Analog display for resistance current

Similar documents
Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Technical data sheet. Technical data

Monitoringsystem TAPGUARD 260

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. I/O expansion modules. Modules from the

Voltage regulator TAPCON 260

Power consumption In operation At rest For wire sizing

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Voltage regulator TAPCON 260

Signal Doublers. VariTrans A 20300

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Functional data Factory settings Variable Setting Torque Inhibiting torque

TAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS.

Voltage regulator TAPCON 260

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

SensoTrans DMS A 20220

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Operating instructions. Switching amplifier DN0210 DN / / 2015

OPERATING INSTRUCTIONS

DATA SHEET Selectable AC transducer, TAS-331DG

Tap Manager TM100. Operating Instructions

CMC III Temperature/Humidity Sensor

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

tapcon 230 user-friendly, FleXiBle and reliable. transformer control

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Electronic Temperature Controller. Instruction Manual Version

Voltage regulator TAPCON 240

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

PHOENIX CONTACT - 05/2007

DINALOG A 144 x 36 A1400 Light-Strip Indicator

SAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

CMC III Universal Sensor

Digital On-Load Tap Changer Voltage Controller TAPCON 250 Operating Instructions (short version) BA 289

LineMaster 100 Continuous-line Recorder

TF501, TF521 Terminal Bases

BMF400 Input/output module

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

CLIPLINE complete. The modular terminal block system for all applications

C9900-P223 and C9900-P224

Zener Barriers Bulletin 937Z

QUINT-BUFFER/24DC/24DC/40

TAPCON 230 Voltage Regulator for Regulating Transformers

Redundancy Module QUINT-DIODE/40

C9900-P208 and C9900-P209

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

PHOENIX CONTACT - 07/2006

Monitoringsystem TAPGUARD 260

AO561 Analog Output Module

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Power Supply HARTING pcon

Operating instructions. Speed monitor D / / 2014

TRIO-DIODE/12-24DC/2X10/1X20

Product and functional description

Installation manual plugs and connectors with screw connection (16/32 A)

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

STEP-PS/1AC/24DC/1.75

Technical data sheets

TAPCON 240 Voltage Regulator for Regulating Transformers

Documentation. Mains filter AX2090-NF50. Version: Date:

DATA SHEET Selectable AC transducer, TAS-321 DG

Faults on the system Proximity switch connection technology:

AI561 Analog Input Module

Operating Instructions

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Instructions

Operating Instructions VEGAMET 381

SensoTrans DMS P 32200

MSENSE BM MONITORING FOR BUSHINGS.

TU531, TU532 Terminal Unit

DI572 Digital Input Module

Power Supply HARTING pcon

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

DC561, digital input/output module,

Compact Universal Controllers

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Voltage Regulator TAPCON 230 expert

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Products no longer available

Products no longer available

Transcription:

www.reinhausen.com Analog display for resistance current Operating Instructions BA 2220061/01

NOTE The product may have been modified after this document went to press. We expressly reserve the right to make changes to the technical data, the design or the scope of delivery. In general, the information provided and the arrangements agreed during processing of the relevant offers and orders are binding.

Table of Contents 1 Safety... 5 1.1 Explanation of safety labels... 5 1.2 Safety instructions... 5 2 Configuration/Types... 6 3 Principle and configuration... 7 3.1 Principle... 7 3.2 Configuration... 7 3.3 Connection... 7 3.3.1 Tap position indicator device, square version... 7 3.3.2 Tap position indicator device, rectangular version with separate measuring bridge... 7 3.4 Settings and adjustment... 7 3.4.1 Tap position indicator device, square version... 7 3.4.2 Tap position indicator device, rectangular version with separate measuring bridge... 8 4 Technical data... 9 4.1 Mechanical data... 9 4.2 Electrical data... 9 4.3 Accuracy under nominal conditions... 10 4.4 Ambient characteristics... 10 4.5 Regulations... 10 5 Annex... 11 5.1 Connection diagram of tap position indicator device with square front frame (897897:3M)... 11 5.2 Connection diagram of tap position indicator device with rectangular front frame (898105:3M) 12 5.3 Dimension drawing of tap position indicator device with square front frame (899030:0M)... 13 5.4 Dimensional drawing ofpower supply unit with bridge circuit (898106:2M)... 14 The copying, distribution and utilization of this document as well as the communication of its contents to others without expressed authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or ornamental design registration. Maschinenfabrik Reinhausen GmbH 2007 3

1 Safety 1 Safety 1.1 Explanation of safety labels The following safety labels relating to the operation of the digital signal transfer unit for remote tap position indication are used in these Operating Instructions. These labels must be observed at all times! ATTENTION! Refers to a potentially hazardous situation that may result in damage to the product or adjacent equipment. NOTE Contains important information and special notes. NOTE! Risk of damage to the motor drive unit, on-load tap-changer and transformer! The signal transfer unit may only be used with the on-load tap-changer specified in the order. It is the responsibility of the user to make sure that the signal transfer unit is used for the specified application only. For safety reasons, any unauthorised work, i.e. installation, alteration, commissioning or modification of the signal transfer unit is forbidden without first consulting MR. 1.2 Safety instructions All warnings and safety instructions must be observed at all times! Failure to follow the safety instructions may lead to accidents and severe personal injury. Please read these operating instructions before commissioning the equipment! Read the Operating Instructions before commissioning the digital tap position indicator. As the operator, you are responsible for ensuring that users of the equipment have fully understood the operating and safety instructions. Train your staff! Before asking staff to work with the digital tap position indicator, provide training regarding general and special safety instructions and accident prevention regulations. Only suitably qualified personnel should work with the digital tap position indicator. The digital tap position indicator is designed exclusively for application in electrical or energy systems and facilities operated by appropriately trained staff i.e. staff who are familiar with the installation, assembly, commissioning and operation of such products. Maschinenfabrik Reinhausen GmbH 2007 5

2 Configuration/Types 2 Configuration/Types For transformers where the transformer ratios are modified through on-load tap-changers with remote-controlled motor drives, the operating positions of the on-load tap-changer have to be displayed in the control room. The square tap position indicator instrument shown in drawing 897897:3M is generally equipped with an integrated power supply unit. The rectangular tap position indicator instrument shown in drawing 898105:3M is equipped with an additional power supply unit with bridge circuit according to drawing 898106:2M. The devices can be mounted with the two screw spindles provided. Insert the screw spindle into the bracket from the rear of the device (plastic handle facing backwards) and turn it sideways to the first recess (for control panel thickness up to 20 mm) to the second recess (for control panel thickness 20-40 mm). Fold in the screw spindle and push the device into the control panel cutout. Turn the screw spindle until it latches (90 angle relative to the device) and tighten it manually or with a small screwdriver. NOTE Before tightening the screw spindle carefully move it back and forth in order to ensure free movement. NOTE In a high-density installation the screw spindles can be mounted between the devices, since they are diagonally offset. The power supply unit is designed for top hat rail mounting according to DIN EN 50022. 6 Maschinenfabrik Reinhausen GmbH 2007

3 Principle and configuration 3 Principle and configuration The tap position indicator instrument displays the current position of the motor drive or the on-load tap-changer at any location, usually in the control room. 3.1 Principle Each motor drive position corresponds to a contact area on the position transmitter board that is contacted by the slider. The contact areas are connected with the position transmitter module (resistor type) via the position transmitter cable. In the position transmitter module a modified resistance value is transferred to the input of a tap position indicator instrument, depending on the position. The display instrument operates with a resistance range of 60-2700 ohm. 3.2 Configuration In the motor drive unit a resistor-type position transmitter position transmitter is required. The resistor contact range (10 ohm per step) must match the number of required positions. The resistor module is connected with the display instrument or the power supply unit with bridge circuit via a signal line. 3.3 Connection ATTENTION! Before connecting the device ensure that the auxiliary voltage is within the range specified on the nameplate. 3.3.1 Tap position indicator device, square version Standard connection Connect the device according to the wiring diagram on the nameplate at the rear of the housing. The numbers in the wiring diagram match the numbers on the terminals. Terminals 1-3 potentiometer teletransmitter Terminals 4-7 auxiliary voltage A trim potentiometer for minimum scale value E trim potentiometer for full-scale value Extended setting range To extend the setting range for the minimum or full-scale value, set potentiometer R A or R E : Extended setting range for minimum scale value (zero elevation): calibration with potentiometer R A Extended setting range for full-scale value (full-scale value suppression): calibration with potentiometer R E R A : Trim potentiometer for extended minimum scale value range R E : Trim potentiometer for extended full-scale value range 3.3.2 Tap position indicator device, rectangular version with separate measuring bridge Standard connection Connect the device according to the wiring diagram on the nameplate at the rear of the housing. The numbers in the wiring diagram match the numbers on the terminals. Terminals 1-3 potentiometer teletransmitter Terminals + and - switch position indicator Terminals 4-7 auxiliary voltage A trim potentiometer for minimum scale value E trim potentiometer for full-scale value Extended setting range To extend the setting range for the minimum or full-scale value, set potentiometer R A or R E : Extended setting range for minimum scale value (zero elevation): calibration with potentiometer R A Extended setting range for full-scale value (full-scale value suppression): calibration with potentiometer R E R A : Trim potentiometer for extended minimum scale value range R E : Trim potentiometer for extended full-scale value range 3.4 Settings and adjustment 3.4.1 Tap position indicator device, square version Two balancing resistors are installed at the rear of the device for setting or adjusting parameters. The balancing resistors are used for setting the minimum and maximum scale values. Maschinenfabrik Reinhausen GmbH 2007 7

3 Principle and configuration Calibration Check the connection Remove the caps for trim potentiometers E and A at the rear of the device. Apply auxiliary voltage Move the motor drive unit into the minimum switching position using the potentiometer teletransmitter. NOTE If the pointer points to maximum rather than minimum when the potentiometer teletransmitter is in its minimum position or vice versa, the potentiometer teletransmitter connecting cables 2 and 3 are reversed. In this case switch off the device and reverse connecting cables 2 and 3. Set the pointer of the switch position indicator to the minimum scale value with potentiometer A. Move the motor drive unit into the minimum switching position using the potentiometer teletransmitter. Set the pointer of the switch position indicator to the maximum scale value with potentiometer E. Repeat these steps and readjust the pointer deflections to match the minimum and maximum scale value. Re-install the caps for the trim potentiometers. NOTE If the pointer points to maximum rather than minimum when the potentiometer teletransmitter is in its minimum position or vice versa, the potentiometer teletransmitter connecting cables 2 and 3 are reversed. In this case switch off the device and reverse connecting cables 2 and 3. Set the pointer of the switch position indicator to the minimum scale value with potentiometer A. Move the motor drive unit into the minimum switching position using the potentiometer teletransmitter. Set the pointer of the switch position indicator to the maximum scale value with potentiometer E. Repeat these steps and readjust the pointer deflections to match the minimum and maximum scale value. Re-install the caps for the trim potentiometers. 3.4.2 Tap position indicator device, rectangular version with separate measuring bridge Two balancing resistors are installed at the front of the measuring bridge for setting or adjusting parameters. The balancing resistors are used for setting the minimum and maximum scale values. Calibration Check the connection Remove the caps for trim potentiometers E and A at the front of the measuring bridge. Apply auxiliary voltage Move the motor drive unit into the minimum switching position using the potentiometer teletransmitter. 8 Maschinenfabrik Reinhausen GmbH 2007

4 Technical data 4 Technical data 4.1 Mechanical data Type Casing for installation in control panels or machine consoles, modular Casing material Polycarbonate, self-extinguishing and non-dripping according to UL 94 V 0 Front screen Sheet glass Front frame colour black (similar to RAL 9005) Mounting position vertical ± 5 Fastening Screw spindle Installation High-density installation possible Control panel thickness <= 40 mm Connection Hex bolts with M4 and bolt clamp strap Wire section max. 2.5 mm² Display dimensions Square front frame with 72 x 72 mm bridge circuit 96 x 96 mm 144 x 144 mm Installation depth 120 mm (all models) Rectangular front frame 96 x 48 mm Installation depth 107 mm 144 x 72 mm Installation depth 192 mm Circuit board section 68 x 68 mm 92 x 92 mm 138 x 138 mm 92 x 45 mm 138 x 68 mm Dimensions of power supply 45 x 73 x 119 mm unit with bridge circuit Drawings 897897:3M, 898105:3M, 898106:2M 4.2 Electrical data Measured variable DC Overload limit according to DIN EN 60051 Continuous 1.2 x max. 5 s 10 x Protection class II IP rating IP20 Insulation group A according to VDE 0110 Rated insulation voltage 1000 V Test voltage 3 kv at 50 Hz, 1 min. according to DIN 57410 Supply voltages 9.6-15 V DC, 20-29 V DC, 43-54 V DC 51-70 V DC, 93-132 V DC, 190-235 V DC 98-126 V DC, 195-253 V DC, 340-440 V DC Maschinenfabrik Reinhausen GmbH 2007 9

4 Technical data 4.3 Accuracy under nominal conditions Precision class 1.5 according to DIN EN 60051 Nominal conditions Ambient temperature 23 C ± 1 K Mounting position Nominal mounting position ± 1 Input variable Nominal measuring range Other DIN EN 60651 Influence factors Ambient temperature 10 C... +55 C Mounting position Nominal mounting position ± 5 Stray magnetic field 0.5 mt 4.4 Ambient characteristics Climate suitability Climate class 3 according to VDE/VDI 3540 Operating temperature -10 C... +55 C range Storage temperature range -25 C... +65 C Relative humidity <= 75% on average over the year, no condensation Impact resistance 15 g, 11 ms Vibration resistance 2.5 g, 5...55 Hz 4.5 Regulations DIN 43700 DIN 43701 DIN 43718 DIN 43802 DIN 16257 DIN 57410/VDE 0410 DIN 60051 VDE 0110 VDE 0411 DIN 40050 VDE/VDI 3540 Sheet 2 Devices for flush mounting, nominal and section dimensions Electrical control panel measuring instruments Front-frames and front panels Line scales and pointers for electrical measuring instruments Nominal positions and position symbols used for measuring instruments Safety regulations for measuring instruments with display and recording function, and accesories Direct acting indicating analogue electricalmeasuring instruments and their accessories Regulations for determining clearances and creepage distances of electrical equipment Safety requirements for electronic measuring instruments Degrees of protection (IP-code); protection against foreign objects; water and contact; electrical equipment Reliability of measuring and control devices (climate classes for devices and accessories) 10 Maschinenfabrik Reinhausen GmbH 2007

5 Annex 5 Annex 5.1 Connection diagram of tap position indicator device with square front frame (897897:3M) Maschinenfabrik Reinhausen GmbH 2007 11

5 Annex 5.2 Connection diagram of tap position indicator device with rectangular front frame (898105:3M) 12 Maschinenfabrik Reinhausen GmbH 2007

5 Annex 5.3 Dimension drawing of tap position indicator device with square front frame (899030:0M) Maschinenfabrik Reinhausen GmbH 2007 13

5 Annex 5.4 Dimensional drawing ofpower supply unit with bridge circuit (898106:2M) 14 Maschinenfabrik Reinhausen GmbH 2007

5 Annex Maschinenfabrik Reinhausen GmbH 2007 15

5 Annex 16 Maschinenfabrik Reinhausen GmbH 2007

www.reinhausen.com Maschinenfabrik Reinhausen GmbH Tel: +49 (0)941 4090 0 Falkensteinstrasse 8 Fax: +49 (0)941 4090 7001 D - 93059 Regensburg E-mail: sales@reinhausen.com 0310 F0183101