The power line carrier solution for digital transmission grids siemens.com/powerlink-ip

Similar documents
Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

SWT 3000 Teleprotection siemens.com

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Bus Bar Protection Relay B-PRO 4000

VCL-TP, Teleprotection Equipment

FL MC 2000E (SM40) LC

MINER-S Station Controller. Substation Automation

Scout-S Station Controller

UPLC-100. Universal Power Line Carrier. 5C Communications Inc.

MINER-S Station Controller

VCL-TP, Teleprotection Equipment with Trip Counter Display

Connection Master. Datasheet. siemens.com

Communication Gateway COM 610. Product Guide

SEL-2730M 24-Port Managed Ethernet Switch

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Transformer Protection Relay

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

FEATURES DESCRIPTION FEATURES

Type VRLTC tap changer

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

Relion 611 series. 611 series Type Test Certificate

Designed, built, and tested for troublefree operation in extreme conditions

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

Zero-Packet-Loss in the Substation. Marzio P. Pozzuoli RuggedCom Inc. Industrial Strength Networks Woodbridge, Ontario, Canada

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

Features and Benefits

Line Current Differential Protection Using Broadband Power Line Carrier Technology

MULTILINK ML2400 Guideform Specification

DATASHEET. Ultra Capacitor Charger, UCC-4

RT4F-110V/25A RECTIFIER

Rugged MediaConverter

ONT-1GE-W. Brief Views

CONVERGENCE 32XX Series PDH / Ethernet Convergent System

Remote I/O RIO600 Product Guide

Connection Master. Mission critical multiservice access platform for utility, corporate and enterprise customers

RT12-240V/2.4kW Rectifier Specification

ex-s1110-xt Gigabit Ethernet Extenders

TU531, TU532 Terminal Unit

TF501, TF521 Terminal Bases

OP-GONT 91001W. Overview: 1Port Gigabit GPON ONT

OWL630 OUTDOOR ACCESS POINT

16- or 24-port Managed Switching Hubs

SE5908A Series SE5916A Series. 8 or 16-Port IEC Certified Industrial Rack-Mount Secure Serial Device Server FEATURE HIGHLIGHTS

Technical Data TICRO 100

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

Reprint - ABB review 3/2011. Advanced power grid protection Next generation teleprotection solutions

RT4B-110V/12A RECTIFIER

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

RUGGEDCOM RMC8388. Rugged Media Converter. siemens.com/rmc8000. Edition 10/2015. Brochure

Hardened Web-Smart High Power PoE Ethernet Switch

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Table 1 Relay Model and Function

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

Arc protection relay. Features Three-phase overcurrent function. Application

ap 2-w cybox ap 2-w Industrial and Mobile IEEE ac Dual Radio Wireless Access Point

IES DVS-110W02-3SFP Managed Switch. IABG PLC Division

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Technical specifications

Connection Master. Mission critical multiservice access platform for utility, corporate and enterprise customers

CM597 Ethernet Communication Module

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

Industrial Protocol Gateway

8 to 14 ports 10/100Base-TX with up to 2-port 100Base-FX or Gigabit Hardened Managed Ethernet Switches. Overview

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

A more intelligent way to implement VoIP in remote offices and SOHO environments

TM221CE40R controller M IO relay Ethernet

Moxa White Paper. Requirements for Ethernet Networks in Substation Automation. Certification and Hardware Requirements. Alvis Chen

8 or 12-Port IEC Certified Industrial Managed Gigabit Switch. EHG9508 EHG9512 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

ABB 520BID01 Binary Input datasheet

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Industrial Switches Industrial Switches

AO523 Analog Input Module

Relays for Various Protection Applications / 7SV600

Features and Benefits. Certifications

CopperLink Ethernet Extender

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification

LigoBASE 5-N/ High-performance 5 GHz base-station COPYRIGHT 2017 LIGOWAVE COPYRIGHT 2017 LIGOWAVE

FLEXIBLE WIPS SENSOR SUPPORT

DIN Rail RTU 540CMD01 Data sheet

Stratix 5700 Ethernet Managed Switches

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Integrated Communications Optical Network. Guarantee fast and dependable operation for power protection and mission-critical

Autodaptive Capacitor Control M 2501B

IMC-P111FX / IMC-P111P Series

Providing the missing piece in your Condition Based Monitoring platform

IMC-P111FX Series IMC-P111P Series

Industrial Switches. Industrial switches. Copper cables Fiber optic cables Ring redundancy

IEC /IEEE 1613 Lite L3 Hardened Managed 24-port Gigabit SFP. 10GbE Connectivity Four 10G SFP+ for connecting the switch to the core network

1U Rack Mounting 28-port 100M/Gigabit Layer 2 Managed Electricity Industrial Ethernet Switch

Allen-Bradley 1786-RPFRXL

Power System Simulator The Ultimate Tool for Protection Scheme Testing. The F6150SV Features:

Transcription:

PowerLink IP The power line carrier solution for digital transmission grids siemens.com/powerlink-ip

PowerLink IP New challenges for operators New challenges for operators of high- voltage networks The deregulation of energy markets and rapidly growing decentralized power generation are making the management of power networks more complex. In addition, the rapid growth of network digitalization is leading to an increasing demand for data communication. The new Siemens PowerLink IP provides an attractive and economical solution to these challenges. In traditional high-voltage (HV) substations, applications like binary teleprotection signals, control center commands, and analog voice only need low bit rates. In contrast, the new digital HV substations use packet-based broadband communication infrastructure. In addition, new central data analytics and application services demand extended data bandwidth. PowerLink IP the power line carrier (PLC) solution for digital transmission grids PLC systems utilize the high-voltage line(s) between transformer substations as an economical communication path for data, teleprotection, and voice. Siemens power line carrier technology has been in use for decades and delivers extremely high standards of transmission reliability in network protection (for example, protection signals), safeguards transmission quality, and can be easily integrated into a wide range of communication networks. PowerLink IP was designed for Ethernet/IP environments in the new digital high-voltage substations, making PLC systems more attractive and efficient than ever before. 2

New challenges for operators PowerLink IP PowerLink IP your advantages at a glance PowerLink IP provides proven PLC technology for the extended bandwidth requirements of digital high-voltage substations Data rates of up to 2 Mbps for each transmission direction allow several traditional PLCs to be replaced The core feature is an expanded and more efficient bandwidth utilization The pure packet-based architecture reduces and simplifies installation and commissioning, maintenance effort, and training We offer tailor-made solutions for primary and backup HV substation interconnection PowerLink IP can be seamlessly integrated into existing PLC infrastructure It provides custom migration scenarios for integrating legacy devices Siemens product-related services support a smooth transition along the implementation path PowerLink IP is prepared for future software applications and is maintaining its role as a trendsetter in modern PLC technology now and into the future 3

PowerLink IP Rapid growth of communications Rapid growth in the demand for communication Traditional HV substation limited bandwidth required In traditional HV substations (Figure 1), grid control and remote access are the sole applications. The substation is comprised primarily of a legacy communication infrastructure with serial and analog interfaces such as V.24, X.21, FXS, FXO, and E&M. Most of the data consists of binary teleprotection signals, control center commands, and analog voice. These applications require only narrowband bit rates and, for the most part, no integration into enterprise IT is required. Remote accesss Grid control Wide-area communication HV substation Teleprotection device with binary I/O Distance protection devices with binary I/O Analog phone IEC 101 RTU* Figure 1: Traditional HV substation: limited demand for bandwidth * IEC 60870-5-101 4

Rapid growth of communications PowerLink IP Digital HV substation new applications need additional bandwidth New central data analytics and application services as well as new substation devices like IEC 60870-5-104/IEC 61850 RTU, sensors/actors, PMU, fault/pq recording, CCTV, and VoIP require more WAN bandwidth. These applications need IP and Ethernet as their main broadband communication infrastructure inside (LAN) and outside (WAN) the substation. The data flow is primarily asymmetrical, and cybersecurity is an integral feature. Figure 2 shows a typical digital HV substation. Siemens Remote Service Grid control Grid applications Power quality Wide-area grid monitoring Asset monitoring Video monitoring Physical access Device management Communication network Digital HV substation Ethernet switches IP router (firewall, IDS, VPN) Ethernet switches Station bus Communication LAN S/S controller IEC 104 RTU* PMU Fault recorder PQ recorder Protection devices CCTV IP phone Corporate applications Physical access control Field devices Process bus Ethernet switches Sensor Sensor/actor Sensor/actor Sensor Sensor Transformers Switches Breakers Overhead lines Sensor Figure 2: Digital HV substation: new applications need more bandwidth * IEC 60870-5-104 5

PowerLink IP The PowerLink IP system The PowerLink IP system optimized for Ethernet communication System overview The new PowerLink IP system has a pure packet-based architecture with a softwaredefined modem. It is optimized to fulfill the communication requirements of modern substation devices. Figure 3 shows the system at a glance. The digital modulation board contains an integrated L2 switch and provides six Ethernet interfaces. The LCT interface is intended for local administration, whereas the three electrical and two optical Ethernet interfaces are designed to connect substation devices. System alarms can be displayed via alarm contacts or remote monitoring with the latest SNMP technology. The HV line interface transmits/receives the PLC signal and is connected to the coupling unit. The integrated teleprotection system SWT 3000 provides binary I/O and GOOSE (IEC 61850) interfaces. PowerLink LCT Ethernet interfaces Digital modulation Amplifier iswt Power supply Line tuner and filter Alarm signaling Binary I/O or GOOSE (IEC 61850) HV line interface Figure 3: PowerLink IP: system architecture 6

The PowerLink IP system PowerLink IP Expanded channel bandwidth HV power line carrier systems typically operate in the frequency range up to 500 khz. Traditional HV-PLC systems use bandwidth up to 32 khz per system, providing a data rate up to 320 Kbps. In contrast to traditional PLC systems, PowerLink IP utilizes a frequency band of up to 256 khz, allowing a maximum data rate of up to 2 Mbps 1 per transmission direction (see Figure 4). Thanks to its expanded bandwidth, PowerLink IP can replace several traditional PLC systems. 1 Specific set-up required Traditional PLC: In each transmission directon: preselected, fixed bandwidth from 2 khz to 32 khz 32 khz max 320 Kbps 36 500 f (khz) PowerLink IP: In each transmission directon: variable-channel bandwidth from 8 khz to 256 khz (250-Hz steps) 256 khz max 2 Mbps 36 500 f (khz) Figure 4: PowerLink IP: expanded frequency band 7

PowerLink IP The PowerLink IP system Efficient bandwidth utilization In addition to the expanded frequency band, the completely new, highly efficient bandwidth utilization is a core functionality of the PowerLink IP system. Figure 5 shows the main features notching, channel spreading, and asymmetrical data streams in detail. Notched frequencies Parts of the frequency band of the PowerLink IP system s channel band can be blocked (notched) for example, if they are used by radio services. This feature enables higher data rates, because the PowerLink IP frequency band can be extended beyond the blocked frequencies. Channel spreading If a part of the PowerLink IP frequency band is disturbed, additional frequency bandwidth can be requested from adjacent PowerLink IP systems. Systems that are operating in adjacent channels automatically exchange information about the individual bit rate to be transmitted. The bandwidth that may be utilized by an individual system is adjusted and optimized for all systems operating in the neighboring frequency bands. PowerLink IP adapts the data rate as a function of changes in the noise ratio on the line: for example, changes caused by external disturbances or poor weather conditions. Figure 5 shows an initial bandwidth allocation for two PowerLink IP systems operating in adjacent frequency bands. If system 1 cannot transfer its target bit rate, it will request bandwidth that is currently being utilized by system 2. After an automated negotiation process, system 1 spreads out and extends the utilized frequency band, while at the same time system 2 reduces its bandwidth utilization. This feature ensures maximum data throughput for all PowerLink IP systems in the event of external disturbances. Asymmetrical data streams The data flow from digital substations is often asymmetrical (upstream > downstream). PowerLink IP s data upstream and downstream channels can be adjusted to these different bandwidths. This option allows the data throughput to be adapted to the special requirements of modern grid applications. Notched frequencies PowerLink IP system 1 PowerLink IP system 1 f (khz) Channel spreading PowerLink IP System 1 PowerLink IP system 2 f (khz) PowerLink IP System 1 PowerLink IP system 2 f (khz) Asymmetrical data streams PowerLink IP system 1 (upstream direction) PowerLink IP system 1 (downstream direction) f (khz) Figure 5: Efficient bandwidth utilization 8

The PowerLink IP system PowerLink IP Configuration example Figure 6 shows a single communication link where the frequency band is almost fully utilized. In most cases, the entire channel bandwidth of up to 500 khz is not available for PowerLink IP communication. Parts of the frequency band cannot be used for PowerLink IP in order to protect radio services or traditional PLC systems operating in parallel. PowerLink IP permits the utilization of a broad frequency band that is subdivided into several sub-bands. Unavailable frequencies are notched. This configuration example shows a pair of PowerLink IP and traditional PLC systems that are sharing the communication channel of one energy line. The configuration accounts for two critical radio frequencies. Power line with PLC communication PowerLink IP PowerLink IP PLC PLC 36 PowerLink IP send blocked PowerLink IP send PLC send Power frequency range to be notched (e.g., for radio services) PL IP receive blocked PL IP receive PLC receive 500 f (khz) Channel bandwidth (send) for PowerLink IP Channel bandwidth (receive) for PowerLink IP Channel bandwidth reserved for traditional power line carrier system (send) Channel bandwidth reserved for traditional power line carrier system (receive) Figure 6: Configuration example (full band utilization on a single link) Integrated teleprotection system SWT 3000 One SWT 3000 system can be integrated into PowerLink IP (see Figure 3). This SWT 3000 system can transmit up to four protection commands. The command interface type for distance protection devices can be either standard binary I/O or compliant with IEC 61850 (GOOSE). A combination of both command interface types is also supported. 9

PowerLink IP Typical applications PowerLink IP typical applications Two main application scenarios for PLC systems have been established in the field for many years. The economical communication solution Although the main transmission lines are usually equipped with fiber-optic cables, there are many HV substations where the installation of fiber is not cost-effective. In this case, PowerLink IP serves as an economical solution that can also provide the required bandwidth to replace alternative connections like wireless communication. Figure 7 shows PowerLink IP as a single communication solution. The power line is used as the sole communication path between HV substations. PowerLink IP is connected to the power line by the traditional coupling capacitor and coupling unit. A line trap functions as a band-pass filter and separates the frequencies of the HV line segments. PowerLink IP serves as a single communication system for the diverse communication requirements of modern, future-proof digital HV substations (IP/Ethernet). The integrated SWT 3000 system provides the communication links for distance protection devices. Coupling capacitor and line trap Coupling unit Power line with PLC communication HV substation PowerLink IP with integrated SWT 3000 IP router (firewall, IDS, VPN) Ethernet switches Ethernet switches Station bus Communication LAN S/S controller IEC 104 RTU* PMU Fault recorder PQ recorder Protection devices CCTV IP phone Corporate applications Physical access control Field devices Figure 7: PowerLink IP as a single communication solution * IEC 60870-5-104 10

Typical applications PowerLink IP The backup communication solution PowerLink IP is the best solution for ensuring the highest availability of major HV links by establishing an alternative communication pathway for critical grid applications (for example, protection devices, RTUs, and voice). PowerLink IP meets the most stringent standards of transmission reliability. Even in worst-case scenarios (for example, fiber-optic and power line interruptions), teleprotection commands can still be transmitted. Figure 8 shows PowerLink IP as a backup communication solution in parallel with an installed fiber-optic link. In this solution, the primary communication path is provided by Ethernet over SDH (synchronous digital hierarchy) or MPLS (multi-protocol label switching) systems. This successful combination of fiber-optic communication technology with PowerLink IP guarantees the greatest transmission reliability for critical HV links. Optical ground wire (OPGW) Coupling capacitor and line trap Coupling unit Power line with PLC communication HV substation PowerLink IP with backup path MPLS Primary path IP router (firewall, IDS, VPN) Ethernet switches Ethernet switches Station bus Communication LAN S/S controller IEC 104 RTU* PMU Fault recorder PQ recorder Protection devices CCTV IP phone Corporate applications Physical access control Field devices Figure 8: PowerLink IP as a backup communication solution * IEC 60870-5-104 11

PowerLink IP From traditional to digital substations PowerLink IP from traditional to digital substations Integrating legacy devices via gateway/router If PowerLink IP is the only PLC system in the substation, legacy devices like analog phone and IEC 60870-5-101 RTU are connected using a small gateway/ router device that converts interfaces like analog voice, V.24, X.21, and E1 into Ethernet/IP protocol. All new substation devices that have IP/Ethernet interfaces may be connected directly to PowerLink IP. This process allows a stepwise exchange of the existing legacy devices. Figure 9 illustrates a typical configuration. Coupling capacitor and line trap Coupling unit Power line with PLC communication HV substation PowerLink backup path Distance protection Corporate applications IEC 104 Analog IEC 101 RTU 1 phone RTU 2 PABX Field devices Figure 9: PowerLink IP connecting legacy devices via gateway/router 1 IEC 60870-5-104 2 IEC 60870-5-101 12

From traditional to digital substations PowerLink IP In many cases, transmission utilities don t intend to replace all of their legacy devices in a HV substation at once with state-of-the-art Ethernet-based equipment. Instead, they prefer a smooth step-bystep migration of the relevant devices. PowerLink IP offers two options that support this preferred process. Coexistence of traditional power line carriers and PowerLink IP Traditional PLC systems can also be used in parallel with a new PowerLink IP system on the same power line. In most cases, the new PowerLink IP system can be connected to the existing coupling capacitor, line trap, and coupling unit. The traditional narrow-band PLC provides the communication link for the remaining legacy devices, and the new IP/Ethernet-based devices will be connected to PowerLink IP. PowerLink IP and the existing traditional PLC systems will utilize different frequency bands, which allows for the undisturbed operation of all the devices operating on the HV line at the same time. This solution facilitates the step-by-step replacement of legacy devices. Figure 10 illustrates a typical solution with a subdivided frequency band. Traditional PLC RF channel 36 khz PowerLink IP RF band Traditional PLC RF channel 500 khz f Coupling capacitor and line trap Coupling unit Power line with PLC communication HV substation PowerLink IP with integrated SWT 3000 Existing traditional PLC Ethernet switches IP router (firewall, IDS, VPN) Ethernet switches Station bus Communication LAN S/S controller IEC 104 PMU Fault RTU 1 recorder PQ recorder Protection devices CCTV IP phone Analog phone IEC 101 RTU 2 Teleprotection device with binary I/O Field devices Figure 10: PowerLink IP coexistence with traditional PLC 13

PowerLink IP Installation, maintenance and management system PowerLink IP installation, maintanance, and management system Installation and maintenance PowerLink IP as a pure packet-based communication solution reduces the skills required for installation and maintenance on the communication-protocol side to Ethernet/IP. Re-adjustment of transmit/receive frequency bands is simplified: fast adjustment of the Tx filter (transmit) no need to adjust the Rx filter (receive) The optional integrated Spectrum analyzer delivers a fast and easy diagnosis of signals transmitted/received as well as disturbances caused by external sources. It also simplifies the re-adjustment of the transmit filter. Frequency planning PowerLink IP s smart, unique, and enhanced smart frequency management system provides more than just significantly extended bandwidth allocation per system node. It reduces frequency planning effort, which is limited to defining the transmit/receive center frequencies, the frequency to be notched, and the device s quality-of-service requests. 14

Installation, maintenance and management system PowerLink IP Figure 11: PowerLink IP state-of-the-art user interface Web-based administration Intuitive and easy to operate, PowerLink IP uses commercial Web browsers for its system administration, which means that no additional software installation for administration or operation is required. The administration of a remote PowerLink IP system can be easily performed from the local operator console or via the corporate LAN network. State-of-the-art encryption technology for IP packet-based transmission is complemented by access restrictions on the device s Webbased administration portal, which requires the standard user log-in and password safeguards for Power Link IP communication applications. This user interface is ready for the touchscreen operation that is already available on modern equipment like tablet PCs; see Figure 11. Integration in network management systems PowerLink systems can be integrated into higher-level management systems using the SNMP protocol (simple network management protocol). System and network status data can be transferred, for example, to an alarm, inventory, or performance management system. 15

PowerLink IP Technical data and features PowerLink IP overview of technical data and features 16

Technical data and features PowerLink IP Technical data Transmission method Modulation HF frequency range HF bandwidth Frequency management Multicarrier modulation (windowed OFDM) for data; frequency shift keying for teleprotection 36 khz to 500 khz 8 khz to 256 khz, 250-Hz steps Dynamic bandwidth adaptation within the frequency domain of adjacent PowerLink IP devices Predefined bandwidth allocation Notching of occupied frequencies (up to 20 notches) Adjustable asymmetric traffic Adjacent and nonadjacent Tx/Rx band operation Teleprotection communication via MARC frequencies HF interface Output power Rated output impedance Spurious emission, return loss, tapping loss, balance to ground, receiver sensitivity, and selectivity Tx/Rx filter 50-W amplifier, up to +47 dbm PEP Adjustable 10 W to 50 W 100-W amplifier, up to +50 dbm PEP Adjustable 20 W to 100 W 75 Ohm unbalanced or 150 Ohm balanced In accordance with IEC 60495 Filter bandwidth 32 khz/min., 8-kHz steps Tx: simple adjustment using jumpers/rx: no adjustment necessary 17

PowerLink IP Technical data and features Transmission characteristics Transmission characteristics Dynamic transmission path adaption Latency Transmission capacity up to 2 Mbps Spectral efficiency 0.8 to 10.4 bps/hz Minimum SNR: 42.6 db for 16,384 QAM 36.6 db for 4,096 QAM 30.6 db for 1,024 QAM 24.5 db for 256 QAM 18.2 db for 64 QAM 11.4 db for 16 QAM 3.3 db for 4 QAM All values rated to 64-kHz bandwidth and block error rate (BLER) of 10E-6 (corresponding to a bit error rate (BER) of better than 10E-8) Modulation steps 4/16/64/256/1,024/4,096/16,384-QAM Typically 20 ms Depending on frame length and the currently used transmission system Ethernet interface Ethernet 3 x Ethernet 10/100 base TX; 1 x PoE; RJ45 2 x Ethernet 100 base FX; SFP PoE according IEEE 802.3af-2003, class 3, max. 15 W (on request only) ETH port isolation according to 802.1Q Layer 2 switch VLAN, IEEE 802.1Q QoS, IEEE 802.1p Full duplex, half duplex, auto negotiation Integrated teleprotection system SWT 3000 Overview Number of systems Operation modes Number of trip commands Number of interface modules Number of IEC 61850 modules Modulation AMP frequencies 1, integrated in the PowerLink frame Alternate multi-purpose (AMP) Up to 4 Up to 2 1 Coded tripping Trip 0.3 khz to 2.03 khz Guard 2.61 khz IEC 61850 command input/output EN100 Electrical interface Optical interface RJ45; 100 base TX; max. range 20 m SFP; 100 base TX; 1,300 nm; LC connector; max. range 1.5 km 18

Technical data and features PowerLink IP Binary command input/output Input IFC-P/IFC-D Rated input voltage DC 24 V to DC 250 V (tolerance: -20% to +20%) Nominal input voltage 24 V 48 V or 60 V 110 V 250 V Polarity independence Pulse suppression Selectable threshold voltage Low-level U in < 15 V, high-level U in > 18 V Low-level U in < 40 V, high-level U in > 47 V Low-level U in < 72 V, high-level U in > 85 V Low-level U in < 167 V, high-level U in > 198 V Yes 1 ms Up to 100 ms programmable in steps of 1 ms Command output IFC-P normal contact load IFC-D high-contact load IFC-S for signalling Contact type Relay, normally open contact Relay, IFC-D normally open contact, Relay, IFC-S changeover with common root Switching power 250 W/250 VA 150 W/1,250 VA Switching voltage AC/DC 250 V AC/DC 250 V Switching current AC/DC 1.5 A (5 A < 2.5 ms) AC/DC 5 A (30 A 0.5 ms) Carry current AC/DC 1.5 A AC/DC 5 A for IFC-D AC/DC 1 A for IFC-S Insulation withstand voltage 2,500 VAC 2,500 VAC Command transmission Transmission time T0 (SWT 3000 integrated into PowerLink)* Alternate multipurpose 19 ms * Values are given for the IFC-P module and permissive tripping. For direct tripping systems, the transmission time increases by about 5 ms. If the IFC-D module is used for increased contact load, all specified transmission times are prolonged by about 4 ms. Security (analog transmission path) Probability of unwanted commands P UC < 10-6 Dependability (analog transmission path) Probability of missing commands P MC < 10-4 at SNR of +6 db 19

PowerLink IP Technical data and features Miscellaneous Maintenance interfaces Service PC Service phone WEB UI via Web browser, https secure protocol DHCP client for ETH interface Via IP telephone or PC app Network management Element Manager Integration with NMS at higher level Web browser for local and remote access with user account/password for configuration and maintenance Via SNMP v2/3, alarm management (up to 4 destinations for alarm traps), inventory and performance management Event recorder Recording capacity Real-time clock PowerLink IP: 10,000 events and iswt: 8,000 events NTP, IRIG-B, line clock sync, 1 ms resolution Alarm module input/output Binary input 1 of ALR module for synchronization with: Sync pulse Nominal voltage Polarity independence DC 24 V to DC 250 V (tolerance: -20% to +15%) Yes IRIG-B Nominal voltage Polarity independence DC 5 V, DC 12 V, DC 24 V (tolerance: ±15%) No, defined polarity required Output ALR Module (relay) Number of alarm outputs Contact type Switching power Switching voltage Switching current Carry current 3 relay contacts Changeover contact 300 W (DC), 1,000 VA 250 V (DC or peak AC) 5 A (DC or peak AC) 1 A (DC or peak AC) 20

Technical data and features PowerLink IP Power supply Input voltage range PSPA2-DC PSPA2-AC DC 38 V to DC 72 V AC 93 V to AC 264 V (47 Hz to 63 Hz) and DC 85 V to DC 264 V Power consumption 50-W Amplifier (AC/DC) Typical value at normal operation 301 VA/104 W Typical value at max. operation 394 VA/146 W 100-W Amplifier (AC/DC) Typical value at normal operation 358 VA/131 W Typical value at max. operation 559 VA/215 W EMC immunity Immunity in industrial environments generic standard IEC 61000-6-2, for test levels see table. Immunity for equipment used in power station and substation environments IEC 61000-6-5, for test levels see table in (). Standards Electrostatic discharge IEC 61000-4-2 Radiated, immunity IEC 61000-4-3 Electrical fast transient IEC 61000-4-4 Surge immunity IEC 61000-4-5 Immunity to conducted disturbances IEC 61000-4-6 Power frequency magnetic field immunity IEC 61000-4-8 Voltage dips AC supply line IEC 61000-4-11 Voltage interruptions AC supply line IEC 61000-4-11 Test levels Direct/indirect contact discharge: 4 kv (6 kv) Air discharge: 8 kv 80 MHz to 1,000 MHz 10 V/m; 1 GHz to 6 GHz 10 V/m AC/DC supply lines: +/-2 kv HF input/output lines: +/-1 kv (+/-4 kv) Data input/output: +/-1 kv (+/-2 kv) 1.2/50 us (8/20) pulse Signal/control lines: +/-1 kv line to ground (+/-1 kv line to ground) HF input/output lines: +/-1 kv line to ground (+/-2 kv line to ground) DC supply lines: +/-0.5 kv line to ground; +/-0.5 kv line to line (+/-2 kv line to ground; +/-1 kv line to line) AC supply lines: +/-2 kv line to ground; +/-1 kv line to line 0.15 MHz to 80 MHz 10 Vrms (signal lines > 3 m and AC/DC power supply lines) 50/60 Hz; 30 A/m (100 A/m; 1,000 A/m for 1 s) 70% U for 1 period 40% U for 50 periods 0% U for 5 periods and 50 periods 21

PowerLink IP Technical data and features Standards Test for immunity to conducted common mode disturbances IEC 61000-4-16 Ripple on DC input power port immunity IEC 61000-4-17 Damped oscillatory wave immunity test IEC 61000-4-18 Voltage dips, short interruptions, and voltage variations on DC input power IEC 61000-4-29 Test levels (Signal/control lines: 50/60 Hz; 10 V and 100 V for 1 s (HF input/output lines: 50/60 Hz; 30 V and 300 V for 1 s) (DC supply lines: 50/60 Hz; 10 V and 100 V for 1 s) (DC supply lines: 10% Un) (HF input/output lines: 1 MHz; 2.5-kV common mode and 1-kV differential mode) 70% U for 0.1 s 40% U for 0.1 s 0% U for 0.05 s EMC emission Standards Emission standard for industrial environments Test levels Class A Safety Audio/video, information and communication technology equipment: safety requirements IEC 62368-1 International standards Single side-band power line carrier terminals IEC 60495 *) IEC 62488-2 ED1 *) Climatic conditions IEC 60870-2-2 * Valid for applicable parameters on digital PLC 22

Technical data and features PowerLink IP Climatic conditions Standards Cold IEC 60068-2-1 Dry heat IEC 60068-2-2 Damp heat, cyclic IEC 60068-2-30 Change in temperature IEC 60068-2-14: method Nb Test levels -10 C +55 C +25 C at 95% humidity +55 C at 93% humidity -10 C to +55 C Mechanical conditions Standards Test levels Degree of protection IP 20 Vibration stationary use IEC 60068-2-6 Resonance: 5 Hz to 9 Hz: 0.35 mm amplitude 9 Hz to 500 Hz: 1 m/s 2 acceleration Endurance: 5 Hz to 9 Hz: 3.5 mm amplitude 9 Hz to 200 Hz: 10 m/s 2 acceleration 200 Hz to 500 Hz: 15 m/s 2 acceleration Test of dynamic behavior during mechanical stress (shock test) IEC 60068-2-27: test Ea Half sine; 30 g acceleration; duration 18 ms Mechanical design 19 frame Dimensions 482 mm x 266 mm x 300 mm (W x H x D) Weight 17 kg 50 W; 19 kg 100 W 23

Published by Siemens AG 2017 Energy Management Division Freyeslebenstrasse 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.energy@siemens.com Article-No. EMDG-B90040-00-7600 Printed in Germany Dispo 06200 HL 17052919 B 09170.15 Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.