiliary B J-Box P1-P6 COLOR PIN Function Orange 1 SensorNet A White 2 28Vac Red 3 Ground Black 4 28Vac Yellow 5 SensorNet B J-Box #1 J-Box #2 P4 P1 P4 P1 P5 P2 P5 P2 EIM Transformers P6 P8 P6 P8 24 Vac A Ground 24 Vac B 21 21 3 2 1 UNTERMINATED NOTE: The system supports up to 2 controllers. Terminate E1 on the EIM that is on an end point of the SensorNet network. DB9 (M) EIM DB9 (M) COLOR PIN FUNCTION Green 3 Receive Red 2 Transmit Orange 5 Ground 24 Vac A Ground 24 Vac B EIM #1 1-2 TERMINATED 2-3 UNTERMINATED E1 32 1 J3 5 2 3 J1 ASSY 0301-0340-01 REV- 2 1 J2 EIM #2 DB9 (M) 1-2 TERMINATED 2-3 UNTERMINATED E1 3 2 1 J3 J1 ASSY 0301-0340-01 REV- 5 2 3 2 1 J2 UniCard Modular 3 2 1 TERMINATED UniCard Wiring COLOR PIN FUNCTION Orange 1 SensorNet A Yellow 2 SensorNet B Black 3 24Vac A Red 4 Ground White 5 24Vac B UniCard NOTE: The maximum combined SensorNet cable length is 1219m (4000'). Secondary TOUCH TRACKER Primary TOUCH TRACKER Data Ferrite Core Video Matrix Switcher Ferrite Core CAMERAS 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32 5 4 2 ALARMS 5 4 2 1 2 3 4 5 6 7 8 SI NO NC C MONITORS RELAY 1 2 3 4 5 1 2 3 Wiring COLOR PIN Green 5 Red 4 Orange 2 120Vac, 60Hz or 240Vac, 50Hz 120V 60Hz RS232 PORTS 2 INSTALLATION INSTRUCTIONS ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER

Calibrating the Tracker Ball The Calibration menu option will appear on the first line. 2. Press the zoom (line 1) or focus (line 2) button to select the Calibration menu option. 3. Follow the instructions on the LCD screen. 4. Press Menu to exit. If you do not follow each instruction on the screen, the dome may not function properly. Re-calibrate the Tracker Ball if the dome does not pan or tilt properly. Calibration is only for the Touch Tracker controller. Resetting a Dome 1. Use the number buttons to select the dome to reset, then press Camera. 2. Press Menu. 3. Using the Tracker Ball, scroll down to Reset Dome. 4. Press the zoom (line 1) or focus (line 2) button to select the Reset Dome menu option. The Touch Tracker will send a request to the selected dome to reboot. Switching Primary and Secondary Functions between Controller Units Tog Primary/2nd. to select the Tog Primary/2nd menu option. 4. Press Next to toggle between using the primary unit for SensorNet polling and alarm monitoring or as the secondary unit with limited user functionality. 5. Press Menu to reset the controller as a primary or secondary unit. The controller will reboot and return to the Camera Control Mode. Switching Zoom and Focus Functions between Left and Right Buttons Tog Zoom/Focus. to select the Tog Zoom/Focus menu option. 4. Press Next to switch the Zoom and Focus functions between the right and left buttons. 5. Press Menu to save the configuration and exit. Adjusting V-Phase Adjust V- Phase. to select the Adjust V-Phase menu option. 4. Press Next or Prev to observe V-Phase through the oscilloscope or Fluke scope. 5. Press Menu to exit. Off-line domes or fixed cameras will generate a warning beep and disallow use of the V-Phase utility. For additional information on adjusting V-Phase, see the Service section of the AD32 Installation and Service Manual. Figure 2. Ferrite Core Attachment DB9(M) 2.54-3.81 cm 0 in (1" - 1.5") Ferrite Core Place 1 loop into core slot; close core halves; gently pull cable to tighten loop. ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER INSTALLATION INSTRUCTIONS 3

Reviewing System Information System Info. to select the System Info menu option. The LCD screen displays the following message: Primary/Secondary Indicator: Primary Unit <NEXT> <PREV> 4. Press Next to step through the following messages: Flash and EEPROM checksum values: ROM Checksum E=0A7B F=9C82 EEPROM Checksum Flash Checksum Tracker Ball calibration values: Min 63 60 61 60 Max D3 C3 C6 DE Left Right Up Down Flash and EEPROM part numbers (including version): Product Code F 0701-0000-0000 Flash Part Number and Version Product Code E 0701-0000-0000 EEPROM Part Number and Version 5. Press Menu to exit. Performing SensorNet Ping Test 1. Use the number buttons to select a dome to test, then press Camera. 2. Press Menu. 3. Using the Tracker Ball, scroll down to Ping Dome/TTR. 4. Press the zoom (line 1) or focus (line 2) button to select the Ping Dome/TTR menu option and to start the ping test on the selected dome. The LCD screen displays the following message: *=Device being tested *Dome TTR Tx=0006 Bad=0002 No. of pings transmitted No. of failed responses 5. Press Next to perform the ping test on the Secondary Touch Tracker controller unit. 6. Press Menu to exit. Off-line domes or fixed cameras will generate a warning beep and disallow use of the SensorNet network test. Changing the Port Setting Port Settings. to select the Port Settings menu option. The LCD screen displays the following message: *=Selected mode *Operating Mode Download Mode 4. Press Next to change the currently selected mode. 5. Press Menu to save the change and exit. 4 INSTALLATION INSTRUCTIONS ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER

Remote Switcher Location If the EIM and Touch Trackers will be located more than 4m (14 ft) but less than 15m (50 ft) from the Video Matrix Switcher, the following additional equipment will be needed: Description Qty Part No. CABLE ASSY,MDLR,14FT,8 COND,CROSS-P 1 6003-0047-01 TERMINAL, 2 2113-0019-01 ANCHOR,PLASTIC,W/O SCREW,8-10 4 2880-0083-01 SCR,TYP AB,PHP,CAD,#8X1" 4 2816-7634-44 CABLE,3COND,18AWG,4M-15M (14-50 ) 1 6002-0024-01 WARNING: Shock Hazard! Disconnect AC Power. CAUTION: static sensitive components! Follow proper handling procedures to prevent component failure. Installation Procedures 1. Attach each EIM to a wall or other surface within 3m (10 ft) of its Touch Tracker controller. 2. Terminate the EIM at the end of the SensorNet network. See Figure 1 for the wiring diagram for a typical 2-controller AD32 system installation. See Figure 3 for the wiring diagram for remotely located Video Matrix Switcher. For more information on the SensorNet network, see the SensorNet Network Guide (PN 8000-0970-01). 3. Attach the HP0047 terminal boxes to a wall. The remote terminal box must be within 15m (50 ft) of the EIM terminal box. 4. Connect the 3-wire, 18AWG shielded cable to the terminal boxes (see Figure 3). 5. Attach the 3 spade lugs to one end of the 3- conductor cable, then attach the lugs to the EIM power transformer. 6. Connect the power transformer cable and the SensorNet data cable, and if required, the data cable to EIM #2, to the compression connector, and connect it to J3 on each EIM. 7. Wire the DB9 connector to the data cable. See the tables on page 2. Assemble the hood onto the DB9 connector. 8. Connect the data cable to J1 on the EIM to the HP0047 terminal box. 9. Install a ferrite core onto a modular cable assembly, 2.54-3.81cm (1 in.-1.5 in.) from an connector (see Figure 2). 10. Connect the modular cable to the remote HP0047 terminal box and to the RS232 port 1 (primary) or port 2 (secondary) on the rear panel of the Video Matrix Switcher. 11. Connect a modular cable to J2 on EIM and to the Touch Tracker controller. 12. Plug each power transformer into a grounded, 3-wire receptacle. NOTE: If the keypad and backlighting do not illuminate when power is applied, unplug the power transformers, check all wiring connections, and repeat step 9. 13. Press Menu on the Touch Tracker keypad to calibrate the controller. 14. Using the Tracker Ball, page down the screen to the Calibration menu option. 15. Press the zoom button to select the Calibrate menu option if it is displayed on the top line of the LCD window, or press the focus button if it is displayed on the second line. 16. Perform the Tracker Ball operations displayed in the LCD window until Calibration Done appears in the window. 17. Press Menu to save the configuration and return to the Camera Control mode. 18. To configure the Touch Tracker controller as a primary or secondary unit, page down the screen to the Tog Primary/2nd menu option. 19. To select the Tog Primary/2nd menu option, press the zoom (top line) or focus (bottom line) button, as appropriate. 20. Press Next to toggle between using the Touch Tracker controller as the primary unit or as the secondary unit. 21. Press Menu to reset the Touch Tracker controller as a primary or secondary unit. The controller will reboot to the Camera Control Mode. ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER INSTALLATION INSTRUCTIONS 5

Figure 3. VMS Wiring Diagram Remote Switcher Location 24 Vac A Ground 24 Vac B Transformer EIM J1 2 1 J3 J2 J3 Wiring Pin Function 1 N/A 2 24Vac A 3 Ground 4 24Vac B 5 N/A DB9 (M) DB9 (M) Wiring Color Pin Function Green 3 Receive Red 2 Transmit Orange 5 Ground Wiring Color Pin Green 5 Red 4 Orange 2 EIM Terminal Box 5 2 3 5 4 2 8 1 7 2 6 5 4 3 Data Modular 8 1 7 2 6 5 4 3 Modular Remote Terminal Box Touch Tracker 3-wire, 18AWG Ferrite Core Shield Video Matrix Switcher CAMERAS 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32 ALARMS RELAY 2 3 4 5 6 SI NO NC 1 7 8 C MONITORS 1 2 3 4 5 1 2 3 120Vac, 60Hz or 240Vac, 50Hz 120V 60Hz RS232 PORTS 6 INSTALLATION INSTRUCTIONS ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER

Alarm and Relay Connections The back panel of the AD32 Video Matrix Switcher provides eight alarm contact inputs, an external frequency synchronization input, and contact terminations for an internal alarm-activated relay. You can program the Form-C internal relay to activate during alarms for control of a VCR or other alarm response device. Figure 4. Alarm/Relay Connections Pin ALARMS RELAY Pin 16 1 2 3 4 5 6 7 8 SI NO NC C Connections Alarms Alarm contact closures must have a resistance of 500 Ohms or less. Connect alarm contacts to inputs 1 through 8 (pins 2 through 9). Connect alarm contact returns to Ground (pin 1 or 10). External Sync External sync input signal must be 1-5Vrms, 50/60Hz. Connect external sync input to SI (pin 12). Connect external sync ground to Ground (pin 11). CAMERAS 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32 ALARMS 1 2 3 4 5 6 7 8 SI NO NC C MONITORS 1 2 3 4 5 1 2 3 RS232 PORTS The following is a description of the alarm and relay connector pins. Pin Description 1 Ground 2 Alarm 1 3 Alarm 2 4 Alarm 3 5 Alarm 4 6 Alarm 5 7 Alarm 6 8 Alarm 7 9 Alarm 8 10 Ground 11 External Sync Ground 12 External Sync Input 13 Ground 14 Relay Normally Open 15 Relay Normally Closed 16 Relay Common RELAY Video Matrix Switcher Rear Panel 120Vac, 60Hz or 240Vac, 50Hz 120V 60Hz Relay Connections for the internal relay are normally open (NO), normally closed (NC), and common (C). The relay contact ratings are 0.6A @ 120Vac / 0.3A @ 240Vac or 2.0A @ 30Vdc. Connect an alarm-response device requiring a normally open circuit to NO (pin 14) and C (pin 16). Connect an alarm-response device requiring a normally closed circuit to NC (pin 15) and C (pin 16). ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER INSTALLATION INSTRUCTIONS 7