PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Similar documents
PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

BVS 16 ATEX E088 X, IECEx BVS X. Operating Instructions

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Type Quickstart

Type ME43. Quickstart

Type Quickstart (from device Version 2)

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

SolConeX extra-low voltage flange socket

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Type Operating Instructions - Software. Bedienungsanleitung - Software Manuel d utilisation - Logiciel

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Operating instructions

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

MANUAL LML-P, LML-S, LML-Ex

Operating instructions. Switching amplifier DN0210 DN / / 2015

SolConeX Wall-Mounted Socket, 16 A

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor NI3-EG08K-Y1-H1341

Operating Instructions

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

PHOENIX CONTACT - 01/2008

MANUAL Surge Protectors

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor BI1.5-EG08-Y1-H1341

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

PHOENIX CONTACT - 05/2007

CPCI-PS24 24V-Power Supply

Material pressure (bar) (Cv (US) kv x 1,2 Seat

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 02/2008

Flow. Flow. N/en

Operating pressure (bar) kv factor (m 3 /h) *3)

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Operating Instructions

Installation Instruction. HART Add-On Module

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Inductive sensor BI1.5-EG08-Y1-H1341

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

B63/ NS MS. EtherNet/IP LINK

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Operating instructions. Speed monitor D / / 2014

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Zener Barriers Bulletin 937Z

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Installation manual plugs and connectors with screw connection (16/32 A)

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

TG basic 1. Appliance tester for testing protective measures in accordance with DIN VDE (DIN EN 62638)

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

MACX MCR-EX-SD LP(-SP)

Operating Instructions

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

GRP Flameproof Visual Signal Xenon or Steady LED

MINI MCR-SL-CVS NC

Pneumatic Control/Feedback

MDM 011-Z1 Regen Resistor

NXT4 Three phase meter for commercial, industrial and advanced residential applications

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Product manual plug, sockets and coupler 16 A.- Z0251

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Electronic Temperature Controller. Instruction Manual Version

DR7100 SERIES Supplementary instructions

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Pneumatic Control/Feedback

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Type Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

IECEx Certificate of Conformity

Metal Position Switch

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

FLEX Ex Spring Clamp Terminal Base

Type Control Head. Operating Instructions

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Inductive sensor BI5-EM18-Y1X-H1141

M E M O R A N D U M I.S.

MANUAL Functional Safety

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Transcription:

Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation

We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert Werke GmbH & Co. KG, 200-2017 Operating Instructions 1706/1 _EU-EN_0080 / Original DE

Contens: 1 OPERATING INSTRUCTIONS...4 1.1 Symbols... 4 2 AUTHORIZED USE...5 2.1 Restrictions... 5 2.2 EX approval... 5 3 BASIC SAFETY INSTRUCTIONS...6 4 GENERAL INFORMATION...7 4.1 Contact addresses... 7 4.2 Warranty... 7 4.3 Information on the Internet... 7 5 APPLICATION CONDITIONS OF THE DEVICES...7 5.1 Individual assembly, block assembly... 7 5.2 Operating temperature range... 7 6 TECHNICAL DATA...8 6.1 Conformity... 8 6.2 Standards... 8 6.3 Licences... 8 6.4 Operating conditions... 8 6.5 Electrical data... 9 7 INSTALLATION...12 7.1 Safety instructions...12 7.2 Installation of Type 6106...13 7.3 Types of connection...13 8 MAINTENANCE, TROUBLESHOOTING...13 8.1 Safety instructions...13 8.2 Maintenance work...13 8.3 Troubleshooting...13 9 TRANSPORT, STORAGE, DISPOSAL...14 3

Operating instructions 1 OPERATING INSTRUCTIONS The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. The operating instructions contain important safety information! Failure to observe these instructions may result in hazardous situations. The operating instructions must be read and understood. CAUTION! Warns of a possible danger! Failure to observe this warning may result in a medium or minor injury. NOTE! Warns of damage to property! Failure to observe the warning may result in damage to the device or the equipment. 1.1 Symbols DANGER! Warns of an immediate danger! Failure to observe the warning may result in a fatal or serious injury. WARNING! Indicates important additional information, tips and recommendations. Refers to information in these operating instructions or in other documentation. designates a procedure which you must carry out. Warns of a potentially dangerous situation! Failure to observe the warning may result in serious injuries or death. 4

Authorized use 2 AUTHORIZED USE Unauthorized use of the device Type 6106 may be dangerous to people, nearby equipment and the environment. The device is used exclusively as a solenoid valve for media permitted according to data sheet and for use in Group II Category 2 G and temperature class T4, T5 or T6 (see specifications on the approval plate). The applied protection class is the intrinsic safety EX i for coils with circular plug connection, rectangular plug connection with or without protective collar as well as connection by pressed-in single wires and device socket connection in accordance with DIN 43650 Form C. The faultless and reliable operation of the system assumes correct transportation, correct storage and installation as well as careful operation and maintenance. Any other use is regarded as unauthorized. Bürkert is not liable for any resulting damage. The user alone bears the risk. Only use the device for its intended purpose. 2.1 Restrictions If exporting the system/device, observe any existing restrictions. 2.2 EX approval The EX approval is only valid if the modules and components authorized by Bürkert are used as described in these operating instructions. Type 6106 may be used only in combination with the additional components released by Bürkert, otherwise the EX approval will be voided! If any unauthorized changes are made to the device, modules or components, the EX approval will also be voided. 5

Basic safety instructions 3 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any Contingencies and events which may arise during the installation, operation and maintenance of the devices. Local safety regulations the operator is responsible for observing these regulations, also with reference to the installation personnel. Danger of explosion! The device is a closed system and must not be modified in any way. A device which has already been used in a non-hazardous i circuit must no longer be used in the hazardous i circuit, as safety cannot be guaranteed. Use the device in the hazardous i circuit only. Devices which were used in a non-hazardous i circuit must be identified after they have been removed, denoting that their use is prohibited in the hazardous i circuit. Danger high pressure! When reaching into the system, there is an acute risk of injury. Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines. During the installation, make certain the flow direction is correct. Observe applicable accident prevention and safety regulations for pressurized devices. Danger of explosion caused by electrostatic charge! If there is a sudden discharge from electrostatically charged devices or persons, there is a danger of explosion in the EX area. Using suitable measures, ensure that no electrostatic charges can occur in the EX area. Clean the device surface by gently wiping it with a damp or antistatic cloth only. General Hazardous Situations. To prevent injuries: Ensure that the system cannot be activated unintentionally. Installation and maintenance work may be carried out only by authorized technicians with the appropriate tools. After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner. The device may be operated only when in perfect condition and in consideration of the operating instructions. The general rules of technology must be observed for application planning and operation of the device. Failure to observe this operating manual and its operating instructions as well as unauthorized tampering with the device release us from any liability and also invalidate the warranty covering the devices and accessories! 6

General information 4 GENERAL INFORMATION 4.1 Contact addresses Germany Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10 91 111 Fax + 49 (0) 7940-10 91 448 E-mail: info@de.buerkert.com 5 APPLICATION CONDITIONS OF THE DEVICES 5.1 Individual assembly, block assembly The solenoid coils type AC21 are suitable for individual assembly and for block assembly. 5.2 Operating temperature range For each type observe the operating temperature range specified in the Electrical Data. International Contact addresses can be found on the final pages of the printed operating instructions. And also on the Internet at: www.burkert.com 4.2 Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions. 4.3 Information on the Internet The operating instructions and data sheets for Type 6106 can be found on the Internet at: www.burkert.com 7

Technical data 6 TECHNICAL DATA 6.1 Conformity The device conforms to the EC directives according to the EC Declaration of Conformity. 6.2 Standards The conformity with EC guidelines is guaranteed in accordance with standards: EN 60079-0, EN 60079-11 6.3 Licences The EC type-examination certificate PTB 01 ATEX 2175 was issued by the PTB (Physikalisch Technische Bundesanstalt) Bundesallee 100 38116 Braunschweig which also audits production (CE 102). The EC type-examination certificate can be found on the Internet at: www.burkert.com 6.4 Operating conditions WARNING! Danger of explosion! It is highly risky to exceed the technical data indicated on the rating plate! Never exceed the technical data indicated on the rating plate. Rating plate Fig. 1: Location of the rating plate 8

Technical data 6.4.1 Rating plate IEC EX - Approval number Made in Germany EX designation, Temperature class PTB approval number PTB 01 ATEX 2175 II 2 G Ex ia IIC T6 IEC Ex PTB 06.0102 Ex ia IIC T6 AC21 P, U, I see manual S/N XXXXX CE0102 XXXXXXX W2YLT Serial number of the coil, CE identification, Identification number of the coil Voltage (± 10 %), Power (see operating instructions) EX designation 6.5 Electrical data 6.5.1 Coil dimensions Length (mm) Width (mm) Height (mm) Mass (g) Electrical connection 27 15.5 34 42 ohne Angaben 27 15.5 28 39 JF80 Approval code: PD88 PD39 PE92 Electrical connection: Ex ia II C T6 Ex ia II C T5 Ex ia II C T4 JC09 Pressed-in single wires 0.2 mm2 (AWG 24) JF79 Circular plug connection M8, 3-pole JF80 Rectangular plug connection, 2-pole JF82 Rectangular plug connection, 2-pole without protective collar Not specified Appliance socket connection in accordance with DIN 43650 form C Fig. 2: Description of the rating plate 9

Technical data 6.5.2 Use in temperature class T6 Ignition protection type Ex ia, Gas group II C Temperature class T6 Max. permitted ambient temperature [ C] -40... +60 Assembly Max. permitted power consumption [W] 0.4-40... +55 0.5-40... +50 Block assembly 0.7-40... +45 0.9-40... +40 1.1-40... +60 0.7-40... +55 Individual 0.9-40... +50 1.1 The maximum permitted power depends on the max. ambient temperature, the temperature class and the installation. 6.5.3 Use in temperature class T5 Ignition protection type Ex ia, Gas group II C Temperature class T5 Max. permitted ambient temperature [ C] -40... +75 Assembly Max. permitted power consumption [W] 0.4-40... +70 0.5-40... +65 Block assembly 0.7-40... +60 0.9-40... +55 1.1-40... +75 0.7-40... +70 Individual 0.9-40... +65 1.1 6.5.4 Use in temperature class T4 Ignition protection type Ex ia, Gas group II C Temperature class Max. permitted ambient temperature [ C] Assembly T4-40... +100 Block assembly Max. permitted power consumption [W] 0.7 10

Technical data 6.5.5 Safety data Group: Ignition protection type: Temperature class: Max. permitted input voltage (U i ): Max. permitted input current (I i ): Inductance (L i ): ~ 0 Capacity (C i ): ~ 0 II C Ex ia T4, T5 or T6 35 V 0.9 A The maximum permitted voltages and the associated shortcircuit currents can be found in Table A1 in the standard EN 60079-11 for the corresponding gas group. Version Version which uses 300 Ω supply module High-resistance version Version for Type 8650 Resistance R20 [Ω] Minimum clamping voltage [V] Minimum current [ma] Type 320 9.3 29 EX I / 21 475 10.9 23 EX I / 22 125 6.1 49 EX I / 23 Ignition protection type Ex ia II C: Coil Type AC21 (example): U i 15 18 20 22 25 28 30 35 I i 0.9 0.44 0.309 0.224 0.158 0.12 0.101 0.073 The coils of type AC21 are available in two versions: Version for use with 300 Ω supply module (300 Ω barrier), High-resistance version for use with other authorized supply modules (e.g. 8 x remote I/O from Stahl). The maximum voltage and current values are specified by the permitted electrical equipment. 6.5.6 Permitted ambient temperature The maximum permitted ambient temperature depends on the power fed in, the temperature class and the installation. For the appropriate values see chapters 6.5.2 6.5.3 and 6.5.4. 11

Installation 6.5.7 Protection class Electrical connection Protection class without matching plug connector with matching plug connector Appliance socket connection in accordance with DIN 43650 form C IP20 IP65 Circular plug connection M8, 3-pole 2 pressed-in single wires 0.2 mm 2 (AWG 24) Rectangular plug connection, 2-pole Rectangular plug connection, 2-pole without protective collar IP65 - IP20 IP20 7 INSTALLATION 7.1 Safety instructions DANGER! Danger of explosion! The device is a closed system. It must not be removed. Risk of electric shock! Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation! Live terminals in the terminal box may cause an electric shock, short-circuit or explosion. Switch off the power supply. Only then open the terminal box. The connection lines of the electromagnets must be permanently installed in such a way that they are adequately protected from mechanical damage. Observe applicable accident prevention and safety regulations for electrical equipment! WARNING! Danger high pressure! When reaching into the system, there is an acute risk of injury. Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines. During the installation, make certain the flow direction is correct. Observe applicable accident prevention and safety regulations for pressurized devices. 12

Maintenance, Troubleshooting 7.2 Installation of Type 6106 Any installation position. Preferably with magnet system face up. 1. Clean pipelines. 2. Any installation position Preferential direction with actuator face up. 3. Connect dirt trap upstream Observe direction of flow! 4. Fluidic connection. 5. Install - Always connect protective conductor! 7.3 Types of connection Rectangular connector with or without protective collar Appliance socket connection face up in accordance with DIN 43650 2 single wires Circular Form C connector 8 MAINTENANCE, TROUBLESHOOTING 8.1 Safety instructions WARNING! Danger of explosion caused by electrostatic charge! If there is a sudden discharge from electrostatically charged devices or persons, there is a danger of explosion in the EX area. Using suitable measures, ensure that no electrostatic charges can occur in the EX area. Clean the device surface by gently wiping it with a damp or antistatic cloth only. Risk of injury from improper servicing, repairs and maintenance! The device may be serviced and maintained by authorized technicians only and with the appropriate tools! The unit may be repaired by the manufacturer only! 8.2 Maintenance work The devices are maintenance-free when operated under the conditions described in this manual. 13

Transport, Storage, Disposal 8.3 Troubleshooting If malfunctions occur, ensure that: the device has been installed correctly, the device is not damaged, all screws have been tightened, the polarity is correct (to ensure proper function, the appropriate connection on the connector terminal is marked with + ), the pipelines are free. 9 TRANSPORT, STORAGE, DISPOSAL NOTE! Transport damages! Inadequately protected equipment may be damaged during transport. During transportation protect the device against wet and dirt in shock-resistant packaging. Avoid exceeding or dropping below the allowable storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature: -40 +55 C. Damage to the environment caused by device components contaminated with media. Ensure the device and packaging are disposed of in an environmentally sound manner. Observe applicable regulations relating to refuse disposal and the environment. 14

www.burkert.com