AC-DC Converter REC /60-K20

Similar documents
AC-DC Converter RECE K21

AC-DC Converter REC K10

RT4B-110V/12A RECTIFIER

RT4F-120V/20A-WAC RECTIFIER

RT4F-110V/25A RECTIFIER

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

LBC Series 3-phase PSU / Battery Charger

RT12-240V/2.4kW Rectifier Specification

RT4F-48V/50A-WAC RECTIFIER

PRODUCT FEATURES AND ADVANTAGES

CSPS-6K (Shelf Type) POWER you need POWER SHELF

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MAJOR VA Power Inverter

PHOENIX CONTACT - 01/2007

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

MINI-PS AC/10-15DC/8

SLI 15 INVERTER SERIES, 1500 W

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

Series Watt DC Power Supplies

Industrial Power Supplies

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

RT9-48V/1.4kW Rectifier Specification

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

24/48V Battery Bank Ah High Cycling Long Life

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUINT-PS AC/24DC/10

QUINT-PS/ 1AC/24DC/ 5

VIDI System Controller

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

DC POWER SUPPLIES DNX 110/220 V

DPA UPSCALE TM RI kw Technical Specifications

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

RT7-48V/6kW Specification

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

TECHNICAL DESCRIPTION

Contact protection relay

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

Technical Manual Nova: Cabinet Security Management System (CSMS)

MC 11 EB-2 Power supply cabinet with external bus, AC version

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

SMARTONLINE E3 UPS SYSTEMS

Industrial Power Supplies

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

A0750 AC-DC POWER MODULE

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

Industrial Power Supplies

SITOP in the SIMATIC Design

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

Milpower Source M359-1 is a ruggedized, high performance On-Line UPS designed for Naval Shipboard and tough industrial applications.

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

UPS Series. features: uninterruptible power supply. what great systems are built on.

Voltage Current Front-mounting bracket

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

VLT 2800 DRIVE SPECIFICATIONS

DATASHEET. Ultra Capacitor Charger, UCC-4

Universal Power Supplies

SITOP 3-phase 24 V DC, 20 to 40 A

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

FMP VDC RECTIFIER 42 Amps 2000 Watts

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Simple but elegant look and ease of installation make it ideal for various industrial applications.

Uninterruptible Power Supplies

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

SIMOCODE 3UF Motor Management and Control Devices

Intelligent On-Line UPS

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Rhino PSM Power Supplies. Operating Instructions

PCU Supervisory module for the RM 1000 series

Output Voltage* (nom.)(adjustable)

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

GUARDIAN ACCESS MODELS GDN.S.48.M24 & GDN.S.48.MS32 Integrated DC Power System & Battery -48VDC 500A 26.8kW

METERING/DISPLAY MANUAL

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

VersaMax IP I/O Module

Switched Mode Power Supply Operating manual PAP800

Switch Mode Power Supply S8VT 120/240/480/960 W Models

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

PSC600-series DC/DC W

Transcription:

Thanks to the variety of modules available, the REC3200-230-48-K20 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter System Starting up from a minimum equipment of 600Watt, the system can be expanded with additional modules to a higher-performance or even redundant system to grow with the requirements of your application. With the controller monitoring and remote control functions which can be easily integrated, the REC3200 system permits the design and setup of system solutions appropriate for example for outdoor telecommunication systems. 19, 3HE basic module, also appropriate for installation in ETSI racks or cabinets Redundant rectifier modules, 600W/800W Inverter module for AC Out Two redundant Battery modules for UPS function Short-term UPS based on Super-Cap s Electronic distribution with shutdown-function Comprehensive Controller functions covering alarm contacts, LAN access, SNMP and WEBinterface AC and DC connection at the front Electronic data Input Mains voltage Voltage range Frequency range Mains connection Commercial power line Electronic data Output Output voltage U N = 230V AC, 50/60Hz +/-20% (184 276V AC) 45-66Hz, sine wave-form 1-3-phase TT and TN-Netz acc. to EN60950 48V DC, potential free Output power 600W - 3200W, depending on degree of expansion without derating up to ambient temperatures of 60 C Output voltage tolerance Temperature controlled battery loading characteristic Output characteristic UI characteristic Output ripple <100mVpp Efficiency >90%, at nominal load Parallel operating Redundant decoupling of the 600W/800W modules with diode funtions Load sharing Activ, accuracy ±10% Mechanical data Version Dimensions Weight: Subrack Controller Distribution panel Single rectifier Cooling Rectifier module Appropriate for installation in ETSI- and 19 racks (flanges can be changed) 19 x 240mm x 3HE (W x D x H) approx. 12kg approx. 1,5kg Horizontal forced ventilation with fan failure detection 1 / 8

Modular Battery Charger / Inverter System Protection functions EMV, safety AC Input DC Output Overvoltage acc. to EN61000-4-1 (VDE 0160): 750V AC 0,1/1,3ms Overvoltage protection, repetitive trace function, tripping value <=60V DC (<=72V DC) Emission Immunity to interference EN55022, class B EN55024, EN61000-6-2 (industrial area) Leakage current Fixed protection earth (PE) connection is obligatory. At AC connection via contact plug an additional PE connection is not necessary. Environmental conditions Connection terminals AC Input DC Input DC Output, OUT 1-3 Alarms/Signals Phoenix HDFK4 3-phase Battery connector: Phoenix HDFK10 Phoenix HDFK16 Remote control + LCT 2 x RJ 45 D-SUB, 44-pole, female Isolation group Ambient temperature durig operation Maximum ambient temperature Relative air humidity Acc. to EN60950, pollution degree 2-25 C to +60 C +70 C, beginning from +60 C derating with 2,5% per 1 C 0% to 100%, operation after drying Protection IP 20 Signals Optical signals: Controller Rectifier Alarm contacts LED red: Alarm : OK : AC OK : DC OK 2 programmable, potential free alarm contacts, contact load max. 60VDC, 500mA via signal connector Warranty 24 months REC3200-230-48/60-K20 2 / 8

MREC600 modules for installation in the REC3200 sub rack are hot pluggable, i.e. they can be mounted in the sub rack or extracted during operation. The decoupling of the DC bus system and the active load sharing of individual modules with the resulting module redundancy provides a system with a very high availability Power Rectifier module for REC3200 Electrical data Output Nominal voltage 40V DC - 60V DC, CAN bus controlled Output voltage Max. 600W Signaling DC o.k. AC o.k. Constant power range Output current Efficiency Output characteristic Output ripple Parallel operation Load sharing 40V - 60V Max. 15A >92% at nominal load UPI characteristic, transit from P to I at <= 33V DC <100mVpp Redundant decoupling of 600W modules with diode function Active, accuracy +/-10% Warning: The MREC600 and the MREC800 cannot be mixed in one System. MREC600-230-48-K9 3 / 8

MREC600 modules for installation in the REC3200 sub rack are hot pluggable, i.e. they can be mounted in the sub rack or extracted during operation. The decoupling of the DC bus system and the active load sharing of individual modules with the resulting module redundancy provides a system with a very high availability Power Rectifier module for REC3200 Elektrische Daten Ausgang Nominal voltage 40V DC - 60V DC, CAN bus controlled Output voltage Max. 800W Signalisierung DC o.k. AC o.k. Constant power range Output current Efficiency Output characteristic Output ripple Parallel operation Load sharing 40V - 60V Max. 16A >92% at nominal load UPI characteristic, transit from P to I at <= 33V DC <100mVpp Redundant decoupling of 800W modules with diode function Active, accuracy +/-10% Warning: The MREC600 and the MREC800 cannot be mixed in one System. MREC800-230-48-K9 4 / 8

The Controller module is used for controlling and monitoring the REC3200 modules via the internal CAN bus. The Local Craft Terminal (LCT) LAN interface permits the connection of a local PC or network. A clear and easy-tooperate user interface facilitates control, programming and linkage of all controller parameters depending on user requirements. Controller module for REC3200 Further features: Hot plug-in capability No AC/DC power supply interruption in case of a controller failure Output voltage control via temperature dependent charging characteristic External alarm inputs RS232 for external modules Freely programmable alarm relays PCBs protected against humidity Electric meter for MBUS / RS232 Integrated SNMP function and Webinterface Signals Interface RS232: for external sensoren (12V auxiliary voltage) e.g. RFID card reader e.g. smoke or gas sensors Temperature measurements with PT1000 (2x) Switching outputs for external components 8 alarm inputs e.g. door contacts e.g. Temperature alarms Alarm outputs - Freely programmable - Floating (potential free) Battery measuring input for downward compatibility to MCON2400-230-48 Signaling o.k. LED red Alarm (general alarm) Local Craft Terminal (LCT) Connector RJ45 Protocol TCP/IP LAN Connector RJ45 Protocol SNMP and Webinterface Connector D-Sub HD 44 Mini Combicon 2x6pol MCON2400-24-85-K20/K21 5 / 8

The battery connection module is required for connecting a battery to the REC3200 system. It includes the battery connector, battery fuse and LVD as well as the control logic for the battery management. Functions such as symmetry monitoring, current measurement and temperature characteristic are integrated. Battery connection module for REC3200 Further features: CAN-Bus controlled Programmable charging characteristic Programmable LVD relay Battery temperature detection Automatic battery test Battery connection Signals Nominal voltage Temperature sensor Fuse 48V DC PT1000 2-pole, Magneto-hydraulic Alarms Adjustable and analyzable by means of the controller operating software Max. output current 50A Symmetry measurement Mini Combicon 6-pole Phoenix MC1,5/6-GF-3,81 10k in the line Deep-discharge protection Via LVD Battery connector HDFK 10 Recommended power reserve for battery charging 500W MBATT2400-48/60-K20 6 / 8

The connection module permits an electronically controlled distribution via six DC outputs. Each output is electronically overcurrent-protected. The tripping current is adjusted via the software. After tripping, the output can be reset manually by means of a push button. Alternatively, a reset is also possible via the management system. All outputs can be switched individually. To save battery capacity, certain outputs can be switched off for example by means of a time-control command or triggered by a power supply failure. In this case, the shutdown can take place immediately or with a certain delay. The power available at the outputs can be measured. Further features: Electronic connection panel for REC3200 CAN bus controlled All six outputs are electronically protected Programmable tripping current Power measurement at each output Outputs separately switchable Manual reset Function display via LED Outputs DC OUT, 1-3 DC OUT, 4-6 Max. sum current Plug connector Signaling LED red adjustable from 0-8A, electronically adjustable from 0-6A, electronically 30A Type 3W3 Operation Failure, shutdown Reset Manually via Reset button or Remote via monitoring software (Protected against unintentional actuation) MSICH-K9 7 / 8

Inverter module for the REC3200 System for a secure and uninterrupted supply of AC units. The MINV500 plug-in module provides a 230V AC, 50Hz sine-wave output signal supplied by the DC bus system. The connection to the power supply is set up via the front of the module. Inverter module for REC3200 Further features: CAN bus controlled Hot plug-in capability Temperature range -25 C to +70 C Controlled and monitored fans PCBs protected against humidity Real SINE output Short-circuit protected Electrical data Output Output voltage Frequency Output power Power factor 0,8 230V AC Crest factor >2,5% Harmonic factor <2,5% 50Hz, sine-wave processor controlled 500VA / 400W Load range 0% - 100% Overload range 101% - 150% at 30sec. to 3sec. Connector terminals Output Signals LED yellow LED red Phoenix MC1,5/3-6F-5,08 Output o.k. Warning overtemperature Output switched off (Overload or overtemperature) Effieciency >88% at nominal load MINV500-48-230-K1 8 / 8