Electrical input data minal input voltage 220...240 Vac minal input frequency 50...60 Hz minal input current 0.2 A minal input power 42 W Power factor 0.9 Total harmonic distortion 30 Efficiency 85, maximum output voltage Input voltage AC 202...254 Vac Performance range Input frequency AC 47.5...63 Hz Maximum permissible range
Electrical output data Regulation method Constant Current Output voltage 24...48 Vdc Output voltage max 60 Vpk Peak voltage at open load Output current 0.3...1 A Full output current setting Output current tolerance ±8 Output current ripple 30 Ripple = peak / average Output power 14...37 W Full output Galvanic isolation SELV Lamp to mains Electrical data controls input Control method Fixed 0.2...1.5 2 WAGO250 (3.5 ), solid wire 16...24 AWG WAGO250 (3.5 ), solid wire Input wire strip length 8.5...9.5 Maximum cable length 60 Total length of wiring including LED module, one way Length (A1) 104 Width (B1) 68 Height (C1) 32 Fixing hole diameter (D1) 4 Fixing hole distance (A2) 93.5 Weight 132 gram Wiring Input wire cross-section Dimensions and weight Page 2 of 6
Operational temperatures and humidity Ambient temperature +0...+50 Tcase-max 75 Tcase-life 65 Measured at Tc-point Maximum housing temperature 130 In case of a failure Relative humidity 10...90 n-condensing Maximum temperature measured at Tc-point (lifetime reduced by 50) Storage temperature and humidity Ambient temperature -25...+85 Relative humidity 5...95 n-condensing Driver lifetime 30,000 hours Measured temperature at Tc-point is Tcase-life. Lifetime Maximum failures = 10 Features Open load protection Yes Automatic recovering Short circuit protection Yes Automatic recovering Over power protection Yes Automatic recovering Hot wiring Suitable for fixtures with protection class I and II Set output current Rset2 LED module temperature derating Constant Lumen Over Lifetime DCemDim See Design-in guide. Default output current: 1 A Certificates and standards Approval marks ENEC / CE / CQC Ingress Protection classification 20 Page 3 of 6
Additional information Inrush current Inrush current Ipeak 6 A Input voltage 230V Inrush current Twidth 55 µs Input voltage 230V, measured at 50 Ipeak Drivers / MCB 16A type B 40 pcs Earth leakage current 0.7 mapk LED module contribution not included Surge capability (L-N) 1 kv Surge capability (L/N-Ground) 2 kv Earth leakage current Mains input surge capability Page 4 of 6
Graphs Operating window Power factor versus output power Efficiency versus output power Page 5 of 6
Logistical data Product name Order code Logistic code 12NC 9290 008 71808 EAN3 Pieces per box 12 2013 Koninklijke Philips Electronics N.V. All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. Data subject to change. Date of release: www.philips.com/xitanium