WALKING TEST KIT WT5000

Similar documents
TEST AND MEASUREMENT SRM 200 SRM 200/EFM 51 STARTERKIT

ELECTROSTATIC FIELDMETER

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

OX 5022-CK OX 5042-CK

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

User's Guide. MiniTec TM Series Model MN25 MultiMeter

PRODUCT. Data Sheet. The new Fluke-289 Advanced Logging Multimeters with Trend Capture

Wrist Strap & Shoe Tester WST 100

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Analog BV15 transmitter U16/14-100k. Manual

MANUAL. Handgelenksband WST 100. Handgelenksband- und Schuhtester. performance test for Electrostatic Wrist Straps and Conductive Shoes

Mini Digital Multimeter

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

PGT 120. Personnel Grounding Tester. Wrist Strap and Footwear Tester. Users's Manual

Operating Instructions

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Operating Instructions

User's Guide. Digital Multimeter. Model MN42

DPL4000 Portable Low Range Dew Point Analyzer

IP 20. Rated. with terminals

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

User's Guide. Extech AM A AC Analog Clamp Meter

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Mini Digital Multimeter

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

2020 System Calibrator

C100 Portable Multifunction

Advanced, Cost-effective, and Reliable HART Communication Products

Keysight U1610/20A Handheld Digital Oscilloscope. Quick Start Guide

Model A Mini AC/DC Clamp Meter. User's Guide

USER'S MANUAL DCL-650

Line Impedance Stabilization Network (LISN)

Earth Resistance and Resistivity Tester

10A Micro-Ohmmeter Model 6240

Druck DPI 620 advanced modular calibrator

2 in 1 LAN Tester and Multimeter Model:

TC 6621 / TC Temperature test tools CALIBRATION. Measure and generation Protected for on-site use Perfect for control and tests

HT-1A Dual Band CW QRP Transceiver. User Manual

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

7032 Digital-Analog Multimeter

TTC Series Torque Tool Tester Operation Manual

PRODUCT. Data Sheet. Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture

EATON 5S 850/1200/1600

Mini Digital Multimeter

Megohmmeter Models 6550 & 6555

power quality Models 8230 & 8220

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

MTP INSTRUCTION MANUAL

Multi-Function Ground Resistance Tester Model 6471

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

Hand-held thermometer Model CTH7000

AGATE TECHNOLOGY AT-2040

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

PRODUCT INSTRUCTIONS MODEL SR-2 SOIL RESISTIVITY METER

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

DVC-350C CALIBRATORS, INC HANDHELD BATTERY-POWERED VOLTAGE CALIBRATOR FEATURES INTRODUCTION GENERAL DESCRIPTION

7561-PSD Manual Portable Battery Powered Indicator

Digital Clamp Meter User Manual

FG-7000 Digital Force Gauge Operation Manual

Chapter 5 Review. Power Supplies

Introduction. Chapter 2

LeCroy PP009 Passive Probe Instruction Manual

D8000 SERIES QUICK START GUIDE

Portable Multi-Function Calibrator Model CEP6000

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

PRODUCT INSTRUCTIONS MODEL SR-2 SOIL RESISTIVITY METER

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Power Analyzer Datalogger Model

Power Prowler. Quick Start Guide. 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables 600V CAT III. For Live Energized Cables

Operation Manual for USB Autoscope Lite. Contents. USB Autoscope Lite Operation Manual

User s Guide. 600A AC Clamp Meter. Model 38387

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

PowerMust Office Uninterruptible Power System

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Programming SureStart

Three-Phase Power Quality Analyzer PowerPad Model 3945

LOW WEIGHT, SMALL SIZE,

700 Series 200 Amp Clamp Meters

C.A 6165 Appliance multitester

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Operating Instructions

Bearing (Shock Pulse) Condition Analyzer -110

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

1 Commissioning (basic settings and calibration)

1-36V, 0-3A DC Power Supply

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

A P P L I C A T I O N

DH GHz Digital Wireless Headphone. User s Manual. Please read before using the equipment. Please visit for details.

MobilControl MC 4000 OWNER S MANUAL

ETHOS Auto Ranging Digital Multimeter

FG-7000L Digital Force Gauge Operation Manual

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

Transcription:

reliable & caring since 1976 WALKING TEST KIT WT5000 Walking Test Kit, includes: a WT5000 electrometer, A/D converter with software, hand-held probe, connecting cables, conductive carrying case, user s instruction in German and English and calibration certificate. The graph of the body voltage measurement will be displayed online on the connected PC or LAPTOP. Electrometer WT5000: Test range: ± 5.000 volts or ± 500 volts Accuracy: 5% of measured value Input resistance: > 10 14 ohm Input capacitance: < 5 pfarad Display: Output: Operation: Logarithmic LED-display ± 500 volts, changeable to ± 5.000 volts, Peak hold Analog ± 5 volts for each test range Rechargeable batteries (battery charger included) Complies with IEC 61340-4-5 TEST AND MEASUREMENT Part Nr. 7100.WT5000.B Walking Test Kit - USB-Version Includes: Electrometer WT5000 A/D converter UAD1 with USB connector Data acquisition and analysis software "Digilloscope" for Windows Handheld probe Teflon insulated cable 4 NiMH rechargeable batteries Charger Conductive carrying case WALKING TEST BODY VOLTAGE MEASUREMENT Product link Body voltage measurement test set-up. The new software Digilloscope" can mark the five highest peaks automatically and calculates the average value. ANALOG/DIGITAL CONVERTER The UAD1 can be used with the following instruments: WT5000 (see above) ESVM1000 and ESVM2000 (see page 80) includes Data acquisition and analysis software "Digilloscope" for Windows Part Nr. 7100.UAD1 Analog/Digital converter with USB connector - UAD1

User's Manual Walking Test Kit 7100.WT5000 Wolfgang Warmbier Untere Gießwiesen 21 D-78247 Hilzingen/Germany www.warmbier.com

Table of contents Overview...2 Technical data...3 Operation...3 Controls and displays... 3 Function keys... 4 "Peak Hold" function... 4 Measuring range... 4 Trouble Shooting...4 Only a horizontal line is visible after starting the measurement... 4 Your computer does not have the parallel port to insert the A/D-Converter... 4 Maintenance...5 Battery charging and replacement... 5 Zero adjust... 5 Warranty... 5 Notice...5 Calibration...5 Preparation...6 Connecting the components... 6 Software installation... 6 Setup... 6 Measurement...7 Measuring... 7 Overview The Walking Test Kit described below, is used to monitor the body voltage on a person. The voltage is taken from the electrometer through the A/D-converter and displayed on a PC or a laptop. The kit consists of: Electrometer WT5000 Analog/Digital-Converter Pico 42M Data acquisition an analysis software PicoScope Handheld probe Connecting cable and plugs Conductive carrying case Page 2 / 7 Edition: Nov. 2006

Technical data Electrometer Dimensions: 190 x 148 x 67 mm (L x W x H) Weight: ca. 500g Input voltage: ± 500V / ± 5000V Input impedance: >10 14 Ω Input capacity: < 5 pf Response time: 10 ms Output: Analog ± 5V Display: 21-digit logarithmic LED display with "Peak Hold" Power supply: 4 pcs. NiMH rechargeable batteries (AA) Operating time: 4 to 6 hours Charger: 7,5V DC, 300 ma Ranges: ± 500V, ± 5000V Accuracy: < 5% Battery monitoring: audible A/D-Wandler Input impedance: Interface: Input voltage: Resolution: Max. sampling rate: Power supply: 1MΩ Parallel printer port, (USB with optional adapter) ± 5V DC 12 Bit 15 khz via printer port Operation Controls and displays Front side Back side ( 1) Measurement input ( 7 ) On-/off button ( 2) Input range indicator LED x10 ( 8 ) Power supply socket for the charger ( 3) Input range selector ( 9 ) Grounding socket ( 4) Trimmer for zero adjustment ( 10 ) Analog output (BNC socket) - Analog signal for the A/D-converter ( 5) "Peak Hold" reset button (6) 21-digit logarithmic LED display Page 3 / 7 Edition: Nov. 2006

Function keys On/Off ( 7 ) Range ( 3 ) Reset ( 5 ) Button to switch the instrument on and off. A beep signal sounds on power on. When not used, the instrument switches off automatically after 15 minutes. Selects input range ±500V or ± 5000V. The higher range is indicated by the green "x10" LED Resets the "Peak Hold" display "Peak Hold" function The last measured positive and negative peak value is held on the LED display until it is reset with the "Reset" button. Measuring range The two measuring ranges can be switched with the "Range" button. When switched on, the instrument's range is ± 500V. Pressing the "Range" button will switch to ± 5000V. The according range is displayed by the green x10 LED. Changing the range will also change the output resolution of the analog output. This has to be taken into account during measurement. Range Output Multiplier ± 500V ± 5V 100 ± 5000V ± 5V 1000 Trouble Shooting Only a horizontal line is visible after starting the measurement. For proper A/D-Converter operation the Parallel port of the computers BIOS must be set to Normal, Unidirectional or SPP. Please check the BIOS setting. To enter the BIOS setup press and hold one of the keys DEL, F1 or F2 Taste while switching the computer on. Your computer does not have the parallel port to insert the A/D-Converter You can use the optional available USB to Parallel Converter.USB to connect the A/D-Converter to the USB-Port. Page 4 / 7 Edition: Nov. 2006

Maintenance Battery charging and replacement An audible signal indicates a battery low state. Plug in the power supply to charge the battery when necessary. The battery is located inside the battery compartment underneath the instrument. Only NiMH rechargeable batteries Type (AA) are allowed for this instrument! Zero adjust Zero adjusting is normally not necessary. If the unit does not indicate 0V while the input is connected to ground, the zero adjustment trimmer (4) can be used to for adjustment. Warranty Warranty does not include the NiMH rechargeable battery, damage of the battery due to drain, and mechanical damage of the instrument. The warranty is void if the unit was opened. Notice This instrument is not approved for measurements in explosion hazard areas. The electrometer must always be grounded during measurement. Using the instrument in power plants is not permitted. The electrometer is not equipped to detect alternating fields > 100 Hz. Calibration The recommended calibration interval is 2 years. Page 5 / 7 Edition: Nov. 2006

Preparation For data acquisition and storage the PicoScope software has to be installed on a Computer with Windows operating system and the A/D-converter must be connected to the parallel port. Connecting the components 1. Plug the A/D-converter into the 25-pin D-SUB socket of your computer's printer interface LPT1. 2. Connect the A/D-converter to the electrometer using the BNC-cable. 3. Connect the earth terminal of the electrometer to earth using the crocodile clip of the grounding cord. 4. Connect the handheld probe to the electrometer using the Teflon-insulated wire. 5. Charge the battery of the electrometer with the external power supply if required. Note: The computer must be connected with the electrometer during the whole measurement. Software installation Run the installation program webpsw32.exe on the enclosed CD-ROM. If your operating system is Windows NT, XP or 2000 you must run the setup program as administrator. After selecting your language you have to confirm the license agreement and select a path for installation. After that you are asked to select your Operating System, the Product ADC-42 and port LPT1. The software group PicoScope should be checked. After specifying a program group the installation is completed. You must restart your computer before running the program. Setup Run the PicoScope program and load the initial setup file with File - Open. Select the CD-ROM drive and open the file wt5000_setup.psd. To store the settings permanently, select File - Safe Settings. Page 6 / 7 Edition: Nov. 2006

Measurement Measuring Set the X-Scaling to 1s/Unit Set the Y-Scaling to either ± 5000V or ± 500V appropriate to the setting of the Electrometer. Start measurement with the green GO-button in the lower left corner of the window. Zoom x= Cursor 1 Cursor distance 249 ms o= Cursor 2 Start- / stop button Perform the Walking Test and stop measurement afterwards with the red STOP button. The measurement data is rolling continuously on the screen during measurement. Move the cursors as shown in the picture to measure the curve. Drawing a vertical or horizontal line at the appropriate position will set a cursor. Store the measurement with File - Save. Choose Drive «C:», file-type «Data Files (PSD)» and enter a filename. Copy the graph to the clipboard using Edit - Copy as Graph to insert it into other applications. Adjust Y-Scaling Function "x10" not active Function "x10" must be active Page 7 / 7 Edition: Nov. 2006