Compatibility Report. Comtrol IO-Link Master. Keyence LR-W500C Sensor

Similar documents
Compatibility Report. Comtrol IO-Link Master. Keyence LR-TB5000C Laser Sensor

Compatibility Report. Comtrol IO-Link Master

Compatibility Report. Comtrol IO-Link Master. Contrinex DW-AD-603-C8

COMPATIBILITY REPORT

Compatibility Report. Comtrol IO-Link Master. Microsonic sks-15/cf Proximity Sensor

Compatibility Report. Comtrol IO-Link Master. Contrinex LHR-C23PA-PMS-403

Comtrol IO-Link Master Banner Engineering TL50 Tower Light

COMPATIBILITY REPORT

COMPATIBILITY REPORT

COMPATIBILITY REPORT

COMPATIBILITY REPORT

COMPATIBILITY REPORT

Document Number: Rev. B

Document Number: Rev. C

OPC UA TECHNICAL SUPPORT GUIDE

PROFINET IO and Modbus/TCP. User Guide

Chapter. Managed Switch Software Advanced. Operations. In This Chapter...

Instruction with Screenshot for WEB

How to upgrade the firmware

TROUBLESHOOTING : 1. Set up your wireless router via wired connection. 2. Please make sure your adapter is set to obtain IP automatically

Oracle Sourcing Support Helpdesk: Telephone: > Option

DCH-G022 mydlink Connected Home Hub

1 Hardware Installation

BRIGGS & VESELKA CO. ProSystem fx Portal. Client Portal Admin User Guide

Lab - Connect to a Router for the First Time

Conquest Ethernet Controller Configuration Web Pages

Portal User Guide. E. Martin Davidoff & Associates, CPAs E. Martin Davidoff, Attorney at Law

Note: If you have not read the TROY TONER LOW NOTICE WARNING, please do so and take the appropriate actions before continuing.

Resource Center Getting Started Guide

NCR. Wi-Fi Setup Assistant. User guide

Group Admin Guide. NetBrain Consultant Edition 6.2

Perceptive Process Enterprise - UNIX Installation Guide

Using the Media Server Administrator (MSA) Interface for the Hardware Media Server

Getting Started with Penn State WikiSpaces

Network Camera Firmware Upgrade Quick Guide

Firmware/Language Upgrade on the RV130 and RV130W Using the Web Interface

CCH Portal Client User Guide

BITMAIN. S2 Server Manual

What can I do in the settings menu of my WL-330 (which settings are there and what can I change)?

Using NetShow Commands

Video Decoder Setup Guide

TrendView Credits Option Code Instruction Sheet

OPC-UA Tutorial. A Guide to Configuring the TOP Server for OPC-UA

1. TABLE OF CONTENTS. 1. Table of Contents Guide Instructions Access Tririga Reset Your Password... 8

- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

Polycom RealPresence Resource Manager System

Nova series update F/W & Boot code from Boot Utility

Firmware Revision History and Upgrade Instructions

ProSystem fx Portal User Guide

RV2458 Router User Manual

IBM Emptoris User Guide

DeviceMaster UP Modbus Router Shared Memory Controller to Controller Communication

Exporting a Course. This tutorial will explain how to export a course in Blackboard and the difference between exporting and archiving.

CJ Series IO-Link Connection Guide (EtherNet/IP TM Host Communications) OMRON Corporation Proximity Sensor (E2E-series IO-Link)

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

Trademarks. Statement of Conditions by NETGEAR, Inc. All rights reserved.

UCS-E160DP Double-wide E-Series Server, 6 core CPU, with PCIe

Ethernet Interface Module

How to access My.QuestForHealth.com

Support Portal Guide VERSION 1.0

DocAve v5 Installation Configure your DocAve 5 Platform Quickly and Easily

Web Self Service Administrator Guide. Version 1.1.2

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

Innovative Electronics for a Changing World INDEX

NPS Apps - Google Docs Facilitated by Liza Zandonella Newtown High School May, 2013

Using the hierarchy... 4 Using Filter Groups... 7 Defining Filter Groups... 7 Example... 8 Linking Filter Groups Limiting functionality...

How to Update Firmware & HTML ipower Generation 2

ProSystem fx Portal Client User Guide Getting Started March 1, 2013

Rev. 06 Nov User Guide: Downloading and Logging into Skandocs

User Administration Vaultview Security

Resource Manager System Upgrade Guide

Conquest Ethernet Controller Configuration Web Pages

CJ Series EtherNet/IP TM Connection Guide. OMRON Corporation RFID Reader/Writer (V680S-series) P626-E1-01

AST2500 ibmc Configuration Guide

Attix5 Pro Storage Platform Console

4G WiFi M2M Router (NTC-140W Series) Firmware Upgrade Guide

Portal Client User Guide

Electronic Appraisal Delivery (EAD) Portal. FHA EAD Lender Admin Guide

CDE460/470 IPMI Firmware Upgrade. Reviewers. Modification History

Branding Customizations

Xerox Mobile Client for DocuShare User Guide

Version 3.8. Accela Construct. Administrator Guide

Serv-U File Sharing Application

Procedure to Upgrade Verizon FiOS Router and Configure Xbox 360 to connect with Microsoft USB WiFi Adapter

Recovering a NetComm Wireless M2M router via the recovery console. Technical Support Guide

ECB E-TENDERING SUBMISSION OF A RESPONSE IN A PROCUREMENT PROCEDURE ( RFX )

APP Setup Guide. Connect to your home or business from anywhere in the world. RINS1721-3

Upgrading a device from an 071.xxx.xxx.xxxxx version to an 073.xxx.xxx.xxxxx version. How to determine your starting version

Branding Customizations

6.2 Ingredion Learning Workday Drive Learning Admin - 08.Nov.2018

Introduction. The topics included in this guide are:

Note: This feature is available only for Enterprise licensed users. idrac GUI

Quick Start Manual G2-2 Series with Ethernet Interface

Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

Installing Oracle Database 11g on Windows

ClassLink Student Directions

D120-S3G User s Guide

Xerox App Gallery App Gallery User Guide. Version 5.0 September P06709

Paperless Tax Office Automation

Synchro PRO 2016 Shared User License Manager Installation Instructions

Transcription:

Compatibility Report Comtrol IO-Link Master Keyence LR-W500C Sensor

Contents Contents... 2 Test Report Overview... 3 IO-Link Master - IO-Link Diagnostics Page... 3 Configuring IO-Link Settings... 4 After Configuring Port-Friendly Names... 5 Setting Up Passwords... 6 LR-W500C Configuration... 7 Loading IODD Files... 7 Verifying that the Correct IODD Files Are Loaded... 9 Changing Parameters on the LR-W500C with the GUI... 10 Changing Parameters Using the ISDU Interface... 11 Using the Device Validation Feature... 13 Incompatible Device Attached to Port... 14 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 2

Test Report Overview Upon connection, the Keyence Self-Contained Full-Spectrum Sensor, LR-W500C, was immediately powered by the Comtrol IO- Link Master. After initializing the LR-W500C for IO-Link operations, the sensor displayed in the Comtrol IO-Link Diagnostics web page. To set the LR-W500C in IO-Link mode, see the Keyence manual on how to set the sensor to PNP. This report contains the following topics: IO-Link Master IO-Link Diagnostics page Configuring IO-Link settings Setting up passwords Configuring the LR-W500C sensor with an IODD file Restoring the LR-W500C to factory defaults Using the Device Validation feature The sensors were tested using Application Base v1.4.16 on the IO-Link Master 8-EIP (machine mountable IP67). This report does not illustrate all Comtrol IO-Link Master features, such as: EtherNet/IP, Modbus/TCP and OPC UA configuration, uploading the latest software, or network configuration. In addition, Data Storage is not discussed because the LR- W500C does not support data storage. IO-Link Master - IO-Link Diagnostics Page Upon connection to the IO-Link Master, the LR-W500C displays in the IO-Link Diagnostics page after initializing the LR-W500C. This is not a complete screen shot of the IO-Link Diagnostics page. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 3

Configuring IO-Link Settings During IO-Link configuration, the Minimum Cycle Time can be left to the default value, as the IO-Link Master negotiates the required Cycle Time with each sensor. This example shows configuring a friendly port name. The Device Validation feature is discussed later in the report. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 4

After Configuring Port-Friendly Names The IO-Link Diagnostics page now displays Port Names and Port Modes and Status. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 5

Setting Up Passwords The IO-Link Master ships from the factory without passwords and administrative permissions are granted. You can use the Advanced Accounts page to set up passwords for the IO-Link Master. Admin, Operator, and User permissions are defined in the help system on the Accounts page. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 6

LR-W500C Configuration You can use the Comtrol IO-Link Master to configure the IO-Link device. If an IODD file is loaded on the IO-Link Master, you may want to use the GUI on the top of the IO-Link Device Port page to change parameter settings. If an IODD file is not loaded, you can use the ISDU Interface on the bottom of the IO-Link Device Port page This section discusses the following topics: Loading IODD files Verifying that the correct IODD file is loaded Changing IO-Link device parameters using the GUI Resetting to the IO-Link device to factory defaults Changing IO-Link device parameters using the ISDU Interface Loading IODD Files IODD file packages must be unzipped and the appropriate files located and re-zipped or loaded individually. 1. Click Attached Devices IODD Files. 2. Click the UPLOAD FILE button. 3. Select the CHOOSE FILE button. Then select the file from your documents. 4. Once it appears on the webpage, click the UPLOAD button. 5. If there are files in the IODD file set that are not required by the associated xml file, the IO-Link Master does not load the files, and displays an Ignored Files message. Click Ok to close the message. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 7

6. The IODD Files page now displays the IODD files loaded on the IO-Link Master. 7. If you want to view the xml file, click the corresponding IODD FILE NAME in the table. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 8

8. Optionally, click the hyperlink to view the xml file in your browser. Verifying that the Correct IODD Files Are Loaded Use the IO-Link Device Configuration Summary page to verify that the correct IODD files for the attached IO-Link devices have been loaded on the IO-Link Master. The correct file is loaded if an xml file name displays in the IODD Name field. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 9

Changing Parameters on the LR-W500C with the GUI 1. The LR-W500C displays as expected in the PORT page. Click EDIT to make changes in the table. 2. Click the SAVE button to make parameter changes using the GUI NOTE- Parameters will be confined to the minimum and maximum values. Those with smaller ranges may be displayed with a drop-down menu, and those with larger values with a box to type the value in. In some occasions, there may be a check box. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 10

Changing Parameters Using the ISDU Interface This shows using the IO-Link ISDU Interface to change configuration parameters. Open the IO-Link Device ISDU Interface by clicking the + next to the name. Please note: You must enter the hexadecimal value for the ISDU Block Index and ISDU Sub-index. The following images do not display the complete web page. The following screenshots do not illustrate the system responses. The IO-Link Master responds with a command executed notification. 1. If necessary, retrieve the current value of the ISDU Index that you are planning on changing. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 11

2. Change the parameter from 00 to 01. 3. See that the command was executed successfully. 4. Click REFRESH to observe that the parameter changes executed. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 12

Using the Device Validation Feature The LR-W500C supports Compatible Device Validation. A device serial number is required for Identical Device Validation. This report does not illustrate Compatible Device Validation with another LR-W500C because a single LR- W500C was available for testing. Incompatible Device Attached to Port 1. In the IO-Link Configuration page, click EDIT, set Device Validation mode to Compatible. 2. Click the GET ATTACHED button. 3. Click SAVE. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 13

4. Remove the LR-W500C and connect another IO-Link device (not an LR-W500C). 5. The IO-Link LED on the IO-Link Master is now flashing red to indicate that an incompatible device is connected to the port. In addition, the IO-Link Diagnostics page displays that an incompatible device is attached to the port. 3/3/2017 Comtrol IO-Link Master Keyence LR-W500C P a g e 14