Lighting Control Panel

Similar documents
Planning and Installation Guide. Fifth Light System

Pow-R-Command 1000 universal I/O module

MechoSystems Shade Integration

Submittal Data Sheet WAGO Node for itm

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link

CS XL XM. EcoSystem Bus Supply

EcoSystem Digital Ballasts

LogicMachine5. LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire LM will enable you to

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

EISSBox OpenADR 2.0b

Multi-Point Gas Detection and Control System

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

Hotel Room Controller

Energi Savr NodeTM QSN-2ECO-PS120 EcoSystem with Shades ESN a

Energi Savr Node for DALI QSNE-2DAL-D DALI Fixture Controller V. Photo

EcoSystem to 0 10 V- Interface

Multi-Point Gas Detection and Control System

PHS Series. PowerHUBB Node - Satellite

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

SECTION DIGITAL LIGHTING CONTROLS

LogicMachine5 Power (LM5p-DW1)

Advanced Lighting Features For Today s Digital Lifestyle

Energi Savr NodeTM Programming Interface

PHM Series. PowerHUBB Node - Master/Control

Smart Equipment Controls (SEC)

Multi-Point Gas Detection and Control System

OMX-CI-NWK-E Control Interface

IntesisBox BACnet/IP Server DALI

Energi Savr Node with DALI for Quantum

QuantumR Light Management Hub

Lighting Systems. DALI Lighting Network Solutions. For comfortable, intelligent, efficient buildings

IEI emerge MicroNode Install and Setup Guide. Contents

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Multi-Point Digital Gas Detection and Control System

Switched Relay Controller - Relay Panel with Breakers

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Gas Controller System DGC-06

TPE 1464 Series Pressure Transducer

minilan-485 and minilan-232

SCD96 DMX Output Interface. Installation guide

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Distributed Power Series

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

SH2WEB24. Central unit module. Benefits. Description

INSTALLATION INSTRUCTIONS

SECTION ( ) LIGHTING CONTROL PANELBOARD

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

mark150s mark150/485s DDC controllers Summary

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

ARCHITECTURAL DIMMING PANEL - WITH NETWORKING

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

DTM Distributed Transmitter Monitor

SECTION SWITCHBOARDS

LDALI PLC4. Programmable DALI Controller. Functions. BACnet. DALI CEA 709 M Bus KNX OPC L WEB, L STUDIO L ROC L INX. L IOB IoT. Gateways L VIS, L-STAT

specifications: Metrolight SmartHID Electronic Ballast 100/150/ Watt - HPS 175/200/250/320/400/450 Watt - MH

S7999D SOLA Operator Interface Display

basicdim Wireless Wireless module for basicdim

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

QuantumR Light Management Hub (QP2)

VersaMax Micro and Nano Technical Product Presentation

Remote I/O Product Specification

PHS Series. PowerHUBB Node - Satellite

LDALI ME204-U, LDALI ME201 U

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

DIRIS Digiware D and C Communication and control power interfaces

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Remote I/O Product Specification

LogicMachine5 Reactor IO V2

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

CMSA-100 Manual. Cinema Media Server Automation

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

VAT series controller and transmitter. Manual

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P


HVAC Products. Introducing the SED2 Variable Frequency Drives

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

GreenMAX Relay Control Panels


System Installation guide

SA2WEB24. Central unit module. Benefits. Description

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Transcription:

Technical Data Lighting Control Panel Catalog# Project Comments Prepared by Date Type Overview Fifth Light s Lighting Control Panel (LCP) is used to control and operate all lighting devices using Digital Addressable Lighting Interface (DALI) and low voltage analog signals. It houses the local controller, lighting management software and various types of lighting interface modules. The Local Controller is an embedded computing device that runs the Lighting Management Software (LMS) and hosts the network and communication interfaces required to interact with third party systems such as Building Automation Systems and shade systems. The LMS is used to create lighting scenes for individual lighting or groups of lightings, define time-based, daylight-based, sensorbased, and manual lighting control strategies and monitor the health of DALI devices connected to the panel. The DALI Bus Chassis (DBC) houses 8 DALI Bus cards, 1 USB communication card and 1 power supply card. Each DALI Bus card can support up to 64 DALI devices. The DALI Bus card allows data exchange between the connected DALI devices and the USB communication card. Each DALI Bus card includes LED diagnostics indicators and commissioning DIP Switch. The USB communication card allows data exchanges between the DALI devices connected to all 8 DALI Bus cards and the Local Controller. The power supply card provides power to all the cards housed in the DBC. The Bus Coupler allows data exchange between the connected digital input cards and/or analog input cards. The digital input cards receive data from digital devices such as digital sensors and wallstations. The analog input cards receive data from analog devices such as daylight sensors. The Bus Coupler sends the data to the Local Controller via Modbus TCP. 24 VDC power supply to power the automation components hosted in the panel and external devices (ex: Touchscreens). Network switch allows LCPs to interconnect and form a lighting control network with a centralized lighting management system.

December 2016 Features Modular design capable to support up to 32 DALI Bus Cards, 48 digital input devices and 8 analog input interfaces hence providing lighting engineers and contractors the flexibility and scalability needed to support all sizes and types of lighting applications, i.e. from small or large facilities, fluorescent to LED, local to networked architecture. Intuitive web-based user interface allowing users to manage their lighting system from different computing platforms (desktops, laptops, smart phones, tablets) with access to the lighting network. Factory assembled and pre-wired Lighting Control Panel ready to be installed by the electrical contractor with minimal wiring and eliminating non-valued added on-site panel assembly and wire termination work. LED diagnostics indicators and built-in Commissioning Mode allowing contractors to easily test and commission the DALI Bus hence reducing the overall commissioning time of a DALI based lighting management system. Built to operate as a local Lighting Control Panel or as part of a distributed lighting control network with multiple lighting control panels and a Central Server Unit for a centralized management of large lighting control system. External PoE equipped commissioning port for use with commissioning access point. 2

December 2016 Specifications Performance Input Voltage: 120 VAC +/- 10% Operating Environment Dimensions Wiring & Mounting Communication Protocol Control Specification Maximum Load: LCPA: 5 Amps LCPB: 6 Amps Ethernet Ports: 5 Standards Input Frequency: 50/60 Hz Temperature: 32 F to 104 F (0 C to 40 C) Relative Humidity: 10% to 90% (non-condensing) For indoor use only LCPA: 23.6 H x 23.6 W x 9.8 D (600mm x 600mm x 250mm) LCPB: 31.5 H x 23.6 W x 9.8 D (800mm x 600mm x 250mm) Power: Wire-trap connections, use 12 AWG to 16 AWG solid/stranded wire DALI: Wire-trap connections, use 12 AWG to 20 AWG solid/stranded wire Digital and Analog Input: Wire-trap connections, use 12 AWG to 20 AWG solid/stranded wire Network: Ethernet (RJ45, CAT 5/5e/6 wire types) Grounding: Ground terminal must be connected to earth ground Mounting: NEMA 1 surface mount BACNet, DALI, Modbus TCP/IP, XML DALI Bus Chassis: Power Supply Card(s): 1 Communication Card(s): 1 DALI Bus Card(s): 8 Input Voltage: 24V Maximum Input Current: 3 Amps (24V input) DALI Bus Card: Communication Interface: Digital Addressable Lighting Interface (DALI) DALI Output Voltage: 18V (14V - 20V, depending on DALI Bus load) DALI Output Current: 160 ma DALI Addresses: Up to 64 LED Indicators: 7 (Power, USB link, USB activity, DALI power, DALI activity, Status, Mode) DALI Input Voltage: 9.5 VDC - 22.5 VDC per DALI Bus Modbus Coupler: Up to 48 Digital Input devices and 8 Analog Input devices with 30 ms read/write capability Mode: Unmanaged Input Voltage: 24 VDC Data Transfer Rate: 10BaseT/100BaseTX Dimensions (Inches/mm) LCPA: 23.6 H x 23.6 W x 9.8 D (600mm x 600mm x 250mm) LCP A LCPB: 31.5 H x 23.6 W x 9.8 D (800mm x 600mm x 250mm) LCP B Wiring Diagram 3

11:46 06/26/09 1000 FIFTH LIGHT TECHNOLOGY 1 10% 2 10% 20% 3 30% 4 40% Units Are: 1027.1028 LIGHTS GROUPS SCENES SUPPORT Scene 1 Scene 2 Scene 3 Scene 4 December 2016 LCP Panel Wiring 120 VAC INPUT POWER POE COM PORT TO CENTRAL MANAGER OR NETWORK SWITCH TO LOCAL CONTROLLER TO COM PORT NNote: Sample wiring diagram for a LCPA model Notese: 1. Refer to Electrical Contractor Testing Protocol document for detailed information with regards to the DIP Switches and LED indicators located on the DALI Cards. 2. Drilling should be done on the removable gland plate at the bottom of the panel. Aviod drilling top/sides of the panel as metal shavings will damage internals. Sample System Topology DALI COMMUNICATION BUS Maximum of up to 64 devices on each DALI Bus. All devices must be within 900 feet of the Lighting Control Panel (LCP). 16/2 AWG recommended wire. DALI FIELD RELAY DALI DIMMABLE BALLAST DALI MULTI SENSOR DALI DAC 0-10 VDC DALI DIMMING MODULE DALI WALLSTATION DALI RELAY PANEL LIGHTING CONTROL PANEL VOIP PHONE TOUCH SCREEN MOBILE APP NETWORK SWITCH ETHERNET CENTRAL MANAGER 4

December 2016 Ordering The following ordering configuration is for standard Lighting Control Panels that will meet the needs of typical installations. The number of DALI Buses and the number of digital and analog inputs. An LCP and Local Controller feature list can be found on page 2 of this specification sheet. Sample ordering structure is below: LCP# - ##DALI - ##DI##AI - ## Panel Size LCPA = Supports 8 or 16 DALI Buses LCPB = Supports 8, 16, 24 or 32 DALI Buses Additional Options Number of DALI Buses Each DALI Bus supports and powers 64 DALI devices 08 (LCPA or LCPB) 16 (LCPA or LCPB) 24 (LCPB) 32 (LCPB) Digital/Analog Input Options 00DI00AI 08DI00AI (Can be installed in an LCPA with 8 DALI Buses or an LCPB with up to 24 Buses) 08DI08AI (Can be installed in an LCPA with 8 DALI Buses or an LCPB with up to 24 Buses) 16DI00AI (can be installed in a LCPB with 16 and 24 Buses) 16DI08AI (can be installed in a LCPB with 16 and 24 Buses) 24DI00AI (can be installed in a LCPB with 16 and 24 Buses) 24DI08AI (can be installed in a LCPB with 16 and 24 Buses) 48DI00AI (Can be installed in an LCPB with up to 16 Buses) 48DI08AI (Can be installed in an LCPB with up to 16 Buses) Pre-Wiring ST = Standard with no pre-wiring EX = Expandable with pre-wiring Catalog # Description FLT-LCPA-PS 10A power supply for LCPA panel, 24 VDC, 120-240V FLT-LCPB-PS 20A power supply for LCPB panel, 24 VDC, 120-240V FLT-DBC001 DALI Bus Chassis for LCP FLT-CTL001 Local Controller FLT-LVDIKT Fifth Light DI Input Card, 8 Terminal Blocks, Wiring FLT-LVAIKT Fifth Light AI Input Card, 8 Terminal Blocks, Wiring FLT-LVBCKT Fifth Light Bus Coupler, End Card, Wiring FLT-LVPIKIT Fifth Light Partitioning Input Card, 4 Terminal Blocks, Wiring Notese: 1. LCPB with 32 DALI Cards can only be ordered with the 00DI0AI option. Expandable option includes all wiring and terminated blocks required to allow the electrical contractor to easily add a new DBC. 2. A dedicated digital input channel is required per LCP for systems requiring integration with a fire alarm system contact closure. 3. All third party DALI ballasts and drivers shall be IEC 62386/DALI Ed 1 compliant and must not respond in any way to frames other than the 16-bit frames as defined in the published standards (IEC 62386 parts 101, 102, etc ). The DALI frame used by these devices must be encapsulated by the IEC 62386 defined start bit and the defined two stop bits to be considered a valid frame. To reduce project risks, Eaton recommends using the third party DALI ballasts and driver listed on the Fifth Light verified ballasts and drivers application note which can be found on. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 For service or technical assistance: 1-800-553-3879 2016 Eaton All Rights Reserved Printed in USA Publication No. TD503057EN December 8, 2016 Specifications and dimensions subject to change without notice.