LDS - LDS PLUS SINGLE READING DIGITAL SYSTEM. DELAY Programmable delay at dosing start-up (up to 60 minutes).

Similar documents
LD MULTICHANNEL - LD MULTICHANNEL PLUS

EL300. Multi-Channel Water Controller. Specialist Of UV Spectroscopy

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

Control and automatic dosing

*suitable both for membrane sensors or chlorine open cell

Range. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable

Neon pr. ph/ ORP measurement. Applications. Description

LDCL DIGITAL CONTROLLER OPERATING MANUAL

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

Electronic Dosing Systems Ltd

world class water monitoring series 42

Control instruments GUARDIAN 2 - GUARDIAN 3

GEN II Wireless GSM/GPRS Data Acquisition System

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

UNIVERSAL SMART INSTRUMENT. Intelligent Flow, Level and Water Quality Monitoring

WebMaster WIND. Industrial Water Controller OVERVIEW SUMMARY OF KEY BENEFITS

Industrial Water Treatment Controllers

Double-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional

mxcontrol Multifunction Controller

FEATURES DESCRIPTION FEATURES

Digital Panel Meters

DOSING EQUIPMENT CATALOGUE

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

BMS Steam Station Solutions

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

WebMaster. Cooling Tower/Boiler Controller. ONE simple and flexible controller for ALL your water treatment needs! SUMMARY OF KEY FEATURES

ezeio Controller and the 2400-A16 input expansion.

Solutions to the Most Challenging Environments

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Please enter the identity code of your device here!

DS 500 Intelligent chart recorder for compressed air and gases

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

SYCLOPE INDIG O controller for semi publics swimming pools (Part 2) Programming instructions. References : CEN0000, CEN0001 and CEN0005 Rev : 3

Aquaculture CONTINUOUS MONITORING AND CONTROL

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

Eurotherm advanced controllers providing solutions for simple to demanding applications...

Modbus Signal Output Adapter Quick Start Guide

APP 700 Technical Specification

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

ECOWISE EM100 THE MULTI-FUNCTIONAL DEVICE SERVER

GRYF. Measuring Instruments. For Fisheries. Practice and research

Server/ Engineering Station. Filed Instrument. Filed Instrument. Filed Instrument. Switches. Fig1: Scheme for micro PLC to Master PLC Interface

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

About Suntex. Online Measurement and Control. Portable and Laboratory Instruments. ISO 9001: 2000 Certificated since 2001

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

Aqua TROLL 600 Multiparameter Sonde

LDCL DIGITAL CONTROLLER O P E R A T I N G M A N U A L

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Please enter the identity code of your device here!

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

Clamp-On Digital Multimeters

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

DMT345 and DMT346 Dewpoint Transmitters

GENERAL SAFETY GUIDELINES

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

IDS 500 mobile Intelligent mobile chart recorder

ATU800. Technical specification

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

VersaMax Micro and Nano Technical Product Presentation

Operation Manual 0/4-20mA Input and Temperature Transmitter

THE RAINBOW SCADA D-500-LITE

1 PoolManager 5 Software Releases Overview

Global Water globalw.com. Global Water. Instrumentation, Inc.

mark150s mark150/485s DDC controllers Summary

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

HIGH PERFORMANCE STEPPER DRIVES

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

AirCare Partners With IntelliCom

Summary of Features and Benefits

MMT330 Series Moisture and Temperature Transmitters for Oil

Manual. MegaTron Controller Supplemental. Modbus / TCP Communications Manual

SECTION Multi-Parameter Analyzer Transmitter

Datalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

WebMaster. Cooling Tower/Boiler Controller. ONE simple and flexible controller for ALL your water treatment needs! SUMMARY OF KEY FEATURES

Catalogue for measuring professionals

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Thermocouple Signal Conditioners

MXD70 SERIES. Instrumentation to meet your Process Requirements. Features.

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

Communication Interface

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Jazz-J. Jazz. Features:

Data Manager Installation Guide

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

About Suntex. Online Measurement and Control. Portable and Laboratory Instruments

Transcription:

Digital controllers for measurement and control of a single parameter, with temperature reading ( C or F). An accurate design has allowed to build on a series of instrument easy to program. LDS and LDS PLUS series are controlled by an ENCODER. Working mode can be set: on / off pulse proportional proportional PWM fixed PWM PID (only on LDS PLUS). Instruments connected in a network (up to 3 instruments) can be remotely controlled. Combined with probes and probe holders, they can be assembled on panels to have a complete turnkey control system. REMOTE CONTROL Remote control is available with ETHERNET or GSM/ GPRS configurations. Remote control via: www.ermes-server.com. SOFTWARE English and French software available. Ask for Deutsch. CUSTOMIZATION Instruments can be customized with client logo on frontal panel. STAND-BY AND FLOW CONTROL PERMANENT DATA STORAGE (WITHOUT BATTERY) System log on display. AUTOMATIC With PT00 temperature probe. DELAY Programmable delay at dosing start-up (up to 60 minutes). ALARMS Alarms for: damaged probe; max dosage, flow, threshold, level (double level on LDS PLUS). DISPLAY Probe readings, alarms notification, network status (Ethernet; USB, GSM/GPRS) are shown on display. PROBE READOUT MENU ma As option. ONLY FOR LDS PLUS PROBE CLEANING To obtain reliable results it is possible to connect a cleaning system, for example a probe cleaning system. CIRCULATION PUMP This function allows to supply a water circulation pump into the intake pipeline, increasing pressure. MODBUS Modbus is a serial communication protocol for connecting instruments to other devices on RS485 network. ma WATER METER As option. ALARM RELAIS 30 VAC output alarm. DOUBLE SETPOINT Relais set for setpoint.

MODELS STANDARD PLUS PARAMETER LDSPH LDSPH PLUS ph LDSRH LDSRH PLUS ORP LDSCL LDSCL PLUS Chlorine (chlorine measure based on the probe) LDSCD LDSCD PLUS Conductivity LDSCDIND LDSCDIND PLUS Inductive conductivity (ECDINDPT probe) LDSTORBH LDSTORBH PLUS Turbidity (ETORBH probe) LDSDO LDSDO PLUS Dissolved Oxygen (EOLUM probe) LDSTRC LDSTRC PLUS Tracers (ETRC probe) 6 5 4 3 D 95.00 06.00 D C 00.00 40.00 C B B.30 A Progettato da Controllato da Modificato da Data Massimo_F 6/05/03 Materiale: Toll. Gen. 0.05 A 6 5 4 3 Dimensionale_L_Digitale Edizione 00 Foglio /

LDSPH - LDSPH PLUS LDSPH 0-4 ph; resolution: 0,0 ph LDSPH PLUS PT00 SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output ph level ph probe relay output (ph) Opto coupled output (ph) ma output ph level ph probe ma water meter relay output (ph) Opto coupled output (ph) relay output for probe cleaning relay output for circulating pump ma output (ph & Temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

LDSRH - LDSRH PLUS LDSRH 0-000 mv; resolution: 0, ORP LDSRH PLUS / SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output ORP level ORP probe relay output (ORP) Opto coupled output (ORP) ma output ORP level ORP probe ma water meter relay output (mv) opto coupled output (mv) relay output for probe cleaning relay output for circulating pump ma output (mv & Temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

LDSCL - LDSCL PLUS LDSCL Chlorine 0-0 mg/l LDSCL PLUS / SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output Chlorine level Chlorine probe relay output (Cl) Opto coupled output (Cl) ma output Chlorine probe Chlorine level ma water meter relay output (Cl) opto coupled output (Cl) relay output for probe cleaning relay output for circulating pump ma output (Cl & temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

LDSCD - LDSCD PLUS LDSCD LDSCD PLUS Conductivity with temperature reading ( C or F) 0-300,0 µs 0-3000 µs 0-30,00 ms 0-300,0 ms PT00 SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output Conductivity probe relay output (Conductivity and alarm) ma output (Conductivity and temperature) Conductivity probe ma water meter relay output (Conductivity) opto coupled output (Conductivity) relay output for probe cleaning relay output for circulating pump ma output (Conductivity and temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

LDSCD IND - LDSCD IND PLUS LDSCD IND LDSCD IND PLUS Inductive conductivity with temperature reading ( C or F) 0-3000 µs 0-30,00 ms 0-300,0 ms PT00 SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output Sonda conducibilità relay output (Conductivity and alarm) ma output (Conductivity and temperature) Sonda conducibilità ma water meter relay output (Conductivity) opto coupled output (Conductivity) relay output for probe cleaning relay output for circulating pump ma output (Conductivity and temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

LDSTORBH - LDSTORBH PLUS LDSTORBH LDSTORBH PLUS Turbidity with temperature reading ( C or F) 0-9,999 NTU 0-99,99 NTU 0-999,9 NTU 0-9999 NTU PT00 SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output Turbidity probe relay output (NTU and probe cleaning) ma output (NTU and temperature) Turbidity probe ma water meter relay output (NTU) opto coupled output (NTU) relay output for probe cleaning relay output for circulating pump ma output (NTU and temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

LDSDO - LDSDO PLUS LDSDO LDSDO PLUS Dissolved oxygen with temperature reading ( C or F) 0-9,999 mg/l O 0-99,99 mg/l O 0-999,9 mg/l O 0-9999 mg/l O PT00 SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output Dissolved oxygen probe relay output (Dissolved oxygen) ma output (Dissolved oxygen) Dissolved oxygen probe ma water meter relay output (Dissolved oxygen) opto coupled output (Dissolved oxygen) relay output for probe cleaning relay output for circulating pump ma output (Dissolved oxygen & Temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

LDSTRC - LDSTRC PLUS LDSTRC Tracers 0-999.9 ppm; resolution: 0, ppm LDSTRC PLUS / SIGNAL 85-64 VAC; 50/60 Hz 5 W relays; 5A @ 30 VAC (fuse protected) 85-64VAC alarm output Trc level Trc probe relay output (Trc) Opto coupled output (Trc) ma output Trc level Trc probe ma water meter relay output (Trc) opto coupled output (Trc) relay output for probe cleaning relay output for circulating pump ma output (Trc & Temperature) -0 C... 50 C (4 F... F) / 0-95% (non condensing) relative humidity POLLUTION LEVEL,45 kg (3.967 lb) OPTIONS Modbus configuration

CONFIGURATIONS INSTRUMENT Configuration PLUS WHEN REQUIREMENTS FUNCTION BASIC (standard) / For local control only / RS485 output to link other EMEC instruments or a PC ADVAND USB USB output You do not need a PC on your plant: you can download data log on a USB device / RS485 output to link other EMEC instruments or a PC Data Log on USB device ETHERNET LAN network between instrument and web Remote control via WEB ERMES LAN wiring (RJ-45) RS485 output to link other EMEC instruments or a PC Web ERMES remote control (PC, smartphone or tablet) Alarm messages via email GSM/GPRS GPRS modem between instrument and web Remote control via WEB ERMES Network coverage RS485 output to link other EMEC instruments or a PC Web ERMES remote control (PC, smartphone or tablet) Alarm messages via email Alarm messages via SMS MODBUS Connection to other devices (PLC) via RS485 PLC plant management / PLC connection output for reading and modifying parameters