SREDU Double Connection Option Card for Lon Star Coupler RER 111

Similar documents
LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

Synchro-check relay. Application

Residual overvoltage relay

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

RER 123 Bus Connection Module. Technical Description

Earth-fault Relay SPAJ 110 C. Product Guide

Arc protection relay. Features Three-phase overcurrent function. Application

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide

Communication Gateway COM 500. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

High impedance protection relay

Arc protection relay. Features Three-phase overcurrent function. Application

LON bus LonWorks Network in Protection and Control Systems. User s manual and Technical description

Data communication and reporting unit

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

Feeder protection relay

LNT 505 Installation and Commissioning Manual

Feeder protection relay SPAA 341 C. Product Guide

Data communication and reporting unit

Communication Gateway COM 610. Product Guide

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

SmartRouters Optionally with Bus Diagnostics RTRS RTRSD

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

Relay Product Engineering Tools

LONWORKS Power Line Communication Adapter

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

Relay configuration and setting tool package

LONWORKS. TPT Twisted Pair Transceiver Module User s Guide. Revision 3. C o r p o r a t i o n C

INSTALLATION INSTRUCTIONS

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

PXR11 PXR12. System controllers DESIGO PX

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

General characteristics of C-type relay modules

ICF-1150 Series Quick Installation Guide

TF501, TF521 Terminal Bases

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Next Generation Intelligent Lon EIA/ANSI 709 Router Datasheet

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique

CM589 PROFINET Communication Module

CM579-PNIO PROFINET Communication Module

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

Start-up Guide. AF 100 Adapter Kit NAFA-01

TU531, TU532 Terminal Unit

DF PROFI II PC/104-Plus

Relion 611 series. 611 series Type Test Certificate

Ethernet Adapter. Modbus/TCP Brigde. Installation and Commissioning Manual

ABB Drives. User s Manual I/O Module Adapter AIMA-01

ICF-1150 Series Quick Installation Guide

LON Module for Variable Speed Drive

LONMANAGER NSS-10 MODEL

REM 543 Machine Terminal. User s Guide for Modbus Configurations

Remote Bus Extender Slave Module

Pyxos FT Network Chip 11500R

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

CM589 PROFINET Communication Module

Rugged MediaConverter

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

AO523 Analog Input Module

MINER-S Station Controller. Substation Automation

Feeder Protection Relay REF 610. Product Guide

TCP. Control and Protection Terminal Data sheet

CI504 PROFINET Communication Interface Module

NodeBuilder 3.1 Development Tool Model 10020

LX Series Remote Input/Output (I/O) Controller

Power Products. Station Automation COM600 Product Guide

MINER-S Station Controller

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

i.lon SmartServer Models 7210xR-4xx, , 72160, and Description Programmable

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Extension module for graphic Web functions for one automation station

AC Series Fast Ethernet Media Converters AC100SC AC100ST AC100SFP AC100SC.20 AC120SC.20. User Manual

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

TCF-142 Quick Installation Guide

Communicate IT Software module DR-COM. Buyer s Guide

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Power supply module, bus connection module

Motor Protection Relay REM 610. Product Guide

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

CM597 Ethernet Communication Module

Communication with EuroProt-IED Multifunctional intelligent devices

CM592 PROFIBUS Communication Module

Extension module for Web functions generic

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

RT4B-110V/12A RECTIFIER

crio PN Installation Instructions V0.2/ COMSOFT

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

RT12-240V/2.4kW Rectifier Specification

LN Series Remote Input/Output (I/O) Modules

DI572 Digital Input Module

Control Panel CP600 CP651, CP651-WEB

TCF-142-RM Series Hardware Installation Guide

Extension module for BACnet over Ethernet / IP and graphic Web functions

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Binary output and supervision 520CSD01 Data sheet

Transcription:

SREDU Lon Star Coupler RER 111 Technical Reference Manual ABB Automation

1MRS 750108-MUM Issued: 21.11.1996 Version: B2/18.2.2000 Checked: M.K. Approved: T.S. Technical Reference Manual SREDU We reserve the right to change data without prior notice. Contents: 1. Introduction...4 2. Functions...5 3. Mechanical and electrical design...6 3.1. Block diagram...6 3.2. Mechanical structure...6 4. Interfaces...7 5. Installation...8 6. Technical data...9 7. Maintenance and service...10 7.1. Fibre optic receiver LED...10 7.2. Redundant error LED...10 7.3. Service and spare parts...10 8. Ordering information...11 Revision history Date Revision Author Description??.??.???? A T. Peltoniemi Original version 29.12.1999 B1 M. Kiikkala Update version (Q4/99) 21.02.2000 B2 M. Kiikkala References to SMA-transceiver option removed Echelon, LON, LonBuilder, LonManager, LonTalk, Neuron, and 3150 are U.S. registered trademarks of Echelon Corporation. LonLink, LonMark, LonSupport, LonUsers, LonWorks, LonMaker and 3120 are trademarks of Echelon Corporation ABB Automation 3

SREDU 1MRS 750108-MUM 1. Introduction The double connection option card is designed for use within the LON Star Coupler RER 111. This device is not a "stand-alone" device, but part of an integrated communication system. The double connection option card provides the means to connect two RER 111 units together by using double connections. This method enables two fibre optic cables to be used. This double connection allows for the possibility of a fault to occur in one fibre optic connection, still remaining able to receive and transmit data to the device. An example of this type of connection can be seen below in figure 1.-1. MicroSCADA Fibre Optic Connection Double connection option card Fibre Optic Connection to Bay Level Devices Fibre Optic Connection to Bay Level Devices sredu_1 )LJ ([DPSOHRIDGRXEOHILEUHRSWLFV\VWHP The double connection option card is equipped with two fibre optic transceiver pairs. Two types of transceiver pairs are available: - ST-type glass fibre optic transceiver - snap-in-type plastic fibre optic transceiver These transceiver types are not interchangeable, but should be specified in the order. For ordering information see chapter 8. 4 ABB Automation

1MRS 750108-MUM SREDU 2. Functions The double connection option card has two fibre optic transceiver pairs. These are connected to a LON device allowing a double fibre optic connection. LON messages can be received from one receiver or both receivers at the same time. The message received is then passed on to the mother board of the RER 111 unit. Both fibre optic receivers are connected to the open collector bus on the mother board through a receiver selection logic. This allows the message to be transmitted in both fibre optic channels. The receiver selection logic only permits one of the receivers to transmit the duplicated data to the open collector bus, thus avoiding message duplication on the open collector bus. The receiver is selected at random. If a message is to be transmitted from the mother board through the double connection option card, then this message is transmitted via both fibre optic transmitters to the attached device. Both fibre optic receivers have indication LEDs that flash when a message is being received. The double connection option card also supports message collision detection within the RER 111 unit. The double connection option card has a self supervision feature for continuous light reception. If one (or both) fibre optic channel receives continuous light, the reception on the channel in question is cut off. The error is notified to the I/O module of the RER 111 LON Star Coupler via the error line. Error reset is also notified. For information regarding the error line of the RER 111 Star Coupler, refer to the RER 111 manual 1MRS750104-MUM, chapter 4.1. The indication LED of a channel is continuously lit if continuous light is received in the corresponding channel. Then the redundant error LED is continuously lit as well. ABB Automation 5

SREDU 1MRS 750108-MUM 3. Mechanical and electrical design 3.1. Block diagram Redundant fibre optic interface RX LED TX LED RX LED TX Continuous light control Redundant diagnostic Continuous light control Control Logic Redundant control Control Logic )LJ Internal error line Internal open collector bus %ORFNGLDJUDPRIWKHGRXEOHFRQQHFWLRQRSWLRQFDUG sredu_2 3.2. Mechanical structure The double connection option card is built on a printed circuit board (PCB) of size 100 mm x 160 mm. The size of the front plate is 116.4 mm x 19.8 mm. SREDU-C-MM Fibre optic TX Fibre optic RX Fibre-optic LED Redundant Error Redundant error LED Fibre optic TX Fibre optic RX Fibre-optic LED 0282D sredu_3 )LJ 0HFKDQLFDOVWUXFWXUHRIWKHGRXEOHFRQQHFWLRQRSWLRQFDUG 6 ABB Automation

1MRS 750108-MUM SREDU 4. Interfaces The double connection option card has three separate interfaces: - a 64 pin E1 card connector for the connection to the mother board of the RER 111 unit - 2 fibre optic transceiver pairs. The length of the fibre optic cables used in the different channels of the double connection option card may vary, but have to be within the limits specified in the RER 111 manual 1MRS750104-MUM, chapter 6.2 For more information regarding the fibre optic cables and the fibre optic connection of the option cards, refer to the RER 111 manual 1MRS750104-MUM, chapter 6.2 ABB Automation 7

SREDU 1MRS 750108-MUM 5. Installation As the double connection option card is not intended for "stand-alone" use, it has to be installed in the RER 111 unit. It can be placed in any of the 9 slots available. To install the double connection option card in the RER 111 unit: 5HPRYHWKHVWUDLQVFUHZVRQWKHEODQNSODWHRUWKHIURQWSODWHRIWKHRSWLRQ FDUGLQVWDOOHG /LIWRIIWKHEODQNSODWHRUSXOOWKHUHTXLUHGRSWLRQFDUGRXWRIWKHFDVLQJ 5HSODFHWKHROGRSWLRQFDUGZLWKDQHZRQHWKHFRPSRQHQWVLGHIDFLQJ DZD\IURPWKHSRZHUVXSSO\ 3XVKWKHRSWLRQFDUGLQWRWKHXQLWXQWLOWKHIURQWSODWHLVIOXVKZLWKWKH UDFN 7LJKWHQWKHRSWLRQFDUGRUWKHEODQNSODWHWRWKHFDVHZLWKWKHVWUDLQ VFUHZV 1RWLFHDo not touch the fibre optic transceiver. Do not remove dust shields from transceivers not in use. SFIBER-C-BB SROUT-C-BB SLCM-C-BBB SFIBER-C-BB SFIBER-C-BB SSLTA-C-BB SERVICE PIN SREDU-C-BB SERVICE 1 2 3 4 5 6 7 8 9 1 2 TP 1.25M/78k Net A Service Pin Net B TP RS232 Service Led Service PinRedundant RS232 Error Puls e 1 2 1 2 RS232 Service Led Service Pin RS232 U1aux 10 11 12 U2aux 3 3 3 1MRS060023 1MRS060023 sredu_4 )LJ SREDU Option Card Strain screw,qvwdoodwlrqriwkhgrxeohfrqqhfwlrqrswlrqfduglqwkh5(5xqlw 8 ABB Automation

1MRS 750108-MUM SREDU 6. Technical data Interfaces Fibre optic interface Communication speed Connection to the mother board glass fibre with ST-type connectors plastic fibre with snap-in-type connectors 1.25 Mbit/s 64 pin E1 connector Power source Mother board interconnection +8 VDC Power consumption SREDU-C-MM option card SREDU-C-BB option card <1.4 W <1.4 W Size E1 card Front plate 100 mm x 160 mm (E1 card) 116.4 mm x 19.8 mm (front plate) Disturbance tests High frequency interference test according to IEC 60255-22-1 - common mode 2.5 kv, 1 Mhz - differential mode 1.0 kv, 1 Mhz Fast transient test according to IEC 61000-4-4 and IEC 60255-22-4, cl. 4 4 kv Electrostatic discharge test according to IEC 61000-4-2 and IEC 60255-22-2, class III - contact discharge 6 kv - air discharge 8 kv Environmental conditions Specified ambient service temperature range Transport and storage temperature range -10...+55 C -40...+70 C Climatic environmental tests Dry heat test according to IEC 60068-2-2 Dry cold test according to IEC 60068-2-1 Damp heat test according to IEC 60068-2-30 +55 C -10 C RH = 93%, 55 C, 6 cycles ABB Automation 9

SREDU 1MRS 750108-MUM 7. Maintenance and service 7.1. Fibre optic receiver LED The receiver LED flashes when a message is being received from the corresponding fibre optic channel. If the LED is continuously lit, the corresponding channel is heavily loaded or the channel receives continuous light. 7.2. Redundant error LED The redundant error LED indicates errors as follows: 1. If the error LED flashes, then one of the channels is broken. 2. If the error LED is continuously lit, then one of the channels or both channels receive continuous light. 7.3. Service and spare parts If a fault occurs in the double connection option card, the faulty option card should be replaced with a new one. For ordering information, see chapter 8. 10 ABB Automation

1MRS 750108-MUM SREDU 8. Ordering information When ordering please state the following: 1. Quantity 2. Type of fibre optic transceivers. Type designation: Double connection option card Double connection option card with ST-type glass fibre optic transceivers Double connection option card with snap-in-type plastic fibre optic transceivers 7\SH'HVLJQDWLRQ SREDU-C-MM SREDU-C-BB Example: 2 pcs SREDU-C-MM Two double connection option cards with ST-type glass fibre optic transceiver pairs. Card identification Number of cards required ABB Automation 11

ABB Substation Automation Oy P.O. Box 699 FIN-65101 VAASA Finland Tel. +358 10 224 000 Fax. +358 10 224 1094 www.abb.fi 1MRS 750108-MUM EN 05.2000