Electromotoric actuators

Similar documents
Electromotoric actuators

Electromotoric actuators

Electrical actuators

Electrical Actuators

Electrical Actuators

Electromotoric actuators

Electromotoric actuators

Electrical Actuators

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Electromotoric actuator

Electromotive actuators for combi valves

Electromotoric actuators

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Electromotoric actuators for stroke valves

Rotary version, three-position control

TXM1.8RB. TX-I/O Blinds module

Rotary actuators for ball valves

Power supply module, bus connection module

Radiator Lockshield Valves ADN.. AEN..

Air damper actuators

Overview of types. Technical data

Immersion Temperature Sensors

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

RF adapter plugs, dimming

Room unit with PPS2 interface

Heating Circuit Controller

Resistance measuring module

ERF910. RF Repeater. Synco living

Products no longer available

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Digital input modules

Products no longer available

Extension module for lighting control

Heating Circuit Controller

Room unit with PPS2 interface

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Room unit with PPS2 interface

Super universal modules

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

BACnet/IP Web Interface

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Room unit with PPS2 interface

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Room Temperature Controller

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Communication module to connect M-bus devices to POL6xx.xxx controllers.

VAV compact controller

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Universal Controller

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

VAV modular controller

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Non-communicating room controllers

Interface converter for VAV compact controllers

Fast running actuators for air dampers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

AEW Pulse Adapter. Building Technologies

Actuators AMV 655, 658 and 659 can be controlled by electronic controllers with 3-point output.

Room Temperature Controller

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Web interface BACnet/IP

Modulating controlled actuator AME 11

Handheld Tool for VAV compact and modular controllers

AVM 321, 322: Valve actuator

Semi flush-mounted room temperature controllers with LCD

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

Rotary actuator for ball valves KNX / PL-Link

Actuators for three point control AMV 655 without safety function AMV 658 SU, AMV 658 SD with safety function (spring up/down)

RТTH DUAL ROOM SWITCH

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Actuators for modulating control AME 13SU, AME 23SU - safety function (spring up)

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Semi flush-mounted room temperature controllers with LCD

Room Temperature Controllers

Airflow Pressure Sensor

Island bus expansion module

Actuators AME 655, 658 and 659 can be controlled by electronic controllers with modulating or 3-point control output.

Product and functional description

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Actuators for modulating control AME 55, AME 56

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Air Damper Actuators Modbus RTU

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Transcription:

4 861 ACVATIX Electromotoric actuators for Combi-valve types VPI45.., DN15 32 SSD31.. SSD81.. SSD61.. SSD31.. operating voltage AC 230 V 3-position control signal SSD81.. operating voltage AC 24 V 3-position control signal SSD61.. operating voltage AC/DC 24 V DC 0 10 V control signal SSD61EP equal-percentage valve characteristic SSD61.2 operating voltage AC/DC 24 V DC 2 10 V control signal Nominal force > 250 N Automatic identification of valve stroke Direct mounting with union nut, no tools required Basic types complete with plug-in connecting cable, length Optional cable types cable length, 2.5 m and 4.5 m halogen-free cables Manual override and position indication Parallel connection of multiple actuators possible Use For operation of Siemens valves VPI45.. for water-side control of hot and cooling water in heating, ventilation and air conditioning systems. CA1N4861en_02 Building Technologies

Type summary Standard versions Type reference Operating voltage Positioning time at 50 Hz Control signal SSD31 SSD31/00 1) AC 230 V SSD81 SSD81/00 1) AC 24 V 150 s 3-position SSD61 SSD61/00 1) DC 0 10 V SSD61EP 2) AC / DC 24 V 75 s SSD61EP/00 2) SSD61.2 SSD61.2/00 DC 2 10 V Connecting cable 1) 2) Available cable lengths or terminal block connectors refer to "Accessories", page 2 Equal-percentage valve characteristics SSD61.. are UL and cul approved. Accessories Type reference Description Operating voltage Control signal AS3L15 Connecting cable AS3L25 Connecting cable 2.5 m AC 230 V 3-position AS3L45 Connecting cable 4.5 m AS6L15 Connecting cable AS6L25 Connecting cable 2.5 m AS6L45 Connecting cable 4.5 m AC / DC 24 V DC 0 10 V AS6L45HF Connecting cable 4.5 m, halogen-free, VDE 0207-24 AS8L15 Connecting cable AS8L25 Connecting cable 2.5 m AS8L25B Connecting cable 2.5 m with Batigyr connector AC 24 V 3-position AS8L45 Connecting cable 4.5 m AS8L45HF Connecting cable 4.5 m, halogen-free, VDE 0207-24 AS98 Retaining screw for terminal block connectors AS99 Terminal block connector for 3-position actuator SSD81/00 (AC 24 V) AS100 Terminal block connector for DC 0 10 V modulating actuators SSD61/00 Ordering Example: Type Stock no. Description Quantity SSD81/00 SSD81/00 Electromotoric actuator 2 AS99 AS99 Terminal block 2 Delivery Actuators, valves and accessories are packed separately. Items are supplied individually packed. Rev.-No. Overview tables, see page 8. Equipment combinations Type reference DN Actuators Valve type Stroke V PN class Data sheet 100 [mm] [l/h] VPI45.. Combi valves DN15 32 SSD.. 5 75 3000 N4853 VPI45..Q Combi valves with P/T plugs PN25 VPI45.. Combi valves DN40, DN50 SQD.. 6.5 2300 8500 N4540 VPI45..Q Combi valves with P/T plugs 2/9 V 100 = volumetric flow, in l/h, through the fully open valve (H 100)

Function / mechanical design When the actuator is driven by DC 0 10 V control voltage or by a 3-position signal, it produces a stroke which is transmitted to the valve stem. The description of operation in this document applies to the valve versions which are fully closed when de-energized (NC valves). 3-position control signal SSD31../SSD81.. Voltage at 1: Stem extends Valve opens Voltage at 2: Stem retracts Valve closes No voltage at 1 and 2: Actuator maintains its current position DC 0...10 V control signal SSD61, SSD61/00 The valve opens / closes in proportion to the control signal at. At DC 0 V, the valve is fully closed (A AB). When power supply is removed, the actuator maintains its current position. 1) Actuator is calibrated to 5 mm stroke of VPI45.. Stroke 5 mm (calibrated) 1) 5 4 3 2 1 0 0 2 4 6 8 10 control signal [V] DC 2...10 V control signal SSD61.2, SSD61.2/00 The valve opens / closes in proportion to the control signal at. At DC 2 V, the valve is fully closed (A AB). When power supply is removed, the actuator maintains its current position. 1) Actuator is calibrated to 5 mm stroke of VPI45.. Stroke 5 mm (calibrated) 1) 5 4 3 2 1 0 0 2 4 6 8 10 control signal [V] DC 0...10 V control signal SSD61EP, SSD61EP/00 Combi valves VPI45.., DN15 32 in combination with SSD61EP.. have an equalpercentage characteristics. The valve opens / closes in proportion to the 5 control signal at. 4 At DC 0 V, the valve is fully closed (A AB). When power supply is removed, the actuator 3 maintains its current position. 2 1) Actuator is calibrated to 5 mm stroke of VPI45.. Stroke 5 mm (calibrated) 1) 1 0 0 2 4 6 8 10 control signal [V] Features and benefits 3/9

Plastic housing Locking-proof, maintenance-free gear train Manual override with hexagonal socket wrench 3 mm Reduced power consumption in the holding positions Load-dependent switch-off in the event of overload and in stroke end positions Parallel operation of 6 SSD31.., 24 SSD81.. and 10 SSD61.. possible, provided the controllers output is sufficient Terminal block connectors for custom made cables available (only for use with AC 24 V and AC/DC 24 V actuators) Connecting cables with AC 24 V and AC 230 V connectors cannot be mixed up Halogen-free cables available 4891Z19 Accessories Retaining screw AS98 4864Z02 Type AS98 to secure the cable connector 4891Z05 2 3 4 1 The cable connector snaps into position, but can be additionally secured with the retaining screw. Terminal block connectors AS99 AS100 4864Z04 For special cable lengths of the AC 24 V and AC/DC 24 V actuators. Type AS99 for 3-position actuators SSD81/00 Type AS100 for DC 0/2 10 V modulating actuators SSD61../00 The terminal block connectors are supplied complete with Mounting Instructions (74 319 0385 0). Notes Engineering The actuators must be electrically connected in accordance with local regulations (refer to "Connection diagrams"), page 8. Caution Regulations and requirements to ensure the safety of people and property must be observed at all times! The permissible temperatures (refer to "Technical data", page 6) must be observed. The connecting cable of the actuator may come into contact with the hot valve body, provided the temperature of the valve body does not exceed 80 C. Mounting The Mounting Instructions 4 319 0644 0 are enclosed in the product packaging. Assembly is made with the union nut; no tools or adjustments are required. The actuator must be fitted in position 0 (also refer to "Manual override", page 5) without operating voltage. In the case of actuators without connecting cable (SSD../00), the separately ordered terminal block connector and connecting cable must be fitted. 4/9

Orientation Installation 4.5...5 mm Crimp ferrule on stripped wire of connecting cable. 4891Z33 6 mm 26 mm Commissioning Self-calibration Caution Note: Correct calibration is only possible with valve stroke > m Manual override Note When commissioning, check wiring and the functioning of the actuator. Actuator stem extends (from position 0 to 1): Valve opens Actuator stem retracts (from position 1 to 0): Valve closes During commissioning and whenever the operating voltage is switched on, 100 % the SSD61.. runs a self-calibration routine. (Valve stroke 0 Max. stroke Setpoint). t Never intervene manually in this 0 % 75 s process. Power ON The second or third attempt at calibration occurs automatically after an 8-minute delay. After three failed calibration attempts the actuator stem remains in the extended position and the VPI45.. valves are opened. For valves with strokes < m, the actuator/valve combination locks after three failed calibration attempts. A 3 mm hexagonal socket wrench can be used to move the actuator to any position between 0 and 1. If a control signal from the controller is present, then this takes priority in determining the position. To retain the manually set position, unplug the connecting cable or switch off power and the control signal. 4891Z21 3 mm 3 mm 0 1 0 1 4891Z13 Position indicator in position 0: Valve closed 4891Z14 Position indicator in position 1: Valve open Maintenance! The actuators are maintenance-free. When carrying out service work on the plant, following must be noted: Turn power off (e.g. remove the plug) If necessary, disconnect electrical connections from the terminals The actuator must be commissioned only with a correctly mounted valve in place! 5/9

Repair Disposal SSD.. actuators cannot be repaired; the complete unit must be replaced. Broken connecting cables can be replaced, see "Accessories", page 2. The device must not be disposed of together with domestic waste. This applies in particular to the PCB. Legislation may demand special handling of certain components, or it may be sensible from an ecological point of view. Current local legislation must be observed. Warranty The technical data given for these applications is valid only when the actuators are used with the Siemens valves listed under "Equipment combinations", page 2. The use of the SSD.. actuators in conjunction with third-party valves invalidates any warranty offered by Siemens Switzerland Ltd / HVAC Products. Technical data Power supply Operating voltage Voltage tolerance Rated frequency SSD31.. SSD81.. SSD61.. AC 230 V AC 24 V AC 24 V or DC 24 V ± 15 % ± 20 % ± 20 % ± 25 % 50 / 60 Hz Max. power consumption 6 VA 0.8 VA 2.5 VA Fuse for incoming cable 2 A, quickblow Control Control signal 1) 3-position SSD61.. DC 0...10 V SSD61.2.. DC 2 10 V Input impedance for DC 0/2...10 V > 100 kω Positioning accuracy for DC 0/2...10 V < 2 % of nominal stroke Parallel operation (number of actuators) 2) max. 6 max. 24 max. 10 Functional data Run time for 5.5 mm stroke at 50 Hz 150 s 75 s Nominal stroke 5.5 mm Nominal force > 250 N Perm. temperature of medium in the connected valve 1...110 C Electrical connections Connecting cable of basic types 3-core to EN 60320 / IEC 60227 Standards AS 99, AS100 AS3L.. AS6L.., AS8L.. cable diameter wire cross section wire cross section wire cross section < 5 mm 0.5 0.75 mm 2 0,75 mm 2 0,5 mm 2 Meets requirements for CE marking: EMC directive 2004/108/EC Immunity EN 61000-6-2 Industrial 3) Emission EN 61000-6-3 Residential Low voltage directive 2006/95/EC Electrical safety EN 60730-1 Protection class to EN 60730 II III Contamination level EN 60730, Class 2 Housing protection Upright to horizontal IP40 to EN 60529 UL approbation UL 873 cul approbation C22.2 No. 24-93 1) 2) 3) SSD61EP.. in combination with combi valves VPI45.., DN15 32: Equal-percentage valve characteristics Provided the controllers output is sufficient Transformer 160 VA (e.g. Siemens 4AM3842-4TN00-0EA0) for AC 24 V actuators 6/9

SSD31.. SSD81.. SSD61.. Environmental compatibility ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) RL 2002/95/EG (RoHS) Dimensions / weight Dimensions refer to "Dimensions", page 9 Coupling thread to valve union nut M30xm Weight 0.35 kg Housing colors Base and cover RAL 7035 light gray General ambient conditions Operation EN 60721-3-3 Transport EN 60721-3-2 Storage EN 60721-3-1 Environmental conditions Class 3K3 Class 2K3 Class 1K3 Temperature +1...+50 C 25...+70 C 5...+50 C Humidity 5...85 % r.h. < 95 % r.h. 5...95 % r.h. Connecting cable AS3L.. with SSD31.. AS8L.. with SSD81.. 7 White 2 Control signal OPEN (AC 230 V) 6 Black 1 Control signal CLOSE (AC 230 V) 4 Blue N Neutral L = 1,5 m, 2,5 m, or 4,5 m 7 Orange 2 Control signal OPEN (AC 240 V) 6 Violet 1 Control signal CLOSE (AC 240 V) 1 Red N System potential AC 24 V AS6L.. with SSD61.. L = 1,5 m, 2,5 m, or 4,5 m 8 Grey Control signal DC 0/2...10 V 2 Black G0 System neutral (- DC 24 V) 1 Red G System potential AC 24 V (+ DC 24 V) L = 1,5 m, 2,5 m, or 4,5 m Connection terminals AS99 for SSD81.. 2 1 G 4864Z15 Control signal CLOSE Control signal OPEN System potential AC 24 V 4891Z32 AS100 for SSD61.. G0 G 4891Z31 4864Z16 System neutral Control signal DC 0/2...10 V System potential AC/DC 24 V 7/9

Connection diagrams SSD31.. L AC 230 V (N) 2AF (L) Q1 Q2 (1) (2) 1 2 N 4864A01 N Controller Actuator L System potential AC 230 V N System neutral 1, 2 Control signal OPEN, CLOSE Q1, Q2 Controller contacts N N SSD81.. SP AC 24 V 2AF (G) Q1 (G0) (1) 1 2 Q2 (2) N 4864A02 N Controller Actuator SP, G System potential AC 24 V SN, G0 System neutral 1, 2 Control signal OPEN, CLOSE Q1, Q2 Controller contacts G SN SSD61.. SP (+) AC 24 V (DC 24 V) (G) () (G0) N 4864A03 2AF N Controller Actuator SP, G System potential AC/DC 24 V SN, G0 System neutral Control signal G G0 SN (-) 8/9

Dimensions All dimensions in mm Actuator SSD31.. SSD81.. SSD61.. 81.4 72.5 48 M30 9 83 4891M01 Revision numbers Type reference Valid from Rev.-No. Type reference Valid from Rev.-No. SSD31..J SSD61/00..J SSD31/00..J SSD61EP..J SSD81..J SSD61EP/00..J SSD81/00..J SSD61.2..J SSD61..J SSD61.2/00..J Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2005-2016 Technical specifications and availability subject to change without notice. 9/9