Aquaflair. BREC/F and BCEC/F kw

Similar documents
Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Ecoflair Air Economizers

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Close-coupled cooling

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Uniflair Access Floor for data centers

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

New Design Strategies for Energy Saving. Intelligent free-cooling

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Data Center Energy Savings By the numbers

Indirect Adiabatic and Evaporative Data Centre Cooling

Indirect Adiabatic and Evaporative Data Center Cooling

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Liebert. EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Efficiency of Data Center cooling

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

High Efficient Data Center Cooling

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Precision Cooling Mission Critical Air Handling Units

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Rack cooling solutions for high density racks management, from 10 to 75 kw

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

AireFlow kW DX AIR. Data Centre Cooling Product of the Year. Indirect Adiabatic AHU

HIGH EFFICIENCY Central Chiller

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

kyalfa V- VDD/VDD6 General Contents

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Industry leading low energy evaporative fresh air cooling.

1.0 Executive Summary. 2.0 Available Features & Benefits

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

How Green can you go?

Specification and Design Catalog. Waterside Economizer

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

MOLLIER DIAGRAM CAN BE IMPROVED!

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Retro-Commissioning Report

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Air Containment Design Choices and Considerations

Air-Cooled Series R Chiller

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

DATA CENTER LIQUID COOLING

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

Trailblazer AGZ-E air-cooled scroll chillers

MSYS 4480 AC Systems Winter 2015

A BSRIA Guide. Free Cooling Systems BG 8/2004 FREE COOLING SYSTEMS BSRIA By Tom De Saulles. Supported by

18 th National Award for Excellence in Energy Management. July 27, 2017

Case Study The University of Warwick

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2

Saving Energy with Free Cooling and How Well It Works

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

Blue e+ chillers with the principle

Water cooled chiller plant (all-variable)

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

Welcome Association of Energy Engineers to the Microsoft Technology Center

PREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!

Ecotel Free Cool 5-15kW

Impact of Air Containment Systems

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Trading TCO for PUE? A Romonet White Paper: Part I

Datacenter Cooling. DC Cooling Efficiency and Project experience. Osman Uzuner. Vakıfbank Central Systems Management Datacenter Operations

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Recapture Capacity for Existing. and Airflow Optimization

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products

4-step Chiller and Heat Pump Controller

HIGH DENSITY RACK COOLING CHOICES

1008 kw, Tier 2, Chilled Water, ft 2

Pressure transmitters OsiSense XMLP for industrial applications. Catalogue

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Communication Interface

Google s Green Data Centers: Network POP Case Study

Transcription:

Aquaflair Air-cooled chillers and free-cooling chillers with screw or oil-free centrifugal compressors equipped with adiabatic system BREC/F and BCEC/F 350-1350 kw Dualism for evolution: the combination of air with water >Aquaflair adiabatic chillers designed to guarantee Total Cost of Ownership (TCO) reduction and complete integration in Tier III and IV mission-critical installations. >The all-in-one packaged solution, completely tested and ready to install; it includes the latest technologies for efficiency and continuous operation. >Optimized and enhanced free-cooling (economization) system to match with the latest cooling datacenter guidelines for maximized efficiency at any latitude.

Guidelines for datacenter cooling Temperature and water flow rate design ASHRAE Guidelines > ASHRAE guidelines permit to operate with higher operating temperatures in order to maximize system efficiency > CRAC/CRAH units need to be designed for discharge temperature and moisture control > CRAC/CRAH units need to be optimized according to the recommended water temperature range and a higher delta T An effective route to saving OPEX and CAPEX. High water temperatures: > are mandatory to comply with ASHRAE standards > improve OPEX since they optimize the cooling circuit and extend economization > allow for CAPEX reduction since chillers can be downsized * Paris climate conditions, constant thermal load 1MW, data refer to chiller only The next frontier Wide DeltaT Operation > This new generation of cooling units allows for the application of optimum theoretical temperatures > High water temperatures save both CAPEX and OPEX > Adiabatic cooling reduces energy consumption and, combined with wide deltat, it further improves the total OPEX What does it mean to shift design * from 18/24 C to 18/28 C OPEX saving > Pump power saving: -15% > Extended economization: +4 C > Less power consumption on fan side: -20% CAPEX improvement > Saving on hydraulic infrastructure > Reduced pressure drop up to 70kPa * Site: Paris, Unit: BREF2812A, Unit Capacity: 1000kW, Design water temperature: 18 C

Make your Data centers cool! Adiabatic system The system exploits the natural process of water evaporation to shift the average suction condensing and free-cooling coils air temperature to the wet bulb conditions. As water evaporates, energy is dissipated by the air and temperature is reduced, which means operating conditions are improved and energy efficiency is maximized. Energy consumption Traditional freecooling 18/24 C Applications > the system is available for large air-cooled and and free-cooling Aquaflair chillers (>300kW) Installations > completely factory fitted, tested and ready to be installed. The system is embedded in the unit footprint and therefore ready for standard ISO container shipping Operation Maintenance Adiabatic freecooling 18/24 C > the adiabatic system is completely managed by the unit control board > maintenance is easy since the unit is completely accessible and limited to some components only An enhanced solution for economization Free-cooling chillers can further improve the energy saving with an enhanced freecooling surface* > Free-cooling mode maximization > Integration with adiabatic system > Factory-fitted and tested solution Traditional freecooling 18/28 C > Footprint improvement, compared to a solution with chillers combined with dry-coolers (-30%) -22% -35% Adiabatic freecooling 18/28 C Data calculated on Paris climatic profile, constant 1MW thermal load CRACs Chiller Benefits > Improved cooling capacity with lower CAPEX (up to 10% saving) > Increased efficiency in summer mode, lower OPEX (10/15%, depending on the climatic zone) > Extended economization capability, optimized OPEX (up to 3 C more economization hours) > No additional air suction pressure drop *On request, unit dimensions increase Data calculated comparing traditional free-cooling units at 18/24 C water temperature with enhanced free-cooling adiabatic chillers at18/28 C water temperature

How it s made Exclusive arrangement The exclusive Schneider Electric system is designed to improve unit efficiency in any condition without affecting unit operation, footprint, maintenance and reliability The adiabatic solution on large chillers is based on: > Nozzles: their position has been defined in order to optimize the drop distribution > Layout: the V shape arrangement for coils and free-cooling coils allows for integrated installation > Protective filter: prevents non-evaporated water from damaging the internal components and the coils > Embedded control system: it monitors, controls and optimizes the unit operation, including adiabatic Protective filters Baffles Onboard pumping for adiabatic system Nozzles Water collect and discharge system A comparison with current available systems > wet net and spray nozzle system > wet medium in front of the heat exchangers > nozzle system and pumping station Control board and human interface Schneider-Electric Nozzle Wet media Wet net + nozzles Adiabatic effect 20 m drop size Additional pressure drops negligible Easy to install / can be retrofitted integrated Fouling/corrosion on heat exchangers cleanable Water consumption 2.5l/h Oerational EXpense Up to 10/15% less Biochemical pollution available solution Maintenance costs complete access

Technical details System description The system is completely integrated in the unit, managed and controlled by the onboard control system and related sensors. Units with adiabatic system are fitted with the following additional devices on the standard unit. Frame > The frame is equipped with lateral baffles, finished in epoxy powders (color RAL9022), to contain the adiabatic effect in the event of lateral wind > Each condensing coil is protected by a specific filter and equipped with a pan to collect the unevaporated water > A discharge water circuit drains unevaporated water to a single connection point Control board and human interface > The unit control board is connected to the adiabatic system to activate the pre-cooling effect on the dry bulb/wet bulb temperature difference. This arrangement activates the system only under suitable outdoor conditions, optimizing water usage > The unit is fitted with embedded outdoor temperature and relative humidity probe to continuously monitor the outdoor conditions > All the operating parameters are visualized on the unit human interface and transmitted to the BMS, if required Adiabatic system The Adiabatic pre-cooling system includes: > High pressure pumping station > Embedded water filter upstream the pumping station > Water distribution systems to each coil > Stainless steel nozzles supporting bars > Pan to collect the unevaporated water, complete with discharge water circuit > Polyurethane coils protection panels Main maintenance and water quality recommendations > Biocide water treatment (or request) Water provided to the system must have the following characteristics: The following components need specific maintenance, in addition to the general recommendations included in the Operation and Maintenance manual. Feature Limit Conductibility < 1000 μs/cm PH 6.5 8.0 Chloride < 50 ppm Sulphate < 90 ppm Iron < 0.1 ppm Manganese < 0.1 ppm Aluminium < 0.1 ppm Component Protection panels Average Frequency 12 months(*) Pump station filters 4 months (**) Biocide (**) (*) Panels can be cleaned or replaced depending on the clogging rate (**) The frequency depends on water quality

To learn more about Schneider Electric cooling solution visit www.schneider-electric.com Schneider Electric Industries SAS Head Office 35 rue Joseph Monier 92500 Rueil Malmaison Cedex France Tel.: +33 (0)1 41 29 70 00 www.schneider-electric-com 2015 Schneider Electric. All Rights Reserved. Schneider Electric, Uniflair, are SmartStruxure are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners.