Portable Data LOGGING SYSTEMS. for Professionals

Similar documents
MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS


multichannel CONTROLLERS data recorders

CMC-99 (RS ) multichannel CONTROLLERS data recorders

horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized measured values

Hydrostatic filling level sensor HFB C4 / R / MD

multichannel CONTROLLERS data recorders

ENVIRONMENTAL MONITORING & CONTROL

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

LBVR1718. Description. Features channel paperless recorder

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

ENVIRONMENTAL MONITORING & CONTROL

SX 6000 Paperless Recorder

MULTICHANNEL CONTROLLERS, DATA RECORDERS

DS 500 Intelligent chart recorder for compressed air and gases

PI 500 Hand-held instrument for industry

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

IDS 500 mobile Intelligent mobile chart recorder

PCPR01 Paperless Recorder

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

DMT345 and DMT346 Dewpoint Transmitters

LAUREL ELECTRONICS, INC.

KBL Brochure. Electronic Multi-Channel Datalogger

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Neon pr. ph/ ORP measurement. Applications. Description

INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION MODULES CMC-99/141

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

MULTICHANNEL CONTROLLERS, DATA RECORDERS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

D E C E M B E R

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

CLEAN ROOM PANEL - CRP5

Refrigerated incubators with forced convection

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Millenium II +: general characteristics

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Catalogue for measuring professionals

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Dräger Polytron 8200 Stationary gas detector (CatEx)

LAUREL ELECTRONICS, INC.

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

DIAGNOSTICS PN# / / FSP

Data logger systems from ROTRONIC

CLA-VAL Control Panel

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

System concept. Hardware DATA SHEET VECTRON POS TOUCH 12 LIGHT

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

F1000 User's Manual. (Version: V1.01)

Visit to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Conductivity Transmitters

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Catalogue for measuring professionals

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

MMT330 Series Moisture and Temperature Transmitters for Oil

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

CHP GAS MONITOR GDR 1404

Industrial Wet/Wet Differential Pressure Transducer

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

CALogix MODULAR LOGIC AND PROCESS CONTROL

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

User manual DATA RECORDER SRD-99

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

HMISCU6B5. Main. 60 right 40 top 60 bottom

DS 500 Intelligent chart recorder for compressed air and gases

VPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement

USB-500/600 Series Low-Cost Data Loggers and Accessories

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Multi Channel Data Logger

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

AWARD WINNING PRODUCTS AND SERVICES TAKING OUT COST AND INCREASING OPERATING EFFICIENCY

BACnet Controller for General-purpose Building Applications

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Technical Catalogue Softstarters

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital Indicator Solutions

User manual for controller/data recorder. MultiCon CMC-99/141

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

RE92.CHECKMATE. Dual loop controller for industry purpose. measuring inputs. Automatic parameter selection according to the controlled object

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

CCD1100S. Technical Data Sheet

USER MANUAL for. Loggy Soft v or higher. S-Toolkit v or higher SRD-99 - X X

Verderflex. Vantage Description. Your benefits. Technical specifications. Materials

Digital electropneumatic Positioner for the integrated mounting on process control valves

Transcription:

Portable Data LOGGING SYSTEMS for Professionals

Introduction SIMEX is a Polish manufacturer and supplier of industrial automation equipment. The company has been in the market for nearly 0 years and offers services provided by a team of young and qualified professionals, both designers and programmers, as well as sales representatives. We specialise in the production of devices from the following categories: counters, indicators, controllers while concentrating on data recorders. In the offer you will find two families of high quality products for data recording: MultiCon and a series for the less advanced processes - MultiLog. Both devices are designed for stationary measurements. What s new is the portable case for these products, which allows transporting them from place to place. This is a significant advantage, because stationary recorders gain features of portable recorders and at the same time retain the capabilities for advanced measurement and recording of the tested media. In addition, the sealed case made by PELI protects the devices from damage. Applications - Recording the operating parameters in water and sewage pumping stations - Recording the operating parameters in heat chambers and heat exchange units - Pressure control of hydrophore stations - Recording changes in river levels Mine Military Pump station Extreme conditions Water treatment plant Hydrophore station Sewage treatment plant Heat exchange unit

Portable case - the advantages Protection of electronic equipment and valuable recorded data is a growing concern. This is particularly important in non-stationary solutions, when measuring instruments are mounted in portable, sealed transport cases, which are the only barrier against the harsh environmental conditions. Therefore, this case must meet a number of requirements guaranteeing the safety of the devices installed in it, and hence the reliability of this type of data recorders. In the sets offered by our company we use PELI cases, which is a proven and reliable solution in the transport and storage of sensitive measuring instruments for professionals. Heavy duty fins are engineered to protect latch and hinge areas. The double-step latches are smart and make the PELI case easier to open. Technological holes allow for lock or seal set up to increase safety in the event of data theft attempts. The neoprene o-ring keeps the case totally watertight. Big-fold down and rubberized handles. Stainless steel pins are used in hinges, latches and handles to prevent corrosion. Twin-ribbed top surface. Automatic pressure equalization valve releases air from the interior while keeping water molecules out, ensuring IP 67 protection class. Ultra High Impact Copolymer Polypropylene is extremely strong and flexible against external impacts. Extra thick 5, mm wall construction provides significantly greater strength to weight ratio over conventional injection moulding.

P0-CMC-99 P0-CMC- up to input/output/communication connectors colour display with touchscreen, TFT.5 or 5.7 RS-85 or Ethernet communication tight IP 67 case MultiCon CMC in a P0 portable case is a combination of a multichannel controller/data recorder with a sealed waterproof and dustproof housing. This combination gives you the ability to safely perform measurements and record data in particularly demanding and difficult applications, for example, in field conditions with high dust, high humidity or high risk of flooding the device. The main advantages: - USB Host port for retrieving data, - waterproof and dustproof housing, designed to work in conditions of high humidity, high temperature jumps, dust, pressure differences, etc. - free recording software. Portable version of MultiCon CMC series data recorder works wherever there is no need or possibility to install stationary devices. Portable case is equipped with all necessary connectors with IP 67 protection degree for of sensors, allowing for autonomous operation of the recorder under harsh environmental conditions. By equipping the case with communication interfaces: Ethernet and/or RS-85, the MultiCon CMC can provide measurement data to a PC or a host system. SET CONTENTS - PELI portable case, - MultiCon CMC-99 or CMC- controller/data recorder, - power cable, - connectors (socket-plug) for sensors and communication links in the ordered amount. Optionally: - DAQ Manager Software CD Box, - LKS-99/ licence key for data logging, - MS- ( GB) or MS-8 (8 GB) mini pendrive USB.

TECHNICAL DATA CMC-99 in portable case CMC- in portable case Power supply 9V 50V DC, 6V 5V AC or 85V 60V AC/DC, 50-60 Hz 9V 50V DC, 6V 5V AC or 85V 60V AC/DC, 50-60 Hz Inputs / outputs type up to input/output connectors: universal, analogue (0/ 0 ma, 0/ 5V, 0/ 0V), termocouple (J, K, S, T, N, R, B, E, L, ± 5 mv, ± 00 mv, -0 5 mv, -0 00 mv), resistance (Pt00, Pt500, Pt000, Pt'50, Pt'00, Pt'500, Ni00, Ni500, Ni000, Cu50, Cu00, Cu'50, Cu'00, 0 00 Ω, 0 kω), counter/ flowmeter/ ratemeter, digital up to input/output connectors: universal, analogue (0/ 0 ma, 0/ 5V, 0/ 0V), termocouple (J, K, S, T, N, R, B, E, L, ± 5 mv, ± 00 mv, -0 5 mv, -0 00 mv), resistance (Pt00, Pt500, Pt000, Pt'50, Pt'00, Pt'500, Ni00, Ni500, Ni000, Cu50, Cu00, Cu'50, Cu'00, 0 00 Ω, 0 kω), counter/ flowmeter/ ratemeter, digital Sensor supply output V DC ±5% / max. 00 ma V DC ±5% / max. 00 ma Communication interfaces options: RS-85, Modbus RTU, 00 500 bit/sec., Ethernet options: RS-85, Modbus RTU, 00 500 bit/sec., Ethernet Display TFT.5 ; colour, graphic TFT, 0 x 0 pixels, with touchscreen TFT 5.7 ; colour, graphic TFT, 0 x 0 pixels, with touchscreen Memory capacity Data recording speed internal,5 GB from 0. s to h with resolution 0. s internal,5 GB from 0. s to h with resolution 0. s Protection class IP 67 IP 67 Operating temperature 0 C +50 C (optional -0 C +50 C) 0 C +50 C (optional -0 C +50 C) Weight.5 kg (case. kg).5 kg (case. kg) Dimensions portable case: 85 x 6 x 7 mm MultiCon CMC-99: 96 x 96 x 00 mm portable case: 85 x 6 x 7 mm MultiCon CMC-: x x 00 mm SOFTWARE DAQ Manager software is used for service of data loggers MultiCon CMC type. The software allows to visualize recorded data in the form of graphs and tables, group measurement results, create reports and export data into other files. ORDERING P0-CMC-XXX-XX-X-X version: 99A :.5 display, case with a compartment for accessories/sensors, input/output/communication connectors max., mounted on the right side of the case 99B :.5 display, case without a compartment for accessories/sensors, input/output/communication connectors max. : 5.7 display, case without a compartment for accessories/sensors, input/output/communication connectors max. * EXAMPLARY PIN ASSIGNMENT Power supply: 85..60V AC/DC - L - N - n.c. - PE Ethernet number of connectors: Ethernet port: 0 : none : RJ5 power supply: : V AC/DC : 85V - 60V AC/DC... * - full order code for the MultiCon CMC-99/ should also be provided Ordering example: P0-CMC-99A--0- with CMC-99-PS/E/E/E/RT-0B ACCESSORIES IN: Voltage input 0-0V 5 IN: RTD input 5 - V DC* - IN + - IN - - GND. -wires IN: Current input 0-0mA 5 -wires - V DC* - IN + - IN - - GND. -wires. mm MS - USB flash drive An incredibly small, light and stylish flash drive offering or 8 GB data storage (. x. mm / 6 g) has been designed with easy storage and transport in mind. It will easily fit in a P0 case with a closed upper lid. RS-85 5 - DATA+ - DATA - - GND OUT: REL 5 - - - - n.c.. 5

up to input/output/communication connectors P0-SRD-99 LCD.9 monochrome display USB Host port for flash data storage electronic relay outputs optional The portable MultiLog SRD-99 data recorder set in a P0 portable case is designed to record, display current or average values and present data in the form of trend graphs of various technological parameters. The set may be equipped with to 8 measuring inputs: 0/-0 ma or Pt 00/500/000 and, optionally, relay outputs. The primary function of the outputs is signalling alarm states but the configuration menu also allows to use them in a variety of control systems. Each of the outputs can be controlled by a single channel or group of measurement channels with individually adjustable thresholds. The recorder was placed in a high quality PELI transport case. High impact, dustproof and waterproof case housing allows to use the set virtually in any environmental conditions. The main advantages: - USB Host port to retrieve and store the data in flash memory, - waterproof and dustproof case housing, designed to work in conditions of high humidity, high temperature jumps, dust, pressure differences, etc., - MB data memory or 8 MB in the version with USB interface, - free configuration and recording software. ACCESSORIES. mm MS - USB flash drive An incredibly small, light and stylish flash drive offering or 8 GB data storage (. x. mm / 6 g) has been designed with easy storage and transport in mind. It will easily fit in a P0 case with a closed upper lid. 6

SOFTWARE The Loggy Soft enables the visualization, archiving and printing of measurements (e.g. temperature, humidity, pressure) stored in MultiLog device memory. P0-SRD-99 The S-Toolkit enables configuration reading and writing operations, updating the device firmware and obtaining basic information on MultiLog series devices through RS-85 serial interface or flash-disk devices plugged into USB port. TECHNICAL DATA Power supply Measuring inputs Digital input Measuring range Outputs Sensor supply output Communication interface Display Memory capacity SRD-99 in portable case 9V 50V DC; 6V 5V AC or 85 60V AC/DC up to 8 measuring inputs digital input, 0-0V DC 0/-0 ma; 0/-5V, 0/-0V or Pt00 / Pt500 / Pt000 (-wires) electronic relays (ER, ER), VAC (5VDC)/00 ma V DC / max. 00 ma, not separated RS-85, Modbus RTU, 00 500 bit/sec..9 LCD, graphic, 8 x 6 pkt, with backlight MB in version without USB Host port 8 MB in version with USB Host port EXAMPLARY PIN ASSIGNMENT Power supply 85..60V AC/DC IN: Current input 0/-0 ma 5 - n.c. - n.c. - GND - IN+ 5 - V DC - L - N - n.c. - PE Protection class IP 67 Operating temperature Weight Materials 0 C +50 C.5 kg (case. kg) body: Polypropylene latch: ABS lid O-Ring: Polymer pins: Stainless Steel IN: Pt 00/500/000 input 5 OUT- -wires - -wires RS-85 -wires Dimensions portable case: 85 x 6 x 7 mm MultiLog SRD-99: 96 x 96 x 00 mm 5 - n.c. - - n.c.. 5 - DATA+ - DATA - - GND SET CONTENTS - PELI portable case, - MultiLog SRD-99 data logger, - power cable, - connectors (socket-plug) for sensors and communication links in the ordered amount, - compartment for accessories/sensors, - CD-ROM with software and manuals. ORDERING number of connectors:... P0-SRD-99-XX-0-X power supply: : V AC/DC : 85V - 60V AC/DC Optionally: - SRS-/-Z5 (RS-/RS-85 converter) - SRS-U/-Z5 (USB/RS-85 converter) - MS- ( GB) or MS-8 (8 GB) mini pendrive USB. * - full order code for the MultiLog SRD-99 should also be provided Ordering example: P0-SRD-99--0- with SRD-99-8---0B 7

BRRDPEN_v..0