IVDR Breakout. Copyright 2017 BSI. All rights reserved.

Similar documents
Med-Info. Council Directive 93/42/EEC on medical devices. TÜV SÜD Product Service GmbH

Med-Info. Council Directive 93/42/EEC on medical devices. TÜV SÜD Product Service GmbH

Mapping Your Success 2013 BSI Healthcare Roadshow: Mobile Health Software, Mobile Phones and Telemedicine Under the EU Approach

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

WEBINAR on the new Medical Device Regulation One-stop testing, inspection, certification and training solutions. TÜV SÜD Product Service

Regulatory Aspects of Digital Healthcare Solutions

RECOMMENDATION FOR USE

Rules for LNE Certification of Management Systems

QP Current Practices, Challenges and Mysteries. Caitriona Lenagh 16 March 2012

The Role of the QP in MA Compliance

Conformity assessment

Requirements on clinical data in Europe

UDI in the MDR. Economic Operators The new regulations create Economic Operators who play a role in the UDI system.

1. STRATEGIC PLANNING

National Accreditation Scheme

SPECIFIC PROVISIONS FOR THE ACCREDITATION OF CERTIFICATION BODIES IN THE FIELD OF FOOD SAFETY MANAGEMENT SYSTEMS

SIRIM QAS International Sdn. Bhd.

SIRIM QAS International Sdn. Bhd.

Guidelines 4/2018 on the accreditation of certification bodies under Article 43 of the General Data Protection Regulation (2016/679)

ENCePP Code of Conduct Implementation Guidance for Sharing of ENCePP Study Data

ARTICLE 29 DATA PROTECTION WORKING PARTY

An unofficial translation, in case of any discrepancies between the English version and the original Swedish version the latter will prevail.

UDI Implementation Update. GS1 UK Healthcare Conference - 22 November 2017 John Wilkinson OBE Medicines and Healthcare Products Regulatory Agency

Accreditation of Product Certification Scheme for Construction Materials By Ir C K Cheung Hong Kong Accreditation Service

PRODUCT CERTIFICATION SCHEME FOR METROLOGY SYSTEM

BRE Global Limited Scheme Document SD 186: Issue No December 2017

Guide to Applications for Certificates of Free Sale for Medical Devices

PTSPAS Product Assessment HAPAS Equivalent in accordance with MCHW SHW Volume 1 Clause and

Vaccine data collection tool Oct Functions, Indicators & Sub-Indicators

APPROVAL SHEET PROCEDURE INFORMATION SECURITY MANAGEMENT SYSTEM CERTIFICATION. PT. TÜV NORD Indonesia PS - TNI 001 Rev.05

Network Certification Body

ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES

INAB Mandatory and Guidance Documents Policy and Index

Q&A QP Declaration. Table of contents

INAB Mandatory and Guidance Documents Policy and Index

PRODUCT CERTIFICATION SCHEME FOR ENERGY DRINKS

Med-Info. Malaysia Medical Device Regulations. TÜV SÜD Product Service GmbH. International expert information for the medical device industry

Scheme Document. For more information or help with your application contact BRE Global on +44 (0) or

ISO/IEC :2015 IMPACT ON THE CERTIFIED CLIENT

Medical Device Usability

Regulations for Compulsory Product Certification

EXAM PREPARATION GUIDE

ITU Asia-Pacific Centres of Excellence Training on Conformity and Interoperability. Session 2: Conformity Assessment Principles

Content of mandatory certificates

EXAM PREPARATION GUIDE

Alexion Pharma International Trading

ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES

Inter American Accreditation Cooperation. IAAC, IAF and ILAC Resolutions Applicable to IAAC MLA Peer Evaluations

Gdańsk, DECEMBER 2017

Guidance for the format and content of the final study report of non-interventional post-authorisation safety studies

Regulation for the accreditation of product Certification Bodies

Quality Assurance International standards (ISO/CLSI) Susanne Karlsmose DTU Food, Denmark

!"# $ # # $ $ % $ &% $ '"# $ ()&*&)+(( )+(( )

EA-7/05 - EA Guidance on the Application of ISO/IEC 17021:2006 for Combined Audits

PEFC Norway Standard Document PEFC Norway ST 2002:2009 Issue

Task 57 Solar standards and certification Version 1.1. Guideline for Implementing Certification Schemes for Solar Heating and Cooling Products

Harris County Onsite Wastewater Seminar. NSF International 2015

PRODUCT CERTIFICATION SCHEME FOR MILK AND DAIRY PRODUCTS

Introduction to UKAS Accreditation Fire Scene Development Programme. David Compton November 2017

In-Vitro Diagnostic Directive (IVDD) and IVDD Technical File Preparation Workshop. 3-4 July 2014 TÜV SÜD

PRODUCT CERTIFICATION SCHEME FOR MECHANICAL-CUSTOMIZED VEHICLES

MODEL CERTIFICATE FOR FISH AND FISHERY PRODUCTS CAC/GL

South African Forestry Assurance Scheme SAFAS 6:2018. Certification and Accreditation Procedures. Issue SAFAS Council SAFAS

EXAM PREPARATION GUIDE

USING STANDARDS TO ASSESS THE COMPETENCE OF CONFORMITY

UDI in Europe. Mr. Salvatore Scalzo, Policy and Legal Officer, Medical Devices, DG GROW, European Commission. 19 October 2017

klinischen Datenanforderungen in Europa: Ist die Literaturroute noch möglich?

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

AUDITOR / LEAD AUDITOR PHARMACEUTICAL AND MEDICAL DEVICE INDUSTRY

PECB Change Log Form

UKAS accredited Certification Bodies

TURKISH STANDARDS INSTITUTION

Use Cases for Argonaut Project -- DRAFT Page

Sparta Systems TrackWise Digital Solution

Accreditation programme for management systems certification bodies NAR IRT Edition 2

Abu Dhabi Certification Scheme for Pool Lifeguard Assessment and Surveillance Plan for Pool Lifeguard

S. Scholz / K. Meyer / J.E. Nielsen / Harald Drück/J.Fernández/E.Prado/L.Nelson Page 1 of 7

PRODUCT CERTIFICATION SCHEME FOR CHILDREN TOYS

PECB Certified ISO Lead Auditor. Master the Audit of Occupational Health and Safety Management System (OHSMS) based on ISO 45001

A80F300e Description of the SA8000:2014 certification procedure

RECOMMENDATION FOR USE

Acceptance Checklist for Special 510(k)

EA Document for Recognition of Verifiers under the EU ETS Directive

Base Standard Program ISO Medical Device CB Application for Accreditation

Classification and regulation of software

IAF Mandatory Document for the Transfer of Accredited Certification of Management Systems

Data Processing Clauses

Orion Registrar, Inc. Certification Regulations Revision J Effective Date January 23, 2018

Abu Dhabi Certification Scheme for Beauty Salon Sector

Personnel Certification Program

EXAM PREPARATION GUIDE

SAS Rules for Accreditation Purposes in the context of Notification - Designation of Conformity Assessment Bodies (CAB)

ISO/IEC INTERNATIONAL STANDARD

Sources of Test Reports for TUV SUD BABT Product Certification BABT766. TUV SUD BABT is a certification body of. TUV SUD BABT 2015 Issue 7

Voluntary certification at an intermediate stage of manufacture

eias Study on an electronic identification, authentication and signature policy SUPERVISION Presentation on status

USDA ISO Guide 65 Program Accreditation for Certification Bodies

BENEFITS OF EXCIPACT CERTIFICATION TO SUPPLIERS, USERS AND PATIENTS The role in Supplier Qualification. March 2011

Ref No: RACS/PCS/10 Page 1 of 7. Revision No: 00 Revision Date: October 1, 2018 PRODUCT CERTIFICATION SCHEME FOR ELECTRICAL EQUIPMENT

EXAM PREPARATION GUIDE

Transcription:

IVDR Breakout 1

IVDR Classification and conformity assessment 2

Classification- IVDR 3

Classification of IVDs Re-classification of IVDs will mean 80-90 % will no longer be able to self certify conformity Review of technical documentation will be at the same depth for all devices, but there will be sampling proportionate to risk More scrutiny on risk, clinical evidence and post-market surveillance D C B A Image of 4 risk groups High Population, High Patient risk Low Population, High Patient risk Medium-low patient Low patient risk 4

Classification rules Annex VIII Rule 1 Rule 2 Rule 3 Rule 4 Rule 5 Rule 6 Rule 7 Blood screening High risk disease Infectious disease Cancer Self testing reagents testing N Blood or N N N N tissue Companion Instruments compatibility diagnostics High risk near- Genetic patient testing tests Congenital screening Specific IVD Specimen receptacles None of the other rules Controls no assigned values Y Y Y Y Y Y Y D C High risk blood groups Y D C Self test: Exempted List C A B B Y B 5

New classes of IVD devices Class D Class C Class B Class A High public health risk, high personal risk High personal risk, moderate to low public health risk Moderate to low personal risk, low public health risk Low personal risk, low public health risk Examples HIV 1/2, Hepatitis C virus Hepatitis B virus HTLV I/II Blood grouping ABO, Rhesus (including RHW1), Kell, Kidd and Duffy systems CHAGAS Syphilis (used to screen blood donations) Syphilis (diagnosis only) Neonatal screening for metabolic disorders e.g. PKU Rubella Cancer markers Genetic tests Companion diagnostics Blood glucose meters/strips Blood gas analysers Self tests Thyroid function Infertility assays Clinical chemistry Self-test devices that are not Class C: pregnancy, fertility, cholesterol and urine tests for glucose, erythrocytes, leucocytes and bacteria Near patient tests are classified in their own right Accessories Wash buffers Specimen receptacles Instruments Culture media 9

Conformity Assessment - IVDR 10

Your device is ready to be placed on the market 1. Routes to Conformity What are your options? Role of a Notified Body 2. Annex VIII QMS Assurance QMS Audit Documentation assessments Class Ds & EU Reference Laboratories Certificates issued 3. Annex IX & X - Type examination & Production Quality Assurance So you have your CE certification 4. Maintaining your certification 11

Routes to Conformity 12

What are your options Conformity assessment routes are based on classification of the device/group of devices Manufacturer s choice of conformity route, in line with classification Device / group of devices Analyte, intended use, technology Plan for the scope of your certification 13

Conformity assessment A B C D EU Declaration of Conformity Annex III Quality Management System Assurance Annex IX Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Assessment of Documentation per category device - Annex IX 4.4-4.8 Assessment of Documentation per generic device - Annex IX 4.4-4.8 Production Quality Assurance Annex XI Assessment of Documentation Annex IX Ch II Production Quality Assurance Annex XI For Companion Diagnostics CA consultation Annex IX 5.2 For Companion Diagnostics CA consultation Annex X 3 Verification by EU Reference Laboratory Verification by EU Reference Laboratory 14

What is the NB role? The role of a Notified Body in the conformity assessment process A Notified Body is designated by an EU Competent Authority to perform conformity assessments Assessment based on the evidence & conclusions provided, that the device conforms to the relevant requirements (General Safety and Performance requirements) A Notified Body must demonstrate that it is competent to perform these reviews (based on NBOG codes) Annex VI shall carry out the conformity assessment activities with the highest degree of professional integrity and the requisite technical and scientific competence in the specific fields. 15

To start the conformity assessment process Quotation and Application Formal application by manufacturer to a NB Contract between both parties Terms to include: Application to single NB; information about previous applications for the same device Manufacturer to inform NB of vigilance reports Right of NB to suspend, restrict, or withdraw certificates NB must be able to fulfil their information obligations Contract review by NB Scope of designation Competency for assessment 16

Annex IX QMS Assurance 17

Conformity assessment A B C D EU Declaration of Conformity Annex III Quality Management System Assurance Annex IX Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Assessment of Documentation per category device - Annex IX 4.4-4.8 Assessment of Documentation per generic device - Annex IX 4.4-4.8 Production Quality Assurance Annex XI Assessment of Documentation Annex IX Ch II Production Quality Assurance Annex XI For Companion Diagnostics CA consultation Annex IX 5.2 For Companion Diagnostics CA consultation Annex X 3 Verification by EU Reference Laboratory Verification by EU Reference Laboratory 19

Quality Management System Assurance 1. QMS Audit Quality Objectives Organisation and monitoring Mandate with an Authorised Representative if applicable Procedures (data and records) for monitoring, verifying, validating and controlling device design Regulatory compliance Identification of requirements Risk management Performance evaluation and PMPF Labelling Management of changes Where a harmonised QMS standard is used, the NB shall audit to that standard 20

Quality Management System Assurance 1. QMS Audit Assessment of QMS of manufacturer and any additional sites Appropriate scope Device/s to be covered by QMS Procedures necessary to fulfil IVDR requirements Post-market surveillance Post-market performance follow up plan Vigilance procedures Performance evaluation plan and procedures On-site audit Implementation of the QMS to ensure compliance 21

Quality Management System Assurance 1. QMS Audit QMS obligations for the Manufacturer of the IVDR map to ISO 13485:2016 Except for: Transition to certification to ISO 13485:2016 will help on your road to CE marking under the IVDR! 22

Quality Management System Assurance 2. Assessment of Documentation on a sampling basis (Class C & B) Annex IX (I & III); Chapter II, Sec 4.4-4.8 only sampling: Based on novelty of technology, risk of device and standard medical practice, similarities of design, technology and manufacturing Generic devices (C) or Device subcategories (B) Performance Evaluation Report Clinical evidence based on equivalence, NB will need to assess claimed equivalency, relevance and adequacy of data Adequacy of performance evaluation, risk-benefit, IFU, post-market surveillance, and any Post-Market Performance Follow-up Possible post-market NB follow up Performance Evaluation Assessment Report will be issued by NB Content dependent on device 23

Quality Management System Assurance 3. Assessment of Documentation Class D & Self-Tests / Near Patient Tests Annex IX (I & III) + Chapter II documentation Annex II Performance Evaluation Report Clinical evidence based on equivalence, NB will need to assess claimed equivalency, relevance and adequacy of data Adequacy of performance evaluation, risk-benefit, IFU, post-market surveillance, and any Post-Market Performance Follow-up Possible post-market NB follow up Performance Evaluation Assessment Report EU Documentation certificate will be issued (Product specific) Content dependent on device 24

Quality Management System Assurance 3. Assessment of Documentation Class D & Self-Tests / Near Patient Tests Annex IX (I & III) + Chapter II documentation Annex II Performance Evaluation Report Clinical evidence based on equivalence, NB will need to assess claimed equivalency, relevance and adequacy of data Adequacy of performance evaluation, risk-benefit, IFU, post-market surveillance, and any Post-Market Performance Follow-up Possible post-market NB follow up Performance Evaluation Assessment Report EU Documentation certificate will be issued (Product specific) Draft declaration of conformity Annex III Labelling (CE xxxx ) 25

Conformity assessment A B C D EU Declaration of Conformity Annex III Quality Management System Assurance Annex IX Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Assessment of Documentation per category device - Annex IX 4.4-4.8 Assessment of Documentation per generic device - Annex IX 4.4-4.8 Production Quality Assurance Annex XI Assessment of Documentation Annex IX Ch II Production Quality Assurance Annex XI For Companion Diagnostics CA consultation Annex IX 5.2 For Companion Diagnostics CA consultation Annex X 3 Verification by EU Reference Laboratory Verification by EU Reference Laboratory 26

EU Reference Laboratories & Class D devices In addition to QMS and Documentation audit part of conformity assessment: Compliance with the Common Specification Query on transition arrangements to current Common Specification Consultation with MDCG where no Common Specification EU Reference laboratory will verify claimed performance of the device and compliance with Common Specification or other solutions Scientific opinion within 60 days Ref Lab will also be involved in review of device changes post-market EU Reference laboratories will need to be designated Time frame dependent on implementing provisions 27

EU Reference Laboratories & Class D devices Batch release differences compared to IVD Directive: All batches will have to be tested IVDR does not allow for reducing the level of testing after a certain number of batches All batches will have to be tested by an external laboratory IVDD allows testing to take place in the manufacturer s laboratory with a panel of samples supplied by the NB It is assumed that the Reference Lab for testing of the batches will be the same at the Reference Lab that reviews the performance data, however, this has not been confirmed by CAs 28

Definition Companion Diagnostic means a device which is essential for the safe and effective use of a corresponding medicinal product to: - identify, before and/or during treatment, patients who are most likely to benefit from the corresponding medicinal product; or - identify, before and/or during treatment, patients likely to be at increased risk for serious adverse reactions as a result of treatment with the corresponding medicinal product; 29

IVDR, Annex VIII 6.2 Examination of the design of companion diagnostics a) Manufacturer applies to Notified Body for examination of technical documentation b) Documentation to enable assessment of conformity with the IVDD c) Notified body consults with the European Medicines Agency (EMA) or country competent authority (CA) d) EMA or CA gives opinion to the Notified Body within 60 days e) Notified body gives due consideration to EMA/CA input f) Manufacturer to notify the Notified Body of changes. Notified Body determines if a new assessment is needed. Notified Body seeks EMA/CA input 30

Certificates issued under Annex IX Class B & C devices 1. EU Quality Management System certificate (Annex IX, I & III) Accompanied by assessment of technical documentation on representative basis for each generic device group (C) or device category (B) Ref Article 48 31

Certificates issued under Annex IX Class B & C devices Class D & Others specified* 1. EU Quality Management System 1. EU Quality Management System certificate certificate (Annex IX, I & III) (Annex IX, I & III) Accompanied by assessment 2. of EU Documentation Assessment certificate technical documentation on (Annex IX, II exclu sec 5) representative basis for each generic device group (C) or device category For each Class D device to be placed on the market (B) Reference laboratory will verify claimed performance and Common Specification requirements needs to be positive outcome Ref Article 48 MDCG consultation if no Common Specification Verification of manufactured batches (Class D) *Self-test and near patient tests, Classed B-D; Companion Diagnostics 32

Certificates issued under Annex IX Class B & C devices 1. EU Quality Management System 1. EU Quality Management System certificate certificate (Annex IX, I & III) (Annex IX, I & III) Accompanied by assessment 2. of EU Documentation Assessment certificate technical documentation on (Annex IX, II exclu sec 5) representative basis for each generic device group (C) or device category For each Class D device to be placed on the market (B) Reference laboratory will verify claimed performance and Common Specification requirements needs to be positive outcome Ref Article 48 Class D & Others specified* MDCG consultation if no Common Specification Verification of manufactured batches (Class D) OR EU Documentation Assessment certificate (Annex IX, II sec 5) For each device* to be placed on the market (to be confirmed) Drug consultation for Companion Diagnostics *Self-test and near patient tests, Classed B-D; Companion Diagnostics 33

QMS Assurance conformity assessment process Quality Management System Assurance under the IVDR What will be needed Application to a NB QMS certification with a scope to cover the processes / technologies / devices QMS assessment by a NB for the purposes of CE marking ISO 13485 + Submission of technical documentation for review Dependent on the device risk and scope Additional processes for Class D devices, Companion diagnostics 34

Annex X & XI Type Examination & Production QA 35

Conformity assessment A B C D EU Declaration of Conformity Annex III Quality Management System Assurance Annex IX Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Quality Management System Assurance Annex IX Type Examination Annex X (includes Documentation) Assessment of Documentation per category device - Annex IX 4.4-4.8 Assessment of Documentation per generic device - Annex IX 4.4-4.8 Production Quality Assurance Annex XI Assessment of Documentation Annex IX Ch II Production Quality Assurance Annex XI For Companion Diagnostics CA consultation Annex IX 5.2 For Companion Diagnostics CA consultation Annex X 3 Verification by EU Reference Laboratory Verification by EU Reference Laboratory 37

Annex X and Annex XI Type Examination Certification that a device (inc technical documentation and sample) fulfils requirements Certificate issued for specific device; the type Tests to verify conformity of the Type All changes that affect conformity to general requirements must be assessed EU Reference Lab verification for Class D devices Production Quality Assurance Audit of the QMS to manufacture the specified device Type Cross reference to Annex IX Certificate issued for manufacture of specified device Changes to the QMS may need reassessment (as per Annex IX) EU Reference Lab verification of manufactured batches for Class D devices 38